U 3-Year Warranty
U 4-Digit Display
U 5 Alarm Configurations
U Single Ramp and Soak
U PID Heat-Cool Control
U NEMA-4 (IP66) Faceplate
U Sleeve Mounting
U Security Lockouts
Optional:
U RS-232 or RS-485
Communications
U Communications
Software: CN9-SW
U Low Voltage Power
CN9500 Series
$
169
Basic Unit
The new 1⁄32 DIN CN9500,
1
⁄16 DIN CN9300 Single Display
and1⁄16 DIN CN9400 Dual Display
controllers follow the OMEGA
tradition of innovative design.
Building on the success of the
CN132 and CN9000A series, the
new models include several new
features, the most important being
the option of a low cost serial
communicating system with easy to
use Windows-based software.
1
⁄16 DIN
CN9400 Series
$
Basic Unit
1
⁄32 DIN
The CN9-SW series software
bridges the gap between the “stand
alone” system and full SCADA of
Fieldbus control networks by
providing a facility for remote
supervision of up to 32 instruments
using MODBUS protocol. It requires
only a modest investment and can
be operated by anyone with a
medium specification PC or laptop
that can be run with Windows 95
or Windows NT.
199
All units
shown
slightly
larger than
actual size
D-157
Page 2
Application: Multiple CN9500 Series Controllers set up with the CN9-SW Software ($159), see page D-161.
Specifications
Power: 100 to 240 Vac, ±10%,
50 to 60 Hz, 4 VA; Optional 12
or 24 Vac/dc, ±20%, 50 to 60 Hz,
4 VA Polarity is not required.
The controllers are fitted with an
internal 250 mA time lag fuse.
Display: 4-digit LED, 10 mm (0.4"),
high brightness green display
-199 to 9999 counts
Display Range:
(hi-res mode -199.9 to 999.9)
Range: Sensor limited 2000°C/3500°F;
-99.9 to 999.9° in 0.1° resolution
Display Indicators:
Process temperature (PV),
Setpoint (SP), LED output
indicators-flashing
Output 1 (SP1 square), green;
Output 2 (SP2 round), red;
error messages,
Function/Option mnemonics
mV range: 0 to 50 mV
(1 ohm shunt resistor supplied
for mA inputs)
Calibration Accuracy:
±0.25% of Full Scale ±1°C
Sampling Frequency:
Input 10 Hz, CJC 2 sec
Common Mode Rejection:
Negligible effect up to 140 dB,
240 V, 50 to 60 Hz
Temperature Coefficient:
150 ppm/°C sensor max
Relay: Form A/SPST contacts
2 A/250 Vac, resistive
SSd (dc Pulse Driver):
To switch a remote SSR 5 Vdc
(+0/-15%) 15 mA non-isolated
Operating Ambient Range:
0 to 50°C (32 to 130°F)
Case Material:
Flame retardant polycarbonate
Weight:
CN9300: 120 g (4.3 oz)
CN9400: 120 g (4.3 oz)
CN9500: 110 g (3.9 oz)
1
⁄32 DIN Panel Cutout Size:
45 x 22.2 mm (1.77 x 0.87")
9.5 mm (0.374") maximum panel
thickness
1
⁄16 DIN panel cutout size:
45 mm square (1.772")
9.5 mm (0.374") maximum
panel thickness
Maximum Recommended
Wire Size: 18 AWG
Inductive Loads:
To prolong relay contact life
and suppress interference, it
is a recommended engineering
practice to use a snubber
circuit, such as OMEGA’s
CNQUENCHARC (see “To Order”)
INSTRUMENTATION
D
D-158
Page 3
Line
CN9500
CN9300
CN9400
Output
SP1
Comms option
(when fitted)
1A
Fuses
Sensor
CN9300, CN9400 AND CN9500 Specification
CN9300
9 10 11
+
1 2 3 4 5 6 7 8
Sensor
12 13 14 15 16
–
+
–
15mA
5Vdc
Output
SP1
–
+
SSR
Output
SP2
Open in
alarm
state
LN
Supply
CN9400
Neutral
CN9500
Line
Comms option
(when fitted)
1A
Fuses
Sensor
9 10 11 12 13 14 15 16
–
+
–
+
15mA
5Vdc
1 2 3 4 5 6 7 8
Output
Sensor
SP2
Off in
alarm
state
LN
Supply
Neutral
The dc Pulse output is allocated to SP1 and wired
to switch the load (heater) using an SSR
Output 1 Indicator
Output 2
Indicator
Function
Key
Model CN9300/CN9400
Dimensions in mm (in)
Down
Arrow
Up
Arrow
116.2
(4.57)
Load
Output 1 Indicator
Function
Key
44.8
(1.76)
Down
Arrow
The relay output is allocated to SP1 and wired
to switch the load (heater) using a contactor
Output 1
Indicator
Output 2
Indicator
Up
Arrow
Model CN9500
Dimensions in mm (in)
Output 2
Indicator
Function
Key
Down
Arrow
51.0
(2.0)
Load
Up
Arrow
51.0
(2.0)
includes
gasket
51.0 (2.0)
includes gasket
106.7 (4.2)
with gasket fitted
