Omron HEM-6140-E User Manual

Wrist Blood
Pressure Monitor
Model
MIT Quick Check 3
Instruction Manual
Introduction
Thank you for purchasing the OMRON MIT Quick Check 3 Wrist Blood Pressure Monitor.
The OMRON MIT Quick Check 3 is a compact and easy to use blood pressure monitor, operating on the oscillometric principle. It measures your blood pressure and pulse rate simply and quickly. For comfortable controlled inflation without the need of pressure pre-setting or re-inflation the device uses its advanced “IntelliSense” technology.
Please read this instruction manual thoroughly before using the unit. Please keep for future reference. For specific information about your own blood pressure, CONSULT YOUR DOCTOR.
Important Safety Information
Consult your doctor prior to using in pregnancy or if diagnosed with arrhythmia or arteriosclerosis.
Warning:
• Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
(General Usage)
• Always consult your doctor. Self-diagnosis of measurement results and self-treatment are dangerous.
• People with severe blood flow problems, or blood disorders, should consult a doctor before using the unit, as cuff inflation can cause internal bleeding.
(Battery Usage)
• If battery fluid should get in your eyes, immediately rinse with plenty of clean water. Consult a doctor immediately.
Caution:
• Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury to the user or patient or damage to the equipment or other property.
(General Usage)
• Do not leave the unit unattended with infants or persons who cannot express their consent.
• Do not use the unit for any purpose other than measuring blood pressure.
• Do not use a mobile phone or other devices that emit electromagnetic fields, near the unit. This may result in incorrect operation of the unit.
• Do not disassemble the unit or wrist cuff.
• Do not operate the unit in a moving vehicle (car, airplane).
(Battery Usage)
• If battery fluid should get on your skin or clothing, immediately rinse with plenty of clean water.
• Use only two “AAA” alkaline or manganese batteries with this unit. Do not use other types of batteries.
• Do not insert the batteries with their polarities incorrectly aligned.
• Replace old batteries with new ones immediately. Replace both batteries at the same time.
• Remove the batteries if the unit will not be used for three months or more.
• Do not use new and used batteries together.
General Precautions
• Do not apply strong shocks and vibrations to or drop the unit.
• Do not take measurements after bathing, drinking alcohol or caffeine, smoking, exercising or eating.
• Do not inflate the wrist cuff when it is not wrapped around your wrist.
• Read and follow the “Important information regarding Electro Magnetic Compatibility (EMC)” in the Technical Data Section.
• Read and follow the “Correct Disposal of This Product” in the Technical Data Section when disposing of the device and any used accessories or optional parts.
1 Know your unit
Main unit:
Wrist cuff
Battery compartment
Display
Components:
Wrist Blood
Pressure Monitor
Model MIT Quick Check 3 Instruction Manual
Introduction
Thank you for purchasing the OMRON MIT Quick Check 3 Wrist Blood Pressure Monitor.
The OMRON MIT Quick Check 3 is a compact and easy to use blood pressure monitor, operating on the oscillometric principle. It measures your blood pressure and pulse rate simply and quickly. For comfortable controlled inflation without the need of pressure pre-setting or re-inflation the device uses its advanced “IntelliSense” technology.
Intended Use This product is designed to measure the blood pressure and pulse rate of people within the range of the designated wrist cuff. It is mainly designed for general household use.
2 “AAA” Alkaline Batteries
Instruction Manual
IM-HEM-6140-E-01-05/2014
Date/Time setting button
START/STOP button
Memory button
IM-HEM-6140-E-01-05/2014
5344801-6A
Storage Case
5344801-6A
Display:
Date/Time display
Memory symbol
Systolic blood pressure
Diastolic blood pressure
Low battery symbol
Heartbeat symbol
(Flashes during
measurement)
Cuff wrap guide symbol
Blood pressure level indicator
Irregular heartbeat symbol Deflation symbol
Pulse display / Memory number
Display symbols:
Irregular Heartbeat Symbol ( )
When the monitor detects an irregular rhythm two or more times during the measurement, the irregular heartbeat symbol will appear on the display with the measurement values. An irregular heartbeat rhythm is defined as a rhythm that is 25% less or 25% more than the average rhythm detected while the monitor is measuring the systolic and diastolic blood pressure. If the irregular heartbeat symbol displays with your measurement results, we recommend you consult your physician. Follow the directions of your physician.
