This specification applies to OKIPOS 425D/425D/425DF, a 9-pin type serial dot impact printer.
This device is a desk-top serial dot impact printer, used exclusively as the output device for POS
(Point-of-sales) system.
• OKIPOS 425D :OKI Dual Standard Version
• 425D :OEM Dual Standard Version
• 425DF :OEM Dual Fiscal Version
1.2Characteristics
• Print Head with 9 pins mounted
• Direct access control panel
• Print Head Life :200million characters (Ave.) – Utility Print Quality
• Paper copies :Cut Sheet Paper : Total 5 pages (original 1 + 4 copies)
Sprocket Paper (Tractor) : Total 4 pages (original 1 + 3 copies)
• Emulation :• OEM Fiscal Type: OKI Epson Emulation + New Defined
Command to support OEM fiscal command
• OEM Standard Type: OKI Epson Emulation
• OKI Standard Type: OKI Epson Emulation (ESC/POS similar)
• Interface :IEEE-1284 bidirectional parallel or RS-232C Interface
• Line Feed Increments : OEM Fiscal/OEM Standard Type : 1/6", n/216"(0≤n≤255)OKI Standard Type : 1/6", n/144"(0≤n≤255)
• Agency approved by UL, CSA, CE and FCC
• Variations :• OEM Fiscal Version
• OEM Fiscal + MICR Version
• OEM Standard Version
• OEM Standard + MICR Version
• OKI Standard Version
• OKI Standard + MICR Version
(MICR : Magnetic-Ink-Character-Recognition)
• Options :Front Tractor: User Option
Parallel Interface PCB: Dealer Option (OKI/OEM Standard Type)
RS-232C Interface PCB : Dealer Option (OKI Standard Type)
Note) Both of the parallel and RS-232C interface PCB cannot be contained.
41049413TX Rev.55 /
2.CONFIGURATION
2.1Standard Printer Configuration
• Mechanical Unit
• Print Head
• Control Board
• Universal Power Supply
• Covers
• Lower Shield
• Rewinder
2.2Variations
• OEM Fiscal Version
• OEM Fiscal + MICR Version
• OEM Standard Version
• OEM Standard + MICR Version
• OKI Standard Version
• OKI Standard + MICR Version
(MICR : Magnetic-Ink-Character-Recoghition)
2.3Options
Front Tractor: User Option
Parallel Interface PCB: Dealer Option (OKI/OEM Standard Type)
RS-232C Interface PCB : Dealer Option (OKI Standard Type)
Note) Both of the parallel and RS-232C interface PCB cannot be contained.
41049413TX Rev.56 /
2.4Block Diagram
Printer Control PCB
Fiscal Control PCB
Power Supply Unit
FG
FG
ON
OFF
AC SW
Fiscal
Memory
PCB
Print Head
SP Motor
LF Motor (Receipt)
LF Motor (Slip/Journal)
MICR Roller Solenoid
(Only with MICR Type)
Slip/Journal Gear Change Solenoid
Platen Change Sensor
Receipt Paper Near End Sensor
Receipt Paper End Sensor
Journal Paper End Sensor
Tractor Sensor
Cover Open Sensor
Journal Paper Near End Sensor
Platen Change Motor
Operation
Panel
Slip Sensor
Validation Sensor
(Only Space)
Fiscal
Memory
PCB
40P
20P16P
20P
16P
Parallel Interface
RJ11
RS232C(9Pin)
RS232C(9Pin)
AC IN
: OEM
M
M
M
Auto Cutter
M
M
Transit PCB
Pow
MICR Control PCB
(Only with MICR Type)
MICR Head (Only with
MICR T ype)
1) OEM Fiscal Type
41049413TX Rev.57 /
2) OKI/OEM Standard Type
FG
Print Head
SP Motor
LF Motor (Receipt)
LF Motor (Slip/Journal)
MICR Roller Solenoid
(Only with MICR Type)
Slip/Journal Change Solenoid
Platen Change Sensor
Receipt Paper Near End Sensor
Receipt Paper End Sensor
Journal Paper End Sensor
Tractor Sensor
Cover Open Sensor
Journal Paper Near End Sensor
Platen Change Motor
Operation
Panel
Slip Sensor
Validation Sensor
M
M
M
Auto Cutter
M
M
Transit PCB
MICR Control PCB
(Only with MICR Type)
MICR Head (Only with
MICR T ype)
RS-232C
Interface
PCB
or
Printer Control PCB
Power Supply Unit
FG
ONOFF
AC SW
Pow
RS-232C(25Pin)
Cash Drawer
Parallel(36Pin)
Customer Display
AC IN
Dealer option
Only OKI Standard Type
Parallel
Interface
PCB
Dealer
Option
Only OKI
Standard T ype
41049413TX Rev.58 /
3.GENERAL SPECIFICATIONS
3.1Power Requirements
1) Input power
Single-phase AC
Voltage :Universal120VAC±15% ~ 230VAC±15%
Frequency : 50/60Hz ±2%
2) Power consumption (without Fiscal Control PCB)
Local Test : Max. 40W (at Local Printing)
Idle :Max. 15W
3) AC power cable
Length :Approximately 5.9 It (1.8 m)
Cable conforms to the UL, CSA, and European Standards.
