Thank you for purchasing the Omron®HEM-712C IntelliSense
Automatic Blood Pressure Monitor.
Fill in for future reference.
DATE PURCHASED: __________________
SERIAL NUMBER: ____________________
Staple your purchase receipt here
®
Your new digital blood pressure monitor uses the oscillometric method
of blood pressure measurement. This means the monitor detects your
blood’s movement through your brachial artery and converts the
movements into a digital reading. An oscillometric monitor does not
need a stethoscope so the monitor is simple to use.
The HEM-712C comes with the following components:
• Monitor
• Standard Adult Arm Cuff 9''-13'' arm circumference
• Instruction Manual in English and Spanish
®
The HEM-712C IntelliSense
is intended for home use.
Automatic Blood Pressure Monitor
SAVE THESE INSTRUCTIONS
3
IMPORTANT SAFETY NOTES
To assure the correct use of the product basic safety measures should
always be followed including the precautions listed below:
þ Read all information in the instruction book and any other literature
included in the box before using the unit.
þ Contact your physician for specific information about your blood
pressure. Follow the instructions of your healthcare provider.
þ Operate the unit only as intended. Do not use for any other purpose.
þ The unit is intended for use in measuring blood pressure and pulse
rate in adult patient population. Do not use on infants or persons who
cannot express their intentions.
þ Do not use a cellular phone near the unit. It may result in
operational failure.
þ Changes or modifications not approved by Omron Healthcare will
void the user warranty. Do not disassemble or attempt to repair the
unit or components.
4
BEFORE TAKING A MEASUREMENT
To ensure a reliable reading follow these recommendations:
1. Avoid eating, drinking alcohol, smoking, exercising, and bathing
for 30 minutes before taking a measurement. Rest for at least
15 minutes before taking the measurement.
4. Remove tight-fitting clothing from your left arm.
5. Sit in a chair with your feet flat on the floor. Rest your left arm on
a table so that the cuff is at the same level as your heart.
6. Remain still and do not talk during the measurement.
7. Keep a record of your blood pressure and pulse readings for your
physician. A single measurement does not provide an accurate
indication of your true blood pressure. You need to take and record
several readings over a period of time. Try to measure your blood
pressure at the same time each day for consistency.
8. Wait 2-3 minutes between measurements. The wait time allows the
arteries to return to the condition prior to taking the blood pressure
measurement. You may need to increase the wait time depending on
your individual physiological characteristics.
5
Main Unit:
KNOW YOUR UNIT
Display
Battery Compartment
START/STOP
Button
MEMORY Button
Date/Time Setting Button
Components:
Arm Cuff
Air Jack
AC Adapter Jack
Air Tube
Air Plug
(Connects to Air Jack)
6
Systolic Blood Pressure
Diastolic Blood Pressure
UNIT DISPLAY
Memory Symbol
Average Value Symbol
Low Battery Symbol
Irregular Heartbeat Symbol
Heartbeat Symbol
Pulse Display
Deflation Symbol
Date/Time Display
IRREGULAR HEARTBEAT SYMBOL
IRREGULAR HEARTBEAT SYMBOL
When the monitor detects an irregular rhythm two or more than two
times during the measurement, the Irregular Heartbeat Symbol ( )
will appear on the display with the measurement values.
An irregular heartbeat rhythm is defined
as a rhythm that varies by less than 25%
from the average rhythm or 25% more than
the average rhythm detected while the
monitor is measuring the systolic and
diastolic blood pressure.
If the irregular heartbeat symbol ( )
displays with your measurement results we
recommend you consult your physician.
Follow the directions of your doctor.
Normal Heartbeat
Pulse
Blood
pressure
Irregular Heartbeat
ShortLong
Pulse
Blood
pressure
7
BATTERY INSTALLATION
1. Press the
and slide the cover off in the direction of
the arrow.
2. Install 4 “AA” size batteries so the
+ (positive) and - (negative) polarities
match the polarities of the battery
compartment as indicated.
3. Replace the battery cover.
▲ indicator on the battery cover
BATTERY REPLACEMENT
Low Battery Symbol
Initial Set-Up
When the Low Battery Symbol () appears on the display screen
remove all the batteries. Replace with four new batteries at the same
time. When the Low Battery Symbol () blinks a brief period of usage
remains. Long-life alkaline batteries are recommended.
NOTES:
•Measurement values stored in the memory will not be deleted during
battery replacement.
•After replacing the batteries, reset the date and time. Refer to page
10, Setting the Date and Time.
•Dispose of batteries according to applicable local regulations.
8
SETTING THE DATE AND TIME
Set the monitor to the current date and time before taking a measurement
for the first time. If the correct date and time are not set, the measurement
values stored in the memory and the average value will not be correct.
The Blood Pressure Monitor automatically stores up to 30 measurement
values with the date and time. The monitor also calculates an average
reading based on the three most recent measurements taken within 10
minutes of the last reading.
NOTES:
• If only two readings are stored in the memory for the 10-minute
period, the average is based on the two readings.
• If one reading is stored in the memory for the 10-minute period,
this reading is displayed as the average.
1. TO START THE SETTING
Press the Date/Time Setting button to
adjust the date and time.
The year flashes on the display.
