NETGEAR GSM7228PS-100NAS User Manual

ProSafe Managed Switch

Command Line Interface (CLI) User Manual
10.0 GSM7328Sv2 GSM7352Sv2 GSM7228PS GSM7252PS M5300-28G3
M5300-52G3 M5300-28G-POE+ M5300-52G-POE+ M5300-28GF3 M5300-28G M5300-52G
350 East Plumeria Drive San Jose, CA 95134 USA
November 2012 202-11054-02
1.0
ProSafe Managed Switch
© 2012 NETGEAR, Inc. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated
into any language in any form or by any means without the written permission of NETGEAR, Inc.
Technical Support
Thank you for choosing NETGEAR. To register your product, get the latest product updates, or get support online, visit us at http://support.netgear.com.
Phone (US & Canada only): 1-888-NETGEAR Phone (Other Countries): See Support information card.
Trademarks
NETGEAR, the NETGEAR logo, ReadyNAS, ProSafe, Smart Wizard, Auto Uplink, X-RAID2, and NeoTV are trademarks or registered trademarks of NETGEAR, Inc. Microsoft, Windows, Windows NT, and Vista are registered trademarks of Microsoft Corporation. Other brand and product names are registered trademarks or trademarks of their respective holders.
Statement of Conditions
To improve internal design, operational function, and/or reliability, NETGEAR reserves the right to make changes to the products described in this document without notice. NETGEAR does not assume any liability that may occur due to the use, or application of, the product(s) or circuit layout(s) described herein.
Revision History
Publication Part Number
202-11054-02 1.0 November 2012 Added mixed stacking commands. 202-11054-01 1.0 August 2012 Replaced the private group commands with
202-10936-02 1.0 January 2012 Added clear event log, ip local-proxy-arp, and
202-10936-01 1.0 November 2011 Added PoE and MVR mode features. 202-10515-05 1.1 June 2011 Added DHCPv6 and DHCPv6 mode features. 202-10515-04 1.0 November 2010 New document template. 202-10515-03 v 1.0 June 2010 Move some content to the Software Setup
202-10515-02 Software release 8.0.2: new firmware with
Version Publish Date Comments
private VLAN commands, replaced the Auto-Voice over IP Commands chapter, and added iSCSI commands.
spanning-tree auto-edge. Removed poe reset auto.
Guide.
DHCP L3 Relay, color conform policy, DHCP server in dynamic mode, and configuring a stacking port as an Ethernet port.
202-10515-01 Original publication.
2

