Omron V1000 DATASHEET

VZ
V1000
More performance & Quality in less space
• Current vector control
• High starting torque (200% / 0.5 Hz)
• 1:100 speed control range
• Double rating ND 120%/1min and HD 150%/1 min
• Online Tuning
• Low-noise Low carrier technology
• 10 years lifetime design
• Built-in filter
• Screw-less terminals
• Control Terminals with memory backup
• 24 VDC control board power supply option
• Fieldbus communications: Modbus, Profibus, CanOpen, DeviceNet, Lonworks, CompoNet, Ethernet, ML-II
• Safety embedded: EN954-1 safety cat. 3, EN6158 SIL II and EN60204-1 Stop category 0
• CE, UL, cUL and TUV
Ratings
• 200 V Class single-phase 0.1 to 4 kW
• 200 V Class three-phase 0.1 to 15 kW
• 400 V Class three-phase 0.2 to 15 kW
System configuration
Power Supply
MCCB
AC Reactor
Filter
V1000
RS232 Communications cable with PC
it n U
y
p o C
B
R
S
R
U
E M
O
C
y p o C
RJ-45 / USB
y
f i r e V
Adapter
d a e R
K
C O L
A W A K
S A Y
1 8 1
-
P O V J
Remote Operator Extansion Cable
24Vdc Control Board Power Supply
Communication Option Board
USB Cable
LCD Remote Operator
CX-Drive CX-One
Choke
Motor
Ground
Mounting Accesories
Braking Resistor
DC Reactor
1V1000
Specifications
Type designation
V1000 series
Z: European standard
A: Standard specs
specifications
VZAB0P1BAA
Ver sion
Coating specs: A: Standard
Enclosure, Fin, Filter: B: IP20 without top cover F: Nema 1 E: IP20 without top cover and C3 filter
Vol tage: B: Single-phase 200 VAC 2: Three-phase 200 VAC 4: Three-phase 400 VAC
200 V class
Single-phase: VZA@ B0P1 B0P2 B0P4 B0P7 B1P5 B2P2 B4P0
Three-phase: VZA@ 20P1 20P2 20P4 20P7 21P5 22P2 24P0 25P5 27P5 2011 2015
Motor
2
kW
Output
characteristics
Power
supply
1. Only HD settings is available for this model
2. Based on a standard 4-pole motor for maximum applicable motor output:
For HD setting 0.12 0.25 0.4 1.1 1.5 2.2 4.0 5.5 7.5 11 15 For ND setting 0.18 0.37 0.55 1.1 2.2 3.0 5.5
Inverter capacity kVA
Rated output current (A) at HD
Rated output current (A) at ND
Max. output voltage
Max. output frequency
Rated input voltage
and frequency
Allowable voltage
fluctuation
Allowable frequency
fluctuation
Heavy Duty (HD) mode with a 150% overload capacity Normal Duty (ND) mode with a 120% overlaod capacity
0.3 0.6 1.1 1.9 3.0 4.2 6.7 9.5 13 18 23
0.8 1.6 3.0 5.0 8.0 11.0 17.5 25.0 33.0 47.0 60.0
1.2 1.9 3.5 6.0 9.6 12.0 19.6 30.0 40.0 56.0 69.0
400 V class
Three-phase: VZA@
Motor
1
kW
Output
characteristics
Power
supply
1. Based on a standard 4-pole motor for maximum applicable motor output:
For HD setting 0.37 0.55 1.10 1.5 2.2 3.0 4.0 5.5 7.5 11 15 For ND setting 0.37 0.75 1.5 2.2 3.0 4.0 5.5 7.5 11 15 18.5
Inverter capacity kVA
Rated output current (A) at HD
Rated output current (A) at ND
Max. output voltage
Max. output frequency
Rated input voltage
and frequency
Allowable voltage
fluctuation
Allowable frequency
fluctuation
Heavy Duty (HD) mode with a 150% overload capacity Normal Duty (ND) mode with a 120% overlaod capacity
40P2 40P4 40P7 41P5 42P2 43P0 44P0 45P5 47P5 4011 4015
0.9 1.4 2.6 3.7 4.2 5.5 7.2 9.2 14.8 18 24
1.2 1.8 3.4 4.8 5.5 7.2 9.2 14.8 18.0 24 31
1.2 2.1 4.1 5.4 6.9 8.8 11.1 17.5 23 31 38
[”P” indicates a decimal point] Max. applicable motor output 0P1: 0.1 kW
~
015: 15 kW
1
1
Proportional to input voltage: 0..240 V
400 Hz
Single-phase 200..240 V 50/60 Hz
3-phase 200..240 V 50/60 Hz
-15%..+10%
+5%
0..480V (proportional to input voltage)
400 Hz
3-phase 380..480 VAC, 50/60 Hz
-15%..+10%
+5%
- - - -
7.5 11 15 18.5
2 Frequency inverters
Specifications
