HIGHLY ACCURATE, LOW-PRESSURE
LABORATORY TRANSDUCER
0-0.1 to 0-50 inH2O
0-25 Pa to 0-12.5 kPa
PX653 Series
Standard
PRESSURE TRANSDUCERS
DIFFERENTIAL
Ideal
Applications:
U Clean Rooms
U HVAC
U Laboratory
Fume Hoods
SPECIFICATIONS
Excitation: 12 to 36 Vdc
Output: 1 to 5 Vdc (3 wire)
Linearity: 0.3% FS (BFSL)
Hysteresis: 0.02% FS
Repeatability: 0.05% FS
Operating Temperature:
-29 to 72°C (-20 to 160°F)
Compensated Temperature:
2 to 57°C (35 to 135°F)
Thermal Effects:
Zero: 0.015% FS/°F
Span: 0.015% rdg/°F
Proof Pressure: 15 psi
Burst Pressure: 20 psi
Static Pressure: 25 psi
Gage Type: Capacitance
Supply Current: <5 mA
Calibration Report: NIST cal at 25,
50, 75 and 100% FS; upscale and
downscale provided
Response Time: 250 ms
Wetted Parts:
Dry, clean, non-corrosive gases only
Enclosure: NEMA 2 (IP62)
Dimensions: 107 H x 117 W x 53 mm D
(4.2 x 4.6 x 2.1")
Pressure Port:
(tubing TY-316-100)
Electrical Connections: Screw terminal
Weight: 368 g (13 oz)
1
⁄4 barbed fittings
PX653-10D5V, with DP3002-E meter,
shown smaller than actual size.
To Order
inH
O Pa/kPa MODEL NO. COMPATIBLE METERS
2
0 to 0.1 0 to 25 PX653-0.1D5V DP25B-E, DP41-E, DP460-E
0 to 0.25 0 to 62 PX653-0.25D5V DP25B-E, DP41-E, DP460-E
0 to 0.50 0 to 125 PX653-0.5D5V DP25B-E, DP41-E, DP460-E
0 to 0.75 0 to 187 PX653-0.75D5V DP25B-E, DP41-E, DP460-E
0 to 1 0 to 249 PX653-01D5V
0 to 2 0 to 498 PX653-02D5V DP25B-E, DP41-E, DP460-E
0 to 3 0 to 748 PX653-03D5V DP25B-E, DP41-E, DP460-E
0 to 5 0 to 1.25 PX653-05D5V DP25B-E, DP41-E, DP460-E
0 to 10 0 to 2.49 PX653-10D5V
0 to 25 0 to 6.23 PX653-25D5V DP25B-E, DP41-E, DP460-E
0 to 50 0 to 12.5 PX653-50D5V DP25B-E, DP41-E, DP460-E
BI-DIRECTIONAL RANGES
±0.1 25 PX653-0.1BD5V DP25B-E, DP41-E, DP460-E
±0.25 62 PX653-0.25BD5V DP25B-E, DP41-E, DP460-E
±0.50 125 PX653-0.5BD5V DP25B-E, DP41-E, DP460-E
±1 249 PX653-01BD5V DP25B-E, DP41-E, DP460-E
±2.5 623 PX653-2.5BD5V DP25B-E, DP41-E, DP460-E
±5 1.25 PX653-05BD5V DP25B-E, DP41-E, DP460-E
±10 2.49 PX653-10BD5V DP25B-E, DP41-E, DP460-E
±25 6.23 PX653-25BD5V DP25B-E, DP41-E, DP460-E
±50 12.5 PX653-50BD5V DP25B-E, DP41-E, DP460-E
Comes complete with NIST traceble calibration certificate and operator’s manual.
Ordering Examples: PX653-01D5V, 0 to 1 inH2O range with 1 to 5 Vdc output.
PX653-01BD5V, ±1 inH2O range, 1 to 5 Vdc output with 0 = 3 Vdc.
Visit omega.com/px653 for Pricing and Details
RANGE
DP25B-E, DP41-E, DP3002-E
DP25B-E, DP41-E, DP3002-E
B-222
B