Omega Products CN8502 User Manual

1
16 DIN Temperature/Process
Controllers
CN8500 Series
Starts at
$
264
NEMA 4X (IP65)
Front Panel
User Selectable
Ramp to Setpoint
Manual Operation
Optional RS232 or
RS485 Communications
Autotuning Heat or CoolThermocouple, RTD,
Voltage, or Current Input
Dual Output and Dual
Alarm Capability
Optional Remote Setpoint,
Transducer Power Supply and Recorder Output
Optional Power, 24 Vdc/Vac
a
P
b
a
l
i
a
v
a
g
e
m
o
l
e
n
a
p
Transition junction probes sold separately. See page A-78.
t
i
s
i
v
,
e
l
/
m
o
c
.
a
s
e
h
c
n
u
p
s
e
h
c
n
u
p
l
e
n
CN8501, $264.
The CN8500 temperature controller is extremely versatile and user-friendly. The operator needs to review only those parameters relevant to the particular application during setup. A dual digital display offers optimum process information at a glance. The dedicated upper display shows the process temperature, while the lower display displays setpoint and setup parameters. Individual LED’s identify the status of outputs, alarms, digital communications and special options. The CN8500 features a NEMA 4X (IP65) front panel and a universal power supply that accepts 103 to 253 Vac and 103 to 330 Vdc.
Control algorithms available are P, PI, PD, PID, or on/off. The autotune feature automatically sets proportional band, rate and reset before the process reaches setpoint. These parameters provide quick stabilization of both the heating and cooling process without overshoot, hunting or cycling. The standard dual control outputs can be configured in a variety of control and alarm applications such as
heat, heat/cool, heat/alarm, cool, or cool/alarm. The ramp to setpoint feature allows the user to define the rate of rise to reach the setpoint, thus minimizing thermal shock to the load during start-up.
Specifications
Performance
Accuracy: ±0.2% of full scale, ± digit Setpoint Resolution: 1 count/0.1 count Repeatability: ±1.0 count Temperature Stability: 5 µV/°C max;
3 µV/°C typical
Thermocouple Cold Junction Tracking: 0.05°C/°C ambient
Common Mode Rejection: >100 dB Series Mode Rejection: >70 dB Process Sampling: 10 Hz (100 ms)
Inputs
Thermocouple Lead Resistance:
100 max for rated accuracy
Response Time: 0.1, 1.0, or 10 s Decimal Position: Selectable
Outputs
Output #1: Reverse acting (heating) Output #2: Direct acting (cooling)
Mechanical Relay: Rated 5A @ 120 Vac,
3A @ 240 Vac
Current: 4-20 mA, 500 max Voltage: 20 Vdc pulse, 1 k minimum load Triac: SSR, 120/240 Vac, zero voltage
switched rated 1A continuous, 10 A surge @ 25°C
Alarms: Optically isolated triac rated 1A, 120/240 Vac @ 25°C
Control Characteristics
Setpoint Limits: Limited to configured
range for thermocouple and RTD; limited to scaled range
Alarms: Adjustable for high/low, process or deviation
Rate: 0 to 900 seconds Reset: 0 to 3600 seconds Cycle Time: 0.2 to 120 seconds Gain: 0 to 400 Gain Ratio: 0 to 2.0 (in 0.1 increments) On/Off Deadband: 1 to 100 counts Spread (Output 2): 0 to 100 counts
(above setpoint)
Damping: Adjustable (low, normal or high) Ramp to Setpoint: 1 to 100 minutes Autotune: Operator initiated from
front panel Manual Control: Operator initiated from
front panel
P-43
General
Power: 115 to 230 Vac ±10%,
50/60 Hz; 115 to 300 Vdc ±10% (auto-polarity), optional 24 Vdc/Vac
