Omron HEM-7221 Instruction Manual

HEM-7221-C1_C_M02_101122.pdf
HEM-7221-C1_C_M.book Page 1 Monday, November 22, 2010 1:19 PM
All for Healthcare
Automatic Blood Pressure Monitor
Model HEM-7221
Instruction Manual
Contents
Before using the unit
Introduction ................................................................................ 3
Important Safety Information ....................................................4
1. Overview ............................................................................... 7
2. Preparation ......................................................................... 10
2.1 Installing/Replacing the Batteries ..............................................10
2.2 Setting the Date and Time .........................................................11
Operating instructions
3. Using the Unit ..................................................................... 12
3.1 Applying the Arm Cuff ................................................................12
3.2 How to Sit Correctly ...................................................................14
3.3 Taking a Reading .......................................................................15
3.4 Using the Memory Function .......................................................18
4. Troubleshooting and Maintenance .................................. 20
4.1 The Icons and Error Messages ..................................................20
4.2 Troubleshooting .........................................................................22
4.3 Maintenance ..............................................................................24
4.4 Storage ......................................................................................25
Care and maintenance
5. Optional Parts ....................................................................26
6. Technical Data .................................................................... 27
HEM-7221-C1_C_M.book Page 2 Monday, November 22, 2010 1:19 PM
Before using the unit
Introduction
Thank you for purchasing the
Intended Use
This product is designed to measure the blood pressure and pulse rate of people within the range of the designated arm cuff, following the instructions in this instruction manual. It is mainly designed for general household use. Please read the Important Safety Information in this instruction manual before using the unit.
OMRON HEM-7221 Automatic Blood
Pressure Monitor.
The OMRON HEM-7221 is a compact, fully automatic blood pressure monitor, operating on the oscillometric principle. It measures your blood pressure and pulse rate simply and quickly. Equipped with Dual Check System and Cuff Wrapping Guide, HEM-7221 provides accurate and anxiety-free blood pressure measurement everyday. For comfortable controlled inflation without the need of pressure pre­setting or re-inflation the devices uses its advanced “IntelliSense” technology.
Please read this instruction manual thoroughly before using the unit.
Please keep for future reference. For specific information about your own blood pressure,
CONSULT YOUR DOCTOR.
HEM-7221-C1_C_M.book Page 3 Monday, November 22, 2010 1:19 PM
Important Safety Information
Important Safety Information
Consult your doctor prior to using in pregnancy or if diagnosed with arrhythmia or arteriosclerosis.
Please read this section carefully before using the unit.
Warning:
Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
(General Usage)
Always consult your doctor. Self-diagnosis of measurement results and self­treatment are dangerous.
People with severe blood flow problems, or blood disorders, should consult a doctor before using the unit, as cuff inflation can cause int
ernal bleeding.
(Optional AC Adapter Usage)
Never plug in or unplug the power cord from the electric outlet with wet hands.
(Battery Usage)
If battery fluid should get in your eyes, immediately rinse with plenty of clean water. Consult a doctor immediately.
Caution:
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury to the user or patient or damage to the equipment or other property.
HEM-7221-C1_C_M.book Page 4 Monday, November 22, 2010 1:19 PM
Important Safety Information
(General Usage)
Do not leave the unit unattended with infants or persons who cannot express their consent.
Do not use the unit for any purpose other than measuring blood pressure.
Use only the approved arm cuff for this unit. Use of other arm cuffs may result
in incorrect measurement results.
Make sure that the air tube is not wrapped around other parts of your body when taking measurements. This could result in injury when the air pressure in the air tube is increased.
Do not leave the cuff wrapped on the arm if taking measurements during the night. This could result in
injury.
Do not inflate the arm cuff over 299 mmHg.
Do not use a mobile phone or other devices that emit electromagnetic fields,
near the unit. This may result in incorrect operation of the unit.
Do not operate the unit in a moving vehicle (car, airplane).
To inflate the cuff manually, refer to Section 3.3. If the cuff is over inflated, it
can cause internal bleeding.
(Optional AC Adapter Usage)
Use only the original AC adapter designed for this unit. Use of unsupported adapters may damage and/or may be hazardous to the unit.
Plug the AC adapter into the appropriate voltage outlet. Do not use
a multiple-
tap.
