Before attempting to connect, operate or adjust this product, please read these instructions completely.
Printed in Japan
VQT9921F0502H
3
@
For Your Safety
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
THIS APPARATUS MUST BE GROUNDED
To ensure safe operation the three-pin plug must be
inserted only into a standard three-pin power outlet
which is effectively grounded through normal household wiring.
Extension cords used with the equipment must be
three-core and be correctly wired to provide connection to the ground. Incorrectly wired extension cords
can be extremely hazardous.
The fact that the equipment operates satisfactorily
does not imply that it is grounded, and the installation is not necessarily safe. For your safety, if in any
doubt about the effective grounding of the equipment
or power outlet, please consult a qualified electrician.
DO NOT REMOVE COVER (OR BACK).
NO USER-SERVICEABLE PARTS INSIDE.
within an equilateral triangle, is intended to
alert the user to the presence of uninsulated
dangerous voltage within the products enclosure that may be of sufficient magnitude
to constitute a risk of electric shock to persons.
The exclamation point within an equilateral
triangle is intended to alert the user to the
presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
WARNING:
TO REDUCE THE RISK OF FIRE OR SHOCK HAZARD, DO NOT EXPOSE THIS EQUIPMENT TO
RAIN OR MOISTURE.
CAUTION:
TO REDUCE THE RISK OF FIRE OR SHOCK HAZARD AND ANNOYING INTERFERENCE, USE THE
RECOMMENDED ACCESSORIES ONLY.
CAUTION:
TO REDUCE THE RISK OF FIRE OR SHOCK HAZARD, REFER MOUNTING OF THE OPTIONAL
UNIT TO AUTHORIZED SERVICE PERSONNEL.The lightning flash with arrowhead symbol,
CAUTION:
TO REDUCE THE RISK OF FIRE OR SHOCK HAZARD, REFER CHANGE OF THE SWITCH SETTING
INSIDE THE UNIT TO AUTHORIZED SERVICE
PERSONNEL.
FCC Note:
This device complies with Part 15 of the FCC Rules.
To assure continued compliance follow the attached
installation instructions and do not make any unauthorized modifications.
This equipment has been tested and found to comply
with the limits for a Class A digital device, pursuant to
Part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses,
and can radiate radio frequency energy and, if not installed and used in accordance with the instruction
manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which
case the user will be required to correct the interference at his own expense.
CAUTION:
Do not install or place this unit in a bookcase,
built- in cabinet or in another confined space in
order to keep well ventilation condition. Ensure
that curtains and any other materials do not obstruct the ventilation condition to prevent risk of
electric shock or fire hazard due to overheating.
WARNING:
TO REDUCE THE RISK OF FIRE OR SHOCK
HAZARD, KEEP THIS EQUIPMENT AWAY
FROM ALL LIQUIDS-USE AND STORE ONLY
IN LOCATIONS WHICH ARE NOT EXPOSED
TO THE RISK OF DRIPPING OR SPLASHING
LIQUIDS, AND DO NOT PLACE ANY LIQUID
CONTAINERS ON TOP OF THE EQUIPMENT.
1 is the safety information.
2
CAUTION:
This apparatus can be operated at a voltage in the
range of 100 – 240 V AC.
Voltage other than 120 V is not intended for U.S.A.
and Canada.
CAUTION:
Operation at a voltage other than 120 V AC may require the use of a different AC plug. Please contact
either a local or foreign Panasonic authorized service center for assistance in selecting an alternate
AC plug.
Contents
For Your Safety ........................................... 2
Precautions for Use..................................... 3
This product is specially designed for industrial use. So, it must be operated by a person having
technical knowledge.
•The liquid crystal portion is manufactured with highly precise technology. It includes over 99.99% of effective pixels,
but 0.01% or less of pixel missing or fixed lighting (red, blue, green) as well. This is not a sign of malfunction.
• If a still image is displayed for a long time, it may cause temporary generation of afterimage (phosphor burn-in).
(Such afterimage will disappear when an ordinary mobile image is displayed for a while.)
• The response speed and brightness of liquid crystal vary with the ambient temperatures.
• Consult with the authorized service person for the installation.
Be sure to consult with the service person about the installation. Make sure that the wall or ceiling is strong enough to endure the
weight of this unit including the mount fittings. If not strong enough, it may cause accidents such as falling off of the unit and
injuries.
• Do not install the unit in a place exposed to the direct sunlight. It may otherwise deteriorate the cabinet or damage the liquid
crystal acreen.
