Omega Products CN9-SW User Manual

OMEGA
CARE
SM
Extended Warranty Program
PID AUTOTUNE TEMPERATURE/ PROCESS CONTROLLERS
1
16 DIN
CN9300 Series
$
180
Basic Unit
U 3-Year Warranty U 4-Digit Display U 5 Alarm Configurations U Single Ramp and Soak U PID Heat-Cool Control U NEMA-4 (IP66) Faceplate U Sleeve Mounting U Security Lockouts
Optional:
U RS-232 or RS-485
Communications
U Communications
Software: CN9-SW
U Low Voltage Power
CN9500 Series
$
169
Basic Unit
The new 1⁄32 DIN CN9500,
1
16 DIN CN9300 Single Display and1⁄16 DIN CN9400 Dual Display controllers follow the OMEGA tradition of innovative design. Building on the success of the CN132 and CN9000A series, the new models include several new features, the most important being the option of a low cost serial communicating system with easy to use Windows-based software.
1
16 DIN
CN9400 Series
$
Basic Unit
1
32 DIN
The CN9-SW series software bridges the gap between the “stand alone” system and full SCADA of Fieldbus control networks by providing a facility for remote supervision of up to 32 instruments using MODBUS protocol. It requires only a modest investment and can be operated by anyone with a medium specification PC or laptop that can be run with Windows 95 or Windows NT.
199
All units shown slightly larger than actual size
D-157
Application: Multiple CN9500 Series Controllers set up with the CN9-SW Software ($159), see page D-161.
Specifications
Power: 100 to 240 Vac, ±10%,
50 to 60 Hz, 4 VA; Optional 12 or 24 Vac/dc, ±20%, 50 to 60 Hz, 4 VA Polarity is not required. The controllers are fitted with an internal 250 mA time lag fuse.
Display: 4-digit LED, 10 mm (0.4"), high brightness green display
-199 to 9999 counts
Display Range:
(hi-res mode -199.9 to 999.9) Range: Sensor limited 2000°C/3500°F;
-99.9 to 999.9° in 0.1° resolution
Display Indicators:
Process temperature (PV), Setpoint (SP), LED output indicators-flashing Output 1 (SP1 square), green; Output 2 (SP2 round), red; error messages, Function/Option mnemonics
Thermocouple Cold Junction Compensation Rejection:
20:1 (0.05°/°C) typical
Thermocouple External Resistance:
100 max
Thermocouple: 9 types Standards: IPTS/68/DIN43710
RTD Input: Pt100 2-wire (.00385)
Linear Process Inputs:
mV range: 0 to 50 mV (1 ohm shunt resistor supplied for mA inputs)
Calibration Accuracy:
±0.25% of Full Scale ±1°C
Sampling Frequency:
Input 10 Hz, CJC 2 sec
Common Mode Rejection:
Negligible effect up to 140 dB, 240 V, 50 to 60 Hz
Temperature Coefficient:
150 ppm/°C sensor max Relay: Form A/SPST contacts
2 A/250 Vac, resistive
SSd (dc Pulse Driver):
To switch a remote SSR 5 Vdc (+0/-15%) 15 mA non-isolated
Operating Ambient Range:
0 to 50°C (32 to 130°F)
Case Material:
Flame retardant polycarbonate
Weight:
CN9300: 120 g (4.3 oz) CN9400: 120 g (4.3 oz) CN9500: 110 g (3.9 oz)
1
32 DIN Panel Cutout Size:
45 x 22.2 mm (1.77 x 0.87")
9.5 mm (0.374") maximum panel thickness
1
16 DIN panel cutout size:
45 mm square (1.772")
9.5 mm (0.374") maximum panel thickness
Maximum Recommended Wire Size: 18 AWG
Inductive Loads: To prolong relay contact life and suppress interference, it is a recommended engineering practice to use a snubber circuit, such as OMEGA’s
CNQUENCHARC (see “To Order”)
INSTRUMENTATION
D
D-158
Line
CN9500
CN9300 CN9400
Output
SP1
Comms option
(when fitted)
1A
Fuses
Sensor
CN9300, CN9400 AND CN9500 Specification
CN9300
9 10 11
+
1 2 3 4 5 6 7 8
Sensor
12 13 14 15 16
+
15mA
5Vdc
Output
SP1
+
SSR
Output
SP2
Open in
alarm state
LN
Supply
CN9400
Neutral
CN9500
Line
Comms option
(when fitted)
1A
Fuses
Sensor
9 10 11 12 13 14 15 16
+
+
15mA
5Vdc
1 2 3 4 5 6 7 8
Output
Sensor
SP2
Off in alarm
state
LN
Supply
Neutral
The dc Pulse output is allocated to SP1 and wired
to switch the load (heater) using an SSR
Output 1 Indicator
Output 2 Indicator
Function
Key
Model CN9300/CN9400
Dimensions in mm (in)
Down Arrow
Up
Arrow
116.2 (4.57)
Load
Output 1 Indicator
Function
Key
44.8
(1.76)
Down
Arrow
The relay output is allocated to SP1 and wired
to switch the load (heater) using a contactor
Output 1 Indicator
Output 2 Indicator
Up
Arrow
Model CN9500
Dimensions in mm (in)
Output 2 Indicator
Function
Key
Down
Arrow
51.0 (2.0)
Load
Up
Arrow
51.0 (2.0)
includes
gasket
51.0 (2.0)
includes gasket
106.7 (4.2)
with gasket fitted
44.8
(1.76)
D-159
22.0
(0.87)
28.5
(1.12)
Includes
gasket
106.7 (4.2)
with gasket fitted
116.2 (4.57)
Loading...