Omega Products PX5200-008WBDI User Manual

RANGEABLE WET/WET DIFFERENTIAL PRESSURE TRANSMITTER
LCD WITH BACKLIGHT
Bi-Directional Ranges: ±4 inH20 to ±200 inH20
[±10 to ±500 mbar (hPa)] Unidirectional Ranges:
0 to 4 inH
0 to 0 to 400 inH20
2
[10 to 1000 mbar (hPa)] 4 to 20 mA output
PX5200 Series
Optional
Compact Size NEMA 4X (IP65)
Environmental Rating
Backlit LCD for Easy
Reading
Display Can Be Scaled to
Any Units
Display Rotates in 90°
Increments to Fit Location
Stainless Steel, FKM, and
Ceramic Wetted Parts
Flow measurement
Totalization/Square Root Extraction Function
Quick Ranging with
Internal Push-Buttons
Scale to Display in Any
Engineering Units
MIN/MAX and HOLD
Functions
Loop Check Function
to Check Circuit
Program Lock
Function
The new OMEGA® PX5200 is a compact wet/wet differential pressure dP transmitter, ideal for flow and tank level applications where reliable, low dP measurements are required. Equipped with a solid state sensor and a 316 Stainless Steel isolating diaphragm, the PX5200 can monitor a wide variety of wet or dry media. Available in unidirectional ranges from 0 - 4 to 0 - 400 inH2O and bi-directional ranges up to
PX5200
±200 inH2O, the PX5200 operates on line (static) pressures up to 300 psi.
A rugged aluminum NEMA 4X (IP65) enclosure measures only 65 mm (2.56") in diameter and incorporates a backlit LCD display for local reading.
The output is a two-wire configurable 4 to 20 mA signal that can be adjusted to re-range the transmitter or “tare” unwanted fluid head preloads. In addition, this instrument offers flow measurement/
B-1
PRESSURE TRANSDUCERS
B
PX5200
square root extraction, where the indicated flow rate and analog signal can be displayed. Rangeability for zero and span are from -10 to 110% FS URL (Upper Range Limit). This means a 20 inH2O transducer can have the zero set between
-2 inH2O to FS 22 inH2O. Span can be set over that range also. For example zero could be set for 2 inH2O and 22 inH2O maximum so the output would be 4 mA at 2 inH2O, midpoint 12 mA would be 12 inH2O and 20 mA would be 22 inH2O.
Dimension Drawings
Dimensions in inches
4 x ø .22
4xØ.22
Panel Mounting Holes
Panel Mounting Holes
Bracket t = 0.08
Brackett=.08
114 (4.49)
3.62
91.9 (3.62)
73.9 (2.91)
2.91
57.9 (2.28)
2.28
4.49
Drain Outlet
SPECIFICATIONS
Output: 4 to 20 mAdc (2-wire) Supply Voltage: 12 to 32 Vdc
Vmin=12V+(0.022Ax loop res) Insulation Resistance: 50 Vdc
(>100 MΩ) Rangeability/Adjustments:
Zero: -10% to 110% FS Span: -10% to 110% FS
Accuracy: ±0.5% FS URL (upper range limit) @23°C includes linearity, hysteresis and repeatability
Note: Accuracy and output resolution based upon FS URL (upper range limit) value.
Stability: ±0.25% FS/year Response Time: 100 ms (adjustable) Output Resolution: 0.1% FS URL Display: 4-digit, 10 mm LCD with
LED backlight Display Accuracy: ±0.5% FS URL
(upper range limit) + 1 digit Storage Temperature: -15 to 65°C
(5 to 150°F) Operating Temperature: -10 to 60°C
(14 to 140°F) Compensated Temperature: -10 to 60°C
(14 to 140°F)
Temperature Effects (Over Comp Range): ±0.03% FS URL /°C (from 23°C
reference) Static (Line) Pressure (All Ranges):
Proof: 300 psi Burst: 800 psi
Static (Line) Pressure Effects:
20 inH2O, ±8 inH2O: ±0.03% FS/
100 psi
8 inH2O, ±4 inH2O: ±0.07% FS/
100 psi
4 inH2O: ±0.15% FS/100 psi
Single Side (Differential) Limits: ≤8 inH2O, ±4 inH2O: Proof: 30 psid
Burst: 130 psi
20 inH2O, ±8 inH2O: Proof: 100 psid Burst: 130 psi
Vibration: 5 g 150 Hz Shock: 10 g 16 ms Pressure Connection: ¹⁄₄ NPT female Electrical Termination: ¹⁄₂ NPT female
conduit fitting Environmental Rating:
NEMA 4X (IP65) CE Compliance: EN 613261 1997,
A1/1998, A2/2001 heavy industrial Media: Fluids and gasses compatible
with 316SS, FKM, and alumina ceramic
Weight: Approx 454 g (1 lb)
PX5200
inH2O
5.12
4.72
130 (5.12)
119.8 (4.72)
17.5
(0.69)
.69
50 (1.97)
1.97
59.9 (2.36)
2.36
Electrical Connection 1/2 FNPT conduit
Electrical Connection 1/2FNPTconduitconnection
connection
Equalizing Valve
25 (1.0)
1.0
High Pressure Port Low Pressure Port 1/4 NPT female
1/4NPT female
Ø2.56
ø 65 (2.56)
36 (1.42)
1.42
.82
20.8 (0.82)
10.6 (0.42)
.42
2.07
52.5 (2.07)
2 x ø 0.06
2xØ.06
Drain
Drain
Dimensions: mm (inch)
To Order Visit omega.com/px5200 for Pricing and Details
SPAN AND ZERO ADJUSTABLE -10% to +110% FS URL RANGE inH
O mb (hPa) MODEL NO.
2
BI-DIRECTIONAL RANGES
±4 inH ±8 inH ±20 inH ±40 inH ±80 inH ±200 inH
UNI-DIRECTIONAL RANGES
0 to 4 inH 0 to 8 inH 0 to 20 inH 0 to 40 inH 0 to 80 inH 0 to 200 inH
0 to 400 inH
OPTION (ADD AS SUFFIX TO MODEL NO.)
O ±10 mbar PX5200-004WBDI
2
O ±20 mbar PX5200-008WBDI
2
O ±50 mbar PX5200-020WBDI
2
O ±100 mbar PX5200-040WBDI
2
O ±200 mbar PX5200-080WBDI
2
O ±500 mbar PX5200-200WBDI
2
O 0 to 10 mbar PX5200-004WUDI
2
O 0 to 20 mbar PX5200-008WUDI
2
O 0 to 50 mbar PX5200-020WUDI
2
O 0 to 100 mbar PX5200-040WUDI
2
O 0 to 200 mbar PX5200-080WUDI
2
O 0 to 500 mbar PX5200-200WUDI
2
O 0 to 1000 mbar PX5200-400WUDI
2
-XRH 9-point NIST traceable calibration, must specify at time of order
Comes complete with mounting bracket and operator’s manual. Ordering Examples: PX5200-020WUDI, 0 to 20 inH2O unidirectional differential pressure
rangeable transmitter, 4 to 20 mA output. PX5200-004WBDI, ±4 inH2O bidirectional differential pressure rangeable transmitter,
4 to 20 mA output (4 mA = -4 inH2O, 20 mA = + 4 inH2O), ¹⁄₂ NPT female.
B-2