Thank you for purchasing the OMRON M7 Intelli IT Automatic Upper Arm Blood Pressure Monitor.
The OMRON M7 Intelli IT is a compact, fully automatic upper arm blood pressure monitor, operating on the oscillometric principle. It measures your blood pressure and pulse rate simply
and quickly. For comfortable controlled inflation without the need of pressure pre-setting or re­inflation the device uses its advanced “IntelliSense” technology.
Intended Use
This device is a digital monitor intended for use in measuring blood pressure and pulse rate in adult patient population who can understand this instruction manual with the arm circumference range printed on the arm cuff. The device detects the presence of irregular heartbeats during measurement and gives a warning signal with the measurement result.
Please follow this instruction manual thoroughly for your safety. Please keep for future reference. For specific information about your own blood pressure, CONSULT YOUR PHYSICIAN.
Important Safety Information .......................... 1
1 Know Your Device...................................... 5
1.1 Display Symbols ........................................ 6
1.2 Before Taking a Measurement................... 7
2 Preparation ................................................. 8
2.1 Battery Installation ..................................... 8
2.2 Pairing this Monitor with a Smartphone ..... 9
3 Using the Device ...................................... 13
3.1 Applying the Arm Cuff............................ 13
3.2 How to Sit Correctly............................... 14
3.3 Taking a Measurement.......................... 15
3.4 Using the Memory Function................... 20
3.5 Turning “OFF” the Bluetooth
®
................ 25
3.6 Initial Setting of the Monitor ................... 27
4 Error Messages and Troubleshooting.... 28
4.1 Error Messages ..................................... 28
4.2 Troubleshooting..................................... 30
5 Maintenance and Storage........................ 32
5.1 Maintenance .......................................... 32
5.2 Storage .................................................. 33
5.3 Optional Medical Accessories ............... 34
6 Specifications ........................................... 36
7 Trademark ................................................. 41
8 Warranty.................................................... 42
9 Some Useful Information about Blood
Pressure .................................................... 43
1
EN
Important Safety Information
Warning: Indicates a potentially hazardous situation which, if not avoided, could result in death or
serious injury.
(General Usage)
DO NOT adjust medication based on measurement results from this blood pressure monitor. Take medication as prescribed by your physician. Only a physician is qualified to diagnose and treat high blood pressure.
Consult your physician before using the device for any of the following conditions: common arrhythmias such as atrial or ventricular premature beats or atrial fibrillation, arterial sclerosis, poor perfusion, diabetes, age, pregnancy, pre-eclampsia, renal diseases. Note that PATIENT motion, trembling, shivering may affect the measurement reading.
Do not use the device on an injured arm or an arm under medical treatment. Stop using the device and consult your physician if you experience skin irritation or other troubles. Do not apply the arm cuff on the arm while being on an intravenous drip or blood transfusion.
Consult your physician before using the device on the arm with an arterio-venous (A-V) shunt. Do not use the device with other medical electrical (ME) equipment simultaneously.
Do not use the device in the area of high frequency (HF) surgical equipment, magnetic resonance imaging (MRI), or computerized tomography (CT) scanner exists, or in the oxygen rich environment.
The air tube or the AC adapter cable may cause accidental strangulation in infants. Contains small parts that may cause a choking hazard if swallowed by infants.
(Data Transmission)
Do not use this product on an aircraft or in hospitals. Please remove the battery and AC adapter from the device. Turn off the Bluetooth
®
of the monitor in those areas where use of wireless equipment is prohibited. This product emits radio frequencies (RF) in the 2.4 GHz band, use of this product in locations where RF is restricted is not recommended.
2
Important Safety Information
(AC Adapter (optional) Usage)
Do not use the AC adapter if the device or the power cord is damaged. Turn off the power and unplug the power cord immediately.
Plug the AC adapter into the appropriate voltage outlet. Do not use in a multi-outlet plug. Never plug in or unplug the power cord from the electric outlet with wet hands.
Do not disassemble or attempt to repair the AC adapter.
(Battery Usage)
Keep the battery out of reach of children.
Caution: Indicates a potentially hazardous situation which, if not avoided, may result in minor or
moderate injury to the user or patient or damage to the equipment or other property.
(General Usage)
Always consult your physician. Self-diagnosis of measurement results and self-treatment are dangerous. Consult your physician before using the device for any of the following conditions:
• If you have had a mastectomy.
• People with severe blood flow problems or blood disorders as cuff inflation can cause bruising. Do not take measurements more often than necessary. It may cause bruising due to blood flow interference.
Remove the arm cuff if it does not start deflating during the measurement. Do not use this device on infants or persons who cannot express their intentions.