Blood pressure
Blood pressure
Cuff Wrap Guide Symbol ( / )
If the cuff was wrapped too loosely, it may cause unreliable values. If the wrapping of cuff is too loose, the cuff wrap guide symbol appears. Otherwise appears. This is the function which is used
as an aid in determining if the cuff is wrapped snugly enough.
Blood pressure Level Indicator
Blood pressure level indicator will light up between the systolic blood pressure and the diastolic blood pressure.
2013 ESH/ESC Guidelines for the management of arterial hypertension
Recent research suggests that the following values can be used as a guide to high blood pressure for measurements taken in office or at home.
Office Home
Systolic Blood Pressure  140 mmHg  135 mmHg
Diastolic Blood Pressure  90 mmHg  85 mmHg
Normal Heartbeat
Pulse
Irregular Heartbeat
Pulse
Short
Long
2Preparation
2.1 Installing/Replacing the Batteries
Remove the battery cover.
1.
Insert two 1.5V “AAA”
2.
batteries as indicated in the battery compartment and then replace the battery cover.
Notes:
• If the battery low symbol ( ) appears on the display, turn off the unit then replace both batteries at the same time.
• The measurement values continue to be stored in memory even after the batteries are replaced.
Disposal of used batteries should be carried out in accordance with the national regulations for the disposal of batteries.
2.2 Setting the Date and Time
Press and hold the button until the year
1.
flashes on the display.
Set the monitor to the correct date and time
2.
before taking a measurement for the first time.
1) Press the button to change.
• Hold down to advance the digit rapidly.
2) Press the button to confirm.
• Next setting appears.
Year
Month
Day
Hour
Minute
Press the START/STOP button to store the
3.
setting.
Notes:
• If the batteries have been removed, the date and time setting will need to be reset.
• If the date and time are not set, “-:--” appears during or after measurement.
3 Using the Unit
3.1 Applying the Wrist Cuff
Do not apply over clothing.
Place the wrist cuff over
1.
your wrist.
Your palm should face upward.
Wrap the wrist cuff around
2.
your wrist.
Wrap the wrist cuff securely around the wrist for taking accurate measurements.
Make sure that the wrist cuff does not cover the protruding part of the wrist bone (ulna) on the outside of the wrist.
Note: You can take a
measurement on either your left or right wrist.
3.2 How to Sit Correctly
To take a measurement, you need to be relaxed and comfortably seated, under comfortable room temperature. No bathing, drinking alcohol or caffeine, smoking, exercising or eating 30 minutes before taking a measurement.
• Sit on a chair with your feet flat on the floor.
• Sit upright with your back straight.
• The cuff should be at the same level as your heart.
• Relax your wrist and hand. Do not bend your wrist back, clench your fist, or bend your wrist forward.
3.3 Taking a Reading
Notes:
• To cancel a measurement, press the START/STOP button at any time during measurement.
• Remain still while taking a measurement.
Press the START/STOP button.
1.
All the symbols appear on the display. The wrist cuff will start to inflate automatically.
Cuff Wrapping Guide Symbol
START INFLATE DEFLATE COMPLETE
Undo the wrist cuff and remove the unit.
2.
Press the START/STOP button to turn off the
3.
monitor.
The monitor automatically stores the measurement in its memory. It will automatically turn off after two minutes.
Notes:
• Wait 2 - 3 minutes before taking another blood pressure measurement. Waiting between readings allows the arteries to return to the condition prior to taking the blood pressure measurement.
• The blood pressure can differ between the right arm and the left arm, and therefore also the measured blood pressure values can be different. OMRON recommends to always use the same arm for measurement. If the values between the two arms differ substantially, please check with your physician which arm to use for your measurement.
Alternating
date/time display
3.4 Using the Memory Function
The unit automatically stores up to 60 sets of measurement values (blood pressure and pulse rate). Notes:
• If the memory is full, the monitor will delete the oldest readings.
