Nikon Nuvis 60, Nuvis 60 QD Instruction Manual

Nikon Nuvis 60
ADVANCER)
/ \ PHOTO 5Y5TEMI •*TH
Instruction Manual Manual de instrucciones
Nuvis
60QD
No reproduction in any form of this manual, in whole or in part (except for brief quotation in critical articles or reviews), may be made without written authorisation from NIKON CORPORATION.
Queda prohibida la reproduccion total o parcial de este manual (salvo en lo que se refiere a citas breves en articulos o revistas especializadas), sin la autohzacion escrita de NIKON CORPORATION.
NIKON CORPORATION
FUJI BLDG., 2 3. MARUNOUCHI 3-CHOME, CHIYODA-KU. TOKYO 100. JAPAN PHONE: 81-3-3214-5311 TELEX: NIKON J22601 FAX: 81 3-3201-5856
Nikon
ENGLISH
J
FOREWORD
Thank you for purchasing the Nikon Nuvis 60/60 QD. This compact camera employs the Advanced Photo System (IX240 System). To obtain the best results from your new camera, be sure to read through this instruction manual thoroughly.
Note:
Before using your camera on an important occasion such as a wedding or holiday, take some trial shots to familiarize
yourself with all of its features. Nikon cannot be held responsible for malfunctions caused by using the Nuvis 60/60 QD in ways not specified in this manual.
CAMERA PARTS
(Nuvis 60 QD) © Shutter-release button © Zoom switch © Mid-roll rewind button © Lock-release lever ©Strap slot © Red-eye reduction lamp/self-timer
indicator lamp
® Top
LCD
panel
© Auto exposure metering window
® Self-timer button ® Flash mode/red-eye reduction button © Power switch @ Flash ® Viewfinder window ® Autofocus window ®
Lens
cover
®
Green
flash-ready/in-focus LED
@ Viewfinder eyepiece
©
CHP
selector ® Cartridge chamber cover @ Tripod socket
® Battery chamber cover @ Date/time battery cover © Rear
LCD
panel (Nuvis 60 @ Mode button (Nuvis 60 @ Select button (Nuvis 60 @ Set button (Nuvis 60
QD
(Nuvis
60
QD
only)
QD
only)
QD
only)
QD
only)
only) _
© ®®@®Cii;@
(1) TOP LCD PANEL
rT]
i) Red-eye reduction indicator
2) Self-timer indicator
3) Frame counter
4) Insufficient battery power indicator
D Cartridge indicator
1) Flash mode indicator
(2) REAR LCD PANEL (NUVIS 60 QD ONLY)
© Month indicator © Year indicator @ Time indicator colon ® Data imprinting indicator
(3) VIEWFINDER
The viewfinder indicates the boundaries of the current print type.
@ Frame boundary markings (D Autofocus frame marks ^^^^^^^^
IX240 FILM CARTRIDGE
The Nuvis 60/60 QD accepts only fresh IX240 film cartridges. (Conventional 35-mm film cannot be used.) Before loading the cartridge, check the VEI shows "•".
IX240 film cartridges do not have film leader. The film is automatically extracted and wound on inside the camera.
Visual Exposure Indication (VEI)
"•" = Unexposed "»"
= Partially exposed "X" = Fully exposed but not processed "•" = Processed film inside cartridge
(1)
(2) © CD © ©
© ©
880888
(3)
© ©
lE§
Cartridge Spool
Lightlock
Door
Lightlock
Door Drive
PREPARATIONS
O ATTACHING THE STRAP
Slide the strap through the slot as shown.
0 INSERTING THE BATTERY
Open the battery chamber cover by inserting a coin into a slit and lever up.
Insert a 3 V lithium battery (CR2) with the + and - poles aligned as shown. Push the battery chamber cover firmly until it clicks shut.
CHECKING BATTERY LEVEL
Turn the camera on by pressing the power switch. If "0" is blinking on the top LCD panel, replace the battery
as soon as possible. If the top LCD panel remains blank, the battery is
exhausted or not installed properly. led properl
El
LOADING THE FILM O Turn the camera on. Check that "E" blinks and "Q"
is not displayed on the top LCD panel, then open the cartridge chamber cover using the lock-release lever.
0 Insert a new cartridge, and push the cartridge chamber cover until it clicks shut. The film advances to the first frame.
Note:
Film speed is set automatically.