Contents

Chapter 1 Using the Command-Line Interface
Chapter 2 Stacking Commands
Licensing and Command Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Command Syntax. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Command Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Common Parameter Values. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Unit/Slot/Port Naming Convention . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Using a Command’s “No” Form . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Managed Switch Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Command Modes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Command Completion and Abbreviation . . . . . . . . . . . . . . . . . . . . . . . . . .17
CLI Error Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
CLI Line-Editing Conventions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Using CLI Help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Accessing the CLI. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Dedicated Port Stacking. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Stacking Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
Non-Stop Forwarding Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
Stack Firmware Synchronization Commands. . . . . . . . . . . . . . . . . . . . . . .35
Chapter 3 Switching Commands
Port Configuration Commands. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39
Loopback Interface Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45
Spanning Tree Protocol (STP) Commands . . . . . . . . . . . . . . . . . . . . . . . .47
VLAN Commands. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64
Double VLAN Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .77
Voice VLAN Commands. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .80
Provisioning (IEEE 802.1p) Commands. . . . . . . . . . . . . . . . . . . . . . . . . . .82
Protected Ports Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .82
Private Group Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .85
Private VLAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .86
GARP Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .90
GVRP Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92
GMRP Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .94
Port-Based Network Access Control Commands. . . . . . . . . . . . . . . . . . . .96
802.1X Supplicant Commands. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .109
Storm-Control Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .112
Flow Control Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .122
3
ProSafe Managed Switch
Port-Channel/LAG (802.3ad) Commands . . . . . . . . . . . . . . . . . . . . . . . .123
Port Mirroring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .139
Static MAC Filtering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .141
DHCP L2 Relay Agent Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . .145
DHCP Client Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .149
DHCP Snooping Configuration Commands. . . . . . . . . . . . . . . . . . . . . . .150
Dynamic ARP Inspection Commands . . . . . . . . . . . . . . . . . . . . . . . . . . .159
IGMP Snooping Configuration Commands . . . . . . . . . . . . . . . . . . . . . . .166
IGMP Snooping Querier Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . .177
MLD Snooping Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .180
MLD Snooping Querier Commands. . . . . . . . . . . . . . . . . . . . . . . . . . . . .187
set mld querier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .187
set mld querier query_interval . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .188
set mld querier timer expiry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .188
set mld querier election participate. . . . . . . . . . . . . . . . . . . . . . . . . . . .189
show mldsnooping querier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .189
Port Security Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .190
LLDP (802.1AB) Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .194
LLDP-MED Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .203
Denial of Service Commands. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .212
MAC Database Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .222
ISDP Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .224
Priority-Based Flow Control Commands . . . . . . . . . . . . . . . . . . . . . . . . .229
Chapter 4 Multicast VLAN Registration (MVR)
About MVR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .232
MVR Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .232
Chapter 5 Routing Commands
Address Resolution Protocol (ARP) Commands . . . . . . . . . . . . . . . . . . .240
IP Routing Commands. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .246
Router Discovery Protocol Commands . . . . . . . . . . . . . . . . . . . . . . . . . .263
Virtual LAN Routing Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .266
Virtual Router Redundancy Protocol Commands. . . . . . . . . . . . . . . . . . .267
DHCP and BOOTP Relay Commands. . . . . . . . . . . . . . . . . . . . . . . . . . .276
IP Helper Commands. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .278
Open Shortest Path First (OSPF) Commands . . . . . . . . . . . . . . . . . . . . .282
OSPF Graceful Restart Commands. . . . . . . . . . . . . . . . . . . . . . . . . . . . .322
nsf. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .323
nsf restart-interval. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .323
nsf helper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .324
nsf helper disable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 325
nsf [ietf] helper strict-lsa-checking . . . . . . . . . . . . . . . . . . . . . . . . . . . .325
OSPF Interface Flap Dampening Commands . . . . . . . . . . . . . . . . . . . . .327
Routing Information Protocol (RIP) Commands. . . . . . . . . . . . . . . . . . . .329
ICMP Throttling Commands. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .336
4
ProSafe Managed Switch
Chapter 6 IP Multicast Commands
Multicast Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .339
DVMRP Commands. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .344
PIM Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .349
Internet Group Message Protocol (IGMP) Commands. . . . . . . . . . . . . . .360
IGMP Proxy Commands. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .367
Chapter 7 IPv6 Commands
Tunnel Interface Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .373
IPv6 Routing Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .375
OSPFv3 Commands. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .398
OSPFv3 Graceful Restart Commands . . . . . . . . . . . . . . . . . . . . . . . . . . .429
DHCPv6 Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .431
Chapter 8 IPv6 Multicast Commands
IPv6 Multicast Forwarder Commands . . . . . . . . . . . . . . . . . . . . . . . . . . .439
IPv6 PIM Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .442
IPv6 MLD Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .449
IPv6 MLD-Proxy Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .455
Chapter 9 Quality of Service (QoS) Commands
Class of Service (CoS) Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . .461
Differentiated Services (DiffServ) Commands . . . . . . . . . . . . . . . . . . . . .469
DiffServ Class Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .470
DiffServ Policy Commands. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .479
DiffServ Service Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .484
DiffServ Show Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .485
MAC Access Control List (ACL) Commands . . . . . . . . . . . . . . . . . . . . . .491
IP Access Control List (ACL) Commands. . . . . . . . . . . . . . . . . . . . . . . . .495
IPv6 Access Control List (ACL) Commands. . . . . . . . . . . . . . . . . . . . . . .502
Time Range Commands for Time-Based ACLs. . . . . . . . . . . . . . . . . . . .506
AutoVOIP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .508
iSCSI Commands. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .512
Chapter 10 Power over Ethernet (PoE) Commands
About PoE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .518
PoE Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .519
Chapter 11 Utility Commands
Auto Install Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .530
Dual Image Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .532
System Information and Statistics Commands. . . . . . . . . . . . . . . . . . . . .534
Logging Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .550
Email Alerting and Mail Server Commands . . . . . . . . . . . . . . . . . . . . . . .556
5
ProSafe Managed Switch
System Utility and Clear Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . .562
Simple Network Time Protocol (SNTP) Commands. . . . . . . . . . . . . . . . .572
DHCP Server Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .579
DNS Client Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .591
Packet Capture Commands. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .595
Serviceability Packet Tracing Commands . . . . . . . . . . . . . . . . . . . . . . . .598
Cable Test Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .617
sFlow Commands. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .617
Software License Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .622
IP Address Conflict Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .623
Link Local Protocol Filtering Commands . . . . . . . . . . . . . . . . . . . . . . . . .624
RMON Stats and History Commands. . . . . . . . . . . . . . . . . . . . . . . . . . . .625
UDLD Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .631
Chapter 12 Management Commands
Configuring the Switch Management CPU. . . . . . . . . . . . . . . . . . . . . . . .636
Network Interface Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .638
Console Port Access Commands. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .641
Telnet Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .643
Secure Shell (SSH) Commands. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .648
Management Security Commands. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .651
Hypertext Transfer Protocol (HTTP) Commands . . . . . . . . . . . . . . . . . . .652
Access Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .659
User Account Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .659
SNMP Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .683
RADIUS Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .694
TACACS+ Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 706
Configuration Scripting Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . .711
Pre-Login Banner and System Prompt Commands. . . . . . . . . . . . . . . . .713
Switch Database Management (SDM) Templates. . . . . . . . . . . . . . . . . .714
IPv6 Management Commands. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .716
Chapter 13 Log Messages
Core . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .722
Utilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .724
Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .726
Switching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .730
QoS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .736
Routing/IPv6 Routing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .737
Multicast. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .740
Stacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .742
Technologies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .743
O/S Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .745
Chapter 14 Captive Portal Commands
Captive Portal Global Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .747
6
ProSafe Managed Switch
Captive Portal Configuration Commands. . . . . . . . . . . . . . . . . . . . . . . . .751
Captive Portal Status Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .757
Captive Portal Client Connection Commands . . . . . . . . . . . . . . . . . . . . .761
Captive Portal Interface Commands. . . . . . . . . . . . . . . . . . . . . . . . . . . . .765
Captive Portal Local User Commands . . . . . . . . . . . . . . . . . . . . . . . . . . .766
Captive Portal User Group Commands . . . . . . . . . . . . . . . . . . . . . . . . . .772
Chapter 15 Command List Index
7