• When viewing the reading taken without setting the date and time, “-:--” is displayed instead of the date and time.
To View the Readings Stored in Memory
Press the button, the latest value is displayed.
1.
The Memory number appears for a second before the pulse rate is displayed. The newest set is numbered “1”.
Press the button repeatedly to view the
2.
Alternating date/time display
readings stored in memory.
To Delete All the Values Stored in Memory
When the memory symbol ( ) appears, first press the button. Then while holding it down, press the
START/STOP button simultaneously for about 2 - 3 seconds.
First Second
Note: You cannot partially delete the stored readings.
4 Troubleshooting and Maintenance
4.1 The Icons and Error Messages
Error Display Cause Remedy
Remove the wrist cuff. Wait
2 - 3 minutes and then take Irregular heartbeats are detected.
The batteries are
Blink
low.
The batteries are
Lit
exhausted.
Wrist cuff not applied correctly.
Movement during measurement.
Wrist cuff not applied correctly, or movement during measurement.
Device error.
Note: The irregular heartbeat symbol ( ) may also be displayed
with error messages.
another measurement.
Repeat the steps in section
3.3. If this error continues to
appear, contact your doctor.
You should replace them with
new ones ahead of time.
Refer to section 2.1.
You should replace them with
new ones at once.
Refer to section 2.1.
Apply the wrist cuff correctly.
Refer to section 3.1.
Repeat Measurement while
remaining still and refraining
from talking during the
measurement.
Refer to section 3.3.
Apply the wrist cuff correctly
and repeat measurement
while remaining still and
refraining from talking during
the measurement.
Refer to section 3.1 and 3.3.
Contact your OMRON retail
outlet or distributor.
4.2 Troubleshooting
5 Technical Data
6 Warranty
7
Some Useful Information about Blood Pressure
Problem Cause Remedy
Measure while in the correct posture. Refer to section 3.2.
Wrap the cuff correctly. Refer to section 3.1.
The reading is
The wrist cuff is not at heart level.
The cuff is not wrapped snugly
around the wrist. extremely low (or high).
Wrist cuff pressure does not rise.
The arms and
shoulders are
tense.
Movement or
talking during
measurement.
Air is leaking from
the wrist cuff.
Relax and try taking the measurement again. Refer to section 3.3.
Remain still and do not talk during Measurement. Refer to section 3.3.
Consult your OMRON retail outlet or distributor.
Apply the cuff correctly so Wrist cuff deflates too soon.
The wrist cuff is loose.
that it is firmly wrapped
around the wrist. Refer to
section 3.1.
Blood pressure readings
constantly vary with time The blood pressure is different each time. The reading is extremely low (or high).
of day and how relaxed
you are. Take several
deep breaths and try to
remain relaxed before
taking a measurement.
The unit loses power during measurement.
Nothing happens when you press the buttons.
The batteries are exhausted.
The batteries have been inserted incorrectly.
Replace the batteries with
new ones.
Refer to section 2.1.
Insert the batteries with
the correct (+/-) polarity.
Refer to section 2.1.
• Press the START/STOP button and repeat measurement.
Other problems.
• If the problem continues, try replacing the batteries with new ones.
If this still does not solve the problem, contact your OMRON retail outlet or distributor.
4.3 Maintenance
To protect your unit from damage, please observe the following:
• Do not subject the main unit and the cuff to extreme temperatures, humidity, moisture or direct sunlight.
• Do not disassemble the unit.
• Do not subject the unit to strong shocks or vibrations (for example, dropping the unit on the floor).
• Do not use volatile liquids to clean the main unit.
• Do not wash the cuff or immerse it in water.
• Do not use petrol, thinners or similar solvents to clean the cuff.
• Do not carry out repairs of any kind yourself. If a defect occurs, consult your OMRON retail outlet or distributor as mentioned on the packaging.
• The unit should be cleaned with a soft, dry cloth.
• Use a soft, moistened cloth and soap to clean the cuff.
• Keep the unit in its storage case when not in use.
• Fold the cuff into the storage case.
Do not store the unit in the following situations:
• If the unit is wet.
• Locations exposed to extreme temperatures, humidity, direct sunlight, dust or corrosive vapours.
