Omron HEM-650, HEM-650CAN Instruction Manual

Wrist Blood Pressure Monitor
with Advanced Positioning Sensor (APS®)
Model HEM-650
Instruction Manual
ENGLISH
HEM-650_E_SP_q6.qxp 6/25/07 7:19 PM Page 1
6
5
0
2
Before Using the Monitor
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Operating the Device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Care and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Before Taking a Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Operating Instructions
Know Your Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Unit Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Display Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Irregular Heartbeat Symbol ( ) . . . . . . . . . . . . . . . . . . . . . . . . .10
Heartbeat Symbol ( ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Average Value Symbol ( ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Battery Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Setting the Advanced Positioning Sensor . . . . . . . . . . . . . . . . . . . . . . . . .15
Setting the Position Sensor Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Setting the Measurement Wrist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Setting the Date and Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Applying the Wrist Cuff . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Taking a Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
Taking a Measurement on the Left Wrist . . . . . . . . . . . . . . . . . . .24
Taking a Measurement on the Right Wrist . . . . . . . . . . . . . . . . . .26
Using the Memory Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
Averaging Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
To Display the Measurement Values . . . . . . . . . . . . . . . . . . . . . . .28
To Delete All Values Stored in the Memory . . . . . . . . . . . . . . . . .29
Care and Maintenance
Care and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
Error Indicators and Troubleshooting Tips . . . . . . . . . . . . . . . . . . . . . . . .31
FCC Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35
TABLE OF CONTENTS
HEM-650_E_SP_q6.qxp 6/25/07 7:19 PM Page 2
3
INTRODUCTION
Thank you for purchasing the Omron®HEM-650 Wrist Blood Pressure Monitor with Advanced Positioning Sensor (APS
®
).
The Omron wrist monitor uses the oscillometric method of blood pressure measurement. This means the monitor detects your blood’s movement through the artery in your wrist and converts the movements into a digital reading.
Clinical research has proven a direct relationship between blood pressure in the wrist and blood pressure in the arm. Changes in wrist blood pressure reflect changes in arm blood pressure because the arteries in the arm and wrist connect.
Frequently measuring the blood pressure in your wrist will provide your physician with an accurate indication of changes in your blood pressure.
The HEM-650 comes with the following components:
• Main Unit • 2 “AAA” Batteries • Storage Case
• Warranty Card
• Instruction Manual printed in English and Spanish
The Omron HEM-650 Wrist Blood Pressure Monitor is intended for home use.
Fill in for future reference.
DATE PURCHASED:______________________ SERIAL NUMBER:________________________
Staple your purchase receipt here
SAVE THESE INSTRUCTIONS
Before Using the Monitor
HEM-650_E_SP_q6.qxp 6/25/07 7:19 PM Page 3
4
OPERATING THE DEVICE
Contact your physician for specific information about your blood pressure. Self-diagnosis and treatment using measured results may be dangerous. Follow the instructions of your physician or licensed healthcare provider.
If battery fluid should get in your eyes, immediately rinse with plenty of clean water. Contact a physician immediately.
If you have a condition that may compromise circulation, you may get an inaccurate reading with this device. Consult your physician before using this device.
Read all of the information in the instruction manual and any other literature in the box before operating the unit.
This device is intended for use in measuring blood pressure and pulse rate in the adult population. Do not use this device on infants or persons who cannot express their intentions.
SAFETY INFORMATION
To assure the correct use of the product basic safety measures should always be followed including the warnings and cautions listed in this instruction manual.
WARNING
Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
SAFETY SYMBOLS USED IN THIS INSTRUCTION MANUAL
CAUTION
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury to the user or patient or damage to the equipment or other property.
HEM-650_E_SP_q6.qxp 6/25/07 7:19 PM Page 4
5
SAFETY INFORMATION
OPERATING THE DEVICE (continued)
Operate the device only as intended. Do not use the device for any other purpose.
Dispose of the device, components and optional accessories according to applicable local regulations. Unlawful disposal may cause environmental pollution.
Do not use a cellular phone near the device. It may result in an operational failure.
Use only Omron authorized parts and accessories. Parts and accessories not approved for use with the device may damage the unit.
Use only 1.5V alkaline batteries with this device. Do not use other types of batteries. This may damage the unit.
CARE AND MAINTENANCE
Do not subject the monitor to strong shocks, such as dropping the unit on the floor.
