Large White PV Display That’s Easier to Read.
Easy to Use, from Model Selection to
(E5CC-800/-U-800) (E5CC-B-800)
(48 × 48 mm)
*
Setup and Operation.
Models with Push-In Plus Terminal
Blocks Added to Lineup.
• The white PV display with a height of 15.2 mm improves
visibility.
• High-speed sampling at 50 ms.
• Select from models with screw terminal blocks, models with
Push-In Plus terminal blocks for reduced wiring work, and
Plug-in Models that can be removed from the terminal block.
• Short body with depth of only 60 mm. (Screw Terminal Blocks)
• Easy connections to a PLC with programless communications.
Use component communications to link Temperature
Controllers to each other.
Main I/O Functions
1
E5CC-800/E5CC-B-800/E5CC-U-800
Model Number Legend and Standard Models
Model Number Legend
●Models with Screw Terminal Blocks
E5CC-800 48 × 48 mm
Control output 1Auxiliary output Communications Heater burnoutEvent inputsPower supply voltageModel
Relay output
Voltage outputE5CC-QX2ASM-800
Linear current outputE5CC-CX2ASM-800
Relay output
Voltage outputE5CC-QX2DSM-800
Linear current outputE5CC-CX2DSM-800
Relay output
Voltage outputE5CC-QX2ASM-801
Relay output
Voltage outputE5CC-QX2DSM-801
Relay output
Voltage outputE5CC-QX2ASM-802
Relay output
Voltage outputE5CC-QX2DSM-802
Linear current output
Linear current output24 VAC/VDCE5CC-CX2DSM-804
Note: Draw-out-type models of the E5CC-800 are available. Ask your OMRON representative for details.
Two
-
RS-485
--
Two
One
-
-Two
100 to 240 VAC
24 VAC/VDC
100 to 240 VAC
24 VAC/VDC
100 to 240 VAC
24 VAC/VDC
100 to 240 VACE5CC-CX2ASM-804
●Models with Push-In Plus Terminal Blocks
E5CC-B-800 48 × 48 mm
Control output 1Auxiliary output Communications Heater burnoutEvent inputsPower supply voltageModel
Relay output
Voltage outputE5CC-QX2ABM-800
Linear current outputE5CC-CX2ABM-800
Relay output
Voltage outputE5CC-QX2ABM-802
Linear current output-TwoE5CC-CX2ABM-804
Two
--
RS-485
One
100 to 240 VAC
E5CC-RX2ASM-800
E5CC-RX2DSM-800
E5CC-RX2ASM-801
E5CC-RX2DSM-801
E5CC-RX2ASM-802
E5CC-RX2DSM-802
E5CC-RX2ABM-800
E5CC-RX2ABM-802
●Plug-in Models
E5CC-U-800 48 × 48 mm
Control output 1Auxiliary output Communications Heater burnoutEvent inputsPower supply voltageModel
Relay output
Voltage outputE5CC-QX2AUM-800
Relay output
Voltage outputE5CC-QX2DUM-800
Two---
100 to 240 VAC
24 VAC/VDC
E5CC-RW2AUM-800
E5CC-RW2DUM-800
Heating and Cooling Control
● Using Heating and Cooling Control
A Control Output Assignment
An auxiliary output is used as the cooling control output.
B Control
If PID control is used, you can set PID control separately for heating and cooling.
This allows you to handle control systems with different heating and cooling response characteristics.
2
Optional Products (Order Separately)
Terminal Covers (for E5CC-800)
Model
E53-COV17
E53-COV23 (3pcs)
Note: The E53-COV10 cannot be used.
Refer to page 14 for the mounted dimensions.
Waterproof Packing
Model
Y92S-P8
Note: This Waterproof Packing is provided only with E5CC-800/
E5CC-B-800 Controllers.
The E5CC-U-800 cannot be waterproofed even if the
Waterproof Packing is attached.
Current Transformers (CTs)
Hole diameterModel
5.8 mmE54-CT1
5.8 mmE54-CT1L *
12.0 mmE54-CT3
12.0 mmE54-CT3L *
* Lead wires are included with these CTs. If UL certification is
required, use these CTs.
Adapter
Model
Y92F-45
Note: Use this Adapter when the panel has already been prepared for
an E5B@ Controller.
DIN Track Mounting Adapter (for E5CC-800)
Model
Y92F-52
E5CC-800/E5CC-B-800/E5CC-U-800
Sockets (for E5CC-U-800)
TypeModel
Front-connecting SocketP2CF-11
Front-connecting Socket with Finger ProtectionP2CF-11-E
Back-connecting SocketP3GA-11
Terminal Cover for Back-connecting socket
with Finger Protection
Waterproof Cover
Model
Y92A-48N
Mounting Adapter
Model
Y92F-49
Note: This Mounting Adapter is provided with the Digital Temperature
Controller.
Front Covers
TypeModel
Hard Front CoverY92A-48H
Soft Front CoverY92A-48D
Y92A-48G
3
E5CC-800/E5CC-B-800/E5CC-U-800
Specifications
Ratings
Power supply voltage
Operating voltage range85% to 110% of rated supply voltage
Power consumption
Sensor input
Input impedance
Control methodON/OFF control or 2-PID control (with auto-tuning)
Relay output
Control
output
Auxiliary
output
Event input
*1*2
Setting methodDigital setting using front panel keys
Indication method
Multi SP
Other functions
Ambient operating temperature-10 to 55°C (with no condensation or icing)
Ambient operating humidity25% to 85%
Storage temperature-25 to 65°C (with no condensation or icing)
Altitude2,000 m max.
