RANGEABLE WET/WET DIFFERENTIAL 
PRESSURE TRANSMITTER
LCD WITH BACKLIGHT
Bi-Directional Ranges:  
±4 inH20 to ±200 inH20
[±10 to ±500 mbar (hPa)] 
Unidirectional Ranges: 
0 to 4 inH
0 to 0 to 400 inH20
2
[10 to 1000 mbar (hPa)] 
4 to 20 mA output
PX5200 Series
Optional
 Compact Size  
 NEMA 4X (IP65)
Environmental Rating
 Backlit LCD for Easy 
Reading
 Display Can Be Scaled to 
Any Units
 Display Rotates in 90° 
Increments to Fit Location
 Stainless Steel, FKM, and 
Ceramic Wetted Parts
 Flow measurement 
Totalization/Square Root 
Extraction Function
 Quick Ranging with 
Internal Push-Buttons
 Scale to Display in Any 
Engineering Units
 MIN/MAX and HOLD 
Functions
 Loop Check Function 
to Check Circuit
 Program Lock 
Function 
The new OMEGA® PX5200 is a 
compact wet/wet differential pressure 
dP transmitter, ideal for flow and 
tank level applications where 
reliable, low dP measurements are 
required. Equipped with a solid state 
sensor and a 316 Stainless Steel 
isolating diaphragm, the PX5200 
can monitor a wide variety of wet or 
dry media. Available in unidirectional 
ranges from 0 - 4 to 0 - 400 inH2O 
and bi-directional ranges up to 
PX5200
±200 inH2O, the PX5200 operates 
on line (static) pressures up  
to 300 psi.
A rugged aluminum NEMA 4X 
(IP65) enclosure measures only 
65 mm (2.56") in diameter and 
incorporates a backlit LCD display 
for local reading.
The output is a two-wire 
configurable 4 to 20 mA signal that 
can be adjusted to re-range the 
transmitter or “tare” unwanted fluid 
head preloads. In addition, this 
instrument offers flow measurement/
B-1
PRESSURE TRANSDUCERS
B
PX5200
square root extraction, where the 
indicated flow rate and analog signal 
can be displayed. Rangeability for 
zero and span are from -10 to  
110% FS URL (Upper Range Limit). 
This means a 20 inH2O transducer 
can have the zero set between 
-2 inH2O to FS 22 inH2O. Span  
can be set over that range also.  
For example zero could be set for  
2 inH2O and 22 inH2O maximum  
so the output would be 4 mA at  
2 inH2O, midpoint 12 mA would be  
12 inH2O and 20 mA would be  
22 inH2O.
 

Dimension Drawings
Dimensions in inches
4 x ø .22 
4xØ.22
Panel Mounting Holes 
Panel Mounting Holes
Bracket t = 0.08
Brackett=.08
114 (4.49)
3.62
91.9 (3.62)
73.9 (2.91)
2.91
57.9 (2.28)
2.28
4.49
Drain Outlet
SPECIFICATIONS
Output: 4 to 20 mAdc (2-wire)  
Supply Voltage: 12 to 32 Vdc 
Vmin=12V+(0.022Ax loop res) 
Insulation Resistance: 50 Vdc 
(>100 MΩ) 
Rangeability/Adjustments: 
 Zero: -10% to 110% FS 
 Span: -10% to 110% FS 
Accuracy: ±0.5% FS URL (upper range 
limit) @23°C includes linearity, hysteresis 
and repeatability
Note: Accuracy and output resolution based 
upon FS URL (upper range limit) value.
