Thank you for purchasing the OMRON®HEM-650 Automatic
Wrist Blood Pressure Monitor with A.P.S.
®
.
Fill-in for future reference
DATE PURCHASED: ________________
SERIAL NUMBER: __________________
Staple your purchase receipt here.
The monitor is compact and easy-to-use at home, at work, and
during travel. Perfect for people who frequently monitor their
own blood pressure.
OMRON
®
digital blood pressure monitors use the oscillometric method
of blood pressure measurement. This means the monitor detects your
blood’s movement through your artery and converts the movements
into a digital reading. An oscillometric monitor does not need a
stethoscope so the monitor is simple to use.
Clinical research has proven a direct relationship between blood
pressure in the wrist and blood pressure in the arm. Changes in
wrist blood pressure reflect changes in arm blood pressure
because the arteries in the wrist and the arm are close to each
other. Frequently measuring the blood pressure in your wrist
will provide your physician with an accurate indication of
changes in your blood pressure.
®
The OMRON
with A.P.S.
HEM-650 Automatic Wrist Blood Pressure Monitor
®
is intended for home use.
SAVE THESE INSTRUCTIONS
3
IMPORTANT SAFETY NOTES
To assure the correct use of the product basic safety measures
should always be followed including the precautions listed below:
þ Consult your physician before measuring blood pressure at
the wrist if you have any of the following conditions:
severe hypertension, severe diabetes, severe arteriosclerosis,
severe kidney disease, or vascular disease that may
compromise circulation.
þ Read all information in the instruction book and any other
literature included in the box before using the unit.
þ Contact your physician for specific information about your blood
pressure. Follow the instructions of your healthcare provider.
þ Operate the unit only as intended. Do not use for
any other purpose.
þ The unit is intended for use in measuring blood pressure and
pulse rate in adult patient population. Do not use on infants.
þ Do not use a cellular phone near the unit. It may result in
operational failure.
þ Changes or modifications not approved by Omron Healthcare
will void the user warranty. Do not disassemble or attempt to
repair the unit or components.
4
BEFORE TAKING A MEASUREMENT
1. Avoid eating, drinking alcohol, smoking, exercising and bathing
for 30 minutes before taking a measurement. Rest for at least 15
minutes before taking the measurement.
3. The cuff can be applied to your left or right wrist. Always
measure your blood pressure on the same wrist.
4. Measurements should be taken in a quiet place.
5. Position the unit at heart level throughout the measurement.
6. Remain still and do not talk during the measurement.
7. Keep a record of your blood pressure and pulse readings for your
physician. A single measurement does not provide an accurate
indication of your true blood pressure. You need to take and
record several readings over a period of time. Try to measure
your blood pressure at the same time each day for consistency.
8. Wait 2-3 minutes between measurements. The wait time allows
the arteries to return to the condition prior to taking the blood
pressure measurement. You may need to increase the wait time
depending on your individual physiological characteristics.
5
Main Unit
Display
Battery Compartment
Accessories
KNOW YOUR UNIT
Wrist Cuff
MEM Button
START/STOP Button
SET Button
Two “AAA” Alkaline Batteries
Storage Case
6
UNIT DISPLAY
Heart Symbol
Systolic Blood Pressure
Diastolic Blood Pressure
Battery Low Symbol
Cuff Deflation Symbol
Right Wrist
Measurement Symbol
Position Sensor Alarm Symbol
Pulse Display
IRREGULAR HEARTBEAT SYMBOL ()
When the monitor detects an irregular rhythm two or more times
during the measurement, the Irregular Heartbeat Symbol
will appear on the display with the measurement values.
Memory Value Symbol
Average Value Symbol
Irregular Heartbeat
Symbol
Date/Time Display
An irregular heartbeat rhythm is
defined as a rhythm that varies by
less than 25% from the average
rhythm or 25% more than the
average rhythm detected while the
monitor is measuring the systolic
and diastolic blood pressure.
Pulse
Blood
pressure
Pulse
Blood
pressure
Normal Heartbeat
Irregular Heartbeat
Short Long
If the Irregular Heartbeat Symbol ( ) displays with your
measurement results we recommend you consult your physician.
Follow the directions of your doctor.
7
BATTERY INSTALLATION
M
E
M
SET
S
T
A
R
T
S
T
O
P
MEM
SET
START
STOP
MEM
SET
START
STOP
1. Press both sides of the battery cover and
lift the cover off in the direction of the arrow.
2. Install two “AAA” Alkaline Batteries in the
battery compartment, so that + (positive)
and - (negative) polarities match the polarities
of the battery compartment as indicated.
3. Replace the battery cover. Make sure the
battery cover is securely in place.
BATTERY REPLACEMENT
Initial Set-Up
When the Low Battery Symbol appears on the display screen
remove all the batteries. Replace with two new batteries at the same
time. When the Low Battery Symbol blinks a brief period of usage
remains. Long life alkaline batteries are recommended.
NOTES:
• Measurement values stored in the memory will not be deleted
during battery replacement.
• After replacing the batteries, reset the date and time. Refer to page
11, Setting the Date and Time.
• Dispose of batteries according to applicable local regulations.
Low Battery Symbol
8
ADVANCED POSITIONING SENSOR
The Advanced Positioning Sensor, A.P.S.®will assure you that the
unit is in the correct position before it starts to take a measurement.
1. Press the SET button
while the power is turned
off. The Position Sensor
symbol ( ) will
appear on the display.
2. Press the MEM button to select “on” or “oFF”. Press the
START/STOP button to save this selection. When the feature
is “on” the symbols will appear on the display. The heart symbol
will begin to flash when your wrist is in the correct position.
