The instructions to be followed are classifi ed by the following symbols:
This symbol denotes an action
that is PROHIBITED.
To prevent personal injury, injury to others, or property damage, please observe the following.
Incorrect operation due to failure to follow instructions may cause harm or damage, the seriousness of which is classifi ed as below:
Warning
This sign warns of death or serious injury.
These symbols denote actions
that are COMPULSORY.
This sign warns of
Caution
injury or damage
to property.
Remote Control
• Do not use rechargeable
(Ni-Cd) batteries.
• Do not allow infants and
small children to play with
the remote control to prevent
them from accidentally
swallowing the batteries.
• Remove the batteries if the
unit is not going to be used for
a long period of time.
• New batteries of the same
type must be inserted
following the polarity stated
to prevent malfunction of the
remote control.
Indoor Unit
• Do not install, remove and
reinstall the unit by yourself;
improper installation will
cause leakage, electric shock
or fi re. Please consult an
authorized dealer or specialist
for the installation work.
• Do not insert your fi ngers or
other objects into the unit.
• Do not attempt to repair the
unit by yourself.
Air inletAir inlet
Indoor Unit
• Do not install the unit in a potentially
explosive atmosphere.
• Do not wash the unit with water,
benzene, thinner or scouring
powder.
• Do not use for other purposes such
as preservation of food.
• Do not use any combustible
equipment in front of the airfl ow
outlet.
• Do not expose directly to cold air for
a long period.
• Ensure that the drainage pipe is
connected properly. Otherwise,
leakage may occur.
• Aerate the room regularly.
Power Supply
• Do not share the same power outlet with
other equipment.
• Do not modify power cords.
• Do not use extension cords.
• Do not operate with wet hands.
• Do not operate or stop the unit by inserting
or pulling out the power plug.
• Insert the power plug properly.
• Use the specifi ed supply cord.
• If the supply cord is damaged, it must be
replaced by the manufacturer, its service
agent or similarly qualifi ed persons in order
to avoid a hazard.
• Dust on the electric power plug should be
periodically wiped with a dry cloth.
• This equipment must be earthed and
strongly recommended to be installed with
Earth Leakage Circuit Breaker (ELCB) or
Residual Current Device (RCD). Otherwise,
Air Air
outletoutlet
Air inlet
Air inlet
Air outlet
Power Supply
• Do not pull the cord to disconnect the
plug.
• Switch off the power supply and
unplug before cleaning or servicing.
• Turn off the power supply and unplug
if the unit is not used for a long period
of time.
• This air conditioner is equipped with
a built-in surge protective device.
However, in order to further protect
your air conditioner from being
damaged by abnormally strong
lightning activity, you may want to
disconnect it from the power supply.
Do not touch the air conditioner
during lightning, it may cause electric
shock.
it may cause electrical shock or fi re in case
of malfunction.
• In case of emergency or abnormal
conditions (burnt smell, etc), turn off the
power supply and unplug, and consult your
nearest dealer.
Outdoor Unit
• Do not sit, step or place anything on
the unit.
• Do not touch the sharp aluminium
fi n.
• Ensure that the drainage pipe is
Outdoor Unit
• Do not insert your fi ngers or other objects
into the unit.
connected properly. Otherwise,
leakage may occur.
• After long periods of use, make sure
the installation rack is not damaged.
2
REGULATORY INFORMATION REGULATORY INFORMATION
The appliance is not intended for use by young children or the infi rm person without
supervision. Young children should be supervised to ensure that they do not play
with the appliance.
OPERATION CONDITIONOPERATION CONDITION
Use this air conditioner under the following temperature range
Temperature (°C)
COOLING
HEATING
Maximum32234326
Minimum16111611
Maximum30-2418
Minimum16--5-6
* DBT: Dry bulb temperature
* WBT: Wet bulb temperature
IndoorOutdoor
*DBT*WBT*DBT*WBT
Thank you for purchasing
Air Conditioner
TABLE OF CONTENTSTABLE OF CONTENTS
SAFETY PRECAUTIONS
REGULATORY INFORMATION
PRODUCT OVERVIEW &
OPERATIONS
CARE & CLEANING
TROUBLESHOOTING
QUICK GUIDE
BACK COVER
2
ENGLISH
3
4~5
6
7
Replacement or installation of power plugs shall be performed by authorized/
qualifi ed personnel only. The wires in this mains lead are coloured in accordance
with the following code:
wires
colours
Terminals
red
black
green/yellow
live
neutral
earth
(GB Standard)
brown
blue
green-yellow
NOTE :NOTE :
The illustrations in this manual are
for explanation purposes only and
may differ from the actual unit. It is
subjected to change without notice
for future improvement.