9
SETTING THE DATE AND TIME
2. SETTING THE YEAR
The year can be set between 2005 and
2030. When the display reaches 2030,
it will return to 2005.
Press the MEMORY button to advance
by increments of one year.
Press the Date/Time Setting button to set
the current year.
The month flashes on the display.
NOTE:
• Press and hold the MEMORY button to advance
the date and time values faster.
3. SETTING THE MONTH
Press the MEMORY button to advance by
increments of one month.
Press the Date/Time Setting button to set
the current month.
The day flashes on the display.
4. SETTING THE DAY
Press the MEMORY button to advance by
increments of one day.
Press the Date/Time Setting button to set
the current day.
The hour flashes on the display.
10
SETTING THE DATE AND TIME
5. SETTING THE HOUR
The time is set using AM or PM.
Press the MEMORY button to advance
by increments of one hour.
Press the Date/Time Setting button to set
the current hour.
The minutes flash on the display.
6. SETTING THE MINUTE
Press the MEMORY button to advance by
increments of one minute.
Press the Date/Time Setting button to set
the current minute.
The year flashes on the display.
Press the START/STOP button to turn
the display off.
11
APPLYING THE ARM CUFF
1. Make sure the air plug is securely inserted
in the main unit.
2. Remove tight-fitting clothing from your upper arm.
3. Sit in a chair with your feet flat on the floor.
Place your arm on a table so the cuff is level with your heart.
12
APPLYING THE ARM CUFF
4. Apply the cuff to your left upper arm so the blue arrow is centered
on the inside of your arm and aligned with your middle finger.
The air tube runs down the inside of your arm. The bottom
of the cuff should be approximately 1/2" above your elbow.
1/2 inch (1 - 2 cm)
Arrow
Air Tube
5. Wrap the cuff firmly in place around your arm
using the closure strip.
APPLYING THE CUFF ON THE RIGHT ARM
When taking a measurement using the right arm use this instruction.
Apply the cuff to your right upper arm
so the blue arrow and the air tube runs
along the inside of your elbow. The bottom
of the cuff should be approximately 1/2''
above your elbow.
NOTE: Be careful not to rest your arm on the air tube. This will restrict
the flow of air to the cuff.
13
TAKING A MEASUREMENT
The monitor automatically determines your ideal inflation level.
In rare circumstances when a higher inflation may be necessary, the
monitor automatically re-inflates the cuff up to 30 mmHg higher than
the initial inflation and restarts the measurement.
Press the START/STOP button.
1.
All display symbols appear on the screen. The cuff starts to inflate
automatically.
As the cuff begins to inflate, the monitor automatically determines
your ideal inflation level. Because this monitor detects the pulse even
during inflation, do not move your arm and remain still until the
entire measurement process has been completed.
NOTE: To stop the inflation or measurement, push the
START/STOP button. The monitor will stop inflating,
start deflating, and will turn off.
2. Inflation stops automatically and
the measurement is started.
As the cuff deflates, decreasing
numbers appear on the display.
The Heartbeat Symbol ()
flashes at every heartbeat.
14
TAKING A MEASUREMENT
You3blood pressure and pulse rate are displayed.
3. When the measurement is complete, the arm
cuff completely deflates. Your blood pressure
and pulse rate are displayed.
4. Press the START/STOP button.
The monitor turns off.
NOTE: The monitor will automatically
turn off after five minutes.
INSTRUCTIONS FOR SPECIAL CONDITIONS
If your systolic pressure is known to be
more than 220 mmHg, press and hold the
START/STOP button until the monitor
inflates 30 to 40 mmHg higher than your
suspected systolic pressure.
NOTES:
• Do not apply more pressure than necessary.
• The monitor will not inflate above 299 mmHg.
15
USING THE MEMORY FUNCTION
Every time you complete a measurement the monitor stores the blood
pressure and pulse rate in the memory. The blood pressure monitor
automatically stores up to 30 measurement values. When 30 sets of
measurement values are stored in the memory, the oldest record is
deleted to save the most recent measurement values.
AVERAGING FUNCTION
The monitor also calculates an average reading based on the values of
the three most recent measurements that were taken within 10 minutes
of the most recent reading.
NOTES:
•If only two readings are stored in the memory for the
10-minute period, the average is based on the two readings.
•If one reading is stored in the memory for the 10-minute
period, this reading is displayed as the average.
If the date and time is not set, the measurement values and the average
value will not be stored in the memory correctly.
Press the MEMORY button
1.
The Average Value Symbol will display on the screen with the
average reading.
16
USING THE MEMORY FUNCTION
TO DISPLAY THE MEASUREMENT VALUES
The date and time is alternately displayed with the measurement values.
1. Press the MEMORY button to display the most recent
measurement values on the screen.
Alternating display
NOTES:• Press the button repeatedly to display the next values.
• Press and hold the button to display the values faster.
2.
Press the START/STOP button to turn the power off.
TO DELETE ALL VALUES STORED IN THE MEMORY
You cannot partially delete records stored in the memory.
All records will be deleted.
1.
2.While holding the
Press the MEMORY button.
MEMORY and the START/STOP button
simultaneously for more than 2 seconds all records will be deleted.
17
Loading...
+ 39 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.