The top LCD panel displays "Q" and the remaining frame count. (If the film is partially or fully will blink until the cartridge is removed.)
Note:
Do not use a cartridge showing
Do not attempt to open the cover while a film is still loaded.
exposed,
"I"
or "•".
"5"'"
SETTING THE DATE AND TIME (NUVIS 60 QD ONLY)
Set
the
date
and
time using
the
SELECT and
1.
Choose Year/Month/Day display to set data. (Choose
Day/Hour/Minute display to set time.)
2.
Push SELECT button so the year starts blinking
indicating that it can be adjusted. Push SET button to set the year.
3. Set the month and the day in the same manner as for the year.
4.
To leave adjust mode, push SELECT button while the
day display is blinking. The newly adjusted data and data imprint indicator"-" appears without blinking.
SET
buttons.
wmmm
ABOUT 1X240 FILM CARTRIDGE
Do not disassemble the cartridge or subject it to shock or
vibration.
Do not soil or damage the data disk of the cartridge. This
can affect the data transfer.
Do not attempt to open the Lightlock Door Drive. This may expose the
Do not break the Irreversible Processed Indicator (IPI) on
the cartridge. This may prevent processing and printing.
Consult your photo lab if the IPI is broken.
Do not attempt to rotate the Cartridge Spool with a screwdriver or a pointed object. This can expose the alter the
Do not store cartridges:
• In direct sunlight, near heating appliances
• In dirty or dusty conditions
• In hot or humid conditions conductive to mold
• Near strong magnetic fields
film.
VEI,
and prevent processing.
film,
^
SELECT
0
-['ss'-
PROCESSING AND PRINTING
For best results, take film cartridges for processing and printing to photo labs displaying this Authorized Photo Lab Mark
sign.
Authorized Photo Labs offer the following processing services:
• Three different print types (C, H and P)
• Index prints (mini-prints of all frames on a single sheet)
• Negatives Returned in Cartridge (NRIC): negatives are returned inside the original cartridge for easy storage.
Your Authorized Photo Lab will be happy to supply further information.
SET
e g
J J
%
I
W1 _V| * i
3
' " i" '
'3"!
1 -}!
3 i (10
:-
1
DATA IMPRINT FUNCTION (NUVIS 60 QD ONLY)
The rear LCD panel displays the date/time imprint as it will appear on photographs. (The date/time cannot be imprinted on
Press MODE to select the desired date/time imprint format.
Date/time will be imprinted as shown on the right. The rear LCD panel displays"-" to indicate that the date/
time will be imprinted.
REPLACING THE DATE/TIME BATTERY WHEN IMPRINTED DATA IS DIM OR ILLEGIBLE
Using a screwdriver, remove the date/time battery cover. Insert a fresh lithium 3 V CR2025 battery with the + side facing upward. Replace the cover and secure firmly with the set screw.
Note:
P-type
photographs.)
Remember to reset the date and time.
BASIC OPERATION
O Turn the camera on and hold the camera steady with both hands. Ensure that the lens, flash and autofocus windows are not obstructed by fingers, hair or the camera strap.
Note:
When taking vertical photographs, hold the camera with the
flash at the top.
© Look through the viewfinder and frame your picture with the subject covering the autofocus frame marks "o".
© Lightly press the shutter-release button to focus the subject. The green LED lights up when correct focus is achieved.
Note:
The shutter-release button locks while the flash is recharging.
Note:
Minimum focusing distance = approx. 1.0 m/3.3 ft (at
wideangle setting), or approx. 1.2 m/3.9 ft (at telephoto setting).
© Fully Depress the shutter-release button to release the shutter. The flash fires automatically if available light is insufficient. The film advances to the next frame and the remaining frame count on the top LCD panel falls by one.
r
35
! IJ?5
*
t i
cz
1 i
o
i
-1
'35
Wj
Year/month/day
Day/hour/minute
No imprint display
Month/day/year
Day/month/year
O PRINT TYPE
Use the CHP selector to choose between C, H and P print types.
Caution:
Hold the camera away from your face when
using the CHP selector.
Print type can be changed at any time.
©ZOOM
Press W (Wide) to expand the view for landscapes and group portraits. Press T (Telephoto) to make distant subjects appear closer.
Note:
When the camera is not used for more than 3
minutes, the power automatically shuts OFF and the lens retracts to the original position.
Caution:
During this operation, take care not to pinch
your
skin.
