• Only use the air purier as described in this manual.
Failure to do so may result in serious injury or death.
• Do not use the air purier with a damaged cord or plug.
Doing so may result in electric shock, serious injury or
death. Have a qualied service technician replace any
damaged cords or plugs.
• Do not handle the unit with wet hands. Doing so may result
in electrical shock, serious injury or death. Thoroughly dry
your hands before handling any part of the air purier.
CAUTION!
• Hair, loose clothing and body parts may get caught in the
machine resulting in injury. Keep hair, loose clothing and
body parts away from openings and moving parts.
• Do not unplug by pulling on the cord. Doing so may result
in electrical sparks and re. Unplug the unit by grasping,
and pulling the plug.
• The Oreck ProShield Series is equipped with an ALCI
(Appliance Leakage Current Interrupter). The ALCI shuts
off the unit in potentially hazardous situations.
Note: A polarized plug has one
rounded prong and one straight prong.
The rounded end goes into the
longest socket slot.
RESET
(Red)
TEST
(Gray)
Note: The ALCI has a Test and Reset button which should
be tested each time the unit is plugged in.
Do not remove the tag which provides test instructions from
around the cord at the ALCI.
1
!
DANGER: Improper installation of ALCI can result in
electric shock.
Do not modify or bypass the ALCI. Do not replace any
electrical component in this product with anything other than
an authorized ORECK replacement part. The risk of electric
shock can result if used in the vicinity of improperly grounded
stationary appliances (stove, refrigerator, washer, etc.).
• Do not use an extension cord.
• Do not place the air purier near sources of heat, such as
stove tops, ovens, radiators or computers.
Placement Warnings
WARNING!
• Do not use the air purier outdoors or on wet surfaces.
Doing so may result in electric shock, serious injury or
death. Use only indoors and under dry conditions.
• Do not use the air purier in an enclosed space where
ammable, combustible or explosive gases are present.
• Do not use in an area where toxic vapors, ammable dust
or oxygen tanks are present. Doing so may result in serious
injury or death. Check the location and make sure these
elements are not present.
CAUTION!
• Do not place open ames, including candles, directly in
front of the air purier.
• Keep objects away from the air intake grille.
It is important to consider the following when deciding on
where to locate the air purier:
• Position the air purier on a at, solid, stable surface. Never
place the unit on soft surfaces such as a bed
or sofa.
• Position the air purier where the dirty air is not drawn
across your head or body while sitting or sleeping.
• Position the air purier so the plug on the power cord easily
reaches a standard electrical outlet for a polarized plug.
SAVE THESE
INSTRUCTIONS
2
Features
1. Pre-Filter: Filters large particles such as dust, hair and lint.
2. Cleaning brush: Use to clean the front and back grilles. Stores snuggly in the compartment under the cover.
3. Odor Absorber: Reduces odors and chemical fumes from
glue, solvents and synthetic materials from the air that
passes through the lter. The air purier continues to lter
particles from the air passing through it with or without the
odor absorber.
4. Truman Cell: Captures small particles such as dust, smoke,
pollen and pet dander from the air that passes through the lter.
5. Catalytic Oxygenator: This model contains a Catalytic
Oxygenator which cannot be removed.
6. Exhaust Grille: Directs the ow of air as it exits the unit.
7. Power Cord: Plug into the outlet to begin use.
8. Removable Base: Allows the air purier to stand vertically.
Simply stand the unit on its base with the Oreck logo facing
front and the control panel buttons at the top.
9. Night Light: The right end will softly glow when the night
light is activated.
10.Cover Release Button: Press in to release the cover for
maintenance access.
11. Truman Collector Cell Light: A solid red light is included
as a handy reminder to clean the Truman Cell. A blinking
light indicates a malfunction that has caused the Truman
cell to shut down and requires attention.
12. Speed Indicator Light: Lighting starts from the center for
the lowest motor speed to all ve lights for full motor speed.
13. Odor Absorber Light: The light indicates that it is time to
replace the odor absorber.
14. Air Revitalizer: This button activates the Air Revitalizer
feature which is designed to run continuously, but may be
turned OFF if desired. Provides additional air freshness
via the release of negative ions, which can also cause dust
particles to clump together and fall out of the air passing
through the air purier. You may notice faster dust buildup
on the unit and surrounding objects with the Air Revitalizer
turned ON.
15. Motor Speed/Power Button: Press the power buttons
repeatedly for the desired speed.
• Low for Silence Technology®. It’s the quietest
operation, cleaning the air as effectively but more
slowly than the high setting.
• Medium for normal use
• High for maximum cleaning
3
2
3
1
13
1415
17
16
12
4
5
6
10
9
11
16. Night Light Button: Repeatedly press this button to change
the lighting scheme to best suit your preference.
17. Front Grille: Air enters here for the rst stage of cleaning.
7
8
4
Operation
3
1. Place. Locate the air purier on a hard surface such as
a table or desk. The unit can be placed horizontally or
vertically depending on your space. Be sure the grille is not
blocked by other objects and there are no candles or ames
near the unit.
