Omega Products CNi3222 User Manual

Page 1
9‑segment display
1
32 DIN Temperature, Process
and Strain PID Controllers
CNi32 Series
U High Accuracy: ±0.03%
Reading, 0.5°C (±0.9°F)
1
U First
with Totally Programmable Color Displays Standard
U User-Friendly,
Simple to Configure
U Free Software,
ActiveX Controls
U Full Autotune PID Control U Universal Inputs:
Thermocouple RTD, Process Voltage/ Current, Strain
U First
Offering Both RS232 and RS485 Serial Communications in 1 Instrument (Optional)
U First 1⁄32 DIN Instrument
with Built-in Excitation, 24 Vdc Standard
U Temperature Stability
±0.04°C/°C RTD and ±0.05°C/°C TC @ 25°C (77°F)
U NEMA 4 (IP65) Front Bezel U First 1⁄32 DIN Instrument
with Analog Output Selectable as a Control Output or as Retransmission of Process Variable
U 2 Control or Alarm
Outputs Optional: DC Pulse, Solid State Relays, Mechanical Relays, Analog Voltage and Current
U Front Removable and
Plug Connectors
32 DIN Instrument
1
32 DIN Instrument
The OMEGA® CNi32 is the iSeries controller in the extremely compact and increasingly popular 1⁄32 DIN size (22.5 x 45 mm cutout). The CNi32 is the most sophisticated and accurate instrument available in the small
1
32 DIN package, yet is still easy
to configure.
The CNi32 handles more thermocouple, RTD, process voltage and current inputs than any other 1⁄32 DIN controller.
The CNi32 is the first 1⁄32 DIN controller with built‑in excitation for transmitters or other devices, 24 Vdc @ 25 mA.
The CNiS32 has built‑in excitation for bridge transducers, 5 Vdc @ 40 mA or 10 Vdc @ 60 mA. When communications options are installed, external excitation may be used and ratiometric operation maintained by connecting the external excitation to the sense leads. Both 4‑ or 6‑wire bridge configurations are supported for internal or external excitation. Non‑ratiometric operation is supported for voltage and current transducers
The iSeries displays feature unique 9‑segment LED characters, which greatly improves alphanumeric representations. The 7‑segment LED characters found on most instruments are adequate for presenting numbers, but not letters.
Words are easier to read with the unique 9‑segment LED characters on the iSeries, which makes operating and programming simpler and easier.
Panel punches
available, visit
omega.com/
panelpunches
CNi3233, smaller than actual size.
and is also valuable in measuring offset and millivolt output of bridge devices during manufacturing and calibration. This model also features 10‑point linearization which allows the user to linearize the signal input from extremely nonlinear transducers of all kinds.
The CNi32 introduces a number of unique features not yet found on any
1
other
32 DIN instrument. The CNi32 is the first 1⁄32 DIN controller with a totally programmable display that can change color between GREEN,
AMBER, and RED at any setpoint
or alarm point.The unique 9‑segment LED characters greatly improves alphanumeric representations.
The CNi32 is the first 1⁄32 DIN controller offering 2 SPDT Form C relays, instead of the single throw relays on typical 1⁄32 DIN controllers.
The CNi32 is the first to offer both RS232 and RS422/485 serial communications in 1 instrument (C24 option). Both ASCII protocol and modbus protocol are selectable from the menu.
7‑segment display
9‑segment display
P-19P-19
Page 2
DPi32-B-COVER front
25.4 (1.00)
panel button cover supplied with each
unit, standard.
CNi3233, shown smaller than actual size.
22.50 +0.61/-0 (0.89)
PANEL CUTOUT
Dimensions: mm (inch)
45.00 +0.61/-0.00 (1.89)
PANEL THICKNESS
1
/32 DIN
Options
Suffix Ordering Description
-AL Limit alarm version
-SM Simplified menu (on/
Network Options
-C24 Isolated RS232 and
-EIS-2B
Power Supply
-DC 12 to 36 Vac/dc,
Factory Setup
-FS Factory setup and
-FS(RTD-1N) Factory scaled for
-FS(RTD-2N) Factory scaled for
Software (Requires Network Option) OPC-SERVER OPC server/driver
LICENSE software license
1
Excitation not available with “-DC”, “-C24” or
-C4EI” options.
2
“-AL” option not available on models with
analog (0 to 10V/0 to 20 mA) output.
3
“-SM” option not available on CNiS strain/
process input models.
(simplified menu, alarms only, no PID control)
off control or alarms, no PID)
RS485/422, 300 to
19.2 Kb
2
3
1
Industrial iServer Microserver™, serves 32 devices
1
24 Vac
configuration
MIL‑T‑7990B nickel RTD input, 0 to 200°C (32 to 392°F)
MIL‑T‑7990B nickel RTD input, ‑40 to 300°C (‑40 to 572°F)
CNi3244, shown smaller than actual size.