ADVANCED FUNCTIONS
O FLASH MODE/RED-EYE REDUCTION
BUTTON
Press "V button to cycle through the following modes:
Auto flash X
i
Red-eye reduction
Anytime flash i
Flash-cancel @
© SELF-TIMER BUTTON
Press "&" button to display on LCD.
,u
I
^•©>
CCBO)
CHP
Type and aspect ratio [Vertical: Horizontal)
Wide-vison (H) type 9:16
Panorama (P) type 1
:3
AUTO FLASH
The autoflash symbol "Jf0" on the top LCD panel
indicates that the flash will fire automatically if available light is insufficient.
Note:
Ensure that the subject is within the flash shooting
range.
Flash shooting range (ISO 200)
Wideangle (25 mm): 1.0 m-4.7 m (3.3 ft—15.4 ft) Telephoto (50 mm): 1.2 m-2.5 m (3.9 ft—8.2 ft)
Note:
The flash takes about 6 seconds to recharge. The
shutter-release button locks while the flash is recharging.
O RED-EYE REDUCTION
Flash photography sometimes causes the pupils of the eyes to appear bright red in photographs. The red-eye reduction lamp on the camera face lights up for about one second before the flash fires to help reduce this effect.
Red-eyes reduction mode is indicated by LCD panel.
Note:
Keep your finger firmly on the shutter-release
button until the shutter is released.
© SELF-TIMER
Self-timer mode is indicated by "c5" on the top LCD panel.
To start the timer, depress the shutter-release button fully. The indicator lamp on the camera face blinks for 10 seconds before the shutter is released.
Note:
Self-timer mode is canceled automatically after
use.
To cancel self-timer mode manually, switch
the camera off.
"J|J"
on the top
AUTO
USING FOCUS LOCK O When the subject does not cover the autofocus frame
marks "o", the camera may focus on the background instead.
© Position the autofocus frame marks directly on the subject and lightly press the shutter-release button. The green LED lights up and the focus is locked at this distance. Keeping your finger on the shutter-release button,
recompose the original scene. Now depress fully
to release the shutter.
Note:
Autofocus may not focus properly on:
• Small subjects that do not cover the autofocus frame marks
• Dark subjects with no reflection
• Glossy or reflective surfaces
• Non-solid subjects
• The main subject when there is a closer secondary subject
Use focus lock to focus on another subject the same
distance from the camera.
O FLASH-CANCEL
Flash-cancel mode allows you to shoot without flash in low-light situations where the flash would normally fire. Use flash-cancel mode in art galleries and other places where flash photography is prohibited
Flash-cancel mode is indicated by "(§)" on the top LCD panel.
Note:
Flash-cancel mode uses a slower shutter speed.
For best results, place the camera on a tripod or other stable surface.
©ANYTIME FLASH
Anytime flash mode allows you to use the flash in situations where the flash would not normally fire, for
instance when the subject is standing in the shade or in
front of the sun. Anytime flash mode is indicated by "J" on the top LCD
panel.
(e.g.,
(e.g.,
flames, fireworks)
water, car panels)
•*
».?S
AT THE END OF THE FILM
The film rewinds automatically at the end of the
Rewinding is complete when the "C" blinks on the top LCD panel.
Turn the camera upside-down and open the cartridge
chamber cover. Gently remove the cartridge
To rewind the film before the end of the
mid-roll rewind button with a sharp object, such as a ball-point pen.
Note:
A film cartridge cannot be reused after being
rewound mid-roll.
Note:
The battery can be replaced if necessary while
the film is still rewinding. Rewinding will resume when the new battery is inserted.
CAMERA CARE TIPS
Always turn
Avoid extremely hot conditions.
Allow
For
The
The camera
Protect the camera from foreign matter such
Use a blower
Never use thinner, benzene,
off
the
accidental shutter release and associated battery drain.
a car,
on the
the Intensive flash use can generate heat in the battery and camera itself.
optimum performance 32°F), keep pocket.
camera
damaged the beach
come into contact with water, wipe immediately with a soft, cloth.
dust. Wipe clean using a soft, from
the
camera.
camera when
beach
or
camera
to
the
camera
is a
precision mechanism,
if
hit or
dropped.
is not
waterproof. Keep
and
never submerge
to
remove dust from
lens using a soft cloth.
not in use.