Do not submerge the device or any of the components in water.
Store the device and the components in a clean, safe location.
Changes or modification not approved by Omron Healthcare will void the user warranty. Do not disassemble or attempt to repair the unit or components.
HEM-650_E_SP_q6.qxp 6/25/07 7:19 PM Page 5
6
BEFORE TAKING A MEASUREMENT
To ensure a reliable reading follow these recommendations:
1. Avoid eating, drinking alcohol, smoking, exercising and bathing for at least 30 minutes before taking measurement. Rest for at least 15 minutes before taking a measurement.
2. Stress raises blood pressure. Avoid taking measurements during stressful times.
3. The cuff can be applied to your left or right wrist.
4. Measurements should be taken in a quiet place and you should be in a relaxed, seated position.
5. Remain still and do not talk during the measurements.
6. Keep a record of your blood pressure and pulse for your physician. A single measurement may not provide an accurate indication of your true blood pressure. You need to take and record several readings over a period of time. Try to measure your blood pressure at the same time each day for consistency.
7. Wait 2-3 minutes between measurements. The wait time allows the arteries to return to the condition prior to taking the blood pressure measurement. You may need to increase the wait time depending on your individual physiological characteristics.
HEM-650_E_SP_q6.qxp 6/25/07 7:19 PM Page 6
7
KNOW YOUR UNIT
650
Battery Compartment
Display
Wrist Cuff
Main Unit:
SET Button
MEM (Memory) Button
START/STOP Button
Operating Instructions
Inner Surface of Wrist Cuff
Fabric Fastener (hook)
Fabric Fastener (loop)
HEM-650_E_SP_q6.qxp 6/25/07 7:19 PM Page 7
8
INTELLISENSE®TECHNOLOGY IS AN ASSURANCE OF ACCURACY
Blood pressure changes throughout the day. IntelliSense
®
Technology automatically determines the optimum amount of pressure required to quickly and comfortably measure your blood pressure. This helps to ensure an accurate measurement.
ADVANCED POSITIONING SENSOR (APS
®
) ENSURES A RELIABLE
MEASUREMENT
Correct cuff positioning is critical when monitoring blood pressure. The Omron Wrist Blood Pressure Monitor with APS
®
has a unique positioning sensor that confirms the cuff is level with the user’s heart. This helps ensure that each reading is accurate and reliable.
KNOW YOUR UNIT
Components:
Two “AAA” Batteries
Storage Case
Instruction Manual
Wrist Blood Pressure Monitor
with Advanced Positioning Sensor (APS®)
Model HEM-650
6 5 0
HEM-650_E_SP_q6.qxp 6/25/07 7:19 PM Page 8
9
UNIT DISPLAY
Diastolic Blood Pressure
Systolic Blood Pressure
Pulse Display
Low Battery Indicator Cuff Deflation Symbol
Right Wrist Measurement Symbol
Position Sensor Alarm Symbol
Heartbeat Symbol
Memory Value Symbol
Average Value Symbol
Irregular Heartbeat Symbol
Date/Time Display
HEM-650_E_SP_q6.qxp 6/25/07 7:19 PM Page 9
10
IRREGULAR HEARTBEAT SYMBOL ( )
When the monitor detects an irregular rhythm two or more times during the measurement, the Irregular Heartbeat Symbol ( ) will appear on the display with the measurement values.
An irregular heartbeat rhythm is defined as a rhythm that is more than 25% slower or 25% faster from the average rhythm detected while the monitor is measuring the systolic blood pressure and the diastolic blood pressure.
If the irregular heartbeat symbol ( ) displays with your measurement results, we recommend you consult your physician. Follow the directions of your doctor.
Normal Heartbeat
Normal Heartbeat
Irregular Heartbeat
Pulse
Blood
pressure
Pulse
Blood
pressure
Short Long
DISPLAY SYMBOLS
HEM-650_E_SP_q6.qxp 6/25/07 7:19 PM Page 10
11
DISPLAY SYMBOLS
The American Heart Association (AHA) recommends the following guideline for upper limit of normal for home blood pressure readings:
AHA Home Guideline for Upper Limit of Normal BP
Systolic Blood Pressure 135 mmHg
Diastolic Blood Pressure 85 mmHg
This is a general guideline because blood pressure depends on age and morbidity. The AHA recommends a lower home blood pressure goal for certain patients, including diabetic patients, pregnant women, and patients with renal failure
1
.