1. Using the Command-Line Interface

The command-line interface (CLI) is a text-based way to manage and monitor the system. You can access the CLI by using a direct serial connection or by using a remote logical connection with telnet or SSH.
This chapter describes the CLI syntax, conventions, and modes. It contains the following sections:
Licensing and Command Support
Command Syntax
Command Conventions
Common Parameter Values
Unit/Slot/Port Naming Convention
Using a Command’s “No” Form
Managed Switch Modules
Command Modes
Command Completion and Abbreviation
CLI Error Messages
CLI Line-Editing Conventions
Using CLI Help
Accessing the CLI
1

Licensing and Command Support

As shown in the following table, some command groups or commands require a license and some are supported on particular switch models. For those requiring a license, license keys are available from your VAR or NETGEAR authorized e-commerce portal. License activation is described in the Software Setup Manual.
8
ProSafe Managed Switch
Command Group or Command
Stacking Commands Supported Supported Supported Supported Supported Non-Stop Forwarding
Commands Stack Firmware
Synchronization Commands
Router Discovery Protocol Commands
Virtual Router Redundancy Protocol Commands
Open Shortest Path First (OSPF) Commands
OSPF Graceful Restart Commands
Routing Information Protocol (RIP) Commands
Tunnel Interface Commands
M5300-28G-POE+ M5300-52G-POE+
Supported Supported Supported Supported Supported
Supported Supported Supported Supported Supported
Require license Require license Supported Supported Require license
Require license Require license Supported Supported Require license
Require license Require license Supported Supported Require license
Require license Require license Supported Supported Require license
Require license Require license Supported Supported Require license
Require license Require license Supported Supported Require license
M5300-28G M5300-52G
M5300-28G3 M5300-52G3 M5300-28GF3
GSM7328Sv2 GSM7352Sv2
GSM7228PS GSM7252PS
IPv6 Routing Commands Require license Require license Supported Supported Require license OSPFv3 Commands Require license Require license Supported Supported Require license OSPFv3 Graceful Restart
Commands DHCPv6 Commands Require license Require license Supported Supported Require license Multicast Commands Require license Require license Supported Supported Require license DVMRP Commands Require license Require license Supported Supported Require license PIM Commands Require license Require license Supported Supported Require license Internet Group Message
Protocol (IGMP) Commands
IGMP Proxy Commands Require license Require license Supported Supported Require license IPv6 Multicast Forwarder
Commands IPv6 PIM Commands Require license Require license Supported Supported Require license IPv6 MLD Commands Require license Require license Supported Supported Require license
Require license Require license Supported Supported Require license
Require license Require license Supported Supported Require license
Require license Require license Supported Supported Require license
Using the Command-Line Interface
9
ProSafe Managed Switch
Command Group or Command
IPv6 MLD-Proxy Commands
PoE Commands Supported Not Supported Not Supported Not Supported Supported MVR Commands Supported Supported Supported Not Supported Not Supported Link Local Protocol Filtering
Commands Priority-Based Flow Control
Commands Captive Portal Commands Supported Supported Supported Supported Supported cos-queue random-detect Supported Supported Supported Supported Supported no cos-queue
random-detect random-detect exponential
weighting-constant no random-detect
exponential weighting-constant
M5300-28G-POE+ M5300-52G-POE+
Require license Require license Supported Supported Require license
Supported Supported Supported Supported Supported
Not Supported Not Supported Not Supported Not Supported Not Supported
Supported Supported Supported Supported Supported
Supported Supported Supported Supported Supported
Supported Supported Supported Supported Supported
M5300-28G M5300-52G
M5300-28G3 M5300-52G3 M5300-28GF3
GSM7328Sv2 GSM7352Sv2
GSM7228PS GSM7252PS
random-detect queue-parms
no random-detect queue-parms