Recommended fuseT2A, 250 VAC, time lag, low-breaking capacity
Installation environmentOvervoltage category II, Pollution Degree 2 (EN/IEC/UL 61010-1)
*1 There are no optional functions for the E5CC-U-800. Refer to Model Number Legend on page 2.
*2 There are no optional functions for the E5CC-B-800. Refer to Model Number Legend on page 2.
Voltage output
(for driving SSR)
Linear current output *1 4 to 20 mA DC/0 to 20 mA DC, load: 500 Ω max., resolution: approx. 10,000
Number of outputs2
Output specifications
Number of inputs2 (depends on model)
External contact input
specifications
A in model number: 100 to 240 VAC, 50/60 Hz
D in model number: 24 VAC, 50/60 Hz; 24 VDC
Models with option selection of 800: 5.2 VA max. at 100 to 240 VAC, and 3.1 VA max. at 24 VAC or
All other models: 6.5 VA max. at 100 to 240 VAC, and 4.1 VA max. at 24 VAC or 2.3 W max. at 24 VDC
Temperature input
Thermocouple: K, J, T, E, L, U, N, R, S, B, C/W, or PL II
Platinum resistance thermometer: Pt100 or JPt100
Infrared temperature sensor (ES1B): 10 to 70°C, 60 to 120°C, 115 to 165°C, or 140 to 260°C
Analog input
Current input: 4 to 20 mA or 0 to 20 mA
Voltage input: 1 to 5 V, 0 to 5 V, 0 to 10 V,or 0 to 50 mV (The 0 to 50 mV range applies to the
E5CC-U-800 only for those manufactured in May 2014 or later.)
Current input: 150 Ω max., Voltage input: 1 MΩ min.
(Use a 1:1 connection when connecting the ES2-HB-N/THB-N.)
SPST-NO relay outputs, 250 VAC, E5CC-800/E5CC-U-800 models with 2 output: 3 A (resistive load),
E5CC-B-800 models with 2 outputs: 2 A (resistive load)
Electrical life: 100,000 operations, Minimum applicable load: 10 mA at 5 V
Contact input: ON: 1 kΩ max., OFF: 100 kΩ min.
Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.
Current flow: Approx. 7 mA per contact
11-segment digital display and individual indicators
Character height: PV: 15.2 mm, SV: 7.1 mm
Up to eight set points (SP0 to SP7) can be saved and selected using event inputs, key operations, or
serial communications.
Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater
burnout (HB) alarm (including SSR failure (HS) alarm), 40% AT, 100% AT, MV limiter, input digital
filter, self tuning, PV input shift, run/stop, protection functions, temperature status display, moving
average of input value
imum applicable load: 5 V, 10 mA (reference value)
applicable load: 5 V, 10 mA (reference value)
1.6 W max. at 24 VDC
4
E5CC-800/E5CC-B-800/E5CC-U-800
Temperature range (°C)
Input Ranges (Universal inputs)
●Thermocouple/Platinum Resistance Thermometer
Sensor
type
Sensor
specifica-
tion
Set value
Shaded settings are the default settings.
The applicable standards for the input types are as follows:
K, J, T, E, N, R, S, B: JIS C 1602-2015, IEC 60584-1JPt100: JIS C 1604-1989, JIS C 1606-1989
L: Fe-CuNi, DIN 43710-1985Pt100: JIS C 1604-1997, IEC 60751
U: Cu-CuNi, DIN 43710-1985PL II: According to Platinel II electromotive force charts from BASF (previously Engelhard)
C/W: W5Re/W26Re, JIS C 1602-2015, ASTM E988-1990
Platinum resistance
thermometer
Pt100JPt100KJTELUNRSB
2300
1800
1700
1600
1500
1400
1300
1200
1100
1000
850850850
900
800
700
600
500
400
300
200
100
-100
-200
500.0500.0500.0
100.0100.0
0
-200
0.00.000000000
-199.9199.9
130013001300
400.0
400
-20.0
-100
-200-200
-20.0
400.0
-199.9
Thermocouple
600
400
-100
-200-200
400.0
-199.9
C/W
2300
1800
1700 1700
100
-200
Infrared temperature
sensor
10 to
70°C
90
60 to
120°C
120 165
PLII
0123456789101112131415161718192021222324
115 to
165°C
140 to
260°C
260
●Analog input
Input typeCurrentVoltage
Input specification
Setting range
Set value252627282930
* The range applies to the E5CC-U-800 only for those manufactured in May 2014 or later.
4 to 20 mA0 to 20 mA
1 to 5 V0 to 5 V0 to 10 V0 to 50 mV *
Usable in the following ranges by scaling:
-1999 to 9999, -199.9 to 999.9,
-19.99 to 99.99 or -1.999 to 9.999
5
E5CC-800/E5CC-B-800/E5CC-U-800
*5
0
X
ON
OFFSP
0
X
ON
OFFSP
0
X
ON
OFFSP
0
X
ON
OFFSP
0
X
ON
OFFMV
0
X
ON
OFFMV
0
X
ON
OFFMV
0
X
ON
OFFMV
0
X
ON
OFFMV
0
X
ON
OFFMV
Alarm Outputs
Each alarm can be independently set to one of the following 19 alarm types. The default is 2: Upper limit. (see note.)
Auxiliary outputs are allocated for alarms. ON delays and OFF delays (0 to 999 s) can also be specified.