Stability: ±0.25% FS/year 
Response Time: 100 ms (adjustable) 
Output Resolution: 0.1% FS URL 
Display: 4-digit, 10 mm LCD with 
LED backlight 
Display Accuracy: ±0.5% FS URL 
(upper range limit) + 1 digit 
Storage Temperature: -15 to 65°C 
(5 to 150°F) 
Operating Temperature: -10 to 60°C 
(14 to 140°F) 
Compensated Temperature: -10 to 60°C 
(14 to 140°F)
Temperature Effects (Over Comp 
Range): ±0.03% FS URL /°C (from 23°C 
reference) 
Static (Line) Pressure (All Ranges): 
 Proof: 300 psi  
 Burst: 800 psi
Static (Line) Pressure Effects:
 ≥20 inH2O, ±8 inH2O: ±0.03% FS/ 
100 psi
 8 inH2O, ±4 inH2O: ±0.07% FS/ 
100 psi
 4 inH2O: ±0.15% FS/100 psi
Single Side (Differential) Limits: 
 ≤8 inH2O, ±4 inH2O: 
 Proof: 30 psid 
 Burst: 130 psi
≥20 inH2O, ±8 inH2O:  
 Proof: 100 psid  
 Burst: 130 psi
Vibration: 5 g 150 Hz 
Shock: 10 g 16 ms 
Pressure Connection: ¹⁄₄ NPT female 
Electrical Termination: ¹⁄₂ NPT female 
conduit fitting 
Environmental Rating: 
NEMA 4X (IP65) 
CE Compliance: EN 613261 1997, 
A1/1998, A2/2001 heavy industrial 
Media: Fluids and gasses compatible 
with 316SS, FKM, and alumina ceramic
Weight: Approx 454 g (1 lb)
PX5200
inH2O
5.12
4.72
130 (5.12)
119.8 (4.72)
17.5 
(0.69)
.69
50 (1.97)
1.97
59.9 (2.36)
2.36
Electrical Connection  
1/2 FNPT conduit 
Electrical Connection 
1/2FNPTconduitconnection
connection
Equalizing Valve
25 (1.0)
1.0
High Pressure Port 
Low Pressure Port 
1/4 NPT female
1/4NPT female
Ø2.56
ø 65 (2.56)
36 (1.42)
1.42
.82
20.8 (0.82)
10.6 (0.42)
.42
2.07
52.5 (2.07)
2 x ø 0.06 
2xØ.06
Drain
Drain
Dimensions: mm (inch)
 To Order Visit omega.com/px5200 for Pricing and Details
 SPAN AND ZERO ADJUSTABLE -10% to +110% FS URL 
     RANGE 
  inH
O  mb (hPa)  MODEL NO.
2
 BI-DIRECTIONAL RANGES
   ±4 inH 
   ±8 inH 
   ±20 inH 
  ±40 inH 
   ±80 inH 
   ±200 inH
UNI-DIRECTIONAL RANGES
   0 to 4 inH 
   0 to 8 inH 
   0 to 20 inH 
   0 to 40 inH 
   0 to 80 inH 
   0 to 200 inH
  0 to 400 inH
OPTION (ADD AS SUFFIX TO MODEL NO.)
O  ±10 mbar  PX5200-004WBDI
2
O  ±20 mbar  PX5200-008WBDI
2
O  ±50 mbar  PX5200-020WBDI
2
O  ±100 mbar  PX5200-040WBDI
2
O  ±200 mbar  PX5200-080WBDI
2
O  ±500 mbar  PX5200-200WBDI
2
O  0 to 10 mbar  PX5200-004WUDI
2
O  0 to 20 mbar  PX5200-008WUDI
2
O  0 to 50 mbar  PX5200-020WUDI
2
O  0 to 100 mbar  PX5200-040WUDI
2
O  0 to 200 mbar  PX5200-080WUDI
2
O  0 to 500 mbar  PX5200-200WUDI
2
O  0 to 1000 mbar  PX5200-400WUDI
2
  -XRH  9-point NIST traceable calibration, must specify at time of order 
Comes complete with mounting bracket and operator’s manual. 
Ordering Examples: PX5200-020WUDI, 0 to 20 inH2O unidirectional differential pressure 
rangeable transmitter, 4 to 20 mA output. 
PX5200-004WBDI, ±4 inH2O bidirectional differential pressure rangeable transmitter, 
4 to 20 mA output (4 mA = -4 inH2O, 20 mA = + 4 inH2O), ¹⁄₂ NPT female.
B-2