Command Syntax

Format network parms <ipaddr> <netmask> [gateway]
Supported Supported Supported Supported Supported
Supported Supported Supported Supported Supported
A command is one or more words that might be followed by one or more parameters. Parameters can be required or optional values.
Some commands, such as show network or clear vlan, do not require parameters. Other commands, such as network parms, require that you supply a value after the command. You must type the parameter values in a specific order, and optional parameters follow required parameters. The following example describes the network parms command syntax:
network parms is the command name.
<ipaddr> and <netmask> are parameters and represent required values that you must
enter after you type the command keywords.
Using the Command-Line Interface
10
ProSafe Managed Switch
[gateway] is an optional parameter, so you are not required to enter a value in place of
the parameter.
The New Template User Manual lists each command by the command name and provides a brief description of the command. Each command reference also contains the following information:
Format shows the command keywords and the required and optional parameters.
Mode identifies the command mode you must be in to access the command.
Default shows the default value, if any, of a configurable setting on the device.
The show commands also contain a description of the information that the command shows.

Command Conventions

In this document, the command name is in bold font. Parameters are in italic font. You must replace the parameter name with an appropriate value, which might be a name or number. Parameters are order dependent.
The parameters for a command might include mandatory values, optional values, or keyword choices. Table 1 describes the conventions this document uses to distinguish between value types.
Table 1. Parameter Conventions
Symbol Example Description
<> angle brackets
[] square brackets Indicates an optional parameter that you can enter in
{} curly braces Indicates that you must select a parameter from the list of
| Vertical bars Separates the mutually exclusive choices. [{}] Braces within
square brackets
<value>
[value]
{choice1 | choice2}
choice1 | choice2
[{choice1 | choice2}]
Indicates that you must enter a value in place of the brackets and text inside them.
place of the brackets and text inside them.
choices.
Indicates a choice within an optional element.

Common Parameter Values

Parameter values might be names (strings) or numbers. To use spaces as part of a name parameter, enclose the name value in double quotes. For example, the expression “System
Using the Command-Line Interface
11
ProSafe Managed Switch
Name with Spaces” forces the system to accept the spaces. Empty strings (““) are not valid user-defined strings. Table 2 describes common parameter values and value formatting.
Table 2. Parameter Descriptions
Parameter Description
ipaddr This parameter is a valid IP address. You can enter the IP address in the following formats:
a (32 bits) a.b (8.24 bits) a.b.c (8.8.16 bits) a.b.c.d (8.8.8.8)
In addition to these formats, the CLI accepts decimal, hexadecimal and octal formats through the following input formats (where n is any valid hexadecimal, octal or decimal number):
0xn (CLI assumes hexadecimal format) 0n (CLI assumes octal format with leading zeros) n (CLI assumes decimal format)
ipv6-address
FE80:0000:0000:0000:020F:24FF:FEBF:DBCB, or FE80:0:0:0:20F:24FF:FEBF:DBCB, or FE80::20F24FF:FEBF:DBCB, or FE80:0:0:0:20F:24FF:128:141:49:32
For additional information, refer to RFC 3513.
Interface or unit/slot/port
Logical Interface
Character strings Use double quotation marks to identify character strings, for example, “System Name with
Valid slot and port number separated by forward slashes. For example, 0/1 represents slot number 0 and port number 1.
Represents a logical slot and port number. This is applicable in the case of a port-channel (LAG). You can use the logical unit/slot/port to configure the port-channel.
Spaces”. An empty string (“”) is not valid.