3
4
Front View
M
POWER
!
BLUE
A B
INPUT SELECT
S OPTION
MENU/
EXIT
MENU
ENTER
ONLY
HV
DELAY
PHASE CHROMA BRIGHT
@#$ %
CONTRAST
1
2
3
qS
4
5
6
5
B
How To Use On Screen Menu
How To Get On Screen Menu
BLUE
AB
INPUT SELECT
SOPTION
MENU/
EXIT
ENTER
MENU
ONLY
HV
DELAY
PHASE CHROMA
When MENU/EXIT button is pushed, the main menu appears
on the screen.
MAIN menu
[MAIN]
>MARKER 4
VIDEO CONFIG 4
SYSTEM CONFIG 4
REMOTE CONFIG 4
INPUT SELECT 4
MAINTENANCE 4
[INPUT SIGNAL]
1080/60I
MAIN menu
Main menu includes the following items.
MARKER
Used to make setting for MARKER.
VIDEO CONFIG
Used to set the color temperature, aspect, and monochrome.
SYSTEM CONFIG
Used to set backlight brightness and various status display
and to save/load the set-values.
REMOTE CONFIG
Used to set the pin assignment of REMOTE input terminal.
INPUT SELECT
Used to set the format for each input connector.
MARKER
[MARKER]
>MARKER 16:9 OFF
MARKER 4:3 OFF
MARKER BACK NORMAL
[GPI]
PRESET1 80%
PRESET2 80%
MARKER menu
With MARKER selected, the following menu will appear.
MARKER 16:9
Used to set Marker used when 16:9 signal is displayed.
Set-value (underlined is default value)
4:313:914:9
95%93%88%80%
OFF
MARKER 4:3
Used to set Marker used when 4:3 signal is displayed.
Set-value (underlined is default value)
95%93%88%80%
OFF
MARKER BACK*
Used to make setting for printing out by half tone or black with
respect to external area of 4:3/13:9/14:9 Marker display unit.
Set-value (underlined is default value)
NORMAL HALFBLACK
[GP1]
• PRESET 1
Used to set Marker displayed by MARKER 1 of GPI (remote
control).
Set-value (underlined is default value)
4:313:914:9
95%93%88%
• PRESET 2
Used to set Marker displayed by MARKER 2 of GPI (remote
control).
Set-value (underlined is default value)
4:313:914:9
95%93%88%
1)
80%
80%
MAINTENANCE
Operation time of LCD and backlight is displayed.
[INPUT SIGNAL]
When the format of signal being input is coincidental with the
setting, the type of the signal is displayed. In case the signal
format does not match the setting or the input signal is other
than support, the message will be displayed.
6
*1)MARKER BACK operates only when 4:3/13:9/14:9 MARKER is
displayed by MARKER 16:9. This is not interlocked with MARKER
(MARKER 1 and MARKER 2) control by GPI.
VIDEO CONFIGSYSTEM CONFIG
[VIDEO CONFIG]
>COLOR TEMP D65
SHARPNESS H 3
SHARPNESS V 3
I-P MODE MODE2
MONO OFF
SD ASPECT 4:3
HD ZOOM NORMAL
VIDEO CONFIG menu
With SYSTEM CONFIG selected, the following menu will
appear.
BACKLIGHT
Used to adjust the brightness of backlight.
Set-value (underlined is default value)
With REMOTE CONFIG selected, the following menu will
appear.
GPI1–GPI8
Used to set the pin assignment of REMOTE control terminal.
The settable items are same for each terminal.
For each function of set-value, refer to the “REMOTE specifications.”
Set-value (underlined is default value)
UNDEF
MARKER1 ON/OFF
MARKER2 ON/OFF
MARKER HALF*
MARKER BLACK*
INPUT SEL A
INPUT SEL B
INPUT SEL S
INPUT SEL OP
SD ASPECT*
HD ZOOM*
BACKLIGHT OFF
*1)MARKER HALF and MARKER BLACK are effective only when
MARKER1 and MARKER2 are used with 4:3/13:9/14:9 displayed.
*2)When using SD ASPECT, set SD ASPECT to REMOTE by VIDEO
CONFIG menu.
*3)When using HD ZOOM, set HD ZOOM to REMOTE by VIDEO
CONFIG menu. HD ZOOM is effective only in case of 1080I, 1035I,
720P signal input.