Do not use the device for any purpose other than measuring blood pressure. Use only the approved arm cuff for this device. Use of other arm cuffs may result in incorrect measurement
results. Do not use a mobile phone or other devices that emit electromagnetic fields near the device except when in use
for wireless communications. This may result in incorrect operation of the device. Do not disassemble the monitor or arm cuff. This may cause an inaccurate reading.
3
Important Safety Information
EN
Do not use in a location with moisture, or a location where water may splash on the device. This may damage the device.
Do not use the device in a moving vehicle. For example, the car or airplane. Read “What to do if your systolic pressure is more than 210 mmHg” (page 16) of this instruction manual, if your
systolic pressure is known to be more than 210 mmHg. Inflating to a higher pressure than necessary may result in bruising of the arm where the cuff is applied.
(Data transmission)
Do not replace the battery or unplug the AC adapter when in use for wireless communications. This may result in incorrect operation of the device or damage to the data.
Do not place integrated circuit cards, magnets, metal objects, or other devices that emit electromagnetic fields near the device when in use for wireless communications. This may result in incorrect operation of the device or damage to the data.
(AC Adapter (optional) Usage)
Fully insert the power plug into the outlet. When disconnecting the power plug from the outlet, be sure to safely pull from the power plug. Do not pull from
the power cord. When handling the power cord, take care not to do the following:
Wipe any dust off of the power plug. Unplug the monitor when not in use. Disconnect the power plug before cleaning. Use only an OMRON AC adapter designed for this device. Use of unsupported adapters may damage and/or
may be hazardous to the device.
Do not damage. Do not break it. Do not tamper with it. Do not forcibly bend or pull. Do not twist. Do not bundle during use. Do not pinch. Do not place under heavy objects.
4
Important Safety Information
(Battery Usage)
Do not insert the batteries with their polarities incorrectly aligned. Use only 4 “AA” alkaline or manganese batteries with this device. Do not use other types of batteries. Do not
use new and used batteries together. Remove the batteries if the device will not be used for three months or more. If battery fluid should get in your eyes, immediately rinse with plenty of clean water. Consult a physician
immediately. Use the battery within recommended period mentioned to it.
General Precautions
• Do not forcibly crease the arm cuff or the air tube excessively.
• Do not fold or kink the air tube while taking a measurement. This may cause harmful injury by interrupting blood flow.
• To unplug the air plug, pull on the air plug at the connection with the monitor, not the tube itself.
• Do not drop the monitor or subject the device to strong shocks or vibrations.
• Do not inflate the arm cuff when it is not wrapped around your arm.
• Do not use the device outside the specified environment. It may cause an inaccurate reading.
• Please check (for example, by observation of the limb concerned) if the device is not causing a prolonged impairment of PATIENT blood circulation.
• Read and follow the “Important information regarding Electro Magnetic Compatibility (EMC)” in the “6. Specifications”.
• Read and follow the “Correct Disposal of This Product” in “6. Specifications” when disposing of the device and any used accessories or optional parts.
5
EN
1. Know Your Device
Monitor
Display Cuff wrap guide lamp Memory button Weekly average button START/STOP button Up/Down buttons USER ID selection switch Connection button Blood pressure level indicator
(colour) Air jack Battery compartment AC adapter jack (for optional AC adapter)
Arm cuff
Arm cuff (Arm circumference 22-42cm) Air plug
Air tube
Display
Memory symbol USER ID symbol
Average value symbol Systolic blood pressure Diastolic blood pressure Connection symbol DATA/FULL symbol OK symbol Heartbeat symbol
(Flashes during measurement)
Date/Time display Morning average symbol Evening average symbol Morning hypertension symbol Movement error symbol Irregular heartbeat symbol Blood pressure level indicator
(bar)
Cuff wrap guide symbol Battery symbol
(low/depleted)
Deflation symbol Pulse display / Memory number
Open the rear cover page to read the following:
The letter identifiers on the rear cover page correspond to those in the body of this page.
A
BCD
E
F
GHI
J
K
L
M
N
O
P
Q
R
S
T
U
V
WXY
Z
AA
AB
AC
AD
AE
AF
AG
AH
AI
6
1. Know Your Device
1.1
Display Symbols
Irregular Heartbeat Symbol ( )
When the monitor detects an irregular rhythm two or more times during the measurement, the irregular heartbeat symbol will appear on the display with the measurement values.
An irregular heartbeat rhythm is defined as a rhythm that is 25% less or 25% more than the average rhythm detected while the monitor is measuring the systolic and diastolic blood pressure.
If the irregular heartbeat symbol displays with your measurement results, we recommend you consult your physician. Follow the directions of your physician.
Movement Error Symbol ( )
The movement error symbol is displayed if you move your body during the measurement. Please remove the arm cuff, and wait 2-3 minutes. Take another measurement, remain still during measurement.
Average Value Symbol ( )
The average value symbol is displayed when you press and hold the memory button for more than 3 seconds. The most recent average value appears on the display screen.
