Omega Products PX6000C0-015A5T User Manual

DIFFUSED SEMICONDUCTOR
ELECTRICAL CONNECTION BENDIX PTIH-10-6P OR EQUIV. MATES WITH BENDIX PTS06A-10-6S OR EQUIV. (NOT SUPPLIED) ALSO AVAILABLE: 4-PIN SOLDER TERM. OR INTEGRAL 0.6 m (24") CABLE
IDENTIFIED IN THIS AREA
PX02
17.5 (0.69) WRENCH
FLATS
PXM02
18 (0.71)
HEX
PRESSURE PORT
38 DIA.
(1.51) MAX.
60 MAX.
(2.35)
6.4 ±0.25
(0.25 ±0.01)
FLATS
TRANSDUCER
STANDARD AND METRIC MODELS
PRESSURE
PX6000/PXM6000 Series
0-5 Vdc Output 0-15 to 0-300 psi-Standard Models 0-1 to 0-16 bar-Metric Models
All Ranges
$
560
Standard
High ReliabilityLong-Term StabilityAll Stainless Steel CaseVacuum Range Available
OMEGA’s PX6000/PXM6000 pressure transducers fit easily into your applications. This low-cost transducer is small and light, and mounting requires no bulky structures.You select from 3 electrical terminations and 6 pressure fittings. The sensor is a small [about 2.5 mm (0.1")] square silicon chip with 4 diffused strain gages, mounted in the stainless steel case. Laser-trimmed resistors provide temperature compensation and adjust zero balance and span.
The PX6000 Series uses solid state media isolation for improved reliability. Thin films of chemically inert materials are deposited or grown on the chip surface to provide electrical isolation between the sensor and the pressure medium. The sensor is less sensitive to vibration and more dependable in high-shock environments because the films add no significant mass. Corrosion resistance is outstanding, and the isolation will remain effective because there is no gel or oil column to deteriorate.
SPECIFICATIONS
Excitation: 12 to 40 Vdc unregulated Output: 0 to 5 Vdc ±0.1Vdc
adjustable ±10% FSO
Input Current:
15 mA max with no load
Output Resistance: Less than 200 Zero Balance: 0V ±0.1 Vdc
Adjustable ±5% FSO
Dielectric Isolation Resistance:
100 MΩ minimum at 45 Vdc applied between the case or a conductive medium and the bridge circuit
Sensing Element: 4-active-arm bridge using a micro-machined diffused silicon diaphragm sensor, thin-film media and dielectric isolation barriers
Temperature Sensor: Output resistance @ 24°C (75°F) 900 to 1500
Temperature Coefficient:
8% min, 10% max per 55.5°C (100°F) Accuracy: Combined linearity,
hysteresis and repeatability ±0.25% FSO for all ranges
Operational Temp Range:
-54 to 121°C (-65 to 250°F)
Compensated Temp Range:
-18 to 82°C (0 to 180°F)
DIN Pin Wire Code 1 A RED = + Input 3 B YEL = + Output
C BL = Common
2 D WT = Common
E = Temp. Sensor F = Temp. Sensor Shield = Case Ground
Dimensions: mm (in)
B-138
PX6000C1-100G5T, $560, shown actual size.
Thermal Effects:
Span: ±0.03% FSO/°F (0.054%/ºC) Zero: ±0.03% FSO/°F (0.054%/ºC)
Vibration Sensitivity: At 20 g peak
sinusoidal vibration from 10 Hz to 2000 Hz ( exceed 0.04% FSO/g for 15 psi range to
0.005% FSO/g for 100 psi and above Natural Frequency: Greater than
35 kHz for 7 bar (100 psi) and above Shock: 100 g, 11 ms half sine wave
without damage
Proof Pressure:
2 times rated pressure will not cause changes in performance beyond the specified tolerances
Burst Pressure: 3 times rated pressure for pressure ranges below 14 bar (200 psi), or 2.5 times rated pressure for pressure ranges above 200 psi will not cause rupture of the pressure sensor
Wetted Parts: 316 stainless steel, silicon, Pyrex
Electrical Connection: See Custom Configurations, next page
Pressure Port: See Custom Configurations, next page
Weight: 170 g (6 oz) typical Mating Connector (Style 1):
PTS06A-10-6S (sold separately)
1
2" D.A.), the output shall not
®
glass, epoxy, Kovar
®
PRESSURE TRANSDUCERS
VOLTAGE OUTPUT
B
DIFFUSED SEMICONDUCTOR TRANSDUCER
STANDARD CUSTOM CONFIGURATIONS
STANDARD CUSTOM CONFIGURATIONS
PX6000 PRESSURE ELECTRICAL RANGE SERIES PORT CONNECTION (psi) UNITS OUTPUT OPTIONS
A = B = 1⁄8-27 NPT female C = 1⁄4-18 NPT male D = 1⁄4-18 NPT female L = MS33656-4 male M = MS33649-4 female
[ 1 ] [ 2 ] [ 3 ] [ 4 ] [ 5 ] [ 6 ]
1
8-27 NPT male
30* 015 020 050 100 200 300
VAC G,A G,A G,A G,A G,A G,A
5T = 0 to 5 Vdc output
$560 all ranges
* Referenced to atmospheric pressure,
0 = 0.6 m (2') cable (std)
+$4.50/ft over 0.6 m (2')