1)
1)
2)
3)
INPUT SELECT
[INPUT SELECT]
>[LINE A,B/S-VIDEO] AUTO
NON-STANDARD OFF
INPUT SELECT menu
With INPUT SELECT selected, the following menu will appear.
LINE A, B/S-VIDEO
Used to set the input format of LINE A, B/S-VIDEO.
Set-value (underlined is default value)
AUTO NTSCPAL
NON-STANDARD
Used to display a signal not in conformity with the broadcasting standard in selection of LINE A, LINE B, S-VIDEO.
Set-value (underlined is default value)
OFF ON
Menu for option unit is further added for each
type of option unit fitted on the rear panel.
_ HD SDI input unit installed [BT-YA300P]
[INPUT SELECT]
>[LINE A,B/S-VIDEO] AUTO
NON-STANDARD OFF
[HD-SDI] AUTO
INPUT SELECT HD-SDI menu
HD-SDI
Used to set the input format of HD-SDI.
Set-value (underlined is default value)
AUTO1080/60I*1)1080/50I
1080/24psF*
720/60P*
*1)1080/60I and 1035/60I are different with respect to the display
size and the matrix used.
Select 1080/60I and 1035/60I even in case of 1080/59.94I and
1035/59.94I signal input.
The status will be correctly displayed on the screen.
*2)Select 1080/24psF even in case of 1080/23.98psF signal input.
The status will be correctly displayed on the screen.
*3)Select 720/60P even in case of 720/59.94P signal input.
The status will be correctly displayed on the screen.
2)
3)
1035/60I*
1)
8
[MAINTENANCE]
RUNNING TIME
OPERATION 0H
LCD 0H
BACKLIGHT 0H
FAN 0H
How To Use On Screen Menu
INPUT SELECT (continued)
_ SDI input unit mounted [BT-Y200P]
[INPUT SELECT]
>[LINE A,B/S-VIDEO] AUTO
NON-STANDARD OFF
[SDI] AUTO
INPUT SELECT SDI menu
SDI
Used to set the input format of SDI.
Set-value (underlined is default value)
AUTO480/60I*
*1) 480/59.94I signal is displayed as 480/60I.
1)
576/50I
_ Component/RGB input unit mounted [BT-YA100P]
[INPUT SELECT]
INPUT SELECT (continued)
RGB
Used to select the format in case of RGB input.
Set-value (underlined is default value)
1)
AUTO*
1035/60I*
480/60P*
2)
4)
1080/60I*2)1080/50I
720/60P*3)576/50I
480/60I*
4)
RGB-SYNC (When RGB is input.)
Used to select Ext. Sync/GREEN-On-SYNC.
Set-value (underlined is default value)
EXTG-ON
*1)In AUTO setting, the settings of display size, status display, and
matrix are same as for 1080I even in case of 1035I input. When
desired to use 1035I setting, set it to 1035/60I.
*2)1080/60I and 1035/60I are different with respect to the display
size and the matrix used. Select 1080/60I and 1035/60I even in
case of 1080/59.94I and 1035/59.94I signal input. The status will
be correctly displayed on the screen.
*3)Select 720/60P even in case of 720/59.94P signal input. The sta-
tus will be correctly displayed on the screen.
*4)480/59.94I and 480/59.94P signals are displayed as 480/60I and
480/60P.
MAINTENANCE
>[LINE A,B/S-VIDEO] AUTO
NON-STANDARD OFF
[YPbPr/RGB] YPbPr
YPbPr AUTO
COMPONENT LEVEL SMPTE
[RGB] AUTO
RGB-SYNC EXT
INPUT SELECT YPbPr/RGB menu
YPbPr/RGB
Used to select the input of YPbPr/RGB.
Set-value (underlined is default value)
YPbPrRGB
YPbPr
Used to select the format in case of YPbPr input.
Set-value (underlined is default value)
1)
AUTO*
1080/60I*
1080/24psF1035/60I*
576/50I480/60P*
COMPONENT LEVEL (480/60I only)
Used to select the input level of component. Select SMPTE
for the signal from MII VTR, and B75 for the signal of 7.5%
setup of Betacam VTR.
Set-value (underlined is default value)
SMPTEB75
2)
2)
4)
1080/50I
720/60P*
480/60I*
MAINTENANCE menu
With MAINTENANCE selected, the following menu will appear.
OPERATION
The total operation time of the whole LCD monitor is displayed.
3)
4)
LCD
The operation time of the LCD panel is displayed.
BACKLIGHT
The operation time of the backlight is displayed.
FAN
The operation time of the exhaust fan is displayed.