Unit/Slot/Port Naming Convention

Managed switch software references physical entities such as cards and ports by using a unit/slot/port naming convention. The software also uses this convention to identify certain logical entities, such as Port-Channel interfaces.
The slot number has two uses. In the case of physical ports, it identifies the card containing the ports. In the case of logical and CPU ports it also identifies the type of interface or port.
Table 3. Type of Slots
Slot Type Description
Physical slot numbers Physical slot numbers begin with zero, and are allocated up to the maximum
number of physical slots.
Logical slot numbers Logical slots immediately follow physical slots and identify port-channel (LAG) or
router interfaces.
CPU slot numbers The CPU slots immediately follow the logical slots.
Using the Command-Line Interface
12
ProSafe Managed Switch
The port identifies the specific physical port or logical interface being managed on a given slot.
Table 4. Type of Ports
Port Type Description
Physical Ports The physical ports for each slot are numbered sequentially starting from zero. Logical Interfaces Port-channel or Link Aggregation Group (LAG) interfaces are logical interfaces
that are only used for bridging functions. VLAN routing interfaces are only used for routing functions. Loopback interfaces are logical interfaces that are always up. Tunnel interfaces are logical point-to-point links that carry encapsulated packets.
CPU ports CPU ports are handled by the driver as one or more physical entities located on
physical slots.
Note: In the CLI, loopback and tunnel interfaces do not use the
unit/slot/port format. To specify a loopback interface, you use the loopback ID. To specify a tunnel interface, you use the tunnel ID.

Using a Command’s “No” Form

The no keyword is a specific form of an existing command and does not represent a new or distinct command. Almost every configuration command has a no form. In general, use the no form to reverse the action of a command or reset a value back to the default. For example, the no shutdown configuration command reverses the shutdown of an interface. Use the command without the keyword no to re-enable a disabled feature or to enable a feature that is disabled by default. Only the configuration commands are available in the no form.

Managed Switch Modules

Managed switch software consists of flexible modules that can be applied in various combinations to develop advanced Layer 2/3/4+ products. The commands and command modes available on your switch depend on the installed modules. Additionally, for some show commands, the output fields might change based on the modules included in the software.
The software suite includes the following modules:
Switching (Layer 2)
Routing (Layer 3)
IPv6—IPv6 routing
Multicast
Using the Command-Line Interface
13
ProSafe Managed Switch
Quality of Service
Management (CLI, Web UI, and SNMP)
IPv6 Management—Allows management of the device through an IPv6 through an IPv6
address without requiring the IPv6 Routing package in the system. The management address can be associated with the network port (front-panel switch ports) and a routine interface (port or VLAN).
Stacking
Not all modules are available for all platforms or software releases.

