Safety-related labels and symbols are attached on the locations shown below. If labels or symbols are
missing or illegible, contact Olympus.
Wireless Transmitter
CSA/UL marking
This instrument emits RF (Radio Frequency)
energy to perform intended functions.
FCC note
FCC ID number
IC number
Electric rating
The product name, rated voltage, and
notice for AC adapter are shown
WIRELESS TRANSMITTER
MODEL :UWIT-Y0001-TX
POWER INPUT : 12 V1 A
For use with power supply OLP-K027-M
Potential equalization terminal
Serial number plate
Manufacturer name
UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL
1
Labels and Symbols
Wireless Receiver
Potential equalization terminal
Electric rating
The product name, rated voltage, and
notice for AC adapter are shown
WIRELESS RECEIVER
MODEL :UWIT-Y0001-RX
POWER INPUT : 12 V0.8 A
For use with power supply OLP-K027-M
FCC note
FCC ID number
IC number
Manufacturer name
CSA/UL marking
This instrument emits RF (Radio Frequency)
energy to perform intended functions.
Serial number plate
AC Adaptor
Electric rating
The product name, rated voltage, and
notice for AC adapter are shown
OLYMPUS
AC Adapter
Model Name: OLP-K027-M
INPUT : 100–240 V1–0.5 A, 50/60 Hz
OUTPUT : 12 V1.3 A
Manufacturer name
2
UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL
Labels and Symbols
Back cover of this instruction manual
SymbolDescription
Manufacturer
Authorized representative in the European Community
UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL
3
Important Information — Please Read Before Use
Important Information — Please Read Before Use
Intended use
The Olympus Wireless Image Transmitter Unit UWIT-Y0001 is a paired transmitter and receiver,
intended for delivery of video signals over a radio-frequency link to a video display during endoscopic
and general surgical procedures. The Olympus UWIT-Y0001 is a non-sterile reusable device not
intended for use in the sterile field. It is intended for use by qualified physicians having complete
knowledge of these surgical procedures.
Instruction manual
This instruction manual contains essential information on using this Wireless Image Transmitter Unit
safely and effectively. Before use, thoroughly review this manual and the manuals of all equipment
which will be used during the procedure and use the equipment as instructed.
Keep this and all related instruction manuals in a safe, accessible location. If you have any questions
or comments about any information in this manual, please contact Olympus.
Terms used in this manual
Video system center:
The video system center is a device that converts signals from a videoscope or video
converter, camera head into monitor images.
Wall mains outlet:
The wall mains outlet is a wall AC mains power outlet socket having the exclusive terminal
for grounding.
4
UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL
Important Information — Please Read Before Use
User qualifications
If there is an official standard on user qualifications to perform endoscopy and endoscopic treatment
that is defined by the medical administration or other official institutions, such as academic societies on
endoscopy, follow that standard. If there is no official qualification standard, the operator of this
instrument must be a physician approved by the medical safety manager of the hospital or person in
charge of the department (department of internal medicine, etc.). The physician should be capable of
safely performing the planned endoscopy and endoscopic treatment following guidelines set by the
academic societies on endoscopy, etc., and considering the difficulty of endoscopy and endoscopic
treatment. This manual does not explain or discuss endoscopic procedures.
Instrument compatibility
Refer to the “ System chart” on page 43 to confirm that this Wireless Image Transmitter Unit is
compatible with the ancillary equipment being used. Using incompatible equipment can result in
patient injury or equipment damage and makes it impossible to obtain the expected functionality.
This instrument complies with the EMC standard for medical electrical equipment; edition 3
(IEC 60601-1-2: 2007), edition 2 (IEC 60601-1-2: 2001). However, when connected with an instrument
that complies with the EMC standard for medical electrical equipment; edition 1 (IEC 60601-1-2: 1993),
the whole system complies with edition 1.
Repair and modification
This Wireless Image Transmitter Unit does not contain any user-serviceable parts. Do not
disassemble, modify or attempt to repair it; patient or operator injury, equipment damage and/or the
impossibility to obtain the expected functionality can result. Some problems that appear to be
malfunctions may be correctable by referring to Chapter 7, “Troubleshooting”. If the problem cannot be
resolved using the information in Chapter 7, contact Olympus. This instrument is to be repaired by
Olympus technicians only.
Change or modifications not expressly approved by the party responsible for compliance could void
the user’s authority to operate the equipment.
All interface cables used to connect peripherals must be shielded in order to comply with the limits for
a digital device pursuant to Subpart B of Part 15 of FCC Rules.
UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL
5
Important Information — Please Read Before Use
DANGER
Signal words
The following signal words are used throughout this manual:
DANGER
WARNING
CAUTION
NOTE
Indicates an imminently hazardous situation which, if not avoided, will result in
death or serious injury.
Indicates a potentially hazardous situation which, if not avoided, could result in
death or serious injury.
Indicates a potentially hazardous situation which, if not avoided, may result in minor
or moderate injury. It may also be used to alert against unsafe practices or potential
equipment damage.
Indicates additional helpful information.
Dangers, warnings, and cautions
Follow the dangers, warnings and cautions given below when handling this Wireless Image
Transmitter Unit. This information is to be supplemented by the dangers, warnings, and cautions given
in each chapter.