Note:
In the default settings for models with HB or HS alarms, alarm 1 is set to a heater alarm (HA) and the Alarm Type 1 parameter is not displayed.
To use alarm 1, set the output assignment to alarm 1.
Set
value
Alarm type
When alarm value X
Alarm output operation
When alarm value X
is positive
is negative
0Alarm function OFFOutput OFFNo alarm
1Upper- and lower-limit *1
2
(default)
Upper-limit
3Lower-limit
Upper- and lower-limit
4
range *1
Upper- and lower-limit with
5
standby sequence *1
Upper-limit with standby
6
sequence
Lower-limit with standby
7
sequence
8Absolute-value upper-limit
9Absolute-value lower-limit
Absolute-value upper-limit
10
with standby sequence
Absolute-value lower-limit
11
with standby sequence
12
LBA (alarm 1 type only)
ON
OFFPV
ON
OFFPV
ON
OFFPV
ON
OFFPV
ON
OFFPV
ON
OFFPV
ON
OFFPV
ON
OFFPV
ON
OFFPV
ON
OFFPV
ON
OFFPV
SP
X
SP
X
SP
LH
SP
LH
SP
X
SP
X
SP
X
0
X
0
X
0
X
0
*2
X
ON
OFFPV
ON
OFFPV
SP
X
SP
*3
*4
X
ON
OFFPV
ON
OFFPV
ON
OFFPV
ON
OFFPV
ON
OFFPV
ON
OFFPV
SP
X
SP
X
0
X
0
X
0
X
0
-*7
LH
13PV change rate alarm-*8
SP absolute value
14
upper limit alarm
SP absolute value
15
lower limit alarm
Standard ControlStandard Control
Description of function
Set the upward deviation in the set point for the alarm upper limit (H) and the lower deviation in the set point for the
alarm lower limit (L). The alarm is ON when the PV is outside this deviation range.
Set the upward deviation in the set point by setting the
alarm value (X). The alarm is ON when the PV is higher
than the SP by the deviation or more.
Set the downward deviation in the set point by setting the
alarm value (X). The alarm is ON when the PV is lower than
the SP by the deviation or more.
Set the upward deviation in the set point for the alarm upper limit (H) and the lower deviation in the set point for the
alarm lower limit (L). The alarm is ON when the PV is inside
this deviation range.
A standby sequence is added to the upper- and lower-limit
alarm (1). *6
A standby sequence is added to the upper-limit alarm (2).
*6
A standby sequence is added to the lower-limit alarm (3).
*6
The alarm will turn ON if the process value is larger than
the alarm value (X) regardless of the set point.
The alarm will turn ON if the process value is smaller than
the alarm value (X) regardless of the set point.
A standby sequence is added to the absolute-value upperlimit alarm (8). *6
A standby sequence is added to the absolute-value lowerlimit alarm (9). *6
This alarm type turns ON the alarm when the set point (SP)
is higher than the alarm value (X).
This alarm type turns ON the alarm when the set point (SP)
is lower than the alarm value (X).
16
17
6
MV absolute value
upper limit alarm *9
MV absolute value
lower limit alarm *9
Heating/Cooling
Control (Heating MV)
Heating/Cooling
Control (Heating MV)
Always ON
Standard ControlStandard Control
Heating/Cooling
Control (Cooling MV)
Heating/Cooling
Control (Cooling MV)
Always ON
This alarm type turns ON the alarm when the manipulated
variable (MV) is higher than the alarm value (X).
This alarm type turns ON the alarm when the manipulated
variable (MV) is lower than the alarm value (X).
E5CC-800/E5CC-B-800/E5CC-U-800
LH
H<0, L>0
|H| < |L|
SP
Case 1
LH
H>0, L<0
|H| > |L|
SP
Case 2
LH
H<0, L<0
SP
LH
H<0, L>0
|H| ≥ |L|
SP
LH
H>0, L<0
|H| ≤ |L|
SP
Case 3 (Always ON)
LH
H<0, L>0
|H| < |L|
SP
Case 1
LH
H>0, L<0
|H| > |L|
SP
Case 2
LH
H<0, L<0
SP
LLH
H<0, L>0
|H| ≥ |L|
SP
H
H>0, L<0
|H| ≤ |L|
SP
Case 3 (Always OFF)
*1 With set values 1, 4 and 5, the upper and lower limit values can be set
independently for each alarm type, and are expressed as “L” and “H.”
*2 Set value: 1, Upper- and lower-limit alarm
*3 Set value: 4, Upper- and lower-limit range
*4 Set value: 5, Upper- and lower-limit with standby sequence
For Upper- and Lower-Limit Alarm Described Above *2
• Case 1 and 2
Always OFF
when the upper-limit and lower-limit hysteresis overlaps.
• Case 3: Always OFF
*5. Set value: 5, Upper- and lower-limit with standby sequence
Always OFF
when the upper-limit and lower-limit hysteresis overlaps.
*6 Refer to the E5@C Digital Controllers User's Manual (Cat. No. H174) for
information on the operation of the standby sequence.
*7 Refer to the E5@C Digital Controllers User's Manual (Cat. No.H174) for
information on the loop burnout alarm (LBA).
*8 Refer to the E5@C Digital Controllers User's Manual (Cat. No. H174) for
information on the PV change rate alarm.
*9 When heating/cooling control is performed, the MV absolute upper limit
alarm functions only for the heating operation and the MV absolute lower
limit alarm functions only for the cooling operation.
