Omron HEM-640-E User Manual

Blood Pressure Monitor
RX-3
Instruction manual page 1 Gebrauchsanweisung Seite 17 Gebruiksaanwijzing pagina 33
Mode d’emploi page 49 Manuale de instructone pagina 65 Manual de instrucciones pagina 81
IM-HEM-640-E-01-08/08
1628088-1E
RX-3 English
Introduction
The OMRON RX-3 measures your blood pressure and pulse simply and quickly from the wrist, without the use of an inflation bulb or stethoscope.The measurement values are stored in the memory of the OMRON RX-3. The OMRON RX-3 fits wrist circumferences from 13.5 to 19.5 cm.
How to obtain meaningful blood pressure readings
RX-3 English
General
• The OMRON RX-3 is not suitable for measuring the frequency of cardiac pacemakers.
• Consult your doctor during pregnancy, arrhythmia and arteriosclerosis.
• Avoid eating, drinking (alcohol), smoking, sport and taking a bath before measurement.
• Be calm and relaxed before and during measurement.
• You should never change the dose of medicines prescribed by your doctor.
Tips for use
• Check your blood pressure at least twice a day (before breakfast, after work).
• Do not measure your blood pressure while you are in a vehicle.
• Always measure on the same wrist.
• Wrap the wrist cuff around your wrist before start of measurement.
Caution
• Operating temperature between 10°C and 40°C.
• Operating environment must be free from excessive vibrations, shocks, magnetic fields, electrical noise, etc.
• Stay out of sunlight during measuring.
• Keep portable phones 5 meters away during measurement.
• Do not wrap the cuff other than around your wrist.
• Do not drop the OMRON RX-3.
Overview
A
D
E
C
B
RX-3 English
A Display B Wrist Cuff C Memory Recall button
D On/Off button E Battery Compartment
RX-3 English
Preparation
Insert batteries
1 Open the battery compartment. 2 Insert two batter ies in the batter y compar tment.
Caution! Use two identical 1.5V alkaline
batteries type AAA LR03!
3 Close the battery compartment.
Fit wrist cuff
M
Caution! Do not press On/Off button when the wrist cuff is not wrapped around the wrist!
RX-3 English
1 Bare your wrist.
Caution! Push up your sleeve: avoid constricting
the blood flow!
3 Hold the end of the wrist cuff and wrap it around
your wrist. Caution! Be sure the wrist cuff fits closely; do not pinch your arm!
2 Put the monitor on the inner side of your wrist.
Note: attach the monitor upside down for reliable
measurement at your right wrist.
Operation
SYSmmHg MEMORY
PULSE
/min
DIA mmHg
C D
F
H
G
P
J
N
M
L
K
RX-3 English
Control functions C Memory Recall button D On/Off button
Measurement F Systolic blood pressure in mmHg. G Monitor blood pressure: flash - measurement
takes place, light up - finish measurement.
H Diastolic blood pressure in mmHg. J Memory display: values in memory. K Memory position: 1 to 28. L Inflation:wrist cuff inflates and measurement starts. M Deflation: wr ist cuff deflates and measurement
finishes.
N Battery exhausted: batteries are weak/exhausted. P Pulse: heartbeats per minute.
Caution! Allow an interval of at least three minutes between two successive measurements!
SYSmmHg MEMORY
PULSE
/min
DIAmmHg
SYSmmHg MEMORY
PULSE
/min
DIA mmHg
RX-3 English
1 Sit comfortably at a table with your feet flat on the
floor and put your arm against the hard case.
2 Press On/Off button to start measurement.
The OMRON RX-3 measures during inflation!
Caution! The OMRON RX-3 should always be at heart height during measurement. Usage of the hard case assures the right position of the OMRON RX-3!
Caution! Sit still, do not move, do not speak and do not touch the OMRON RX-3!
Read display
SYSmmHg MEMORY
PULSE
/min
DIA mmHg
SYSmmHg MEMORY
PULSE
/min
DIA mmHg
SYSmmHg MEMORY
PULSE
/min
DIA mmHg
1 Read the values of blood pressure and pulse from the display. Note: Display shows alternately blood pressures and heartbeats.
2 Note values in your personal blood pressure pass. 3 Press On/Off button to turn off power.
RX-3 English
RX-3 English
SYSmmHg MEMORY
PULSE
/min
DIA mmHg
SYSmmHg MEMORY
PULSE
/min
DIA mmHg
K
SYSmmHg MEMORY
PULSE
/min
DIA mmHg
K
SYSmmHg MEMORY
PULSE
/min
DIA mmHg
Memory
Recall previous values K Memory position of latest and previous values.