The monitor is not intended to be a diagnostic device.
WARNING
Contact your physician for specific information about your blood pressure. Self-diagnosis and treatment using measured results may be dangerous. Follow the instructions of your physician or licensed healthcare provider.
Omron Healthcare recommends you contact your physician if the HEARTBEAT SYMBOL ( ) appears on the display with your measurement values. Follow the directions of your doctor.
1
American Heart Association Scientific Statement 2004
HEM-650_E_SP_q6.qxp 6/25/07 7:19 PM Page 11
12
DISPLAY SYMBOLS
HEARTBEAT SYMBOL ( )
TAKING A MEASUREMENT
The Heartbeat Symbol ( ) flashes on the display during the measurement. The Heartbeat Symbol ( ) flashes at every heartbeat.
When the measurement is complete, the Heartbeat Symbol ( ) flashes on the display with your blood pressure and pulse rate if the reading is above 135 for the Systolic Blood Pressure value and/or 85 for the Diastolic Blood Pressure value.
USING THE MEMORY FUNCTION
The Heartbeat Symbol ( ) flashes when the blood pressure reading stored in the memory is above 135 for the Systolic Blood Pressure value and/or 85 for the Diastolic Blood Pressure value.
AVERAGE VALUE SYMBOL ( )
The Average Value Symbol ( ) is displayed when you press the MEM button. The most recent average reading appears on the display screen.
HEM-650_E_SP_q6.qxp 6/25/07 7:19 PM Page 12
13
BATTERY INSTALLATION
1. Press both sides of the battery cover and lift the cover off in the direction of the arrow.
2. Install 2 “AAA” Alkaline Batteries so the + (positive) and - (negative) polarities match the polarities of the battery compartment as indicated.
3. Replace the Battery Cover. Make sure the cover clicks securely over the battery compartment.
HEM-650_E_SP_q6.qxp 6/25/07 7:19 PM Page 13
MEM
START
STOP
SET
MEM
START
STOP
SET
M
E
M
START
STOP
SET
14
BATTERY INSTALLATION
BATTERY REPLACEMENT
When the Low Battery Indicator appears on the display screen turn the monitor off and remove all the batteries. Replace with two new batteries at the same time.
WARNING
If battery fluid should get in your eyes, immediately rinse with plenty of clean water. Contact a physician immediately.
NOTES: • Turn the unit off before replacing the batteries. Measurement
values stored in the memory are not deleted during battery replacement.
• When the batteries are replaced, you may need to reset the date and time. If the year is flashing on the display screen, refer to “Setting the Date and Time”.
• The supplied batteries may have a shorter life.
CAUTION
Dispose of the device, components and optional accessories according to applicable local regulations. Unlawful disposal may cause environmental pollution.
Low Battery Indicator
HEM-650_E_SP_q6.qxp 6/25/07 7:19 PM Page 14
1515
SETTING THE ADVANCED POSITIONING SENSOR
The Advanced Positioning Sensor (APS®) will assure you the unit is in the correct position level with the user’s heart before the monitor starts to take the measurement. When the APS is set to ON, the Heartbeat Symbol ( ) flashes once your wrist is in the correct position. The APS is set to ON at the time of purchase.
1. TO CHANGE THE SETTING
Press the START/STOP button to turn the power off, then press the SET button.
The Position Sensor symbol ( ) will appear on the display.
2. SELECTING ON OR OFF
Press the MEM button to change the setting to OFF.
Press the MEM button again to change the setting to ON.
3. CONFIRM THE SETTING
Press the START/STOP button to confirm the APS function you selected and to turn the monitor off.
HEM-650_E_SP_q6.qxp 6/25/07 7:19 PM Page 15
1616
SETTING THE POSITION SENSOR ALARM
The Position Sensor Alarm emits sound to help you place your wrist in the correct position. The Position Sensor Alarm can be set to ON or OFF when the APS is set to ON. The Position Sensor Alarm is set to ON1 at the time of purchase.
The alarm set to “ON1” emits a series of blips when your wrist is too far away from the correct measuring position and beeps slowly once your wrist is in the correct position.
The alarm set to “ON2” beeps only once your wrist is in the correct position.
1. TO CHANGE THE SETTING
Press the START/STOP button to turn the power off, then press the SET button twice.
The Position Sensor Alarm symbol ( ) will appear on the display.