Wiring colour may vary depending on a country wiring code’s standard.
ENVIRONMENTAL REQUIREMENTS
Battery Disposal
The batteries must be recycled or disposed of properly.
END-OF-LIFE DISPOSAL
“Instructions for end-user” for air conditioners:
Information on Disposal in other countries outside the European Union
This symbol is only valid in the European Union. If you wish to discard this product, please contact your
installer, dealer or local authority and ask for the correct method of disposal.
• Do not switch ON the unit when waxing the fl oor. After waxing, aerate the room properly before operating the unit.
• Do not install the unit in oily and smoky areas.
• Unit selects the operation mode according to the room
temperature.
• Once auto mode is selected, the unit will operate at the standard
setting temperature.
• To change the standard setting temperature, press
23°C & aboveCool25°C27°C23°C
HEAT mode - To enjoy warm air
• In heat mode, it takes a while for the unit to warm up. The power
indicator blinks during this operation.
COOL mode - To enjoy cool air
DRY mode - To dehumidify the environment
• Unit operates at low fan speed to give a gentle cooling operation.
Auto OFF/ON button
• Used when remote control is misplaced
or malfunction.
ActionMode
Press once.Auto
Press and hold until 1 beep
is heard, then release.
Press the button to turn off.
INDICATOR
(Green) (Orange) (Orange) (Orange) (Blue)
Receiver
TO TURN ON OR OFF THE UNIT
TO SET TEMPERATURE
TO SELECT OPERATION MODE
for “LO”.
Room
temperature
Below 23°CDry22°C24°C20°C
Below 20°CHeat21°C23°C19°C
Operation
mode
Standard setting
temperature
HI
(+2°C)
Cooling
for “HI” or
LO
(-2°C)
TO SELECT FAN SPEED
(3 OPTIONS)
• For AUTO, the indoor fan speed is automatically
adjusted according to the operation mode.
TO SET THE TIMER TO SET THE TIMER
• To turn ON or OFF the unit at a preset time.
ENGLISH
4)-%2
TO ADJUST AIRFLOW
DIRECTION (5 OPTIONS)
• Keeps the room ventilated.
• If AUTO is set, the louvers swing left/right and
up/down automatically.
• In heat mode, the air blows horizontally for a while,
then starts to blow downwards and the airfl ow louver
start to swing left/right after the temperature rises.
TO ENJOY CLEAN &
FRESH AIR
• Generates negative ions to produce fresh air effect
and attract dust which will then be captured at the
positively charged e-ion fi lters.
TO MONITOR AIR
QUALITY
• Patrol sensor detects air quality.
• When air quality is at dirty
level, e-ion operation will start
automatically.
Indicator Air Quality
BlueClean
Orange Moderate
RedDirty
TO ENJOY QUIET
ENVIRONMENT
• This operation reduces airfl ow noise.
TO ACHIEVE TEMPERATURE
QUICKLY
• This operation will stop automatically after 15 minutes.
Select ON or
Set the time.Confi rm.
OFF timer.
• To cancel ON or OFF timer, press
or then
press .
• When ON Timer is set, the unit may start earlier (up
to 30 minutes) before the actual set time in order to
achieve the desired temperature on time.
• Timer operation is based on the clock set in the remote
control and repeats daily once set. For clock setting,
please refer to Remote Control Preparation at back
cover.
• If timer is cancelled manually or due to power failure,
you can restore the previous setting (once power is
resumed) by pressing
.
OPTIONAL SETTINGS OPTIONAL SETTINGS
Patrol starts automatically with the unit
switched on with
Press and hold for 5 seconds, then release
to disable or restore this setting.
Press and hold for 5 seconds to dim or
restore the unit’s indicator brightness.
Press and hold for approximately 10
seconds to show temperature setting in
°C or °F.
Press and hold for approximately 5 seconds
to show 12-hour (am/pm) or 24-hour time
indication.
.
• , , and can be activated
in all modes and can be cancelled by pressing the
respective button again.
and or and can not be
•
selected at the same time.
and can be activated even when the
•
unit is turned off. In this condition, fan speed and air
swing can not be adjusted.
Press to restore the remote control’s default
setting.
Not used in normal operations.
Temperature setting of 1°C higher in cool mode or
2°C lower in heat mode than the desired temperature
performs a 10% power saving.
Use curtains to screen off sunlight and outdoor heat to
reduce power consumption during cool mode.
5
CARE & CLEANING CARE & CLEANING
• Switch off the power supply and unplug before cleaning.