7
E5CC-800/E5CC-B-800/E5CC-U-800
Characteristics
E5CC-800/E5CC-B-800
Thermocouple: (±0.3% of indication value or ±1°C, whichever is greater) ±1 digit max. *1
Platinum resistance thermometer: (±0.2% of indication value or ±0.8°C, whichever is greater) ±1 digit max.
Indication accuracy
(at the ambient temperature of 23°C)
Simple transfer output accuracy±0.3% FS max.*2
Influence of temperature *3
Influence of voltage *3
Influence of EMS. (at EN 61326-1)
Input sampling period50 ms
Hysteresis
Proportional band (P)
Integral time (I)0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *5
Derivative time (D)0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *5
Proportional band (P) for cooling
Integral time (I) for cooling0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *5
Derivative time (D) for cooling0 to 9999 s (in units of 1 s), 0.0 to 999.9 s (in units of 0.1 s) *5
Control period0.1, 0.2, 0.5, 1 to 99 s (in units of 1 s)
Manual reset value0.0 to 100.0% (in units of 0.1%)
Alarm setting range-1999 to 9999 (decimal point position depends on input type)
Affect of signal source resistance
Insulation resistance20 MΩ min. (at 500 VDC)
Dielectric strength3,000 VAC, 50/60 Hz for 1 min between terminals of different charge
Vibration
Shock
Weight
Degree of protection
Memory protectionNon-volatile memory (number of writes: 1,000,000 times)
Standards
EMC
*1 The indication accuracy of K thermocouples in the -200 to 1300°C range, T and N thermocouples at a temperature of -100°C max., and U and
L thermocouples at any temperatures is ±2°C ±1 digit max. The indication accuracy of the B thermocouple at a temperature of 400°C max. is
not specified. The indication accuracy of B thermocouples at a temperature of 400 to 800° is ±3°C max. The indication accuracy of the R and
S thermocouples at a temperature of 200°C max. is ±3°C ±1 digit max. The indication accuracy of C/W thermocouples is (±0.3% of PV or ±3°C,
whichever is greater) ±1 digit max. The indication accuracy of PL II thermocouples is ±0.3% of PV or ±2°C, whichever is greater, ±1 digit max.
*2 However, the precision between 0 and 4 mA for a 0 to 20 mA output is ±1% FS max.
*3 Ambient temperature: -10°C to 23°C to 55°C, Voltage range: -15% to 10% of rated voltage
*4 K thermocouple at -100°C max.: ±10°C max.
*5 The unit is determined by the setting of the Integral/Derivative Time Unit parameter.
*6 The E5CC-U plug-in model is certified for UL listing only when used together with the OMRON P2CF-11 or P2CF-11-E Socket. The P3GA-11
is not certified for UL listing.
*7 Access the following website for information on certified models. http://www.ia.omron.com/support/models/index.html
*8 Refer to information on maritime standards in Shipping Standards on page 61 for compliance with Lloyd's Standards.
*9 Industrial electromagnetic environment (EN/IEC 61326-1 Table 2)
Malfunction10 to 55 Hz, 20 m/s2 for 10 min each in X, Y, and Z directions
Resistance10 to 55 Hz, 20 m/s2 for 2 hrs each in X, Y, and Z directions
Malfunction100 m/s2, 3 times each in X, Y, and Z directions
Resistance300 m/s2, 3 times each in X, Y, and Z directions
Approved standards
Conformed standardsEN 61010-1 (IEC 61010-1)
Analog input: ±0.2% FS ±1 digit max.
CT input:±5% FS ±1 digit max.
E5CC-U-800
Thermocouple: (±1% of indication value or ±2°C, whichever is greater) ±1 digit max. *1
Platinum resistance thermometer: (±0.2% of indication value or ±0.8°C, whichever is greater) ±1 digit max.
Analog input: ±0.2% FS ±1 digit max.
Thermocouple input (R, S, B, C/W, PL II): (±1% of indication value or ±10°C, whichever is greater) ±1 digit max.
Other thermocouple input: (±1% of indication value or ±4°C, whichever is greater) ±1 digit max. *4
Platinum resistance thermometer: (±1% of indication value or ±2°C, whichever is greater) ±1 digit max.
Analog input: ±1%FS ±1 digit max.
CT input: ±5% FS ±1 digit max.
Temperature input: 0.1 to 999.9°C or °F (in units of 0.1°C or °F)
Analog input: 0.01% to 99.99% FS (in units of 0.01% FS)
Temperature input: 0.1 to 999.9°C or °F (in units of 0.1°C or °F)
Analog input: 0.1% to 999.9% FS (in units of 0.1% FS)
Temperature input: 0.1 to 999.9°C or °F (in units of 0.1°C or °F)
Analog input: 0.1% to 999.9% FS (in units of 0.1% FS)
E5CC-800/E5CC-B-800: Controller: Approx. 120 g, Adapter: Approx. 10 g
E5CC-U-800: Controller: Approx. 100 g, Adapter: Approx. 10 g
E5CC-800/E5CC-B-800: Front panel: IP66, Rear case: IP20, Terminals: IP00
E5CC-U-800: Front panel: IP50, Rear case: IP20, Terminals: IP00
cULus: UL 61010-1/CSA C22.2 No.61010-1 *6,
Korean wireless regulations (Radio law: KC Mark) (Some models only.) *7, Lloyd's standards *8
EMI: EN 61326-1 *9
Radiated Interference Electromagnetic Field Strength: EN 55011 Group 1, class A
Noise Terminal Voltage:EN 55011 Group 1, class A
EMS:EN 61326-1 *9
ESD Immunity:EN 61000-4-2
Electromagnetic Field Immunity:EN 61000-4-3
Burst Noise Immunity:EN 61000-4-4
Conducted Disturbance Immunity:EN 61000-4-6
Surge Immunity:EN 61000-4-5
Voltage Dip/Interrupting Immunity:EN 61000-4-11
8
E5CC-800/E5CC-B-800/E5CC-U-800
4
Communications Specifications
Transmission line
connection method
Communications
Synchronization
method
ProtocolCompoWay/F, or Modbus
Baud rate *19600, 19200, 38400, or 57600 bps
Transmission codeASCII
Data bit length *17 or 8 bits
Stop bit length *11 or 2 bits
*1 The baud rate, data bit length, stop bit length, and vertical parity
can be individually set using the Communications Setting Level.