48.0
48.0 (1.89)
(1.89)
FRONT VIEW
6.4 MAX
0.6 MIN
48.0
48.0
48.0 (1.89)
(1.89)
(1.89)
REAR VIEW
25.4 (1.00)
25.4 (1.00)
To Order Visit omega.com/cni32_series for Pricing and Details
Model No. Output 1 Output 2 Temperature/Pressure Input CNi3222 0.5 A SSR 0.5 A SSR CNi3223 0.5 A SSR Relay CNi3224 0.5 A SSR DC pulse CNi3233 Relay Relay CNi3242 DC pulse 0.5 A SSR CNi3243 DC pulse Relay CNi3244 DC pulse DC pulse CNi3252 Analog 0.5 A SSR CNi3253 Analog Relay CNi3254 Analog DC pulse Strain/Process Input CNiS3222 0.5 A SSR 0.5 A SSR CNiS3223 0.5 A SSR Relay CNiS3224 0.5 A SSR DC pulse CNiS3233 Relay Relay CNiS3234 Relay DC pulse CNiS3242 DC pulse 0.5 A SSR CNiS3243 DC pulse Relay CNiS3244 DC pulse DC pulse CNiS3252 Analog 0.5 A SSR CNiS3253 Analog Relay CNiS3254 Analog DC pulse
Accessory
Model No. Description DPP-1
Comes complete with DPi32-B-COVER and operator’s manual. Ordering Examples: CNi3222-C24,
control and serial communications, both RS232 and RS485. CNiS322-AL,
1
32 DIN panel punch
1
DIN PID controller with 2 solid-state relays for PID
32
1
DIN strain/process controller, limit alarm version with SSR output.
32
P-20
P-20
25.4 (1.00)
P
P
Page 3
Common Specifications
(All
i/8, i/16, i/32 DIN)
Universal Temperature and Process Input (DPi/CNi Models)
Accuracy: ±0.5°C temp; 0.03% rdg Resolution: 1°/0.1°; 10 µV process Temperature Stability: RTD: 0.04°C/°C TC @ 25°C (77°F): 0.05°C/°C Cold Junction Compensation Process: 50 ppm/°C NMRR: 60 dB CMRR: 120 dB A/D Conversion: Dual slope Reading Rate: 3 samples/s Digital Filter: Programmable Display: 4‑digit 9‑segment LED
10.2 mm (0.40"); i32, i16, i16D, i8DV 21 mm (0.83"); i8 10.2 mm (0.40") and 21 mm (0.83"); i8DH RED, GREEN, and AMBER programmable colors for process variable, setpoint and temperature units Input Types: Thermocouple, RTD, analog voltage, analog current Thermocouple Lead Resistance: 100 Ω max
Thermocouple Types (ITS 90):
J, K, T, E, R, S, B, C, N, L (J DIN) RTD Input (ITS 68): 100/500/1000 Ω Pt sensor, 2‑, 3‑ or 4‑wire; 0.00385 or
0.00392 curve Voltage Input: 0 to 100 mV, 0 to 1V, 0 to 10 Vdc Input Impedance: 10 MΩ for 100 mV 1 MΩ for 1 or 10 Vdc
Current Input: 0 to 20 mA (5 Ω load) Configuration: Single‑ended Polarity: Unipolar Step Response: 0.7 sec for 99.9% Decimal Selection:
Temperature: None, 0.1 Process: None, 0.1, 0.01 or 0.001
Setpoint Adjustment:
‑1999 to 9999 counts Span Adjustment:
0.001 to 9999 counts
Offset Adjustment: ‑1999 to 9999
Excitation (Not Included with Communication): 24 Vdc @ 25 mA
(not available for low‑power option)
Universal Strain and Process Input (DPiS/CNiS Models)
Accuracy: 0.03% reading Resolution: 10/1µV Temperature Stability: 50 ppm/°C NMRR: 60 dB CMRR: 120 dB A/D Conversion: Dual slope Reading Rate: 3 samples/s Digital Filter: Programmable Input Types: Analog voltage and current Voltage Input: 0 to 100 mVdc,
‑100 mVdc to 1 Vdc, 0 to 10 Vdc Input Impedance: 10 MΩ for 100 mV; 1 MΩ for 1V or 10 Vdc
Current Input: 0 to 20 mA (5 Ω load) Linearization Points: Up to 10 Configuration: Single‑ended Polarity: Unipolar Step Response: 0.7 sec for 99.9%
Decimal Selection: None, 0.1, 0.01
or 0.001 Setpoint Adjustment: ‑1999 to 9999 counts
Span Adjustment: 0.001 to 9999 counts Offset Adjustment: ‑1999 to 9999 Excitation (Optional In Place Of Communication): 5 Vdc @ 40 mA;
10 Vdc @ 60 mA
Control