44.8
(1.76)
D-159
22.0
(0.87)
28.5
(1.12)
Includes
gasket
106.7 (4.2)
with gasket fitted
116.2 (4.57)
Page 4
Model
CN9500
1
Input Ranges
ThermocoupleType(Units Are °C/°F Switchable)°C
B
E
J
K
L (J DIN)Fe-Constantan0 to 800 °C32 to 1472°F0.5
N
S
R
T
Notes: Type B: 5° (70-500°C), Types K and N: 1° >350°C Exceptions: Types R and S: 5° <300°C,Type T: 1°, -25° or >150°C RTD/Pt100: 0.5<-100°C
Sensor TypeType(Units are °C/°F Switchable)°C
RTD2-Wire, 100 ΩPt200 to 400°C-273 to 752°F0.25
Linear Process Inputs (Input mV range: 0 to 50 mV) (1 ohm shunt resistor is supplied for mA inputs)
Input TypeSignal SpanMaximum Scale SettingsLinearity °C
Linear Process0 to 20 mV-250 to 3000±0.5%
Pt-30%Rh/Pt-6%Rh0 to 1800 °C32 to 3272°F2.0
CHROMEGA®-Constantan0 to 600 °C32 to 1112°F0.5
Iron-Constantan0 to 800 °C32 to 1472°F0.5
CHROMEGA®-ALOMEGA
NiCrosil-NiSil-50 to 1200 °C-58 to 2192°F0.25
Pt-13%Rh/Pt0 to 1600 °C32 to 2912°F2.0
Pt-10%Rh/Pt0 to 1600 °C 32 to 2912°F2.0
OMEGACARESMextended warranty program is available for models shown on this page. Ask your sales representative for full details when
placing an order. Comes with complete operator’s manual.
Ordering Example: CN9312-C4-LV,1⁄ 16 DIN Controller with relay and pulse output, RS-485 communications and low voltage power 12-24 Vac/Vdc,
$180 + 50 = $230. OCW-1 OMEGACARESMextends standard 3-year warranty to a total of 4 years ($23), $230 + 23 = $253.
(Specify Model Number)
1
⁄16DIN Single DisplayRelayRelay
1
⁄16DIN Single DisplayRelayPulse
1
⁄16DIN Single Displaydc Pulsedc Pulse
1
⁄16DIN Dual DisplayRelayRelay
1
⁄16DIN Dual DisplayRelaydc Pulse
1
⁄16DIN Dual Displaydc Pulsedc Pulse
1
⁄32DIN Single DisplayRelayRelay
1
⁄32DIN Single DisplayRelaydc Pulse
1
⁄32DIN Single Displaydc Pulsedc Pulse
(Both Outputs can be Either Reverse or Direct Acting)
Additional Options
SUFFIXPRICEDESCRIPTION
-C2$50RS-232 Communications
-C450RS-485 Communications
-LV*N/C12-24 Vac/Vdc Low Voltage Power
Note: one communications option can be ordered per unit. Field installable communications
boards can be installed in the field. *Low voltage power option is not field installable and
available only on the following models: CN9312, CN9322, CN9512 and CN9522.
Field Installable Boards & Accessories
MODEL NO.PRICEDESCRIPTION
BD9-C2$50RS-232 Communications Board
BD9-C450RS-485 Communications Board
CN9-SW-DEMON/CDemonstration Software for Windows 95 and Windows NT
BD9-PROTOCOL*N/CThe Modbus Protocol Manual is not required when using the CN9-SW software
CN9-SW159Software for either RS-232 or RS-485 communications (refer to specifications).
*Note: This protocol manual provides the address information necessary to communicate with the CN9300/CN9400/CN9500 series controllers,
with communications options installed, when interacting with custom or other commercially available software.
D-160
Model CN9400
1
⁄16 DIN
INSTRUMENTATION
D
Page 5
CN9-SW SOFTWARE
COMPATIBLE WITH CN9300, CN9400 AND CN9500
SERIES CONTROLLERS
CN9-SW
$
159
Windows 95 and
Windows NT Compatible
U Communications Software
Designed for Either
RS-232 or RS-485
U Remote Setpoint
Adjustment
U Instrument Configuration
U Settings Saved to File
U Instrument Program
Cloning
U Logging and Charting
U Log-On Change Feature
U Real-Time and Historical
Mode with Zoom Facility
U Live Display
U Password Security
U Print Options
U Software Can Support Up
to 128 CN9300, CN9400 or
CN9500 Controllers
Hardware Requirements
U Pentium Processor with a
Minimum of 16 Meg of RAM
U A Minimum of 20 Mb Free
Hard Disk Space Is
Recommended
U Graphic Display Adapter
Capable of Displaying
256 Colors (VGA)
U Serial Port for Single
RS-232 Instrument
(or RS-485 Adaptor for
Multiple Instruments)
U MS Mouse and Keyboard
U CN9300, CN9400, CN9500
Fitted with RS-232 or
RS-485 Communications
1
⁄16 DIN
The CN9-SW software is designed
to interface with the CN9300,
CN9400 and CN9500 series
controllers with optional
communication hardware.