Commom specifications
Model number
VZA@
Control methods
Output frequency range
Frequency tolerance
Resolution of frequency set value
Resolution of output frequency
Overload capability
Control functions
Frequency set value
Braking torque (short term peak torque)
V/f Characteristics
Inputs signals
Output signals
Standard functions
Functionality
Analogue inputs
Braking/acceleration times
Display
Motor overload protection Electronic thermal overload relay
Instantaneous overcurrent Motor coasts to a stop at approx. 250% of inverter rated current
Overload
Overvoltage Motor coasts to a stop if DC bus voltage exceed 410 V (double for 400 V class)
Undervoltage
Momentary power loss
Cooling fin overheat Protected by thermister
Protection functions
Stall prevention level Stall prevention during acceleration/deceleration and constant speed operation
Ground fault Protected by electronic circuit (operation level is approx. 250% of rated output current)
Power charge indication Indicates until the main circuit voltage reaches 50 V.
Degree of protection
Cooling
Ambient humidity
Storage temperature
Installation
Installation height
Ambient conditions
Vibration
Short-term average deceleration torque: 150% (up 1.5 kW), 100% (for 1.5 kW), 50% (for 2.2 kW), 20% (fof bigger size)
Continous regenerative torque: Aprox 20% (125% with optional braking resistor, 10%ED, 10 s, braking transistor built itn)
Seven of the following input signals are selectable: Forward/reverse run (3-wire sequence), fault reset, external fault (NO/NC
contact input), multi-step speed operation, Jog command, accel/decel time select, external baseblock, speed search com-
mand, UP/DOWN command, accel/decel hold command, LOCAL/REMOTE selection, communication/control circuit terminal
Following output signals are selectable (NO/NC contact output, 2 photo-coupler outputs): Fault, running, zero speed, speed agree, frequency detection (output frequency <= or => set value), during overtorque detection, minor error, during baseblock, operation mode, inverter run ready, during fault retry, during undervoltage detection, reverse running, during speed search,
Open-loop vector control, full-range automatic torque boost, slip compensation, 17-step speed operation (max.), restart after momentary power loss, DC injection braking current at stop/start (50% of inverter rated current, 0.5 sec, or less), frequency reference bias/gain, MEMOBUS communications (RS-485/422, max. 115K bps), fault retry, speed search, frequency upper/ lower limit setting, overtorque detection, frequency jump, accel/decel time switch, accel/decel prohibited, S-curve accel/decel,
Heavy Duty: Motor coasts to a stop after 1 minute at 150% of inverter rated output current
Normal Duty: Motor coasts to a stop after 1 minute at 120% of inverter rated output current
Following items are selectable: not provided (stop if power loss is 15 ms or longer), continuous operation if power loss is
Sine wave PWM (V/f control, sensorless current vector control)
Digital set value: ±0.01% (-10..+50 ºC)
Analogue set value: ±0.1% (25 ±10 ºC)
Digital set value: 0.01 Hz (<100 Hz), 0.1 Hz (>100 Hz)
Analogue set value: 1/1000 of maximum frequency
Heavy duty use: 150% rated output current for one minute
Normal duty use: 120% rated output current for one minute
0..10 V (20 kΩ), 4..20 mA (250 Ω), 0..20 mA (250 Ω)
Pulse train input, frequency setting value (selectable)
Possible to program any V/f pattern
selection, mergency stop fault, emergency stop alarm, self test
data output through communication.