Command Modes

The CLI groups commands into modes according to the command function. Each of the command modes supports specific software commands. The commands in one mode are not available until you switch to that particular mode, with the exception of the User EXEC mode commands. You can execute the User EXEC mode commands in the Privileged EXEC mode.
The command prompt changes in each command mode to help you identify the current mode.
Table 5 describes the command modes and the prompts visible in that mode.
Note: The command modes available on your switch depend on the
software modules that are installed. For example, a switch that does not support BGPv4 does not have the Router BGPv4 Command Mode.
Table 5. CLI Command Modes
Command Mode Prompt Mode Description
User EXEC
Privileged EXEC
Global Config
VLAN Config
Switch>
Switch#
Switch (Config)#
Switch (Vlan)#
Contains a limited set of commands to view basic system information.
Allows you to issue any EXEC command, enter the VLAN mode, or enter the Global Configuration mode.
Groups general setup commands and permits you to make modifications to the running configuration.
Groups all the VLAN commands.
Using the Command-Line Interface
14
ProSafe Managed Switch
Table 5. CLI Command Modes (Continued)
Command Mode Prompt Mode Description
Interface Config Switch (Interface <unit/slot/port>)#
Switch (Interface Loopback <id>)#
Switch (Interface Tunnel <id>)#
Line Config Switch (line)# Contains commands to configure outbound
Policy Map Config
Policy Class Config
Class Map Config Switch (Config-class-map)# Contains the QoS class map configuration
Ipv6_Class-Map Config
Router OSPF Config
Router OSPFv3 Config
Switch (Config-policy-map)# Contains the QoS Policy-Map configuration
Switch (Config-policy-class-map)# Consists of class creation, deletion, and
Switch (Config-class-map)# Contains the QoS class map configuration
Switch (Config-router)# Contains the OSPF configuration commands.
Switch (Config rtr)# Contains the OSPFv3 configuration commands.
Manages the operation of an interface and provides access to the router interface configuration commands.
Use this mode to set up a physical port for a specific logical connection operation.
telnet settings and console interface settings.
commands.
matching commands. The class match commands specify Layer 2, Layer 3, and general match criteria.
commands for IPv4.
commands for IPv6.
Router RIP Config Switch (Config-router)# Contains the RIP configuration commands. MAC Access-list
Config
TACACS Config Switch (Tacacs)# Contains commands to configure properties for
DHCP Pool Config
DHCPv6 Pool Config
Stack Global Config Mode
ARP Access-List Config Mode
Switch (Config-mac-access-list)# Allows you to create a MAC Access-List and to
enter the mode containing MAC Access-List configuration commands.
the TACACS servers.
Switch (Config dhcp-pool)# Contains the DHCP server IP address pool
configuration commands.
Switch (Config dhcp6-pool)# Contains the DHCPv6 server IPv6 address pool
configuration commands.
Switch (Config stack)# Allows you to access the Stack Global Config
Mode.
Switch (Config-arp-access-list)# Contains commands to add ARP ACL rules in
an ARP Access List.
Using the Command-Line Interface
15
ProSafe Managed Switch
Table 6 explains how to enter or exit each mode.
Table 6. CLI Mode Access and Exit
Command Mode Access Method Exit or Access Previous Mode
User EXEC This is the first level of access. To exit, enter logout. Privileged EXEC From the User EXEC mode, enter
enable.
Global Config From the Privileged EXEC mode,
enter configure.
VLAN Config From the Privileged EXEC mode,
enter vlan database.
Interface Config From the Global Config mode,
enter interface <unit/slot/port> or interface loopback <id> or interface tunnel <id>
Line Config From the Global Config mode,
enter lineconfig.
Policy-Map Config
Policy-Class-Map Config
Class-Map Config
From the Global Config mode, enter policy-map <name> in.
From the Policy Map mode enter class.
From the Global Config mode, enter class-map, and specify the optional keyword ipv4 to specify the Layer 3 protocol for this class. See class-map on page 470 for more information.
To exit to the User EXEC mode, enter exit or press Ctrl-Z.
To exit to the Privileged EXEC mode, enter exit, or press Ctrl-Z.
To exit to the Privileged EXEC mode, enter exit, or press Ctrl-Z.
To exit to the Global Config mode, enter exit. To return to the Privileged EXEC mode, enter Ctrl-Z.
To exit to the Global Config mode, enter exit. To return to the Privileged EXEC mode, enter Ctrl-Z.
To exit to the Global Config mode, enter exit. To return to the Privileged EXEC mode, enter Ctrl-Z.
To exit to the Policy Map mode, enter exit. To return to the Privileged EXEC mode, enter Ctrl-Z.
To exit to the Global Config mode, enter exit. To return to the Privileged EXEC mode, enter Ctrl-Z.
Ipv6-Class-Map Config
Router OSPF Config
Router OSPFv3 Config
From the Global Config mode, enter class-map and specify the optional keyword ipv6 to specify the Layer 3 protocol for this class. See class-map on page 470 for more information.
From the Global Config mode, enter router ospf.
From the Global Config mode, enter ipv6 router ospf.
To exit to the Global Config mode, enter exit. To return to the Privileged EXEC mode, enter Ctrl-Z.
To exit to the Global Config mode, enter exit. To return to the Privileged EXEC mode, enter Ctrl-Z.
To exit to the Global Config mode, enter exit. To return to the Privileged EXEC mode, enter Ctrl-Z.
Using the Command-Line Interface
16
ProSafe Managed Switch
Table 6. CLI Mode Access and Exit (Continued)
Command Mode Access Method Exit or Access Previous Mode
Router RIP Config
MAC Access-list Config
TACACS Config From the Global Config mode,
DHCP Pool Config
DHCPv6 Pool Config
Stack Global Config Mode
ARP Access-List Config Mode
From the Global Config mode, enter router rip.
From the Global Config mode, enter
mac access-list extended
<name>.
enter tacacs-server host <ip-addr>, where <ip-addr> is the IP address of the TACACS server on your network.
From the Global Config mode, enter ip dhcp pool <pool-name>.
From the Global Config mode, enter ip dhcpv6 pool <pool-name>.
From the Global Config mode, enter the stack command.
From the Global Config mode, enter the
command.
arp access-list
To exit to the Global Config mode, enter exit. To return to the Privileged EXEC mode, enter Ctrl-Z.
To exit to the Global Config mode, enter exit. To return to the Privileged EXEC mode, enter Ctrl-Z.
To exit to the Global Config mode, enter exit. To return to the Privileged EXEC mode, enter Ctrl-Z.
To exit to the Global Config mode, enter exit. To return to the Privileged EXEC mode, enter Ctrl-Z.
To exit to the Global Config mode, enter exit. To return to the Privileged EXEC mode, enter Ctrl-Z.
To exit to the Global Config mode, enter the exit command. To return to the Privileged EXEC mode, enter Ctrl-Z.
To exit to the Global Config mode, enter the
exit command. To return to the Privileged
EXEC mode, enter
Ctrl-Z.