• Locations exposed to vibrations, shocks or where it will be at an angle.
Calibration and Service
• The accuracy of this blood pressure monitor has been carefully tested and is designed for a long service life.
• It is generally recommended to have the unit inspected every two years to ensure correct functioning and accuracy. Please consult your authorised OMRON dealer or the OMRON Customer Service at the address given on the packaging or attached literature.
Product description OMRON Wrist Blood Pressure Monitor Model MIT Quick Check 3 (HEM-6140-E) Display LCD Digital Display Measurement method Oscillometric method Measurement range Pressure: 0 to 299 mmHg
Pulse: 40 to 180 beats/min.
Accuracy Pressure: ±3 mmHg
Pulse: ±5% of display reading Inflation Automatic inflation by pump Deflation Automatic rapid deflation Memory 60 Measurements Power source 2 “AAA” batteries 1.5V Battery life Approx. 300 measurements with new
alkaline batteries at a room temperature of
23°C
Applied part
Protection against
= Type BF
Internally powered ME equipment electric shock
Operating temperature/
+10 to +40°C / Maximum: 15 to 85% RH Humidity Storage temperature/ humidity/air pressure
-20 to +60°C / Maximum: 10 to 95% RH /
700 to 1060hPa Console weight Approximately 123g without batteries Outer dimensions Approximately 86.7 (w) mm x 67 (h) mm x
28 (d) mm (without the wrist cuff) Measurable
Approximately 13.5 to 21.5 cm circumference Cuff material Nylon and polyester
Package content Main unit, storage case, battery set,
instruction manual
Note: Subject to technical modification without prior notice.
• This device fulfils the provisions of EC directive 93/42/EEC
(Medical Device Directive).
• This blood pressure monitor is designed according to the European
Standard EN1060, Non-invasive sphygmomanometers Part 1: General Requirements and Part 3: Supplementary requirements for electromechanical blood pressure measuring systems.
• This OMRON product is produced under the strict quality system of
OMRON HEALTHCARE Co. Ltd., Japan. The Core component for OMRON blood pressure monitors, which is the Pressure Sensor, is produced in Japan.
Important information regarding Electro Magnetic Compatibility (EMC)
With the increased number of electronic devices such as PC’s and mobile (cellular) telephones, medical devices in use may be susceptible to electromagnetic interference from other devices. Electromagnetic interference may result in incorrect operation of the medical device and create a potentially unsafe situation. Medical devices should also not interfere with other devices.
In order to regulate the requirements for EMC (Electro Magnetic Compatibility) with the aim to prevent unsafe product situations, the EN60601-1-2:2007 standard has been implemented. This standard defines the levels of immunity to electromagnetic interferences as well as maximum levels of electromagnetic emissions for medical devices.
This medical device manufactured by OMRON HEALTHCARE conforms to this EN60601-1-2:2007 standard for both immunity and emissions. Nevertheless, special precautions need to be observed:
• Do not use mobile (cellular) telephones and other devices, which generate strong electrical or electromagnetic fields, near the medical device. This may result in incorrect operation of the unit and create a potentially unsafe situation. Recommendation is to keep a minimum distance of 7 m. Verify correct operation of the device in case the distance is shorter.
Further documentation in accordance with EN60601-1-2:2007 is available at OMRON HEALTHCARE EUROPE at the address mentioned in this instruction manual. Documentation is also available at www.omron-healthcare.com.
Correct Disposal of This Product (Waste Electrical & Electronic Equipment)
This marking shown on the product or its literature, indicates that it should not be disposed of, with other household wastes at the end of its working life.
To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate this product from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources.
Household users should contact either the retailer where they purchased this product, or their local government office, for details of where and how they can return this item for environmentally safe recycling. Business users should contact their supplier and check the terms and conditions of the purchase contract. This product should not be mixed with other commercial wastes for disposal.
Thank you for buying an OMRON product. This product is constructed of high quality materials and great care has been taken in its manufacturing. It is designed to give you every satisfaction, provided that it is properly operated and maintained as described in the instruction manual. This product is guaranteed by OMRON for a period of 2 years after the date of purchase. The proper construction, workmanship and materials of this product is guaranteed by OMRON. During this period of guarantee OMRON will, without charge for labour or parts, repair or replace the defect product or any defective parts.
