Absolute Maximum Ratings (Note)
If Military/Aerospace specified devices are required,
please contact the National Semiconductor Sales
Office/Distributors for availability and specifications.
Supply Voltage 7V
Input Voltage 5.5V
Operating Free Air Temperature
Range
b
55§Ctoa125§C
Storage Temperature Range
b
65§Ctoa150§C
Note:
The ‘‘Absolute Maximum Ratings’’ are those values
beyond which the safety of the device cannot be guaranteed. The device should not be operated at these limits. The
parametric values defined in the ‘‘Electrical Characteristics’’
table are not guaranteed at the absolute maximum ratings.
The ‘‘Recommended Operating Conditions’’ table will define
the conditions for actual device operation.
Recommended Operating Conditions
Symbol Parameter
DM54367
Units
Min Nom Max
V
CC
Supply Voltage 4.5 5 5.5 V
V
IH
High Level Input Voltage 2 V
V
IL
Low Level Input Voltage 0.8 V
I
OH
High Level Output Current
b
2mA
IOLLow Level Output Current 32 mA
T
A
Free Air Operating Temperature
b
55 125
§
C
Electrical Characteristics over recommended operating free air temperature range (unless otherwise noted)
Symbol Parameter Conditions Min
Typ
Max Units
(Note 1)
V
I
Input Clamp Voltage V
CC
e
Min, I
I
eb
12 mA
b
1.5 V
V
OH
High Level Output V
CC
e
Min, I
OH
e
Max
2.4 3.1 V
Voltage V
IL
e
Max, V
IH
e
Min
V
OL
Low Level Output V
CC
e
Min, I
OL
e
Max
0.2 0.4 V
Voltage V
IH
e
Min, V
IL
e
Max
I
I
Input Current@Max V
CC
e
Max, V
I
e
5.5V
1mA
Input Voltage
I
IH
High Level Input Current V
CC
e
Max, V
I
e
2.4V 40 mA
I
IL
Low Level Input V
CC
e
Max A
b
40
Current V
I
e
0.5V (Note 4)
V
CC
e
Max A
b
1.6 mA
V
I
e
0.4V (Note 5)
V
CC
e
Max G
b
1.6
V
I
e
0.4V
I
OZH
Off-State Output Current V
CC
e
Max, V
O
e
2.4V
with High Level Output V
IH
e
Min, V
IL
e
Max 40 mA
Voltage Applied
I
OZL
Off-State Output Current V
CC
e
Max, V
O
e
0.4V
with Low Level Output V
IH
e
Min, V
IL
e
Max
b
40 mA
Voltage Applied
I
OS
Short Circuit Output Current V
CC
e
Max (Note 2)
b
40
b
115 mA
I
CC
Supply Current V
CC
e
Max (Note 3) 65 85 mA
Note 1: All typicals are at V
CC
e
5V, T
A
e
25§C.
Note 2: Not more than one output should be shorted at a time.
Note 3: I
CC
is measured with the data inputs grounded and the output controls at 4.5V.
Note 4: Both G
inputs are at 2V.
Note 5: Both G
inputs are at 0.4V.
2