Command Completion and Abbreviation

Command completion finishes spelling the command when you type enough letters of a command to uniquely identify the command keyword. Once you have entered enough letters, press the SPACEBAR or TAB key to complete the word.
Command abbreviation allows you to execute a command when you have entered there are enough letters to uniquely identify the command. You must enter all of the required keywords and parameters before you enter the command.
Using the Command-Line Interface
17
ProSafe Managed Switch

CLI Error Messages

If you enter a command and the system is unable to execute it, an error message appears.
Table 7 describes the most common CLI error messages.
Table 7. CLI Error Messages
Message Text Description
% Invalid input detected at '^' marker. Indicates that you entered an incorrect or unavailable command.
The carat (^) shows where the invalid text is detected. This message also appears if any of the parameters or values are not recognized.
Command not found / Incomplete command. Use ? to list commands.
Ambiguous command Indicates that you did not enter enough letters to uniquely identify
Indicates that you did not enter the required keywords or values.
the command.

CLI Line-Editing Conventions

Table 8 describes the key combinations you can use to edit commands or increase the speed
of command entry. You can access this list from the CLI by entering help from the User or Privileged EXEC modes.
Table 8. CLI Editing Conventions
Key Sequence Description
DEL or Backspace Delete previous character Ctrl-A Go to beginning of line Ctrl-E Go to end of line Ctrl-F Go forward one character Ctrl-B Go backward one character Ctrl-D Delete current character Ctrl-U, X Delete to beginning of line Ctrl-K Delete to end of line Ctrl-W Delete previous word Ctrl-T Transpose previous character Ctrl-P Go to previous line in history buffer Ctrl-R Rewrites or pastes the line Ctrl-N Go to next line in history buffer
Using the Command-Line Interface
18
ProSafe Managed Switch
Table 8. CLI Editing Conventions (Continued)
Key Sequence Description
Ctrl-Y Prints last deleted character Ctrl-Q Enables serial flow Ctrl-S Disables serial flow Ctrl-Z Return to root command prompt Tab, <SPACE> Command-line completion Exit Go to next lower command prompt ? List available commands, keywords, or parameters

Using CLI Help

Enter a question mark (?) at the command prompt to display the commands available in the current mode.
(switch) >?
enable Enter into user privilege mode. help Display help for various special keys. logout Exit this session. Any unsaved changes are lost. ping Send ICMP echo packets to a specified IP address. quit Exit this session. Any unsaved changes are lost. show Display Switch Options and Settings. telnet Telnet to a remote host.
Enter a question mark (?) after each word you enter to display available command keywords or parameters.
(switch) #network ?
javamode Enable/Disable. mgmt_vlan Configure the Management VLAN ID of the switch. parms Configure Network Parameters of the router. protocol Select DHCP, BootP, or None as the network config protocol.
If the help output shows a parameter in angle brackets, you must replace the parameter with a value.
(switch) #network parms ?
<ipaddr> Enter the IP address.
If there are no additional command keywords or parameters, or if additional parameters are optional, the following message appears in the output:
<cr> Press Enter to execute the command
Using the Command-Line Interface
19
ProSafe Managed Switch
You can also enter a question mark (?) after typing one or more characters of a word to list the available command or parameters that begin with the letters, as shown in the following example:
(switch) #show m?
mac-addr-table mac-address-table monitor

