Omron HEM-7211-E, HEM-7211-E8, HEM-CR24 User Manual

OMRON HEALTHCARE Co., Ltd.
24, Yamanouchi Yamanoshita-cho, Ukyo-ku, Kyoto 615-0084 JAPAN
Check following components!
Vérifier les composants suivants ! Prüfen Sie folgende Teile des Lieferumfangs! Controllare i componenti indicati di seguito! ¡Compruebe los siguientes componentes!
Controleer de volgende onderdelen!
Проверьте следующие компоненты!
EU-representative
Production facility Site de production
Produktionsstätte
Oficina de producción Productiefaciliteit Производственное подразделение
Stabilimento di produzione
Subsidiary Succursale Niederlassung
Empresa filial Dochteronderneming Дочерняя компания
Consociata
OMRON HEALTHCARE EUROPE B.V.
Kruisweg 577, 2132 NA Hoofddorp, THE NETHERLANDS www.omron-healthcare.com
OMRON (DALIAN) CO., LTD.
Economic & Technical Development Zone Dalian 116600, CHINA
OMRON HEALTHCARE UK LIMITED
Opal Drive, Fox Milne Milton Keynes, MK15 0DG U.K.
OMRON MEDIZINTECHNIK HANDELSGESELLSCHAFT mbH
John-Deere-Str. 81a 68163 Mannheim, GERMANY www.omron-medizintechnik.de
OMRON Santé France SAS
14, rue de Lisbonne 93561 Rosny-sous-Bois Cedex, FRANCE
Fabricado en ChinaMade in China
Geproduceerd in ChinaFabriqué en Chine
Сделано в КитаеHergestellt in China
Prodotto in Cina
Automatic Blood Pressure Monitor
Model M6
Instruction Manual
English
Français
Deutsch
Italiano
Español
Nederlands
IM-HEM-7211-E-03-10/2010
5329521-0B
Automatic
English
Français
Deutsch
Blood Pre
Italiano
ssure Mon
Model
itor
Españ
M6
Instru
ction Manual
ol
Nederlands
IM
-H EM
-72 1 1-E
-03­1 0/2010
5329521-0B
Contents
21
b
F
J
L
c
d
a
Thank you for purchasing the OMRON M6 Automatic Blood Pressure Monitor. The OMRON M6 is a compact, fully automatic blood pressure monitor, operating on the oscillometric principle. It measures your blood pressure and pulse rate simply and quickly. For comfortable controlled inflation without the need of pressure pre-setting or re-inflation the device uses its advanced “IntelliSense” technology.
Intended Use This product is designed to measure the blood pressure and pulse rate of people within the range of the designated arm cuff, following the instructions in this instruction manual. It is mainly designed for general household use. Please read the Important Safety Information in this instruction manual before using the unit.
Important Safety Information ........................ 1
1. Overview.................................................................3
2. Preparation.............................................................4
2.1 Installing/Replacing the Batteries...........4
2.2 Setting the Date and Time .....................5
3. Using the Unit ........................................................6
3.1 Applying the Arm Cuff ............................6
3.2 How to Sit Correctly ...............................7
3.3 Taking a Reading ...................................8
3.4 Using the Memory Function .................11
Please read this instruction manual thoroughly before using the unit. Please keep for future reference. For specific information about your own blood pressure, CONSULT YOUR DOCTOR.
4. Troubleshooting and Maintenance................13
4.1 The Icons and Error Messages ........... 13
4.2 Troubleshooting................................... 15
4.3 Maintenance ........................................ 17
4.4 Storage................................................ 18
5. Optional Parts...................................................... 19
6. Technical Data..................................................... 20
7. Some Useful Information about Blood Pressure ..23
F
E
I J K
B C
D
M
N
O
P
Q
R
L
A
GG
HH
S T
U V
W
X
Y Z
Important Safety Information
Consult your doctor prior to using in pregnancy or if diagnosed with arrhythmia or arteriosclerosis. Please read this section carefully before using the unit.
Warning:
• Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
(General Usage)
• Always consult your doctor. Self-diagnosis of measurement results and self-treatment are dangerous.
• People with severe blood flow problems, or blood disorders, should consult a doctor before using the unit, as cuff inflation can cause internal bleeding.
(AC Adapter Usage)
• Never plug in or unplug the power cord from the electric outlet with wet hands.
(Battery Usage)
• If battery fluid should get in your eyes, immediately rinse with plenty of clean water. Consult a doctor immediately.
Caution:
• Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury to the user or patient or damage to the equipment or other property.
(General Usage)
• Do not leave the unit unattended with infants or persons who cannot express their consent.
• Do not use the unit for any purpose other than measuring blood pressure.
• Use only the approved arm cuff for this unit. Use of other arm cuffs may result in incorrect measurement results.
• Make sure that the air tube is not wrapped around other parts of your body when taking measurements at night. This could result in injury when the air pressure in the air tube is increased.
• Do not leave the cuff wrapped on the arm if taking measurements during the night. This could result in injury.