*2 Modbus is a registered trademark of Schneider Electric.
RS-485: Multidrop
RS-485 (two-wire, half duplex)
Start-stop synchronization
Vertical parity (none, even, odd)
Block check character (BCC) with
CompoWay/F or CRC-16 with Modbus *2
217 bytes
0 to 99 ms
Default: 20 ms
Communications Functions
You can use the memory in the PLC to read and
write E5@C parameters, start and stop operation,
etc. The E5@C automatically performs communications with PLCs. No communications programming is required.
Number of connected Temperature Controllers:
32 max. (Up to 16 for the FX Series)
Programless
communications
Component
Communications
*2
Copying
MELSEC is a registered trademark of Mitsubishi Electric Corporation.
KEYENCE is a registered trademark of Keyence Corporation.
*1 A Temperature Controller with version 1.1 or higher is required.
A Temperature Controller with version 2.1 or higher is required for
the FX Series or the KV Series.
*2 Both the programless communications and the component
communications support the copying.
Applicable PLCs
*1
*1
OMRON PLCs
CS Series, CJ Series, CP Series, NJ Series,
or NX1P
Mitsubishi Electric PLCs
MELSEC Q Series, L Series, FX3 Series, or
iQ-R Series
KEYENCE PLCs
KEYENCE KV Series
When Digital Temperature Controllers are connected, set points and RUN/STOP commands
can be sent from the Digital Temperature Controller that is set as the master to the Digital Temperature Controllers that are set as slaves.
Slope and offsets can be set for the set point.
Number of connected Digital Temperature Controllers: 32 max. (including master)
When Digital Temperature Controllers are connected, the parameters can be copied from the
Digital Temperature Controller that is set as the
master to the Digital Temperature Controllers that
are set as slaves.
Current Transformer (Order Separately)
Ratings
E54-CT1
E54-CT3
Dielectric strength1,000 VAC for 1 min 1,500 VAC for 1 min
Vibration resistance50 Hz, 98 m/s
Weight
E54-CT1: Approx. 11.5 g,
E54-CT3: Approx. 50 g
E54-CT3 Only
Accessories
Armatures (2)
Plugs (2)
E54-CT1L
E54-CT3L
2
E54-CT1: Approx. 14 g,
E54-CT3: Approx. 57 g
None
Heater Burnout Alarms and SSR Failure
Alarms
CT input (for heater
current detection)
Maximum heater
current
Input current
indication accuracy
Heater burnout
alarm setting range
*1
SSR failure alarm
setting range *2
*1 For heater burnout alarms, the heater current will be measured
when the control output is ON, and the output will turn ON if the
heater current is lower than the set value (i.e., heater burnout
detection current value).
*2 For SSR failure alarms, the heater current will be measured when
the control output is OFF, and the output will turn ON if the heater
current is higher than the set value (i.e., SSR failure detection
current value).
*3 The value is 30 ms for a control period of 0.1 s or 0.2 s.
*4 The value is 35 ms for a control period of 0.1 s or 0.2 s.
Models with detection for single-phase
heaters: One input
50 A AC
±5% FS ±1 digit max.
0.1 to 49.9 A (in units of 0.1 A)
Minimum detection ON time: 100 ms *3
0.1 to 49.9 A (in units of 0.1 A)
Minimum detection OFF time: 100 ms *4
Electrical Life Expectancy Curve for
Control output Relays (Reference
Values)
500
300
operations)
100
50
Life (× 10
30
10
5
E5CC-800/E5CC-B-800
250 VAC, 30 VDC
3
(resistive load)
cosφ = 1
1
0 1 2 3 4 5 6
Switching current (A)
9
E5CC-800/E5CC-B-800/E5CC-U-800
The E5CC-800 is set for a K-type thermocouple (input type = 5) by
default. An input error (UGTT) will occur if the input type setting does
not agree with the temperature sensor. Check the input type.
Control output 1
Relay output
250 VAC, 3A
(resistive load)
Voltage output
(for driving SSR)
12 VDC, 21 mA
Linear current output
0 to 20 mA DC
4 to 20 mA DC
Load: 500 Ω max.