The AC power cable can be easily disconnected from the printer. The desired printer operating
voltage. Such Cables as conform to the UL, CSA, and European Standards with a length of
approximately 5.9 lt. (1.8 m) should be used, which can be easily disconnected from the printer
and used under the desired printer operating voltage.
Note :
AC power cable is not supplied.
3.2Electric Insulation
1) Insulation resistance
5 megohms or more when measured between AC input line and frame using DC 500V
megohmmeter.
2) Dielectric strength
1,500 VAC (50Hz / 60Hz)
(No damage will result when the above voltage is applied between the AC input line and frame
for 60 seconds.)
3.3Environmental Conditions
1) Ambient temperature and relative humidity
OperatingNon-operatingStorageTransportationUnit
Temperature41 to 10432 to 109.414 to 122-40 to 158°F
(5 to 40)(0 to 43)(-10 to 50)(-40 to 70)(°C)
Relative20 to 8010 to 905 to 9510 to 95%RH
Humidity
Avoid condensation at all times.
2) Vibration
Operating :Max. 0.3G (5 to 150 Hz) (except at resonant frequency)
Non-operating : Max. 1.5G (5 to 150 Hz) (except at resonant frequency)
3) Impact (Drop Test)
Packing :36" Drop
4) Noise
Max. 70 dBA :Roll paper (1P) Local print.
41049413TX Rev.59 /
3.4Agency Approvals
UL :UL 1950
CSA : CSA C22.2 N0.950
CE :EN 50081-1 : 1992 (EN55022 class B)
EN 50082-1 : 1992
EN 60950
FCC : class A
3.5Communication Interface Specifications
3.5.1Fiscal Interface (OEM Fiscal Type)
1) Connectors (to Fiscal Control PCB)
Printer Control PCB side : 40 pin receptacle FL40A2FO (Oki Electric Cable Co., Ltd.) or
equivalent.
Note:
The above connectors are used not for input/output from/to an external host
computer, but for connection to Fiscal Control PCB (the Control PCB created by
the user and installed inside the device).
41049413TX Rev.510 /
2) Interface Spec. (Between Printer Control Board and Fiscal Control Board)
1 Parallel interface signal part (IEEE-1284 parallel equivalent)
a)Compatible mode
Pin No.
2~9
Compatible mode
1
10
11
12
13
14
31
32
36
nStrobe
Data bit 1-8
nAck
Busy
PError
Select
nAutoFd
nlnit
nFault
nSelectIn
Direction
From Fiscal Control Board
From Fiscal Control Board
To Fiscal Control Board
To Fiscal Control Board
To Fiscal Control Board
To Fiscal Control Board
From Fiscal Control Board
From Fiscal Control Board
To Fiscal Control Board
From Fiscal Control Board
Function
Data strobe
Data from Fiscal Control Board
Receive completion
Data receiving impossible
Error
Online
1284 mode move request
Initialization
Error
1284 mode move request
b)Nibble mode
Pin No. Signal nameDirectionFunction
1
2~9
10
HostClk
Data bit 1-8
PtrClk
From Fiscal Control Board
From Fiscal Control Board
To Fiscal Control Board
"High" fix
Fiscal Control Board can drive (not used)
Sets "Low" when Fiscal Control Board is informed
that nibble data is available, and returns this signal
to "High" in response to HostBusy "High".