Display: Dual LED, 4-digit, orange process display, green menu/ parameter display; 9.2 mm (0.37")
Power Consumption: Less than 6 VA (instrument) @ 120 Vac
Weight: 0.25 kg (8 oz) Panel Cutout: 45 mm (1.772") square Dimensions: 53 H x 53 W x 18.3 mm
bezel (2.1 x 2.1 x 0.72")
Depth Behind Panel: 100 mm (3.937") Front Panel Rating: NEMA 4X (IP65) Operating Ambient Range:
0 to 55°C (32 to 131°F); 90% RH max, non-condensing
Memory Protection: Solid state non-volatile memory
Connections: Rear barrier strip with locking terminals
Contacts: Twin bifurcated
Bezel Dimensions
53
(2.1)
53
(2.1)
Dimensions: mm (in)
A
lso Available
1
in
8
D
IN
Sizes! See Page
and
1
4
DIN
P-57
Input Types and Ranges
Input Code Type Range Resolution
Iron-Constantan -18 to 760°C (0 to 1400°F) 1°C (1°F)
CHROMEGA
-ALOMEGA
C Copper-Constantan -129 to 316°C (-200 to 600°F) 1°C (1°F)
T
OMEGALLOY
Pt/13%Rh-Pt -18 to 1760°C (0 to 3200°F) 1°C (1°F) Pt/10%Rh-Pt -18 to 1760°C (0 to 3200°F) 1°C (1°F)
3-wire, 100 Pt -200 to 850°C (-328 to 1562°F) 1°C (1°F)
RTD
V5 0 to 5V, 1 to 5V Scalable (-1999 to 9999) Selectable V10 0 to 10V, 2 to 10V Scalable (-1999 to 9999) Selectable MV 0 to 50 mV, 10 to 50 mV Scalable (-1999 to 9999) Selectable MA 0 to 20 mA, 4 to 20 mA Scalable (-1999 to 9999) Selectable
3-wire, 100 Pt
®
®
®
-18 to 1349°C (0 to 2460°F) 1°C (1°F)
-18 to 1299°C (0 to 2370°F) 1°C (1°F)
-128.8 to 232.2°C 0.1°C
(-199.0 to 450.0°F) (0.1°F)
AVAILABLE FOR FAST DELIVERY!
To Order
Model Number Price Description CN8501(*)-(**) $264 Single output CN8502(*)-(**)-(***) 289 Dual output
Comes complete with operator’s manual.
** Specify input code: “TC” (thermocouple), “RTD”, “MV” (voltage to 50 mV), “V5” (voltage to 5V), “V10” (voltage to 10V) or “MA” (current to 20 mA). See input type table
above for details. *** Specify output code(s) from output options table below. Single output units can be ordered for either heat (reverse) or cool (direct) action.
For power option add suffix “-24” to model number for 24 Vdc/Vac power, and $25 to price.
Output Options (No Additional Cost)
Output Type (Reverse) Order Suffix (Direct)†Order Suffix 5 A Relay -R1 -R2
1 A SSR -T1 -T2 4 to 20 mA -F1 -F2 20 Vdc Pulse -DC1 -DC2
Single output controllers can be ordered for either heat (reverse) or cool (direct) acting. Ordering Example: CN8501TC-R2,
configured for cooling operation, $264.
Options (1⁄16 DIN—Only 1 Option Available Per Unit)
Order Suffix Add’l Price Description
-A $40 Dual alarms
-C2 95 RS232 communications
-C4 95 RS485 communications
-PV1
-PV2
-RSP1
-RSP2
-RSP3
-XP1 75 Transducer power supply, 15 Vdc
Not available for voltage or current input models with input codes “MV”, “V5”, “V10” or “MA”. Ordering Example: CN8502V5-F1-F2-C2, 0 to 5 Vdc input, dual 4 to 20 mA outputs, RS232
communications, $289 + 95 = $384.
Accessories
Model No. Price Description
CNQUENCHARC $8 Noise suppression RC snubber (2 leads),
CN8-SW
†† Free CN8-SW software download available at
(Specify Model Number)
First Output Heat Only Second Output Cool Only
1
††
P-44
75 4 to 20 mA recorder output 75 0 to 5 Vdc recorder output 75 Remote switch closed with 1 alarm 75 Remote switch open with 1 alarm 75 0 or 5 Vdc remote setpoint with 1 alarm
110 to 230 Vac
N/C Remote monitoring and control software
DIN controller, thermocouple input, 5 A relay output
16
omega.com/cn8501
P
Loading...
+ 1 hidden pages