Operation and Maintenance Manual for the
SX-90 & SX-80 Sodr-X-Tractor Handpieces
5050-0492 Rev F
Part Number Model Features
6010-0106-P1 SX-80/90 (Black connector) Handpiece Only
6010-0149-P1 SX-90 (Blue Connector) Handpiece Only
6993-0213-P1 SX-80/90 (Black connector) Handpiece & Cubby
6993-0266-P1 SX-90 (Blue Connector) Handpiece & Cubby
PACE SX-90
(Shown)

PACE Sodr-X-Tractor Handpiece
TITLE PAGE
Introduction ....................................................................................................................3
Tip & Tool Stand Setup..................................................................................................4
Handpiece Setup............................................................................................................4
Vacuum Hose Connection .............................................................................................4
Tip Selection ..................................................................................................................5
Tip Installation................................................................................................................5
Temperature Setting ......................................................................................................6
Burn In Procedure..........................................................................................................6
Tip Preparation...............................................................................................................6
Through Hole Solder Extraction.....................................................................................7
Tip Cleaning...................................................................................................................7
Special Applications.......................................................................................................8
Replacing the Disposable Solder Collection Trap .........................................................8
Heater Replacement......................................................................................................9
Corrective Maintenance.................................................................................................9
Handpiece Replacement Parts .....................................................................................10
Service ..........................................................................................................................10
Contact Information ......................................................................................................11
©2008 PACE Inc., Southern Pines, NC. All Rights Reserved Page 2 of 11
www.paceworldwide.com

PACE Sodr-X-Tractor Handpiece
These instructions detail the basic operational guidelines for using the SX-80 & SX-90 Sodr-X-Tractor handpieces.
The SX-80 has yellow coloration on it and the SX-90 has blue coloration on it. The SX-80 is only available in
SensaTemp technology while the SX-90 is available in SensaTemp and Intelliheat technologies.
Introduction
The Sodr-X-Tractor handpiece provides ther mally enhanced through-hole desolderi ng on extra heavy multilayer
assemblies, at safer, lower temperatures, even during continuous use. This Sodr-X-Tractor handpiece features a lar ge
easy to replace solder trap, slim-line, pencil grip design and finger actuated vacuum switch facilitates ease of use and
manipulation in tight places. The Sod r-X-Tractor is a member of the PACE SensaTemp family of advanced handpieces.
CAUTION
Always return heated handpieces to the appropriate Tip & Tool Stand when not
in use. Failure to do so may cause burns to the operator, equipment or work
surfaces and may be a potential ignition source if combustible materials are
nearby. Always use this handpiece in a well-ventilated area to avoid inhalation
of fumes created by solder flux.
NOTE
Always use your Sodr-X-Tractor with a clean VisiFilter element. Otherwise
deterioration in performance or damage to the unit may occur.
Select and enter your desired true operating temperature on your PACE power
source. To save tip life and reduce the possibility of damage, PACE
recommends using the lowest possible tip temperature that will provide rapid yet
controllable melt of the entire solder joint to be extracted. Begin with an
operating temperature in the range of 316°C (600°F) and adjust as necessary.
©2008 PACE Inc., Southern Pines, NC. All Rights Reserved Page 3 of 11
www.paceworldwide.com

PACE Sodr-X-Tractor Handpiece
Handpiece Setup
Connect the handpiece connector plug into one of the Power Receptacles on
your PACE power source in the following manner.
1. Align guide on connector with slot on power receptacle.
2. Insert connector into power receptacle.
3. Turn the connector housing clockwise to lock in p lace.
Vacuum Hose Connection
To set up your Sodr-X-Tractor vacuum hose connection, perform the following steps:
1. Vacuum Hose To Handpiece Connection
a) Attach one end of a 137cm (54 inch) length of air hose to the metal tube in the back of the handpiece.
b) If you have a PACE system incorporating only one handpiece, attach the air hose to the SX-handpie ce
power cable using the supplied Hose Clamps. Space them evenly alon g the length of the power cable
starting at a point 6 inches from the ends of the handpiece.
c) If you have a PACE system incorporating 2 or more air handpieces (e.g. , SX-90/ 80,TP-10 0, TJ-70, TP-65),
you may wish to leave the air hose assembly unattached to allow a quick change to any air handpiece being
used.
Insure that only one air handpiece is connected to either the Vacuum Port or
Controllable PRESSURE Port at one time. Attachment to both ports
2. Prepare a VisiFilter in the following manner:
a) Connect a 1-inch (2.5cm) length of clear P VC a ir ho se t o t he
FLOW OUT side of the VisiFilter; push and turn the hose onto
the VisiFilter nipple to seat.
b) Insert the ribbed end of a male quick connect hose mount
fitting (P/N 1259-0087) into the free end of the 1 inch (2.5cm)
length of air hose connected to the FLOW OUT side of the
VisiFilter.
c) Connect the free end of the 137cm (54 inch) len gth of ai r
hose to the FLOW IN side of the VisiFilter.
d) Insert the end of the quick connect hose mou nt fit ti ng ( on
VisiFilter FLOW OUT side) into the power source Vacuum
Port.
simultaneousl
NOTE
will cause a deterioration of performance.
3. When using air pressure, and/or utilizing multiple air handpieces,
PACE recommends the use of the following set up procedure which utilizes additional quick connect hose
mount fittings. An assortment of quick connect air fittings are supplied with each additional air handpiece.
©2008 PACE Inc., Southern Pines, NC. All Rights Reserved Page 4 of 11
www.paceworldwide.com