Do not use the AC adapter if the unit or the power cord is damaged. Turn off the power and unplug the power cord immediately.
HEM-7221-C1_C_M.book Page 5 Monday, November 22, 2010 1:19 PM
Important Safety Information
(Battery Usage)
If battery fluid should get on your skin or clothing, immediately rinse with plenty of clean water.
Use only four “AA” alkaline or manganese batteries with this unit. Do not use other types of batteries.
Do not insert the batteries with their polarities incorrectly aligned.
Replace old batteries with new ones immediately. Replace all four batteries at
the same time.
Remove the batteries if the unit will not be used for three months or more.
Do not use new and used batteries together.
General Precautions
Do not apply strong shocks and vibrations to or drop the unit and arm cuff.
Do not take measurements after bathing, drinking alcohol or caffeine,
smoking, exercising or eating.
Do not forcibly bend the arm cuff or bend the air tube excessively.
When removing the air tube, pull on the air plug at the connection with the
main unit not the tube itself.
Section when disposing of the device and any used accessories or optional parts.
• Read and follow the Correct Disposal of This Product in the Technical Data
Compatibility (EMC) in the Technical Data Section.
• Read and follow the Important information regarding Electro Magnetic
Do not inflate the arm cuff when it is not wrapped around your arm.
HEM-7221-C1_C_M.book Page 6 Monday, November 22, 2010 1:19 PM
1. Overview
1. Overview
Main Unit:
A. Display B. Memory button C. START/STOP button D. Up/Down ( / ) buttons E. Date/Time setting ( ) button F. Air Jack
G. Battery compartment H. AC adapter jack (for optional
AC adapter)
A
B C
D
E
F
G
HH
HEM-7221-C1_C_M.book Page 7 Monday, November 22, 2010 1:19 PM
1. Overview
Arm Cuff:
Storage case:
I. Blue Strip J. Air tube K. Air plug L. Grip M. Arm cuff
(Arm circumference 17-32 cm)
M
I
K
L
J
HEM-7221-C1_C_M.book Page 8 Monday, November 22, 2010 1:19 PM
1. Overview
Display:
N. Date/Time display O. Dual Check System P. Systolic blood pressure Q. Diastolic blood pressure R. Heartbeat symbol
(Flashes during measurement)
S. Battery low symbol
T. Average value symbol U. Memory symbol V. Irregular heartbeat symbol W. Movement error symbol X. Blood pressure level indicator Y. Deflation symbol Z. Cuff wrapping guide AA.Pulse display and Memory
number
N
O
P
Q
R
S
T
U
V
W
X
Z
AA
Y
HEM-7221-C1_C_M.book Page 9 Monday, November 22, 2010 1:19 PM
10
2. Preparation
2. Preparation
2.1 Installing/Replacing the Batteries
1. Remove the battery cover.
2. Insert four “AA” batteries as
indicated in the battery compartment and then replace the battery cover.
Notes:
• If the battery low symbol ( ) appears on the display, turn the unit off then replace all batteries at the same time.
• The measurement values continue to be stored in memory even after the batteries are replaced.
Disposal of used batteries should be carried out in accordance with the national regulations for the disposal of batteries.
HEM-7221-C1_C_M.book Page 10 Monday, November 22, 2010 1:19 PM
11
2. Preparation
2.2 Setting the Date and Time
1. Press the button.
2. Set the monitor to the correct date and time before taking a
measurement for the first time.
3. Press the START/STOP button to store the setting.
Notes:
• If the batteries have been removed for 30 seconds or more, the date and time setting will need to be reset.
• If the date and time are not set, “-:--” appears during or after measurement.
1)
2)
Push or buttons to change.
Push the button to confirm. Next setting appears.
Year Month Day Hour Minute
Operating instructions
HEM-7221-C1_C_M.book Page 11 Monday, November 22, 2010 1:19 PM
12
3. Using the Unit
3. Using the Unit
3.1 Applying the Arm Cuff
Remove tight-fitting clothing or tight rolled up sleeve from your upper arm.
Do not place the cuff over thick clothes.
1. Insert the air plug into the air jack.
2. Hold the grip on the cuff securely
with your hand.
3. Apply the cuff to your upper arm.
HEM-7221-C1_C_M.book Page 12 Monday, November 22, 2010 1:19 PM
13
3. Using the Unit
The bottom edge of the cuff should be 1 to 2 cm above the elbow.