2. Plug In. Plug into nearest standard electrical outlet that
accepts a polarized plug.
3. Select the air cleaning speed. Press the motor speed/power
button until you reach the desired speed.
c
l
e
r
a
o
f
S
P
I
Position
T
so that the air is not
drawn across the
head or body.
n
e
r
a
i
r
2
1
5
!
Cleaning
Cleaning Intervals
Proper care and cleaning of the air purier is critical to
performance. The following chart shows the cleaning intervals
and method.
PartCleaning
Time
CabinetAs neededWipe with damp cloth rst.
If required, follow with mild,
non-abrasive cleaner.
Method
Truman Cell2 to 4
weeks
Pre-Filter2 to 4
weeks
Odor
Absorber
Air Direction
Grille
Catalytic
Ozone
Converter
12 months,
or as
needed
As neededUse the brush provided with the
As neededVacuum the front surface gently
WARNING!
Spray Oreck Assail-a-Cell®
cleaner or soak in warm water
or warm water with mild
liquid detergent. Rinse and dry
thoroughly.
Rinse thoroughly in warm
water or as needed.
Replace (optional for odor
removal). Do not wash.
Vacuum gently with a soft
brush attachment to clean if
necessary.
air purier to brush away debris
in between the slots.
with a soft brush attachment.
Do not use any liquids for
cleaning.
Cleaning the unit while it is plugged in may result
in electric shock, electric spark and serious injury.
Unplug the unit before cleaning or maintenance.
6
c
l
e
r
a
o
n
f
S
P
I
T
air purier
will not run if the
Top Cover is not
closed securely.
The
e
r
Cleaning the Pre-Filter
a
i
r
5
2
1. Unplug the air purier and lay it on its side with the hinged
cover on top.
2. Open the Top Cover by pressing the Cover Release button.
3. Pull the Pre-Filter straight up and out of the Cabinet.
4. Thoroughly rinse the Pre-Filter and let it air dry before
placing it back in the Cabinet. Do not use heated or compressed air as part of the drying process.
3
1
5. Slide the Pre-Filter back into the unit.
6. Close the Top Cover securely.
Cleaning the Truman Collector Cell
Note: The Truman Cell may require more frequent cleaning
if “arcing” occurs. Arcing is a sharp snapping sound that occurs when large particles are collected in the Truman Cell. If
prolonged or continuous arcing occurs the Truman Cell should
be cleaned.
1.Unplug the air purier and lay it on its side with the hinged
cover on top.
2.Open the Top Cover by pressing the Cover Release button.
3. Remove the collector cell by pulling up on the handle
(located across the top of the Truman Cell). Lift the
collector cell straight up and out.
4.Place in sink, bathtub or other location where cleaner can
cover every surface.
7
5
c
l
e
r
a
o
n
f
S
P
Oreck’s
I
T
Assail-a-Cell
cleaner is an
excellent way to
clean the
collector cell.
3
1
e
r
a
i
r
7
2
5. Spray Oreck Assail-A-Cell® cleaner between each Cell Plate
and cover each surface. Allow the cleaner to soak for a few
minutes but do not let it dry. Thoroughly rinse the Truman
Cell with clean water.
An alternative method to clean the Truman Cell is to rinse or
soak it in warm water for loose debris. Mild liquid dish
detergent in water may also be used to help break down
tough dirt and residue. Thoroughly rinse the Truman Cell
with clean water.
Note: To prevent damage to the components of the Truman
Cell, do not put in dishwasher or use a cotton swab.
Tough residue such as tar from tobacco smoke may need
additional cleaning or longer soaking.
6. Shake excess water from the Truman cell to speed up drying
time. Do not use heated or compressed air to dry.
7. Place the Truman Cell back into the unit by sliding it straight
down into the slots. The Truman Cell is specially designed
so that it can only be inserted in one direction.
8. Close the Top Cover securely.
Drying the Truman Cell
Note: The Truman Cell must be completely dry after cleaning
in order to operate properly. A drying mode is available to help
remove any residual moisture. While in this mode, the fan will
be running on Medium speed, and no power will be supplied to
the Truman Cell. Once the unit detects that the Truman Cell
8
is completely dry, it will return to its original operating settings
and function as normal.
“Dry Mode” Operation
If the power supply detects that the Truman Cell is wet, it shuts
down power to the cell and causes the Collector Cell light to
blink rapidly.
1. While the collector cell light is blinking, press and hold the
power button to initiate “Dry Mode”
2. Next, the following will all happen simultaneously:
1. Unplug the air purier and lay it on its side with the hinged
cover on top.
2. Open the Top Cover by pressing the Cover Release button.
3. Remove the Odor Absorber, Pre-Filter, and Collector Cell.
4. Vacuum the front face of the lter with a soft-brush
attachment only. Do not use liquids to clean.