POSITION SENSOR ALARM
The Sensor Alarm emits sound to help you place your wrist in the
correct position.
1. Press the SET button twice
while the power is turned off.
The Position Sensor Alarm
symbol ( ) will appears on
the display.
The alarm set “on 1” emits a series of blips if your wrist is too
far away from the correct measuring position and beeps slowly
once your wrist is in the correct position. When “on 2” is set the
alarm only beeps once your wrist is in the correct position.
2. Press the MEM button to select “on 1”, “on 2” or “oFF”.
Press the START/STOP button to save this selection.
9
WRIST MEASUREMENT SELECTION
Blood Pressure Measurements can be taken on the left or right wrist.
1. Press the SET button three (3)
times while the power is turned
off. The Right Wrist Measurement
symbol ( ) will appear on
the display.
Select “on” to measure your blood pressure using your
right wrist.
Select “oFF” to measure your blood pressure using your
left wrist.
2. Press the MEM button to select “on” or “oFF”.
Press the START/STOP button to save this selection.
10
SETTING THE DATE AND TIME
The Blood Pressure Monitor stores up to 90 measurement values
with the date and time. The monitor also calculates an average
reading based on the last three measurement values.
Set the monitor to the current date and time before taking a
measurement for the first time. If the current date and time is not
set, the default date and time will display. The measurement values
will be stored in the memory with the wrong date and time.
1.
TO START THE SETTING
Press the SET button four (4) times while
the power is turned off.
The will year flash on the display.
2.
SETTING THE YEAR
The year can be set between 2004 and 2030.
When the display reaches 2030, it will return
to 2004.
Press the MEM button to advance by increments
of one year.
NOTE: Press and hold the MEM button to increase
the values faster.
Press the SET button to set the current year.
The month flashes on the display.
11
SETTING THE DATE AND TIME
3. SETTING THE MONTH
Press the MEM button to advance by increments of one month.
Press the SET button to set the current month.
The day flashes on the display.
SETTING THE DAY
4.
Press the MEM button to advance by increments of one day.
Press the SET button to set the current day.
The hour flashes on the display.
5.
SETTING THE HOUR
The time is set using AM or PM.
Press the MEM button to advance by increments
of one hour.
Press the SET button to set the current hour.
The minutes flash on the display.
SETTING THE MINUTE
6.
Press the MEM button to advance by increments of one minute.
Press the SET button to set the current minute.
The year flashes on the display.
7. Press the START/STOP button to save this selection.
12
APPLYING THE WRIST CUFF
M
E
M
S
E
T
S
T
A
RT
S
T
OP
ME
M
S
E
T
S
T
A
RT
S
T
OP
M
E
M
S
E
T
S
T
A
R
T
S
T
O
P
MEM
S
ET
S
TAR
TST
O
P
Wrapping the wrist cuff is one of the most important points for
taking a correct measurement.
APPLYING THE CUFF ON THE LEFT WRIST
1. Roll up sleeve. Make sure your sleeve is not
rolled up too tightly on your arm. This may
constrict the flow of blood in your arm.
2. Wrap the cuff directly against your skin.
Do not apply over clothing. Place the cuff over
your left wrist with your left thumb facing upward.
3. Position the cuff leaving a clearance of approximately
1/2 to 1 inch between the cuff and the bottom of your palm.
4. Hold the bottom part of the cuff and wrap it
around the wrist so it fits comfortably and
securely around your wrist.
NOTE: Make sure the wrist cuff does not
cover the protruding part of the wrist bone
on the outside of the wrist.
5. Fold the remaining part of the wrist cuff back
out of the way.
APPLYING THE CUFF ON THE RIGHT WRIST
When taking a measurement using the right
wrist position the cuff as shown in the
illustration.
Make sure the right wrist measurement symbol
is displayed. Refer to page 10, Wrist
Measurement Selection to select “on”.
13
TAKING A MEASUREMENT
1. Sit comfortably in a chair with your feet
flat on the floor.
2. Press the START/STOP button.
3. Hold your arm across your chest at heart level.
Hold your elbow firmly to avoid body movement.
Sit still and do not talk or move during
the measurement.
4. Description of position sensor activity during measurement.
Blip Blip
Blip Blip
Blip Blip
Adjust the height of your wrist until the position sensor alarm beeps
slowly. When the monitor senses that your arm is in the correct
position, the wrist cuff will automatically start to inflate and
measurement starts.
NOTE: If your wrist is too low or too high, the position sensor
alarm will emit a series of two short bleeps similar to
a heartbeat.
The current time is displayed and the Heart Symbol starts to flash
while the cuff is inflating.
Hold the monitor at heart level until the measurement is completed.
NOTE: To stop the inflation or measurement, push the
START/STOP button. The monitor will stop inflating, start
deflating, and will turn off.
14
TAKING A MEASUREMENT
5. After the monitor has detected your blood pressure and pulse
rate, the cuff automatically deflates. Your blood pressure and
pulse rate are displayed.
Alternating Display
NOTE: The time and date of the measurement are
displayed alternately.
Press the START/STOP button
6.
to turn the monitor off.
NOTE: The monitor will automatically turn off after two minutes.
IRREGULAR HEARTBEAT FEATURE
The irregular heartbeat feature automatically determines if the
measurement is usable.
If the measurement results are affected by irregular heartbeats but
the result is valid, the result is shown together with the Irregular
Heartbeat Symbol ( ).
If the irregular heartbeats cause the measurement to be invalid, no
result is shown. If the Irregular Heartbeat Symbol ( ) is shown
after you have taken a measurement, repeat the measurement.
If the Irregular Heartbeat Symbol ( ) is shown frequently, please
notify your doctor.