The CN9-SW takes up
approximately 1Mb. The size is
dependent on the number of
controllers and the frequency that
they are being logged. A very
approximate figure is per reading:
12 bytes date/time plus 4 bytes for
each instrument being logged.
Designed for use on laptops or
PC’s, this new development
provides the user with:
Model CN9300
• Time saving benefit and convenience
of remotely configuring and
adjusting units.
• Saving and retrieving settings to
and from files.
• Cloning settings to other
instruments.
• Highly flexible logging and
“real time” charting capability for
providing hard copy QA records
for ISO-9000 and other
management purposes.
Screen displaying alarm condition on instrument 1.
Software alarms provide a screen indication if the measured value falls
below the low alarm and/or rises above the high alarm settings.
D-161
Page 6
The CN9-SW software
is a powerful process
development tool for the
OEM customer or process
engineer. With compatible
modems and PC computers,
remote site supervisory control
and data acquisition can take place
to facilitate periodic or continuous
monitoring and troubleshooting.
Data is stored to file in a tamper
resistant format to ensure the
integrity of reports for quality
monitoring requirements. Build your
own multi-loop system with the
CN9300/CN9400/CN9500 series
controllers and CN9-SW software.
Allows both local and remote
adjustment. The CN9-SW software
can be used as a production tool for
the OEM. Downloading menu
settings to controllers during
production saves time and
eliminates errors.
Screen depicting the setup of the
cloning function for multiple
controllers. When a satisfactory
instrument configuration has been
achieved, these settings can be
cloned to other instruments
on the network or saved to a file
for later use.
Model CN9500,
1
⁄32 DIN
To Order
(Specify Model Number)
Model NumberPriceDescription
CN9-SW$159Software
Comes with complete operator’s manual
Ordering Example: CN9-SW, software for
CN9300, CN9400, CN9500
Series Controller, $159
Model CN9400
1
⁄16 DIN
Sample of graph displaying "real time
charting." Software is capable of
logging readings from up to 128
instruments which it stores in data
files. The data can be exported into
text files in C.S.V. (Comma Separated
Variable) format. In addition, up to 12
controllers can be displayed on a
single chart, or individual charts can
be set up for each instrument.
Virtual full color chart recorder can
log process variables such as: °C, °F,
Bar, PSI, pH, or rH. User definable
engineering unit "Set" can be
selected on the controller to log
other process variables.
Calibrators, Connectors, General Test and Measurement
Instruments, Glass Bulb Thermometers, Handheld Instruments
for Temperature Measurement, Ice Point References,
Indicating Labels, Crayons, Cements and Lacquers, Infrared
Temperature Measurement Instruments, Recorders Relative
Humidity Measurement Instruments, RTD Probes, Elements
and Assemblies, Temperature & Process Meters, Timers and
Counters, Temperature and Process Controllers and Power
Switching Devices, Thermistor Elements, Probes and
Assemblies,Thermocouples Thermowells and Head and Well
Assemblies, Transmitters, Wire
Flow and Level
Air Velocity Indicators, Doppler Flowmeters, Level
Measurement, Magnetic Flowmeters, Mass Flowmeters,
Pitot Tubes, Pumps, Rotameters, Turbine and Paddle Wheel
Flowmeters, Ultrasonic Flowmeters, Valves, Variable Area
Flowmeters, Vortex Shedding Flowmeters
pH and Conductivity
Conductivity Instrumentation, Dissolved Oxygen
Instrumentation, Environmental Instrumentation, pH
Electrodes and Instruments, Water and Soil Analysis
Instrumentation
Data Acquisition
Auto-Dialers and Alarm Monitoring Systems,
Communication Products and Converters, Data
Acquisition and Analysis Software, Data Loggers
Plug-in Cards, Signal Conditioners, USB, RS232, RS485
and Parallel Port Data Acquisition Systems, Wireless
Transmitters and Receivers
Band Heaters, Cartridge Heaters, Circulation Heaters,
Comfort Heaters, Controllers, Meters and Switching
Devices, Flexible Heaters, General Test and Measurement
Instruments, Heater Hook-up Wire, Heating Cable
Systems, Immersion Heaters, Process Air and Duct,
Heaters, Radiant Heaters, Strip Heaters, Tubular Heaters
click here to go to the omega.com home page
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.