Relay outputs
Models with 2 auxiliary
outputs: 250 VAC, 3 A
(resistive load)
17
1812
15
16
1
2
13
14
3
11
4
6
7
8
9
10
5
6
4
5
6
5
6
Pt
A
B
B
+
-
m
A
-
+
5
4
V
5
V
6
+
4
TC
4
I
(no polarity)
11
12
11
12
100 to 240 VAC24 VAC/VDC
Auxiliary outputs 1, 2
7
8
9
10
Auxiliary output 2
Auxiliary output 1
804
Communications (RS-485),
and Event Inputs 3 and 4
801
Event Inputs 1
and 2, and CT1
802
Communications (RS-485),
CT1
B(+)
A(-)
RS-485
(2) Auxiliary Outputs
(3) Input Power Supply
(5) Sensor (Temperature/Analog) Input
(6) Options
+
-
3
1
2
3
1
2
-
Models with
1 Linear
Current Output
Models with
1 Relay
Output
3
(1) Control outputs 1, 2
OUT1
C
OUT1
Q
OUT1
R
1
2
Models with 1
Voltage Output
(for Driving SSR)
+
RXQXCX
Auxiliary outputs 1, 2
E5CC-@@ 2 @ S M - 8@@
(1) (2)(3) (4)(5)(6)
↑
Terminal type
Use no-voltage inputs for the event inputs.
The polarity for non-contact inputs is given in parentheses.
13
14
15
16
17
18
13
14
15
16
17
18
EV1
EV2
CT1
(-)
CT1
16
17
18
13
14
15
EV3
EV4
B(+)
A(-)
RS-485
(-)
External Connections
E5CC-800 (Screw Terminal Blocks)
Note: 1. The application of the terminals depends on the model.
2. Do not wire the terminals that are shown with a gray background.
3. When complying with EMC standards, the cable that connects the sensor must be 30 m or less.
If the cable length exceeds 30 m, compliance with EMC standards will not be possible.
4. Connect M3 crimped terminals.
5. Due to UL Listing requirements, use the E54-CT1L or E54-CT3L Current Transformer with the factory wiring (internal wiring). Use a UL
category XOBA or XOBA7 current transformer that is UL Listed for field wiring (external wiring) and not the factory wiring (internal wiring).
10
E5CC-B-800 (Push-In Plus Terminal Blocks)
A
13
14
15
16
To another E5@C
Wiring Example:
Control output 1
Relay output
250 VAC, 3A
(resistive load)
Voltage output
(for driving SSR)
12 VDC, 21 mA
(1) Control outputs 1
RX
Models with
1 Relay
Output
1
2
(5) Sensor (Temperature/Analog) Input
(6) Options
OUT1
R
TC
A
6
7
8
+
Models with 1
Voltage Output
(for Driving SSR)
1
2
Pt
6
B
m
7
B
8
QX
802
Communications
(RS-485), CT1
B(+)
17
RS-485
A(-)
CT1
18
19
20
21
22
*
*
23
24
Auxiliary outputs 1, 2
Relay outputs
outputs: 250 VAC, 2 A
(resistive load)
Models with 1
Linear Current Output
OUT1
+
-
I
+
6
7
88
1
Q
2
V
6
7
V
+
804
Communications
(RS-485), and
Event Inputs 3 and 4
B(+)
17
RS-485
A(-)
18
19
20
(-)
21
(-)
22
23
EV3
24
EV4
CX
OUT1
+
C
-
*
*
*
E5CC-800/E5CC-B-800/E5CC-U-800
E5CC-@@ 2 @ B M - 8@@
(1) (2) (3) (4) (5)
Terminal type
The E5CC is set for a K-type thermocouple
(input type = 5) by default. An input error
(s.err) will occur if the input type setting does
not agree with the temperature sensor. Check
the input type.
1
2
3
6
7
8
↑
17
18
19
20412
21513
22
23
2416
(6)
9
10
11
14
15
(2) Auxiliary Outputs
Auxiliary output 2
9
10
13
14
15
16
11
12
*
*
Auxiliary output 1
(3) Input Power Supply
100 to 240 VAC
*
Note: 1. The application of the terminals depends on the model.
2. Do not wire the terminals that are shown with a gray background.
3. When complying with EMC standards, the cable that connects the sensor must be 30 m or less.
If the cable length exceeds 30 m, compliance with EMC standards will not be possible.
@
4. Refer to Wiring Precautions for E5
C-B (Controllers with Push-In Plus Terminal Blocks) on page 65 for wire specifications and wiring
methods.
5. Common terminals are indicated with asterisks (*). You can use the input power supply and communications common terminals for
crossover wiring. Do not exceed the maximum number of Temperature Controllers given below if you use crossover wiring for the input
power supply.
100 to 240 VAC Controllers: 16 max.
6. Due to UL Listing requirements, use the E54-CT1L or E54-CT3L Current Transformer with the factory wiring (internal wiring).
Use a UL category XOBA or XOBA7 current transformer that is UL Listed for field wiring (external wiring) and not the factory wiring
(internal wiring).
11
E5CC-800/E5CC-B-800/E5CC-U-800
A
B
B
+
−
250 VAC, 3 A (resistive load)
Control output 1
•
•
Auxiliary output 1
Relay output
−
+
V
−
mA
+
The E5CC-U is set for a K-type thermocouple (input type =
5) by default. An input error (s.err) will occur if the input
type setting does not agree with the temperature sensor.
Check the input type.
Note: 1. The application of the terminals depends on the model.
2. Do not wire the terminals that are shown with a gray background.
3. When complying with EMC standards, the cable that connects the sensor must be 30 m or less.
If the cable length exceeds 30 m, compliance with EMC standards will not be possible.
