Omron HL-5000 DATASHEET

Omron HL-5000 DATASHEET

General-purpose Limit Switch HL-5000

Economical, Miniature Limit Switch

Boasting Rigid Construction

Highly rigid construction (head and cover snugly fit in box).

Dustproof and drip-proof construction.

Smooth operation with greater OT.

Easy-to-wire conduit opening design.

Models with grounding terminals conform to the CE marking.

Ordering Information

Model Number Legend

HL-5jjj

1 2 3

1. Actuators

000: Roller lever

030: Adjustable roller lever

050: Adjustable rod lever 100: Sealed plunger

200: Sealed roller plunger 300: Coil spring

500: Remote control wire

2. Ground Terminal Specifications

Blank: Without ground terminal

G:With ground terminal/M5 tapping on the rear side

3. Contact

Blank: Standard (silver rivet contact)

A:Gold plating

List of Models

Actuator

Roller lever

Adjustable

Adjustable

Sealed

Sealed roller

Coil spring

 

 

roller lever

rod lever

plunger

plunger

 

 

 

 

 

 

 

 

Model

HL-5000

HL-5030

HL-5050

HL-5100

HL-5200

HL-5300

Note: HL-5000 Limit Switches are offered with a choice of ground terminal/M5 tapping on the rear side conforming to various standards.

When placing an order, add the code to the model number to indicate if ground terminal/M5 tapping on the rear side is required.

-G: with ground terminal/M5 tapping on the rear side

1

HL-5000 HL-5000

Specifications

Ratings

Rated voltage

 

 

 

Non-inductive load

 

 

 

Inductive load

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Resistive load

 

Lamp load

 

Inductive load

Motor load

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NC

 

NO

NC

NO

 

NC

NO

NC

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

125 VAC

 

5 A

 

 

1.5 A

0.7 A

3 A

 

 

2 A

1 A

 

 

 

 

 

 

 

 

 

 

 

 

 

250 VAC

 

5 A

 

 

1 A

0.5 A

3 A

 

 

1.5 A

0.8 A

 

 

 

 

 

 

 

 

 

 

 

 

 

12 VDC

 

5 A

 

 

3 A

 

4 A

 

 

3 A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24 VDC

 

5 A

 

 

3 A

 

4 A

 

 

3 A

 

 

 

 

 

 

 

 

 

 

 

 

 

Inrush current

NC

 

24 A max.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

 

12 A max.

 

 

 

 

 

 

 

 

Note: 1. The above figures are for standard currents.

2.Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).

3.Lamp load has an inrush current of 10 times the steady-state current.

4.Motor load has an inrush current of 6 times the steady-state current.

Characteristics

Degree of protection

IP65

 

 

 

 

Life expectancy (see note 3)

Mechanical:

10,000,000 operations min. (under rated conditions)

 

Electrical:

See the following Electrical Life Expectancy.

Operating speed

5 mm/s to 0.5 m/s (HL-5000)

 

 

 

Operating frequency

Mechanical:

120 operations/min

 

Electrical:

30 operations/min

 

 

Insulation resistance

100 MΩ min. (at 500 VDC)

 

 

Contact resistance

25 mΩ max. (initial value)

 

 

Dielectric strength

1,000 VAC, 50/60 Hz for 1 min between terminals of the same polarity

 

1,500 VAC, 50/60 Hz for 1 min between current-carrying metal parts and ground, and between

 

each terminal and non-current-carrying metal part

 

 

 

Rated frequency

50/60 Hz

 

 

 

Vibration resistance

Malfunction: 10 to 55 Hz, 1.5-mm double amplitude

 

 

Shock resistance

Destruction: 1,000 m/s2 min.

 

Malfunction: 300 m/s2 min.

Ambient temperature

Operating: –5° C to 65° C (with no icing)

 

 

Ambient humidity

Operating: 95% max.

 

 

Weight

Approx. 130 to 190 g

Note: 1. The above figures are initial values.

2.The above characteristics may vary depending on the model. For further details, contact your OMRON sales representative.

3.Life expectancy values are calculated at an operating temperature of 5° C to 35° C, and an operating humidity of 40% to 70%. Contact your OMRON sales representative for more detailed information on other operating environments.

Contact Form

(4)(3)

NO

NO

NC

NC

(1)(2)

2

HL-5000 HL-5000

Operating Characteristics

Model

HL-5000

HL-5030

HL-5050

HL-5100

HL-5200

HL-5300

HL-5500

 

 

(see note)

(see note)

 

 

 

 

 

 

 

 

 

 

 

 

OF max.

7.35 N

7.35 N

7.35 N

8.83 N

8.83 N

1.47 N

19.61 N

 

 

 

 

 

 

 

 

RF min.

0.98 N

0.98 N

0.98 N

1.47 N

1.47 N

---

1.96 N

 

 

 

 

 

 

 

 

PT max.

20°

20°

20°

1.5 mm

1.5 mm

30 mm

1.5 mm

OT min.

50°

50°

50°

4 mm

4 mm

---

4.5 mm

MD max.

12°

12°

12°

1 mm

1 mm

---

0.7 mm

OP

---

 

 

30± 0.8 mm

40± 0.8 mm

---

---

Note: 1. Measured with the types of the 31.5-mm arm or rod length.

 

 

 

2. OF and RF measured at the arm length of 75 mm for HL-5030, and 145 mm for HL-5050 (reference values).

 

Model

HL-5030

HL-5050

 

 

 

OF

3.09 N

1.60 N

 

 

 

RF

0.41 N

0.22 N

Engineering Data

Reference Data

Electrical Life Expectancy (cosφ =1)

Operating temperature: 5° C to 30° C

Operating humidity: 40% to 70%

Life expectancy (x 104 operations)

Operating frequency: 30 operations/min 125 VAC (cosφ = 1)

Switching current (A)

3