• Strictly observe the following precautions. Failure to do so may place the patient
and medical personnel in danger of electric shock.
Keep fluids away from all electrical equipment. If fluids are spilled on or into the
unit, stop operation of the Wireless Image Transmitter Unit immediately and
contact Olympus.
Do not prepare, inspect or use this Wireless Image Transmitter Unit with wet
hands.
• Never install and operate the Wireless Image Transmitter Unit in locations where:
The concentration of oxygen is high;
Oxidizing agents (such as nitrous oxide (N
Flammable gases are present in the atmosphere;
Flammable liquids are near.
Otherwise, explosion or fire may result because this Wireless Image Transmitter
Unit is not explosion-proof.
O)) are present in the atmosphere;
2
6
UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL
Important Information — Please Read Before Use
WARNING
CAUTION
• In case of Wireless Image Transmitter Unit failure or malfunction, always keep
another Wireless Image Transmitter Unit in the room ready for use.
• Only use the supplied AC adaptor. Do not use the supplied AC adaptor to power
other devices. The equipment may fail or the power cord may burn.
• Always use the power cord and connection cables that were shipped with the
monitor or mobile workstation. Using other power cords or connection cables may
result in an electric shock or malfunction.
• Do not use a pointed or hard object to press the buttons on the front panel. This
may damage the buttons.
• Do not touch the electrical contacts inside the Wireless Image Transmitter Unit’s
connectors.
• Do not apply excessive force to this Wireless Image Transmitter Unit and/or other
instruments connected. Otherwise, damage and/or malfunction can occur.
UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL
7
EMC (Electromagnetic Compatibility)
EMC (Electromagnetic Compatibility)
• In order to provide the intended functionality (HDTV image transmission), the Wireless Image
Transmitter Unit (UWIT-Y0001) emits RF (Radio Frequency) energy while in operation. This
may affect electrical devices in the vicinity.
• The Wireless Image Transmitter Unit (UWIT-Y0001) utilizes RF signals shown below.
Accordingly, it is subject to electromagnetic interference from other in-band equipment in the
vicinity.
Central Frequency60.48 GHz (When using CH1)
62.64 GHz (When using CH2)
Frequency range of
possible interference
Modulation methodOFDM
High-frequency
output
59.40 – 61.56 GHz (When using CH1)
61.56 – 63.72 GHz (When using CH2)
Less than +40 dBm
8
UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL
Summary of Equipment Functions
Summary of Equipment Functions
This Wireless Image Transmitter Unit transmit HDTV video signal over radio frequency channel with no
compression and low latency between a pair of transmitter and receiver. This instrument supports
functions below.
Transmitting function of HDTV video signal over radio
frequency channel
• When using the HD-SDI input connector for the Wireless Transmitter
A paired Wireless Transmitter and Receiver can transmit 1080i (60/50 Hz) digital HDTV
video signal over radio frequency channel
• When using the DVI input connector for the Wireless Receiver
A paired Wireless Transmitter and Receiver can transmit 1080p (60/50 Hz) digital HDTV
video signal and SXGA: 1280 × 1024 (60 Hz) digital video signal over radio frequency
channel
Pair changing function
By using the SELECT button of the Wireless Transmitter and Receiver, the Channel (CH1 or CH2) for
pairing Transmitter and Receiver can be set manually.
oSee Section 5.2, “Connection of the Wireless Transmitter and Receiver”.
UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL
9
Summary of Equipment Functions
10
UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL
1.1 Checking the package contents
Chapter 1Checking the Package
Contents
1.1Checking the package contents
Match all items in the package with the components shown below. Inspect each item for damage. If the
Wireless Image Transmitter Unit is damaged, a component is missing, or you have any questions, do
not use the Wireless Image Transmitter Unit; immediately contact Olympus.
Wireless Transmitter
Wireless Transmitter (UWIT-Y0001-TX)
Ch.1
AC adaptorAC cordSDI cableInstruction manual
UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL
11
1.1 Checking the package contents
Ch.1
Wireless Receiver
Wireless Receiver (UWIT-Y0001-RX)
AC adaptorAC cordDVI cable (MAJ-1945)Access sheet
12
UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL
1.1 Checking the package contents
Optional equipment
The following products are optional Olympus products that may be purchased separately.
Attachment for UWIT (MAJ-Y0149)
Attachment for UWIT
(MAJ-Y0149)
Screw (for AC adaptor) (2 pcs.)Attachment for AC adaptorAccess sheet
Screw (for installing UWIT-Y0001-TX
or UWIT-Y0001-RX) (2 pcs.)
Screw (for installing OEV261H)
DVI cable (MAJ-1945)
Ch.1
(4 pcs.)
DVI cable (MAJ-1945)Access sheet
UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL
13
Ch.1
1.1 Checking the package contents
14
UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL
2.1 Symbols and descriptions
Chapter 2Nomenclature and
Functions
The instrument nomenclature, functions, and specifications are described in this chapter.
2.1Symbols and descriptions
Front panel
SymbolDescription
Select
Rear panel
SymbolDescription
Serial number
Potential equalization terminal
Ch.2
UWIT-Y0001-TX, UWIT-Y0001-RX INSTRUCTION MANUAL
15
Loading...
+ 43 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.