CAUTION
• Do not touch the aluminium fi n, sharp parts may cause injury.
WASHING INSTRUCTIONSWASHING INSTRUCTIONS
• Do not use benzene, thinner or scouring powder.
• Use only soap (
• Do not use water hotter than 40°C.
pH7) or neutral household detergent.
ALUMINIUM FINALUMINIUM FIN
RemoveRemove
e-ion FILTERS e-ion FILTERS
• Clean the fi lters regularly.
• Wash/rinse the fi lters gently with water
to avoid damage to the fi lter surface.
• Dry the fi lters thoroughly under
the shade, away from fi re or direct
sunlight.
• Replace any damage fi lter.
HINTS HINTS
• Clean the fi lter regularly for best performance and to
reduce power consumption.
• Please consult your nearest dealer for seasonal
inspection.
FRONT PANELFRONT PANEL
Raise and pull to remove. Wash
gently and dry.
INDOOR UNITINDOOR UNIT
Wipe the unit gently with a soft,
dry cloth.
ACTIVE e-ion GENERATORACTIVE e-ion GENERATOR
Clean with dry cotton bud.
• Active e-ion generator
cleaning is recommended
every 6 months.
ACTIVE e-ion POWER MODULEACTIVE e-ion POWER MODULE
FOR SEASONAL INSPECTION AFTER EXTENDED FOR SEASONAL INSPECTION AFTER EXTENDED
NON-USENON-USE
• Checking of remote control batteries.
• No obstruction at air inlet and air outlet vents.
• After 15 minutes of operation, it is normal to have the
following temperature difference between air inlet and air
outlet vents:
Cooling: ≥ 8°C Heating: ≥ 14°C
FOR EXTENDED NON-USEFOR EXTENDED NON-USE
• Activate heat mode for 2~3 hours to remove moisture left in
the internal parts thoroughly.
• Turn off the power supply and unplug.
• Remove the remote control batteries.
6
NON SERVICEABLE CRITERIASNON SERVICEABLE CRITERIAS
TURN OFF POWER SUPPLY AND UNPLUG then CALL
Authorized Distributor under the following conditions:
• Abnormal noise during operation.
• Water/foreign particles have entered the remote control.
• Water leaks from Indoor unit.
• Circuit breaker switches off frequently.
• Power cord becomes unnaturally warm.
• Switches or buttons are not functioning properly.
TROUBLESHOOTING TROUBLESHOOTING
The following symptoms do not indicate malfunction. The following symptoms do not indicate malfunction.
SymptomSymptomCauseCause
Mist emerges from indoor unit.• Condensation effect due to cooling process.
Water fl owing sound during operation.• Refrigerant fl ow inside the unit.
The room has a peculiar odour.• This may due to damp smell emitted by the wall, carpet, furniture or
Indoor fan stops occasionally during automatic
fan speed setting.
Operation is delayed a few minutes after
restart.
Outdoor unit emits water/steam.• Condensation or evaporation occurs on pipes.
Timer indicator is always on.• The timer setting repeats daily once set.
Power indicator blinks during operation and
the indoor fan is stopped.
Indoor fan stops occasionally during heating
operation.
Cracking sound during operation. • Changes of temperature cause the expansion/contraction of the unit.
Inconsistent airfl ow during PATROL operation. • Fan speed is adjusted automatically during patrol operation.
Check the following before calling for servicing. Check the following before calling for servicing.
SymptomSymptomCheckCheck
Heating/Cooling operation is not working
effi ciently.
Noisy during operation.• Check if the unit has been installed at an incline.
Remote control does not work.
(Display is dim or transmission signal is weak.)
The unit does not work.• Check if the circuit breaker is tripped.
The unit does not receive the signal from the
remote control.
Patrol sensor or e-ion indicator on the indoor
unit is blinking.
clothing.
• This helps to remove the surrounding odours.
• The delay is a protection to the unit’s compressor.
• The unit is in defrost mode, and the melted frost is drained from the
outdoor unit.
• To avoid unintended cooling effect.
Select QUIET operation to maintain the airfl ow consistency.
• Set the temperature correctly.
• Close all doors and windows.
• Clean or replace the fi lters.
• Clear any obstruction at the air inlet and air outlet vents.
• Close the front panel properly.
• Insert the batteries correctly.
• Replace weak batteries.
• Check if timers have been set.
• Make sure the receiver not obstructed.
• Certain fl uorescent lights may interfere with signal transmitter. Please
consult your nearest dealer.
• Press
blinking, please consult your nearest dealer.
or twice. If the patrol sensor or e-ion indicator still
ENGLISH
7
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.