2. SELECTING ON1, ON2, OR OFF
Press the MEM button to change the setting to “ON2”, “OFF” and “ON1”.
3. CONFIRM THE SETTING
Press the START/STOP button to confirm the alarm function you selected and to turn the monitor off.
HEM-650_E_SP_q6.qxp 6/25/07 7:19 PM Page 16
17
SETTING THE MEASUREMENT WRIST
The monitor is designed to take measurements on the left wrist or the right wrist. The monitor is set to OFF to take measurements on the left wrist at the time of purchase.
1. TO CHANGE THE SETTING
Press the START/STOP button to turn the power off, then press the SET button three (3) times.
The Right Wrist Measurement symbol ( ) will appear on the display.
2. SELECTING ON OR OFF
Press the MEM button to change the wrist setting to ON to take measurements on the right wrist.
Press the MEM button again to change the wrist setting to OFF to take measurements on the left wrist.
3. CONFIRM THE SETTING
Press the START/STOP button to confirm the measurement wrist you selected and to turn the monitor off.
HEM-650_E_SP_q6.qxp 6/25/07 7:19 PM Page 17
18
SETTING THE DATE AND TIME
Set the monitor to the current date and time before taking a measurement for the first time. If the date and time are not set correctly, the measurement values stored in the memory will have the wrong date and time.
Set the date and time in the following situations:
1. Before you use the monitor for the first time
2. After battery replacement
1. TO CHANGE THE SETTING
Press the START/STOP button to turn the power off, then press the SET button four (4) times.
The year flashes on the display with the current setting.
2. SETTING THE YEAR
The year can be set between 2004 and 2030.
When the display reaches 2030, it will return to 2004.
Press the MEM button to advance by increments of one year.
NOTE: Press and hold the MEM button to
increase the values faster.
HEM-650_E_SP_q6.qxp 6/25/07 7:19 PM Page 18
19
SETTING THE DATE AND TIME
Press the SET button to confirm the setting.
The month flashes on the display.
3. SETTING THE MONTH
Press the MEM button to advance by increments of one month.
Press the SET button to confirm the setting.
The day flashes on the display.
4. SETTING THE DAY
Press the MEM button to advance by increments of one day.
Press the SET button to confirm the setting.
The hour flashes on the display.
5. SETTING THE HOUR
The time is set using AM or PM.
Press the MEM button to advance by increments of one hour.
Press the SET button to confirm the setting.
The minute flashes on the display.
HEM-650_E_SP_q6.qxp 6/25/07 7:19 PM Page 19
20
SETTING THE DATE AND TIME
6. SETTING THE MINUTE
Press the MEM button to advance by increments of one minute.
Press the SET button to confirm the setting.
The APS setting screen is displayed.
Press the START/STOP button to turn the monitor off.
HEM-650_E_SP_q6.qxp 6/25/07 7:19 PM Page 20
21
APPLYING THE WRIST CUFF
The monitor is designed to take measurements on the left wrist or the right wrist. The monitor is set to take measurements on the left wrist at the time of purchase. To change the setting, refer to “Setting the Measurement Wrist”.
CAUTION
Read all of the information in the instruction manual and any other literature in the box before operating the unit.
CAUTION
This device is intended for use in measuring blood pressure and pulse rate in the adult population. Do not use this device on infants or persons who cannot express their intentions.
HEM-650_E_SP_q6.qxp 6/25/07 7:19 PM Page 21
22
APPLYING THE WRIST CUFF ON THE LEFT WRIST
1. Roll up sleeve. Make sure your sleeve is not rolled up too tight on your arm. This may constrict the flow of blood in your arm.
2. Wrap the cuff directly against your skin. Do not apply over clothing. Place the cuff over your left wrist with your left thumb facing upward.
3. Position the cuff leaving a clearance of approximately 1/2 to 1 inch between the cuff and the bottom of your palm.
4. Hold the bottom part of the cuff and wrap it around the wrist so it fits comfortably and securely around your wrist.
5. Fold the remaining part of the wrist cuff back out of the way. Lightly press the cloth closure with your finger so the cuff is securely fastened.
APPLYING THE WRIST CUFF
HEM-650_E_SP_q6.qxp 6/25/07 7:19 PM Page 22
M E M
S T A R
T S T O
P
S E T
M EM
S
T A
R
T
S
T O
P
S E T
Loading...
+ 50 hidden pages