4. Connect M3.5 crimped terminals for the E5CC-U-800.
12
Isolation/Insulation Block Diagrams
Communications and event inputs
Sensor input and CT input
Voltage output (for driving SSR) and linear current output
Relay output
Auxiliary output 1
Power
supply
Auxiliary output 2
: Reinforced insulation
: Functional isolation
Sensor input
Voltage output (for driving SSR)
Relay output
Auxiliary outputs 1 and 2
: Reinforced insulation
: Functional isolation
Power
supply
E5CC-800
E5CC-B-800
E5CC-U-800
E5CC-800/E5CC-B-800/E5CC-U-800
• E5CC-800
Models with 2 Auxiliary Outputs
• E5CC-B-800
Models with 2 Auxiliary Outputs
Sensor input and CT input
Power
supply
Voltage output (for driving SSR) and linear current output
: Reinforced insulation
: Functional isolation
Communications
Relay output
Auxiliary outputs 1, 2
Nomenclature
• E5CC-U-800
Models with 2 Auxiliary Outputs
Temperature unit
Front panel
Operation indicators
Press O Key once to go to Adjustment Level.
Press O Key for at least 3 seconds to go to Initial Setting Level.
Top View of E5CC-800
No. 1 display
PV or specified parameter
No. 2 display
SP or specified parameter value
Use the UD Keys to set the
parameter.
Use S Key to change the digit (default setting).
Use the M Key to change to another parameter.
Top View of E5CC-B-800
Top View of E5CC-U-800
13
E5CC-800/E5CC-B-800/E5CC-U-800
48 × 48
4
1
73.1
60
Adapter
(Accessory)
Terminal Cover
(E53-COV17)
(Sold separately)
5848.8
Waterproof Packing
(Accessory)
44.8 × 44.8
44.8 × 44.8
E5CC-800
• Recommended panel thickness is 1 to 5 mm.
• Group mounting is not possible in the vertical direction. (Maintain
the specified mounting space between Controllers.)
• To mount the Controller so that it is waterproof, insert the
waterproof packing onto the Controller.
• When two or more Controllers are mounted, make sure that the
surrounding temperature does not exceed the allowable operating
temperature specified in the specifications.
E5CC-B-800
58
76.8
58.6
4
14.2
48 × 48
Adapter
(Accessory)
44.8 × 44.8
E5CC-U-800
• Recommended panel thickness is 1 to 5 mm.
• Group mounting is not possible in the vertical direction. (Maintain
the specified mounting space between Controllers.)
• When two or more Controllers are mounted, make sure that the
surrounding temperature does not exceed the allowable operating
temperature specified in the specifications.
● Terminal Cover (for the P3GA-11 Back-connecting Socket)
Y92A-48G
Note: You can attach the P3GA-11 Back-connecting Socket for finger protection.
● Waterproof Packing
Y92S-P8 (for DIN 48 × 48)
The Waterproof Packing is provided only with the E5CC-800/E5CC-B-800.
It is not included with the E5CC-U-800.
Order the Waterproof Packing separately if it becomes lost or damaged.
The Waterproof Packing can be used to achieve an IP66 degree of protection.
(Deterioration, shrinking, or hardening of the waterproof packing may occur depending on the
operating environment. Therefore, periodic replacement is recommended to ensure the level of
waterproofing specified in IP66. The time for periodic replacement depends on the operating
environment. Be sure to confirm this point at your site.
Consider three years as a rough standard.)
The E5CC-U-800 cannot be waterproofed even if the Waterproof Packing is attached.
Twelve, 6.4-dia.
E5CC-800/E5CC-B-800/E5CC-U-800
2 3.8
10
Terminal Cover
(E53-COV23)
44.8
34
Y92A-48G
47.4
47.7×47.7
UP
P C
16.5
24.6
48×48
27.6
15
E5CC-800/E5CC-B-800/E5CC-U-800
62.8
To back of the E5CC-800
72 × 72
48 × 48
Panel (1 to 8 mm)
Mounting Adapter
Y92F-30
(Accessory)
2.24.7
Y92F-45
Mounted to E5CC-800
Note: 1. Use this Adapter when the Front Panel has already been prepared for the E5B@.
2. Only black is available.
Y92F-52
Mounted to E5CC-800
Note: 1. This Adapter cannot be used together with the Terminal Cover.
Remove the Terminal Cover to use the Adapter.
2. This Adapter cannot be used with the E5CC-B.
This Adapter is used to mount the
E5CC-800 to a DIN Track.
If you use the Adapter, there is no
need for a plate to mount in the
panel or to drill mounting holes in
the panel.
● Adapter
72 × 72
4.7
76
69.6 to 77.6
Fixture (Accessory)
8767 × 67
● DIN Track Mounting Adapter
50
61
3.5
38
48
80.5
16
E5CC-800/E5CC-B-800/E5CC-U-800
67.6
69
12
21.9 14
(2)
79.2
87.7
28.9
The Mounting Adapter is provided with
the Temperature Controller.
Order this Adapter separately if it
becomes lost or damaged.
This Protective Cover is soft type.
It is able to operate the controller
with using this cover.
Note: This Protective Cover cannot be used
if the Waterproof Packing is installed.
Y92A-48D
This Protective Cover is hard type.
Please use it for the mis-operation
prevention etc.
Note: 1. A model with finger protection (P2CF-11-E) is also available.
2. You cannot use the P2CF-11 or P2CF-11-E together with the Y92F-45.
Note: Can also be mounted
to a DIN track
5 6 7 8
4
3
2
9
10
11
1
25.6
27dia.
45
45
4.5 16.3 6.2
47
3
8.7
6
Terminal Layout/Internal Connections
(Bottom View)
Eleven, M3.5
sems screws
Note: 1. Using any other sockets will adversely affect accuracy. Use only the specified sockets.
