OMEGA
CARE
SM
Extended Warranty
Program
PID AUTOTUNE TEMPERATURE/
PROCESS CONTROLLERS
1
⁄16 DIN
CN9300 Series
$
180
Basic Unit
U 3-Year Warranty
U 4-Digit Display
U 5 Alarm Configurations
U Single Ramp and Soak
U PID Heat-Cool Control
U NEMA-4 (IP66) Faceplate
U Sleeve Mounting
U Security Lockouts
Optional:
U RS-232 or RS-485
Communications
U Communications
Software: CN9-SW
U Low Voltage Power
CN9500 Series
$
169
Basic Unit
The new 1⁄32 DIN CN9500,
1
⁄16 DIN CN9300 Single Display
and1⁄16 DIN CN9400 Dual Display
controllers follow the OMEGA
tradition of innovative design.
Building on the success of the
CN132 and CN9000A series, the
new models include several new
features, the most important being
the option of a low cost serial
communicating system with easy to
use Windows-based software.
1
⁄16 DIN
CN9400 Series
$
Basic Unit
1
⁄32 DIN
The CN9-SW series software
bridges the gap between the “stand
alone” system and full SCADA of
Fieldbus control networks by
providing a facility for remote
supervision of up to 32 instruments
using MODBUS protocol. It requires
only a modest investment and can
be operated by anyone with a
medium specification PC or laptop
that can be run with Windows 95
or Windows NT.
199
All units
shown
slightly
larger than
actual size
D-157
Application: Multiple CN9500 Series Controllers set up with the CN9-SW Software ($159), see page D-161.
Specifications
Power: 100 to 240 Vac, ±10%,
50 to 60 Hz, 4 VA; Optional 12
or 24 Vac/dc, ±20%, 50 to 60 Hz,
4 VA Polarity is not required.
The controllers are fitted with an
internal 250 mA time lag fuse.
Display: 4-digit LED, 10 mm (0.4"),
high brightness green display
-199 to 9999 counts
Display Range:
(hi-res mode -199.9 to 999.9)
Range: Sensor limited 2000°C/3500°F;
-99.9 to 999.9° in 0.1° resolution
Display Indicators:
Process temperature (PV),
Setpoint (SP), LED output
indicators-flashing
Output 1 (SP1 square), green;
Output 2 (SP2 round), red;
error messages,
Function/Option mnemonics
Thermocouple Cold Junction
Compensation Rejection:
20:1 (0.05°/°C) typical
Thermocouple External Resistance:
100 Ω max
Thermocouple: 9 types
Standards: IPTS/68/DIN43710
RTD Input: Pt100 2-wire (.00385)
Linear Process Inputs:
mV range: 0 to 50 mV
(1 ohm shunt resistor supplied
for mA inputs)
Calibration Accuracy:
±0.25% of Full Scale ±1°C
Sampling Frequency:
Input 10 Hz, CJC 2 sec
Common Mode Rejection:
Negligible effect up to 140 dB,
240 V, 50 to 60 Hz
Temperature Coefficient:
150 ppm/°C sensor max
Relay: Form A/SPST contacts
2 A/250 Vac, resistive
SSd (dc Pulse Driver):
To switch a remote SSR 5 Vdc
(+0/-15%) 15 mA non-isolated
Operating Ambient Range:
0 to 50°C (32 to 130°F)
Case Material:
Flame retardant polycarbonate
Weight:
CN9300: 120 g (4.3 oz)
CN9400: 120 g (4.3 oz)
CN9500: 110 g (3.9 oz)
1
⁄32 DIN Panel Cutout Size:
45 x 22.2 mm (1.77 x 0.87")
9.5 mm (0.374") maximum panel
thickness
1
⁄16 DIN panel cutout size:
45 mm square (1.772")
9.5 mm (0.374") maximum
panel thickness
Maximum Recommended
Wire Size: 18 AWG
Inductive Loads:
To prolong relay contact life
and suppress interference, it
is a recommended engineering
practice to use a snubber
circuit, such as OMEGA’s
CNQUENCHARC (see “To Order”)
INSTRUMENTATION
D
D-158
Line
CN9500
CN9300
CN9400
Output
SP1
Comms option
(when fitted)
1A
Fuses
Sensor
CN9300, CN9400 AND CN9500 Specification
CN9300
9 10 11
+
1 2 3 4 5 6 7 8
Sensor
12 13 14 15 16
–
+
–
15mA
5Vdc
Output
SP1
–
+
SSR
Output
SP2
Open in
alarm
state
LN
Supply
CN9400
Neutral
CN9500
Line
Comms option
(when fitted)
1A
Fuses
Sensor
9 10 11 12 13 14 15 16
–
+
–
+
15mA
5Vdc
1 2 3 4 5 6 7 8
Output
Sensor
SP2
Off in
alarm
state
LN
Supply
Neutral
The dc Pulse output is allocated to SP1 and wired
to switch the load (heater) using an SSR
Output 1 Indicator
Output 2
Indicator
Function
Key
Model CN9300/CN9400
Dimensions in mm (in)
Down
Arrow
Up
Arrow
116.2
(4.57)
Load
Output 1 Indicator
Function
Key
44.8
(1.76)
Down
Arrow
The relay output is allocated to SP1 and wired
to switch the load (heater) using a contactor
Output 1
Indicator
Output 2
Indicator
Up
Arrow
Model CN9500
Dimensions in mm (in)
Output 2
Indicator
Function
Key
Down
Arrow
51.0
(2.0)
Load
Up
Arrow
51.0
(2.0)
includes
gasket
51.0 (2.0)
includes gasket
106.7 (4.2)
with gasket fitted
44.8
(1.76)
D-159
22.0
(0.87)
28.5
(1.12)
Includes
gasket
106.7 (4.2)
with gasket fitted
116.2 (4.57)