The guarantee does not cover any of the following:
a. Transport costs and risks of transport. b. Costs for repairs and / or defects resulting from repairs done by
unauthorised persons. c. Periodic check-ups and maintenance. d. Failure or wear of attachments other than the main device itself,
unless explicitly guaranteed above. e. Costs arising due to non-acceptance of a claim (those will be
charged for). f. Damages of any kind including personal caused accidentally or
from misuse. g. Calibration service is not included within the guarantee.
Should guarantee service be required please apply to the dealer whom the product was purchased from or an authorised OMRON distributor. For the address refer to the product packaging / literature or to your specialised retailer.
If you have difficulties in finding OMRON customer services, contact us for information.
www.omron-healthcare.com
Repair or replacement under the guarantee does not give rise to any extension or renewal of the guarantee period. The guarantee will be granted only if the complete product is returned together with the original invoice / cash ticket issued to the consumer by the retailer.
What is Blood Pressure?
Blood pressure is a measure of the force of blood flowing against the walls of the arteries. Arterial blood pressure is constantly changing during the course of the heart’s cycle. The highest pressure in the cycle is called the Systolic Blood Pressure; the lowest is the Diastolic Blood Pressure. Both pressures, the Systolic and Diastolic, are necessary to enable a physician to evaluate the status of a patient’s blood pressure.
What is Arrhythmia?
Arrhythmia is a condition where the heartbeat rhythm is abnormal due to flaws in the bio-electrical system that drives the heartbeat. Typical symptoms are skipped heartbeats, premature contraction, an abnormally rapid (tachycardia) or slow (bradycardia) pulse.
Why is it a Good Thing to measure Blood Pressure at Home?
Many factors such as physical activity, anxiety, or the time of day, can influence your blood pressure. A single measurement may not be sufficient for an accurate diagnosis. Thus it is best to try and measure
200
150
mmHg
100
50
61218 24
Example: fluctuation within a day (male, 35 years old)
your blood pressure at the same time each day, to get an accurate indication of any changes in blood pressure. Blood pressure is typically low in the morning and increases from afternoon to evening. It is lower in the summer and higher in the winter.
Upper curve: systolic blood pressure Lower curve: diastolic blood pressure
Time of day
How are hypertension and irregular heartbeat linked to stroke?
Hypertension (high blood pressure) and atrial fibrillation are two major risk factors of stroke. Irregular heartbeat is a potential indicator of atrial fibrillation. Omron Blood Pressure monitors can help to detect hypertension and irregular heartbeat*. If either or both are indicated by the device, we recommend to consult your doctor. NOTE: Diagnosis can only be made by a doctor * Irregular heartbeat detection is available on most Omron blood
pressure monitors.
Manufacturer
EU-representative
Production facility
Subsidiaries
OMRON HEALTHCARE Co., Ltd.
53, Kunotsubo, Terado-cho, Muko, KYOTO, 617-0002 JAPAN
OMRON HEALTHCARE EUROPE B.V.
Scorpius 33, 2132 LR Hoofddorp, THE NETHERLANDS www.omron-healthcare.com
OMRON HEALTHCARE MANUFACTURING VIETNAM CO., LTD.
No.28 VSIP II, Street 2, Vietnam-Singapore Industrial Park II, Binh Duong Industry-Services-Urban Complex, Hoa Phu Ward, Thu Dau Mot City, Binh Duong Province, Vietnam
OMRON HEALTHCARE UK LTD.
Opal Drive, Fox Milne, Milton Keynes, MK15 0DG, UK www.omron-healthcare.co.uk
OMRON MEDIZINTECHNIK HANDELSGESELLSCHAFT mbH
Gottlieb-Daimler-Strasse 10, 68165 Mannheim, GERMANY www.omron-healthcare.de
OMRON SANTÉ FRANCE SAS
14, rue de Lisbonne, 93561 Rosny-sous-Bois Cedex, FRANCE www.omron-healthcare.fr
Made in Vietnam
Loading...