• Do not use a mobile phone or other devices that emit electromagnetic fields, near the unit. This may result in incorrect operation of the unit.
• Do not operate the unit in a moving vehicle (car, airplane).
• To inflate the cuff manually, refer to Section 3.3. If the cuff is over inflated, it can cause internal bleeding.
EN
1
Important Safety Information
(AC Adapter Usage)
• Use only the original AC adapter (optional) designed for this unit. Use of unsupported adapters may damage and/or may be hazardous to the unit.
• Plug the AC adapter into the appropriate voltage outlet. Do not use a multiple-tap.
• Do not use the AC adapter if the unit or the power cord is damaged. Turn off the power and unplug the power cord immediately.
(Battery Usage)
• If battery fluid should get on your skin or clothing, immediately rinse with plenty of clean water.
• Use only four “AA” alkaline or manganese batteries with this unit. Do not use other types of batteries.
• Do not insert the batteries with their polarities incorrectly aligned.
• Replace old batteries with new ones immediately. Replace all four batteries at the same time.
• Remove the batteries if the unit will not be used for three months or more.
• Do not use new and used batteries together.
General Precautions
• Do not apply strong shocks and vibrations to or drop the unit and arm cuff.
• Do not take measurements after bathing, drinking alcohol or caffeine, smoking, exercising or eating.
• Do not forcibly bend the arm cuff or bend the air tube excessively.
• When removing the air tube, pull on the air plug at the connection with the main unit not the tube itself.
• Do not inflate the arm cuff when it is not wrapped around your arm.
• Read and follow the “Important information regarding Electro Magnetic Compatibility (EMC)” in the Technical Data Section.
• Read and follow the “Correct Disposal of This Product” in the Technical Data Section when disposing of the device and any used accessories or optional parts.
2
1. Overview
Open the rear cover page to read following:
The alphabet in the rear cover page correspond to those in the body page.
A
B
CDE
FGH
I
J
K
LMN
OPQRS
TUV
W
X
Y
Z
Main unit
Arm cuff
Display
Display Memory button O/I START ( ) button Up/Down ( ) buttons Date/Time setting ( ) button Air Jack Battery compartment AC adapter jack (for optional AC adapter)
Arm cuff (Medium cuff: arm circumference 22-32cm) Coloured Marker Air tube Air plug
Date/Time display Dual Check System Systolic blood pressure Diastolic blood pressure Heartbeat symbol
(Flashes during measurement)
Battery low symbol Average value symbol Memory symbol Irregular heartbeat symbol Movement error symbol Blood pressure level indicator Deflation symbol Cuff wrapping guide Pulse display and Memory number
EN
3
2. Preparation
4
2.1
Installing/Replacing the Batteries
1. Remove the battery cover.
2. Insert four “AA” batteries as
indicated in the battery compartment and then replace the battery cover.
Notes:
• If the battery low symbol ( ) appears on the display, turn the unit off then replace all batteries at the same time.
• The measurement values continue to be stored in memory even after the batteries are replaced.
Disposal of used batteries should be carried out in accordance with the national regulations for the disposal of batteries.
2. Preparation
1)
2)
Yea r
Month
Day
Hour
Minute
Push or buttons to change.
Push the button to confirm. Next setting appears.
2.2
Setting the Date and Time
1. Press the button.
2. Set the monitor to the correct date and time before
taking a measurement for the first time.
3. Press the O/I START button to store the setting.
Notes:
• If the batteries have been removed for 30 seconds or more, the date and time setting will need to be reset.
• If the date and time are not set, “-:--” appears during or after measurement.
EN
5
3. Using the Unit
Open both the front and rear covers to read following:
The alphabet and number in the cover page correspond to those in the body page.
L
F
a
J
b
3.1
Applying the Arm Cuff
Remove tight-fitting clothing or tight rolled up sleeve from your upper arm. Do not place the cuff over thick clothes.
1. Insert the air plug into the air jack.
2. Put your arm through the cuff loop.
3. Position the arm correctly.
The bottom edge of the cuff should be 1 to 2 cm above the elbow. Marker (arrow under tube) is centred on the middle of your inner arm. Close the fabric fastener FIRMLY.
Notes:
• When you take a measurement on the right arm, air tube will be at the side of your elbow. Be careful not to rest your arm on the air tube. ---
• The blood pressure can differ between the right arm and the left arm, and therefore also the measured blood pressure values can be different. Omron recommends to always use the same arm for measurement. If the values between the two arms differ substantially, please check with your physician which arm to use for your measurement.
6
3. Using the Unit
c
d
3.2
How to Sit Correctly
To take a measurement, you need to be relaxed and comfortably seated, under comfortable room temperature. No bathing, drinking alcohol or caffeine, smoking, exercising or eating 30 minutes before taking a measurement.
• Sit on a chair with your feet flat on the floor.
• Sit upright with your back straight. ---
• The cuff should be at the same level as your heart. ---
EN
7