Cuff Wrap Guide Lamp ( /)
If the cuff was wrapped too loosely, it may cause unreliable results. If the wrapping of cuff is too loose, the cuff wrap guide Lamp lights in orange. Otherwise lights in green. This is the function which is used as an aid in determining if the cuff is wrapped snugly enough.
Normal Heartbeat
Irregular Heartbeat
Pulse
Blood pressure
Blood pressure
Short
Long
Pulse
7
1. Know Your Device
EN
Blood Pressure Level Indicator (Colour)
If your Systolic Blood Pressure is 135 mmHg or above and/or the Diastolic Blood Pressure is 85 mmHg or above, the blood pressure level indicator (colour) will light in orange when the measurement result is displayed. If the measurements are within the standard range, the blood pressure level indicator (colour) will light in green.
2013 ESH/ESC Guidelines for the management of arterial hypertension
Definitions of hypertension by office and home blood pressure levels
1.2
Before Taking a Measurement
To help ensure an accurate reading, follow these directions:
1. Avoid bathing, drinking alcohol or caffeine, smoking, exercising and eating for 30 minutes before taking a measurement.
2. Rest for at least 5 minutes before taking the measurement.
3. Stress raises blood pressure. Avoid taking measurements during stressful times.
4. Measurements should be taken in a quiet place.
5. Remove tight-fitting clothing from your arm.
6. Keep a record of your blood pressure and pulse readings for your physician. A single measurement does not provide an accurate indication of your true blood pressure. You need to take and record several readings over a period of time. Try to measure your blood pressure at the same time each day for consistency.
Office Home
Systolic Blood Pressure 140 mmHg 135 mmHg
Diastolic Blood Pressure 90 mmHg 85 mmHg
8
2. Preparation
2.1
Battery Installation
1. Remove the battery cover.
2. Insert 4 “AA” batteries as
indicated, into the battery compartment.
3. Replace the battery cover.
Notes:
• When the depleted battery symbol ( ) appears on the display, turn the monitor off and remove all the batteries. Replace with 4 new batteries at the same time. Long life alkaline batteries are recommended.
• After replacing batteries, “-/ - -:--” appears on the Date/Time display during or after measurement. Before taking a first measurement, the monitor needs to be set with the correct date and time. Measurements taken without date and time settings will not sync. For setting the date and time manually, please refer to “To Set the Date and Time Manually” in section 2.2.
• The measurement values continue to be stored in memory even after the batteries are replaced.
• The supplied batteries may have a shorter life than new batteries.
Disposal of used batteries should be carried out in accordance with the national/local regulations for
the disposal of batteries.
9
2. Preparation
EN
2.2
Pairing this Monitor with a Smartphone
To begin using the “OMRON connect” app for the first time, please visit www.omronconnect.com/setup
for the initial set-up instructions.
1. Download and install the free “OMRON connect” app
on your smartphone.
Note: If you already have the “OMRON connect” app, go to:
Menu > Device > Add Device
2. Open the app on your smartphone and follow set-up
and pairing instructions.
List of Compatible Smartphones at: www.omronconnect.com/devices
For details, visit: www.omronconnect.com
10
2. Preparation
3. Press the connection button for more than 2
seconds.
The connection symbol ( ) and the “P” flashes on
the display of the monitor.
4. Follow the pairing instructions shown on your
smartphone, while the connection symbol is flashing on the display of the monitor.
11
2. Preparation
EN
5. Confirm if the monitor is connected
successfully.
When the monitor is connected successfully to the smartphone, OK symbol ( ) and the display shown on the right will flash.
The monitor will automatically turn off without any operations.
The date and time setting of your monitor will automatically sync with your smartphone when paired.
When “Err” appears, refer to “Connection failure. /
Data cannot be sent.” in section 4.2 for more detail.
Notes:
• This monitor can pair to multiple smartphones to support for 2 people using USER ID 1 and USER ID 2.
• Any readings previously saved in the memory of blood pressure monitor will automatically be transferred to the app after successful completion of the pairing process.
12
2. Preparation
To Set the Date and Time Manually
The date and time will be automatically set when paired with your smartphone. To set manually, follow the instructions below.
1. Press the connection button once.
The connection symbol ( ) and the “ ” flash on the display of the monitor.
Note: If pairing has not been completed, the display to the right will not appear.
Please continue to step 3 and skip step 2.
2. Then press the connection button again.
The year flashes on the Date/Time display.
3. Push or button to change the year.
Push button to confirm the year and then the month flashes. Repeat the same steps to change the month, day, hour, and minute.
4. Press the [START/STOP] button to turn the monitor off.
Year Month Day Hour Minute
Change Confirm Change Confirm Change Confirm Change Confirm Change Confirm
: Back : Forward