Blue strip is centred on the middle of your inner arm. Close the fabric fastener FIRMLY.
Notes:
When you take a measurement on the right arm, air tube will be at the side of your elbow. Be careful not to rest your arm on the air tube.
The blood pressure can differ between the right arm and the left arm, and therefore also the measured blood pressure values can be different. OMRON recommends to always use the same arm for measurement. If the values between the two arms differ substantially, please check with your doctor which arm to use for your measurement.
1 to 2 cm
HEM-7221-C1_C_M.book Page 13 Monday, November 22, 2010 1:19 PM
14
3. Using the Unit
3.2 How to Sit Correctly
To take a measurement, you need to be relaxed and comfortably seated, under comfortable room temperature. No bathing, drinking alcohol or caffeine, smoking, exercising or eating 30 minutes before taking a measurement.
• Sit on a chair with your feet flat on the floor.
• Sit upright with your back straight.
• The cuff should be at the same level as your heart.
HEM-7221-C1_C_M.book Page 14 Monday, November 22, 2010 1:19 PM
15
3. Using the Unit
3.3 Taking a Reading
Notes:
• To cancel a measurement, press the START/STOP button to turn the unit off and to release the air in the arm cuff.
• Remain still while taking a measurement.
1. Press the START/STOP button.
The cuff will start to inflate automatically.
Dual Check System
Press the START/STOP button, then the Dual Check System lamp lights and the unit starts detecting a device error. If the unit is accurate and functioning correctly, the Dual Check System lamp remains lit during the measurement. If an error is detected, the Dual Check System lamp flashes and “Er” will appear on the display.
START
INFLATE DEFLATE
END
COMPLETE
Cuff Wrapping Guide
If your systolic pressure is more than 220 mmHg
After the cuff starts to inflate, press and hold the START/STOP button until the monitor inflates 30 to 40 mmHg higher than your expected systolic pressure.
Notes:
• The monitor will not inflate above 299 mmHg.
• Do not apply more pressure than necessary.
Dual Check System
HEM-7221-C1_C_M.book Page 15 Monday, November 22, 2010 1:19 PM
16
3. Using the Unit
Cuff Wrapping Guide
The Cuff Wrapping Guide is a unique feature that indicates if the cuff is not wrapped tightly enough around the arm. Even when the is displayed, a blood pressure reading will be taken.
2. Remove the arm cuff.
3. Press the START/STOP button to turn the monitor off.
The monitor automatically stores the measurement in its memory.
It will automatically turn off after 2 minutes.
Important:
Recent research suggests that the following values can be used as a guide to high blood pressure for measurements taken at home.
This criteria is for home blood pressure measurement.
Systolic Blood Pressure Above 135 mmHg
Diastolic Blood Pressure Above 85 mmHg
Note: This reading is NOT reliable due to the incorrect wrapping
of the cuff. Please wrap the cuff again, taking care to wrap it correctly and take the measurement again. When the is displayed, the cuff is correctly wrapped tightly enough on the arm and the reading is accurate and reliable.
HEM-7221-C1_C_M.book Page 16 Monday, November 22, 2010 1:19 PM
17
3. Using the Unit
Your blood pressure monitor includes an irregular
heartbeat feature. Irregular heartbeats can influence the results of the measurement. The irregular heartbeat algorithm automatically determines if the measurement is usable or needs to be repeated. If the measurement results are affected by irregular heartbeats but the result is valid, the result is shown together with the irreg
ular heartbeat symbol ( ). I
f the irregular heartbeats cause the measurement to be invalid, no result is shown. If the irregular heartbeat symbol ( ) is shown after you have taken a measurement, repeat the measurement. If the irregular heartbeat symbol ( ) is shown frequently, please make your doctor aware of it.
If you move during measurement, the movement error symbol ( ) will appear on the display. Keep still and repeat the measurement.
Note: Wait 2-3 minutes before taking another blood pressure
measurement. Waiting between readings allows the arteries to return to the condition prior to taking the blood pressure measurement.
Warning:
Self-diagnosis of measured results and treatment are dangerous.
Please follow the instructions of your doctor.
HEM-7221-C1_C_M.book Page 17 Monday, November 22, 2010 1:19 PM
Loading...
+ 39 hidden pages