30 Vac range is 30 to 0 inHg vacuum, all other ranges are psi.
1 = PTIH-10-6P connector
(or equal, no charge). Mating connector (sold separately), order
PTS06A-10-6S $47.
3 = 4-pin eyelet header (no charge);
(no temp sensor)
6 = mini DIN connector (no charge);
(no temp sensor)
To order a custom configuration:
1. Select a pressure port
2. Select electrical connection
3. Select a pressure range
4. Select pressure units
5. Select output
6. Select options and agency approvals
CAL11 = 11-point NIST
( )FT = Extra length of
ating
M Connector PTS06A-10-6S $47
calibration
+$250
cable, $4.50/ft over 0.6 m (2')
Ordering Examples: PX6000M1-100G5T, 100 psi vented gage pressure transducer with MS33649-4, female pressure connection, PTIH-10-6P, electrical connector and 0 to 5 V output, $560. PTS06A-10-6S, mating connector (sold separately), $47. PX6000A0-30VAC5T-25FT, 30 to 0 inHg vacuum transducer with a (30 inHg vacuum = full scale output) 0 to 5 output, and 7.6 m (25') cable, $560 + 23 (2.5) = $617.50. PX6000L1-015A5T, 15 psi absolute pressure transducer with MS33656-4, male pressure connection, PTIH-10-6P, electrical connector and 0 to 5 Vdc output, $560. PTS06A-10-6S, mating connector (sold separately), $47.
1
-27 NPT male pressure connection, a reverse-acting
8
G1⁄4 Pressure Snubbers: $12.75
PS-4G-MG = Gas PS-4E-MG = Lt Oil PS-4D-MG = Dense
METRIC CUSTOM CONFIGURATIONS
PXM6000 PRESSURE ELECTRICAL RANGE SERIES PORT CONNECTION (BAR) UNITS OUTPUT OPTIONS
[ 1 ] [ 2 ] [ 3 ] [ 4 ] [ 5 ] [ 6 ]
MA = G
1
8B Male +$20
MB = G1⁄8B Female no charge MC = G1⁄4B Male +$20 MD = G1⁄4B Female no charge
0 = 0.6 m (2') cable (std)
$15/m over 0.6 m (2')
1.0
1.6
4.0
6.0 10 16
G,A G,A G,A G,A G,A G,A
5T= 0 to 5 Vdc output
$560 all ranges
CAL11 = 11-point calibration
certificate
( )m = Optional cable
length in meters, $15/m over
0.6 m (2')
1 = PTIH-10-6P connector
(or equal, no charge)
3 = 4-pin eyelet (no charge)
(no temp sensor)
6 = mini DIN connector (no
charge) (no temp sensor)
To order a custom configuration:
1. Select a pressure port
2. Select electrical connection
3. Select a pressure range
4. Select pressure units – absolute, gage
or sealed gage
See page B-12 for additional options including extended compensated temperatures.
Ordering Examples: PXM6000MB0-010BARG5T, 10 bar gage pressure transducer with G termination, 0 to 5V output, $560.
PXM6000MD1-010BARA5T, 10 bar absolute pressure transducer with G PTS06A-10-6S, mating connector (sold separately), $26.50.
1
B female connection, 0 to 5V output, and twist-lock connector, $560.
4
5. Select output
6. Select options and agency approvals
1
8B female connection and 0.6 m (2') cable
B-139
Liquid
Loading...
+ 2 hidden pages