11
12
13
14
31
32
36
PtrBusy
AckDataReq
XFlag
HostBusy
nlnit
nDataAvail
1284 Active
Note :
Pin arrangement
1
2
To Fiscal Control Board
To Fiscal Control Board
To Fiscal Control Board
From Fiscal Control Board
From Fiscal Control Board
To Fiscal Control Board
From Fiscal Control Board
Indicates bit3 or bit7 of nibble data.
During idling, outputs forward channel status.
Indicates bit2 or bit6 of nibble data.
During idling, outputs if forward data exists or not.
Indicates bit1 or bit5 of nibble data.
During idling, outputs acknowledgment level of Xflag.
Indicates preparation status for data receive of
Fiscal Control Board.
Initialization
Indicates bit0 or bit4 of nibble data.
During idling, outputs if forward data exists or not.
Request 1284 mode completion from Fiscal Control
Board.
39
40
41049413TX Rev.511 /
2 Power supply line (Common in comptible mode and nibble mode)
17
18
19
20
37
Power supply
name
+5V
EL (0V)
+40V
Direction
–
–
–
Function
+5VDC power supply (Max 400mA)
Signal ground (Return for +5V)
+40VDC power supply (Max 200mA)
Pin No.
38
39
EP (0V)
–
0V (+40VDC power supply return)
40
Cannot supply +5V and +40V at the same time.
3 Operation board control signal (Common in compatible mode and nibble mode)
22
23
24
25
27
28
29
30
Power supply
name
OP_SW1-N
OP_SW2-N
OP_SW3-N
OP_SW4-N
FIS_LED1-N
FIS_LED2-N
FIS_LED3-N
FIS_LED4-N
Direction
To Fiscal Control Board
To Fiscal Control Board
To Fiscal Control Board
To Fiscal Control Board
From Fiscal Control Board
From Fiscal Control Board
From Fiscal Control Board
From Fiscal Control Board
Function
Becomes low level when SW1 is pressed down.
Becomes low level when SW2 is pressed down.
Becomes low level when SW3 is pressed down.
Becomes low level when SW4 is pressed down.
At low level, LED1 lights.
At low level, LED2 lights.
At low level, LED3 lights (Orange).
At low level, LED4 lights (Green).
Pin No.
When OP_SWn-N signal (22-25pin) is not used, Fiscal side should be "Non-connect." (If
signal level "L" is input, operation switches are not detected, which causes malfunction.)
When LED is not controlled by FIS_LEDn-N signal (27-30pin), Fiscal side should be "Nonconnect." (When signal level "L" is input, the LED incorrectly lights.)
4 Others (Common in compatible mode and nibble mode)
Pin No. Signal nameDirectionFunction
15
Fis_Check-N
From Fiscal Control Board
Signal that detects if Fiscal Control Board is
assembled or not.
Printer Control Board side finds it "not assembled" in high level, and finds it "assembled" in
low level. Therefore, Fiscal Control Board
side always should be 0V.
16
21
Fis_Check2-N
Pow Good-N
From Fiscal Control Board
To Fiscal Control Board
Not used
Becomes Low level when AC input is less
than 90 5 VAC.
26
33
34
35
NC
FIS_HOT1
FIS_HOT2
NC
–
To Fiscal Control Board
To Fiscal Control Board
–
Not connected.
Hot-line 1
Hot-line 2
Not connected.
For details on parallel interface time chart, refer to "3.5.2(5) Parallel Inter face timing chart".
Direction
From host PC
From host PC
To host PC
To host PC
To host PC
To host PC
From host PC
–
–
–
To host PC
From host PC
To host PC
To host PC
Function
Data Strobe
Data from host PC
Receive completion
Data receiving impossible
OEM Standard Type : Error
OKI Standard Type : Paper End
Online
1284 mode move request
Not connected
Signal ground
Frame ground
+5VDC power supply (Max 400mA)
Initialization
Error
OEM Standard Type : Not used
OKI Standard Type : Cash Drawer status signal