PID control, energy-saving control, constant copy.
2 analogue inputs, 0..10 V, 4..20 mA, 0..20 mA
Optionally frequency, current or set value
Stops when DC bus voltage is approx. 190 V or less (double for 400 V class)
Cooling fan is provided for 200 V, 0.75 kW (1HP) (3/single-phase)
Up to 9.8 m/s2 at 10 to less than 20 Hz, Up to 6.37 m/s2 at 20 to 50 Hz
(approx. 150 V or less for single-phase series)
approx. 0.5 s or shorter, continuous operation
400 V, 1.5 kW (2HP) (3-phase), others are self-cooling
95% RH or less (without condensation)
-20 ºC..+60 ºC (short-term temperature during transportation)
Indoor (no corrosive gas, dust, etc.)
Specifications
0.1..400 Hz
0.01 Hz
0.01..6000 s
Error and status LED
IP20, NEMA1
Max. 1000 m
V1000 3
Dimensions
IP 20 type 0.1 to 4 kW
W1
2-M4
H1H2
Figure 1
H
Figure 2
t1
W1
4-M4
H
Voltage class
Single-phase
200 V
Three-phase
200 V
Three-phase
400 V
W
Max. applicable
motor output kW
0.12 B0P1
0.25 B0P2 0.7
0.55 B0P4 108
0.12 20P1
0.25 20P2 0.6
0.55 20P4 108
0.37 40P2
0.55 40P4 99 28 1.0
D1
D
Inverter model VZA@ Figure
156
W
H2 H1
D
Dimensions in mm
W1 H1 W H D t1 H2 D1 H3 H4 Weight
68
76 3
6.5
t1
D1
0.6
38.5 1.0
1.1 B0P7
1.5 B1P5 154 1.8
2.2 B2P2 128 140 163
2
118
96 108
4.0 B4P0 158 170 180 3.0
156
1.1 20P7 128 1.1
1.5 21P5
2.2 22P2 137.5 1.4
96 108
2
68
118
128
128
137.5
76 3
129
5
5
58
--
65
6.5
38.5
5
5
--
58
1.7
2.4
0.6
0.9
1.3
4.0 24P0 128 140 143 65 2.1
5.5 25P5
7.5 27P5 3.8
11 2011 160 284 180 290 163 8 75
15 2015 192 336 220 358 187 7 78 7.2 9.2
1.1 40P7 137.5
1.5 41P5
2.2 42P2 1.5
122 248 140 254 140
3
96
2
118
108
128
81
154
65513
-
55
10
58
15
--
3.8
6.2
5.5
0.8
1.4
1.5
3.0 43P0 1.5
4.0 44P0 128 140 143 65 2.1
5.5 45P5
7.5 47P5 6.2 3.8
11 4011
15 4015 163 75 5.5
122 248 140 254 140
3
160 284 180 290
143
6
-
55
8156
13
63.8
5.2
V1000 + Option board (Communication and 24V DC power supply)
34
118
Communication option boards PS-V10S PS-V10M 24V DC Power supply Options
34
128
4 Frequency inverters
Built-in Filter Dimensions
VZA@
B0P1
B0P2
B0P4 79.5 38.5 118
B0P7
B1P5 89.4 64.6 154
B2P2
B4P0 40P2
40P4 29.6 99 40P7 41P5 42P2 43P0 44P0 45P5 47P5
4011 4015
W H H1 D1 D2 D
68+
108
140 183 55 96.4 66.6 163
108 178 50
140 183 55 76.4 66.6 143
Dimensions in mm
178 50
