MX 585 MULTI
EXTRACTOR
220-240V
EU & UK
INFORMATION
&
OPERATING
INSTRUCTIONS
CAUTION: DO NOT OPERATE MACHINE UNTIL YOU HAVE READ
ALL SECTIONS OF THIS INSTRUCTION MANUAL
IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY
1. Always use a defoamer when foaming occurs to prevent vacuum motor damage.
2. Connect the machine to a properly grounded outlet.
3. Keep machine from rain, snow , and extremes in temperatures. Store the machine in a
heated location. Use the machine indoors. Do not use outdoors.
4. Use approved chemicals only. NO SOLVENTS.
5. Never use water above 54° C/130° F in the solution tank.
6. Never turn on the solution pump without your solution line connected to the machine
and the tool.
1
8-1-2010
IMPORTANT SAFETY INSTRUCTIONS
TheMX 585 MUL TIis only suitable f or commercial use, for example in hotels, schools, hospitals, f actories,
shops, and offi ces. TheMX 585 MULTI is not intended for normal residential housekeeping purposes.
NOTE: Read all instructions before using this machine.
When using any electrical appliance, basic precautions should always be followed, including the following
warnings:
WARNING!
To reduce the risk of fi re, electric shock, or injury:
• Do not leave the machine unattended when it is plugged in. Unplug the unit from the outlet when
not in use and before servicing.
• Never turn on the solution pump without fi rst connecting either the priming hose or your solution
hose to your machine and to your tool.
• Always turn off the pump and release the pressure in the pump before disconnecting hoses
• To avoid electric shock, do not expose to rain or snow. Use and store indoors.
• Always use solution with a pH between 5 and 10
• Do not allow to be used as a toy. Close attention is necessary when used near children.
• Use only as described in this manual. Use only the manufacturer’s recommended attachments.
• Never add water over 54 °C/130 °F to the solution tank.
• Do not use with damaged cord or plug. If the machine is not working as it should, has been dropped,
damaged, left outdoors or dropped into water, return it to a service center.
• Do not pull by the cord, use the cord as a handle, close a door on the cord, or pull the cord around
sharp edges or corners. Do not run the machine over the cord. Keep the cord away from heated
surfaces. To unplug, grasp the plug, not the cord.
• Do not handle the plug, the cord, or the machine with wet hands.
• Extension cords must be 12/3 and no longer than 50 feet. Replace the cord or unplug immediately
if the ground prong becomes damaged.
• Do not put any object into openings. Do not use with any opening blocked; keep free of dust, lint,
hair, and anything that may reduce air fl ow.
• Keep loose clothing, hair, fi ngers, and all parts of body away from openings and moving parts.
• Do not pick up anything that is burning or smoking, such as cigarettes, matches, hot ashes, or any
health endangering dusts. Do not use to pick up fl ammable or combustible liquids such as gasoline
or use in areas where these liquids may be present.
• Turn off all controls before unplugging.
• Use extra care when cleaning on stairs.
• Connect to a properly grounded outlet only.
• Liquid ejected at the spray nozzle could be dangerous as a result of its temperature, pressure, or
chemical content.
2
INSPECTION:
Carefully unpack and inspect your MX 585 MULTI for shipping damage. Each machine is tested and inspected before shipping. Any shipping damage incurred is the responsibility of the carrier. You should
notify the carrier immediately if you notice damage to the box, the machine, or its parts.
CLEANING SOLUTIONS:
We recommend liquid cleaning chemicals. Powder chemicals may be used, but unless mixed very thoroughly they could cause a build-up in the pump, lines, and quick disconnects. Any problem caused by a
chemical build-up is not covered by warranty. Use a neutral cleaner with a pH between 5 and 10 to avoid
premature wear of the pump, seals, and/or other components. It is a good idea to test an inconspicuous
area of the fl oor .
DANGER: DO NOT USE SOLVENTS, OR ANY CHEMICALS THAT MAY BE
FLAMMABLE, EXPLOSIVE OR COMBUSTIBLE.
MAINTENANCE:
For optimum performance fl ush the machine with clear water at the end of each working day. Once a
month, minimum, run a fl ushing compound through the machine to break up any mineral or chemical
build-up that may have formed. The vacuum motor and the pump do not require any scheduled maintenance; however, the motor may require replacement brushes after 1000 - 1500 hours. Clean the body
with an all-purpose detergent, and protect it with an automobile interior polish. Lubricate the wheels,
castors, and quick disconnects with an all purpose silicone spray.
PARTS AND SERVICE:
Repairs, when required, should be performed by your authorized distributor who maintains an inventory
of original replacement parts and accessories. Call the distributor from whom you purchased this machine
if you need parts or service. Be sure to specify the machine model. Have your serial number handy.
Serial Number: __________________
Model: MX 585 MULTIPurchase Date:__________________
Write the name and phone number of your distributor:
_____________________________________________
_____________________________________________
(and be sure to register your purchase to active your warranty)
3