5. Replace the Odor Absorber, Collector Cell and Pre-Filter.
Cleaning the Exhaust Grille
2
1
1. Remove the Cleaning Brush from the storage slot located
under the Top Cover.
2. Brush away debris that has collected between the Grille Slots.
3. Return the Cleaning Brush to the storage slot.
10
Maintenance
3
Replacing the Optional Odor Absorber
4
1
2
1. Unplug the air purier and lay it on its side with the hinged
cover on top.
2. Open the Top Cover by pressing the Cover Release button.
3. Flip up the two tabs located on top of the Odor Absorber.
4. Use the tabs to gently lift the odor absorber from the cabinet.
5. Replace with a new Odor Absorber. Fold the tabs down. Do
not force the Odor Absorber into the slot.
6. Close the Top Cover securely.
11
Trouble-
Service problems that appear to be major can often be solved
easily. You can be your own troubleshooter by reviewing this guide.
shooting
All other servicing should be done by an Oreck authorized
service center.
ProblemCheckSolution
Unit does not
turn ON
Truman Cell
light has turned
solid red.
Truman Cell
light is
blinking red
Unit does
not remove
pollutants.
Unit sparks,
crackles and
pops.
• Power Cord
• Selector Switch
• Top Cover
• ALCI Plug
Truman Cell• A solid red light is a 30 day cleaning
Truman Cell• A fast blinking light indicates the power
Truman Cell• Clean the Truman Cell and make sure it is
Truman Cell• Sparking or popping noise (arcing) can
• Plug in Power Cord
• Set Selector Switch for desired blower
speed.
• Make sure the top cover is securely closed
• Press the red reset button each time you
plug in the ALCI safety device.
reminder. Wash Collector Cell. Make sure
it is thoroughly clean and dry before
reinstalling.
supply has shut down due to arcing or
short circuit. The cell should be inspected
and cleaned, repaired, or replaced.
• A slow blinking light indicates the unit is
in Dry Mode.
completely dry before reinstalling.
• Truman cell may be damaged. Contact
Oreck for service.
occur when a large particle is captured
in the Truman Cell. If the unit is arcing
excessively, the cell may be dirty. Try
cleaning the Truman Cell.
• If excessive arcing continues after proper
cleaning, the Truman Cell may be damaged
or wet. If damaged, contact Oreck for
service.
12
ProblemCheckSolution
Odor Absorber
light on unit has
turned red.
Odor Absorber• Replace odor absorber if desired.
• If odor absorber is not replaced, remove
old odor absorber to turn off Check Odor
Absorber light.
Does not
remove odor.
Unit still does
not operate
properly.
Odor Absorber• Vacuum odor absorber with a soft brush
attachment if dirty. Do not use any liquids
to clean the Odor Absorber.
• Replace odor absorber if desired.
Check all the
Contact Oreck for service.
above points.
13
Warranty
ORECK MANUFACTURING COMPANY: (Oreck Manufacturing Company gives you the following limited warranty for this
product only if it was originally purchased for residential use, not
for resale, from Oreck or an Oreck Authorized Retail Dealer.)
Oreck will repair or replace, free of charge, to the original purchaser, any part that is found to be defective in material or workmanship within three (3) years following the date of purchase for
all residential models. NOTE: If the unit is used commercially, a
one (1) year overall warranty applies.
This limited warranty does not cover the replacement of expendable or consumable parts such as lters, cartridges, and other parts
subject to normal wear unless they are defective in material or
workmanship.
This limited warranty does not apply to any part subjected to accident, abuse, commercial use, alteration, misuse, damage caused
by an act of God, the use of voltages other than on the data plate
of this product or service of this product by other than Oreck or a
participating Factory Authorized Service Center.
Oreck does not authorize any person or representative to assume or grant any other warranty obligation with the sale of this
product.
Oreck’s limited warranty is valid only if you retain proof of purchase from Oreck or an Oreck Authorized Retail Dealer for this
product. If you purchase this product from any other source, your
purchase is “AS IS,” which means Oreck grants you no warranty,
and that you, not Oreck, assume the entire risk of the quality
and performance of this product, including the entire cost of any
necessary servicing or repairs of any defects.
Oreck’s liability for damages to you for any costs whatsoever arising out of this statement of limited warranty shall be limited to
the amount paid for this product at the time of original purchase,
and Oreck shall not be liable for any direct, indirect, consequential or incidental damages arising out of the use or inability to use
this product. Some states do not allow the exclusion or limitation
of incidental or consequential damages, so the above limitation or
exclusion may not apply to you.
ALL EXPRESS AND IMPLIED WARRANTIES OTHER
THAN THE LIMITED WARRANTY SET FORTH ABOVE,
FOR THIS PRODUCT, INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE ARE EXPRESSLY DENIED.
This warranty gives you specic legal rights, and you may also
have other rights which vary from state to state.
14
Loading...
+ 39 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.