Under development
Under development
69.5 6.5 76
77.9 59.6 137.5
69.4 11.6 81
77.9
94.4 154
137.5
59.6
Schaffner footprint Filters
Schaffner model
A1000-FIV2010-SE 194 82 50 160 181 62 5.3 M5 25 56 118 M4
A1000-FIV2020-SE 169 111 50 135 156 91 5.5 M5 25 96 118 M4
3x200 V
1x200 V A1000-FIV1010-SE 169 71 45 135 156 51 5.3 M5 22 56 118 M4 0.44
3x400 V
A1000-FIV2030-SE 174 144 50 135 161 120 5.3 M5 25 128 118 M4
A1000-FIV2050-SE
A1000-FIV2100-SE
A1000-FIV1020-SE 169 111 50 135 156 91 5.3 M5 25 96 118 M4 0.75
A1000-FIV1030-SE 174 144 50 135 161 120 5.3 M5 25 128 118 M4 1.1
A1000-FIV1040-SE 174 144 50 135 161 150 5 M5 25 158 118 M4 1.3
A1000-FIV3005-SE 169 111 45 135 156 91 5.3 M5 22 96 118 M4 0.5
A1000-FIV3010-SE 169 111 45 135 156 91 5.3 M5 22 96 118 M4 0.7
A1000-FIV3020-SE 174 144 50 135 161 120 5 M5 25 128 118 M4 0.9
A1000-FIV3030-SE 304 184 56 264 288 150 6 M5 28 164 244 M5 1.8
A1000-FIV3050-SE 340 175 65 300 325 130 6 M6 32.5 160 285 M5 2.7
A B C D E F G H I J K L
Dimensions
Under developmentA1000-FIV2080-SE
Weight
KG
V1000 5
Rasmi footprint Filters
3x200 V
1x200 V A1000-FIV1010-RE 71 45 169 156 51 M4 0.6
3x400 V
Remote LCD operator
Rasmi model
W H L X Y M
Dimensions
A1000-FIV2010-RE 82 50 194 181 62 M4 0.8
A1000-FIV2020-RE 111 50 194 181 62 M4 1.1
A1000-FIV2030-RE 144 50 174 161 120 M4 1.3
A1000-FIV2060-RE 150 52 320 290 122 M5 2.4
A1000-FIV2080-RE 188 62 362 330 160 M5 4.2
A1000-FIV2100-RE 220 62 415 380 192 M6 -
A1000-FIV1020-RE 111 50 169 156 91 M4 1.0
A1000-FIV1030-RE 144 50 174 161 120 M4 5.3
A1000-FIV1040-RE 174 50 174 161 150 M4 -
A1000-FIV3005-RE 111 45 169 156 91 M4 1.1
A1000-FIV3010-RE 111 45 169 156 91 M4 1.1
A1000-FIV3020-RE 144 50 174 161 120 M4 1.3
A1000-FIV3030-RE 150 52 306 290 122 M5 2.1
A1000-FIV3050-RE 182 62 357 330 160 M5 2.9
Installation holes (2-M3 screws, depth 5 (0.19))
78 (3.07)
90 (3.54)
12.2
(0.48)
1.6 (0.06)
Weight
KG
15
<1>
60 (2.36)
7.9
(0.31)
minimum 50 (1.96) Unit : mm (in)
Chokes
Description D
diameter
A1000-FEV2102-RE 21 < 2.2 85 22 46 70 - 5 0.1 A1000-FEV2515-RE 25 < 15 105 25 62 90 - 5 0.2
Motor
KW
Dimensions Weight
L W H X Y m
(0.59)
Kg
44 (1.73)
X
YW
Ø m
L
A1000-FEV5045-RE 50 < 45 150 50 110 125 30 5 0.7
H
Ø d
6 Frequency inverters
Loading...
+ 12 hidden pages