Action: Reverse (heat) or direct (cool) Modes: Time and amplitude proportional
control; selectable manual or auto PID, proportional, proportional with integral, proportional with derivative and anti‑reset Windup, and on/off
Rate: 0 to 399.9 s Reset: 0 to 3999 s Cycle Time: 1 to 199 s; set to 0 for on/off Gain: 0.5 to 100% of span; setpoints 1 or 2 Damping: 0000 to 0008 Soak: 00.00 to 99.59 (HH:MM), or OFF Ramp to Setpoint:
00.00 to 99.59 (HH:MM), or OFF Auto Tune: Operator initiated from front panel
Control Output 1 and 2
Relay: 250 Vac or 30 Vdc @ 3 A (resistive
load); configurable for on/off, PID and ramp and soak Output 1: SPDT, can be configured as alarm 1 output Output 2: SPDT, can be configured as alarm 2 output SSR: 20 to 265 Vac @ 0.05 to 0.5 A (resistive load); continuous
DC Pulse: Non‑isolated; 10 Vdc @ 20 mA Analog Output (Output 1 Only):
Non‑isolated, proportional 0 to 10 Vdc or 0 to 20 mA; 500 Ω max
Network and Communications
Ethernet: Standards compliance
IEEE 802.3 10 Base‑T Supported Protocols: TCP/IP, ARP, HTTPGET RS232/RS422/RS485: Selectable from menu; both ASCII and MODBUS protocol selectable from menu; p 300 to 19.2 Kb; complete programmable setup capability; program to transmit current display, alarm status, min/max, actual measured input value and status
RS485: Addressable from 0 to 199 Connection: Screw terminals
rogrammable
Alarm 1 and 2 (Programmable)
Type: Same as output 1 and 2 Operation: High/low, above/below,
band, latch/unlatch, normally open/normally closed and process/deviation; front panel configurations
Analog Output (Programmable):
Non‑isolated, retransmission 0 to 10 Vdc or 0 to 20 mA, 500 Ω max (output 1 only); accuracy is ± 1% of FS when following conditions are satisfied: input is not scaled below 1% of input FS, analog output is not scaled below 3% of output FS
General
Power: 90 to 240 Vac ±10%, 50 to 400 Hz*,
110 to 375 Vdc, equivalent voltage Low Voltage Power Option: 24 Vac
12 to 36 Vdc for i/8, i/16, 1/32; 20 to 36 Vdc for CNi8DH, CNi8DV, CNi16D from qualified safety approved source
**,
Isolation
Power to Input/Output: 2300 Vac
per 1 minute test For Low Voltage Power Option: 1500 Vac per 1 minute test Power to Relay/SSR Output: 2300 Vac per 1 minute test Relay/SSR to Relay/SSR Output: 2300 Vac per 1 minute test RS232/485 to Input/Output: 500 Vac per 1 minute test Environmental Conditions: All Models: 0 to 55°C (32 to 131°F) 90% RH non‑condensing CNi8DV, CNi8DH, CNi16D: 0 to 50°C (32 to 122°F), 90% RH non‑condensing (for UL only) Protection: CNi32, CNi16, CNi16D, CNi8C:
NEMA 4X/Type 4 (IP65) front bezel CNi8, CNi8DH, CNi8DV: NEMA 1/Type 1 front bezel Approvals: UL, C‑UL, CE per EN61010‑ 1:2001
Dimensions i/8 Series: 48 H x 96 W x 127 mm D
(1.89 x 3.78 x 5") i/16 Series: 48 H x 48 W x 127 mm D (1.89 x 1.89 x 5") i/32 Series: 25.4 H x 48 W x 127 mm D (1.0 x 1.89 x 5")
Panel Cutout i/8 Series: 45 H x 92 mm W
(1.772 x 3.622"), i/16 Series: 45 mm (1.772") square,
1
DIN
16
i/32 Series: 22.5 H x 45 mm W (0.886 x 1.772"),
Weight i/8 Series: 295 g (0.65 lb) i/16 Series: 159 g (0.35 lb) i/32 Series: 127 g (0.28 lb)
No CE compliance above 60 Hz.
* ** Units can be powered safely with 24 Vac
power, but no certification for CE/UL are claimed.
1
8
1
32
DIN
DIN
at any
setpoint
PATENTED
Totally Programmable Color Displays
P
P
P-21
P-21
Loading...