1 Press Memory Recall button to turn on power.Note: Display shows alternately blood pressures and heartbeats.
2 Press Memory Recall button for latest and previous values. Press On/Off button to turn off power.
Note: Display shows alternately blood pressures and heartbeats.
RX-3 English
SYSmmHg MEMORY
PULSE
/min
DIA mmHg
SYSmmHg MEMORY
PULSE
/min
DIA mmHg
Erase memory
1 Press Memory Recall button to turn on power. 2 Press Memory Recall button and simultaneously
On/Off button to erase memory. Caution! All stored values will be erased! Press On/Off button to turn off power.
10
RX-3 English
Storage
• Store the OMRON RX-3 in the hard case in a dry, closed place with a temperature between -20°C and 60°C.
• Remove the batteries if you not intend to use the OMRON RX-3 for 3 months or more.
Faults: causes and rectifications
Fault Cause Rectification
Correct reading not possible Movement, sound vibration, Wait for at least three minutes to
weak pulse repeat measurement
Display Low voltage Batteries weak/exhausted Fit two new identical 1.5V alkaline empty batteries type AAA LR03
Inexplicable values Wrong working method Follow instructions, repeat
measurement
11
RX-3 English
Maintenance and spare parts
• Use a soft, slightly moistened cloth to clean the OMRON RX-3. Caution! Do not use petrol, thinners or similar solvents!
• Use a soft, moistened cloth and soap to clean the wrist cuff.
Caution! Do not wash the wrist cuff! Caution! Do not use petrol, thinners or similar
solvents!
• Do not carry out repairs of any kind yourself.If a defect occurs consult your OMRON retail outlet or distributor as mentioned on the packaging.
Calibration
• It is recommended to have the OMRON RX-3 inspected every two years to ensure correct function and accuracy. Consult your OMRON retail outlet or OMRON distributor as mentioned on the packaging.
12
Replace batteries
• Remove the battery out of the battery compartment and insert two new identical 1.5V alkaline batteries type AAA LR03 batteries.
Spare parts
• Due to high company quality standards, OMRON considers the main unit as a non-serviceable part because the need for proper calibration after replacement of high tech components.
• If the cuff needs to be replaced have this done by an authorised expert. Consult your OMRON retailer or OMRON distributor as mentioned on the packaging.
Attention! Disposal of batteries and the OMRON RX-3 should be carried out in accordance with the national regulations for the disposal of electronic products.
RX-3 English
Technical Data
Product name OMRON RX-3 wrist blood pressure monitor Model HEM-640-E Display Digital LCD Measuring range Blood pressure:0 - 299 mmHg / Pulse: 40 - 180 beats/minute Accuracy Blood pressure: ± 3 mmHg / Pulse: ± 5% of display reading Inflation Automatic by electric pump Deflation Automatic rapid deflation system Pressure detection Pressure sensor (capacitive) Measuring method Oscilliometric Memory 28 Measurements Power supply 2 x 1.5V Alkaline batteries (LR03) AAA Battery life New batteries will last for approx.300 measurements Operating temperature /humidity +10°C to +40°C / 30% to max. 85% relative humidity Operating environment Free from excessive vibrations, shocks, magnetic fields, electrical noise, etc. Storage temperature / humidity -20°C to +60°C /10% to max. 95% relative humidity Weight Approx. 140/160 g ex-/including batteries Outer dimensions Approx. 47 mm (W) x 71 mm (H) x 79 mm (D) Wrist circumference Approx. 13.5 cm to 19.5 cm Accessories Instruction manual, guarantee card, blood pressure pass,
Note Subject to technical modification without prior notice
= Type B 0197
Manufacturer OMRON HEALTHCARE CO., LTD.Japan EU-representative OMRON HEALTHCARE EUROPE B.V., Kruisweg 577, NL-2132 NA Hoofddorp
This device fulfils the provisions of the EC directive 93/42/EEC (Medical Device Directive).This blood pressure monitor is designed according to the European standard EN1060, Non-invasive sphygmomanometers Part 1: General Requirements and Part 3: Supplementary requirements for electromechanical blood pressure measuring systems. This OMRON product is produced under the strict quality system of OMRON HEALTHCARE CO., LTD., Japan.The Core component for OMRON blood pressure monitors, which is the Pressure Sensor, is produced in Japan.