2. A Protective Cover for finger protection (Y92A-48G) is also available.
3. You cannot use the P3GA-11 together with the Y92F-45.
● Watertight Cover
Y92A-48N
● Mounting Adapter
Y92F-49
● Protective Cover● Protective Cover
Y92A-48H
● E5CC-U-800 Wiring Socket
Front-connecting Socket
P2CF-11
Eleven, M3.5 × 7.5
sems screws
70 max.
4
50 max.
7.8
Two ,
4.5-dia.
holes
3
31.2 max.
Terminal Layout/Internal Connections
4.5
35.4
Back-connecting Socket
P3GA-11
(Top View)
8
9
10 11
567
4
3
21
Mounting Holes
Two, 4.5 dia. mounting holes
±0.2
40
17
E5CC-800/E5CC-B-800/E5CC-U-800
E54-CT1
Thru-current (Io) vs. Output Voltage (Eo)
(Reference Values)
E54-CT1 or E54-CT1L
Maximum continuous heater current: 50 A (50/60 Hz)
Number of windings: 400
±2
Winding resistance: 18
±2 Ω
Thru-current (Io) A (r.m.s.)
110 100mA110100
1,000A
100V
Frequency: 50 Hz
Distortion
factor
10%
3%
1%
100Ω
RL=10Ω
∞
10
1
100mV
10
1
100μV
10
1kΩ
Output voltage (Eo) V (r.m.s.)
E54-CT1L
5.8 dia.
Filler (epoxy)
Case (PBT)
Shrinkable tube
Two, 3.5 dia.
Cable (AWG18)
25
2.5
115±5
8
21
10.5
40
30
5
15
10
Mark (yellow)
(12)
● Current Transformers
Filler
(epoxy)
25
2.5
5
21
15
5.8 dia.
Case
40
30
2.8
7.5
10.5
10
Two, 3.5 dia.
18
E5CC-800/E5CC-B-800/E5CC-U-800
E54-CT3 Accessories
• Armature
12 dia.
2.36 dia.
Two, M3 (depth: 4)
40 × 40
30
9
30
8
Filler
(epoxy)
Case
(PBT)
15
40
(22)
Approx. 6 dia.
E54-CT3
Connection Example
•Plug
Thru-current (Io) vs. Output Voltage (Eo)
(Reference Values)
E54-CT3 or E54-CT3L
Maximum continuous heater current: 120 A (50/60 Hz)
(Maximum continuous heater current for an OMRON
Digital Temperature Controller is 50 A.)
Number of windings: 400±2
Winding resistance: 8±0.8
Ω
Thru-current (Io) A (r.m.s.)
110 100mA110100
1,000A
100V
Frequency: 50 Hz
Distortion
factor
10%
3%
1%
1kΩ
100Ω
50Ω
RL=10Ω
500Ω
∞
10
1
100mV
10
1
100μV
10
Output voltage (Eo) V (r.m.s.)
Filler (epoxy)
Case (PBT)
Cable (AWG18)
12.0
dia.
30
40
8
4015
100±5
8
Two, M3
(depth: 4)
30
E54-CT3L
Approx. 3 dia.
Plug
18
Armature
Lead
19
MEMO
20
Digital Temperature Controller (Simple Type)
Refer to Safety Precautions on page 58.
Refer to your OMRON website for the most recent
information on applicable safety standards.
*
(E5EC/AC-800) (E5EC-B-800)
* CSA conformance evaluation by UL.
48 × 96 mm
Screw Terminal
Blocks
E5EC-800
48 × 96 mm
Push-In Plus
Terminal
Blocks
E5EC-B-800
96 × 96 mm
Screw Terminal Blocks
E5AC-800
E5EC-800/E5EC-B-800
4-digit displays
Sensor Input
Control Output 1
Auxiliary Outputs
• PF (shift) Key
• Temperature status display
• Independent heating and
cooling PID control
• Changed parameter display
Dual displays: PV/SV
E5AC-800
Control Output 2
• None
• Relay output
Universal input
• Thermocouple
• Pt
• Analog current/voltage
• Relay output
• Voltage output
(for driving SSR)
• Linear current output
<E5EC-800>
• None
• 2
<E5AC-800>
• None
• 1
• 2
• 3
<E5EC-B-800>
• 2
Indication Accuracy
• Thermocouple input:
±0.3% of PV
• Pt input: ±0.2% of PV
• Analog input: ±0.2% of FS
Sampling Period
• 50 ms
Serial Communications
• None
• RS-485
Event Inputs
<E5EC-800/E5AC-800>
• None
• 2
• 4
<E5EC-B-800>
• None
• 2
E5EC-800/E5EC-B-800/E5AC-800
(48 × 96 mm/96 × 96 mm)
Large White PV Display That’s Easier to
Read.
Easy to Use, from Model Selection to
Setup and Operation.
Models with Push-In Plus Terminal
Blocks Added to 48 × 96-mm Lineup.
• A white LCD PV display with a height of approx. 18 mm for the
E5EC/E5EC-B-800 and 25 mm for the E5AC-800 improves
visibility.
• High-speed sampling at 50 ms.
• With 48 x 96-mm Controllers, you can select between screw
terminal blocks or Push-In Plus terminal blocks to save wiring work.
• Short body with depth of only 60 mm. (Screw Terminal Blocks)
• Easy connections to a PLC with programless communications.
Use component communications to link Temperature
Controllers to each other.
Main I/O Functions
21