Do not near a heater. cool
in a warm place such
leave the camera inside
off
after continuous flash firing.
at
low
temperatures (below
and can be
it
away from sea spray
it
in
water. Should
dry
cloth.
the
lens. Clean stubborn dirt
or
other active agents
roll,
push the
This prevents
as
inside yeur
seriously
the
camera
as
salt, sand
to
clean
roll.
0°C/
at
dry
and
the
n
u
Store
in a
cool,
dry
place
to chemicals such as camphor and naphthalene. For best results, store together with a desiccating agent.
When the camera
occasionally and release
BATTERIES
Battery power may weaken when the temperature drops below
0°C732°F
but
temperature.
Do not
circuit, disassemble
Keep batteries
FOR CANADA
This digital apparatus does radio noise emissions from digital apparatus Interference Regulations Communications.
will recover
throw used batteries into
out of
prevent mold, well away from
is not
used
tor
a prolonged period, take
the
shutter and fire
as the
heat batteries.
reach
of
small children.
not
exceed
of
the
the
Canadian Department
or
it out
the
flash.
camera reaches normal
fire,
or
attempt
to
short
the
(Class
B)
limits
set out in the
for
Radio
of
SPECIFICATIONS
Camera type: IX240 (Advanced Photo System) type autofocus lens-
Film type: IX24D (Advanced Photo System) film cartridge (16.7
Print type: Choice of C, H and P type Lens:
25 mm F5-50 mm F9.5 lens
Shutter: Programmed electronic shutter {shutter speed: 1/90
Focusing:
inlrared-active autofocus system (activated by pressing
Viewfinder: Albada-bright frame zoom viewfinder, Framecoverage
Viewfinderdisplay: Slide C/H/P selector to choose between C, H and P-
Film speed: For
Film loading: Drop-in loading system with Double Exposure
Winder mechanism: Spool drive system with automatic frame advance,
shutter camera with Nikon Zoom lens
mm x 30.2 mm)
(31
35-mm
type);
5 elements in 5 groups
and 1/300 sec, fixed diaphragm)
shutter-release button lightly); effective from 1.0 m/3.3 ft to inlinity (at wideangle setting), or from 1.2 to infinity (at telephoto setting); focus remains locked while shutter-release button lightly depressed
= approx. 85% for
Magnification = approx. 0.31x at 25 mm, approx
0.59xat50 mm
type;
center autofocus frame marks
ISO
200 and 400
Other film speeds are rounded off fo ISO 200 or 400.
Prevention (DEP); film automatically wound on to the
first frame after loading
automatic rewind at end of
facility
-62 mm converted to
C,
H and P type printed image area,
film,
film speed is set automatically.
roll,
and mid-roll rewind
m/3.9ft
Frame counter: Seif-timer:
d-eye reduction:
Hery life:
Power source: Date/time imprint (Nuvis 50 QD only):
Dimensions (W x H x D):
Weight (without batteries): Nuvis 60: Approx. 200 g, Nuvis 60 QD: Approx. 210 g All specifications apply when using the camera with a fresh battery at normal temperature (20CC/68°F). Specifications and design are subject to change withoul notice.
Top LCD panel slows number of frames remaining Electronic self-timer activated by pressing shutter­release button; indicator lamp blinks for 10 seconds before shutter is released Three flash modes (auto flash, flash-cancel, and anytime flash); guide number 14 (ISO 200 in meter); shutter-release button locks while recharging; recycling time = 6 seconds approx. Flash range for ISO 200
15.4 ft) (25 mm); approx. mm| Lamp on camera face lights up for approx. 1 second before flash fires Approx. 16 rolls of 25-exposure film (with 50% flash
One 3 V lithium battery (CR2) Rear
LCD day, month/day/year, day/month/year, day/hour/minute or no imprint); built-in 24-hour clock accurate to ±90 seconds per month; months and leap years programmed up to 2019; requires one 3 V lithium battery (CR2025); battery lasts approx. 4 years
Nuvis 60: Approx. 115 mm x 63 mm K 40 mm (Approx.
3.8 in x 2,1 in x 1,6 in), Nuvis 60 QD: Approx. 115 mm x 63 mm x 44 mm (Approx. 3,8 in x 2,1 in x 1,7 in)
film:
approx.
1.0-4.7
1,2-2.5
panel displays date/time format (year/month/
m (3.3-
m [3.9-8.2 ft) [50
Loading...
+ 1 hidden pages