2 alkaline batteries, storage box
Made in China
13
General information about blood pressure
Optimal blood
pressure
(target value)
Normal blood
pressure
Normal systolic value
Mild hypertension
Moderate hypertension
Severe hypertension
Systolic blood pressure (mmHg)
Diastolic blood pressure (mmHg)
80
180
160
140
130
120
85 90 100 110
Blood circulation
The blood circulation is responsible for supplying the body with oxygen. Blood pressure is the pressure exerted on the arteries.
The systolic blood pressure value (higher pressure or top value) represents the blood pressure produced by contraction of the heart muscle.
RX-3 English
The diastolic blood pressure value (lower pressure or lower value) represents the blood pressure produced by relaxation of the heart muscle.
Classification of blood pressure
The World Health Organisation (WHO) and the International Society of Hypertension (ISH)
14
developed the blood pressure classification.This classification is based on the blood pressure values measured while sitting on a chair in the outpatient department of a hospital. According to the blood pressure classification by the WHO/ISH.
RX-3 English
Health and blood pressure
The incidence of hypertension increases with age. In addition, a lack of exercise, excess body fat and high levels of cholesterol (LDL), which sticks to the inside in blood vessels, reduces elasticity of these vessels. Hypertension accelerates arter ial sclerosis which can lead to very serious conditions such as stroke and myocardial infarction.For these reasons it is very important to know whether the blood pressure is within a healthy range. Blood pressure fluctuates from minute to minute, throughout the day.Therefore it is essential to take regular measurements to help you identify an average blood pressure.
Symptoms of high blood pressure
High blood pressure can go unnoticed for a long time, since it does not cause noticeable symptoms. The following are all possible causes of abnormally high blood pressure:
• Overweight
• High cholesterol level
• Smoking
• Excessive alcohol consumption
• Stress and emotional upset
• Excessive consumption of salt
• Lack of physical exercise
• Genetic/hereditary predisposition
• Underlying illnesses, such as kidney disorders or endocrine disturbance
Blood pressure measurement
Measuring your blood pressure daily enables you to recognize high blood pressure at an early stage and obtain medical treatment.
The oscillometric method of measurement determines your blood pressure by measuring the pressure fluctuations caused by the pulse waves.
Since your blood pressure fluctuates within a day (see graphic next page), you should alw ays measure it at the same time each day to ensure that the measurements are genuinely comparable.At the doctor’s surgery, nervousness and tension may cause your blood pressure to be higher than in familiar circumstances at home.This is known as “White Coat Hypertension”.
15
mmHg
200
150
100
50
6 12 18 24
Upper curve: systolic blood pressure Lower curve: diastolic blood pressure
Time of day
16
RX-3 English
Treatment of high blood pressure
If your blood pressure reaches upper values of 140 ­160 mmHg and lower values of 90 - 95 mmHg in repeated measurements over several days, you should consult your doctor for detailed medical examination.You can assist the treatment prescribed by your doctor in the following ways:
• Loose weight and lower your cholesterol level by reducing the calories and fat in your diet.Cut down on animal fats and eat more fruit and vegetables .
• Reduce the consumption of alcohol.
• Reduce the intake of salt: the German League for Combating High Blood Pressure recommends six grams of salt per day (i.e.one teaspoon) on average.
• Stop smoking.
• Take regular exercise.
• Monitor your blood pressure.Example: fluctuation within a day (male, 35 years old)
EC REP
Manufacturer
EU-representative
Production facility
Subsidiary
OMRON HEALTHCARE CO., LTD.
24, Yamanouchi Yamanoshita-cho, Ukyo-ku Kyoto, 615-0084 Japan
OMRON HEALTHCARE EUROPE B.V.
Kruisweg 577, 2132 NA Hoofddorp, The Netherlands www
.omron-healthcare.com
OMRON DALIAN CO., LTD.
Economic & Technical Development Zone, Dalian 116600, China
OMRON HEALTHCARE UK LTD.
Opal Drive, Fox Milne, Milton Keynes MK15 0DG, United Kingdom
OMRON Medizintechnik Handelsgesellschaft mbH
John-Deere-Str. 81a, 68163 Mannheim, Germany www.omron-medizintechnik.de
OMRON SANTÉ FRANCE SAS
14, rue de Lisbonne, 93561 Rosny-sous-Bois Cedex, France
Made in China
Loading...