Accessing the CLI

You can access the CLI by using a direct console connection or by using a telnet or SSH connection from a remote management host.
For the initial connection, you must use a direct connection to the console port. You cannot access the system remotely until the system has an IP address, subnet mask, and default gateway. You can set the network configuration information manually, or you can configure the system to accept these settings from a BOOTP or DHCP server on your network. For more information, see
Network Interface Commands on page 638.
Using the Command-Line Interface
20

2. Stacking Commands

This chapter contains the following sections:
Dedicated Port Stacking
Stacking Commands
Non-Stop Forwarding Commands
Stack Firmware Synchronization Commands
The commands in this chapter are in two functional groups:
Show commands display switch settings, statistics, and other information.
Configuration commands configure features and options of the switch. For every
configuration command, there is a show command that displays the configuration setting. The Primary Management Unit is the unit that controls the stack.
Note: When configuring a stack using M5300 Series switches and
GSM7328S V2H1, GSM7352S V2H1, GSM7228PS V1H1, or GSM7228PS V1H1switches, refer to on page 715.
2
sdm prefer (Mixed Stacking)

Dedicated Port Stacking

This section describes the commands you use to configure dedicated port stacking.
stack
This command sets the mode to Stack Global Config.
Format stack Mode Global Config
member
This command configures a switch. The <unit> is the switch identifier of the switch to be added/removed from the stack. The <switchindex> is the index into the database of the
21
ProSafe Managed Switch
supported switch types, indicating the type of the switch being preconfigured. The switch index is a 32-bit integer. This command is executed on the Primary Management Unit.
Format member <unit> <switchindex> Mode Stack Global Config
Note: Switch index can be obtained by executing the show supported
switchtype command in User EXEC mode.
no member
This command removes a switch from the stack. The <unit> is the switch identifier of the switch to be removed from the stack. This command is executed on the Primary Management Unit.
Format no member <unit> Mode Stack Global Config
switch priority
This command configures the ability of a switch to become the Primary Management Unit. The <unit> is the switch identifier. The <value> is the preference parameter that allows the user to specify, priority of one backup switch over another. The range for priority is 1 to
15. The switch with the highest priority value will be chosen to become the Primary Management Unit if the active Primary Management Unit fails. The switch priority defaults to the hardware management preference value 1. Switches that do not have the hardware capability to become the Primary Management Unit are not eligible for management.
Default enabled Format switch <unit> priority <value> Mode Global Config
switch renumber
This command changes the switch identifier for a switch in the stack. The <oldunit> is the current switch identifier on the switch whose identifier is to be changed. The <newunit> is the updated value of the switch identifier. Upon execution, the switch will be configured with the configuration information for the new switch, if any. The old switch configuration information will be retained, however the old switch will be operationally unplugged. This command is executed on the Primary Management Unit.
Stacking Commands
22
ProSafe Managed Switch
Note: If the management unit is renumbered, then the running
configuration is no longer applied (that is, the stack acts as if the configuration had been cleared).
Format switch <oldunit> renumber <newunit> Mode Global Config
movemanagement
This command moves the Primary Management Unit functionality from one switch to another. The <fromunit> is the switch identifier on the current Primary Management Unit. The <tounit> is the switch identifier on the new Primary Management Unit. Upon execution, the entire stack (including all interfaces in the stack) is unconfigured and reconfigured with the configuration on the new Primary Management Unit. After the reload is complete, all stack management capability must be performed on the new Primary Management Unit. To preserve the current configuration across a stack move, execute the copy system:running-config nvram:startup-config (in Privileged EXEC) command before performing the stack move. A stack move causes all routes and layer 2 addresses to be lost. This command is executed on the Primary Management Unit. The system prompts you to confirm the management move.
Note: The movemanagement command does not NSF (non-stop
forwarding). To move the management unit to the backup unit, use initiate failover instead. For more information, see
failover on page 33.
Format movemanagement <fromunit> <tounit> Mode Stack Global Config
standby
Use this command to configure a unit as a Standby Management Unit (STBY).
Format standby <unit number> Mode Stack Global Config
initiate
Stacking Commands
23
ProSafe Managed Switch
Note: The Standby Management Unit cannot be the current Management
Unit. The Standby unit should be a management-capable unit.
slot
This command configures a slot in the system. The <unit/slot> is the slot identifier of the slot. The <cardindex> is the index into the database of the supported card types, indicating the type of the card being preconfigured in the specified slot. The card index is a 32-bit integer. If a card is currently present in the slot that is unconfigured, the configured information will be deleted and the slot will be re-configured with default information for the card.
Format slot <unit/slot> <cardindex> Mode Global Config
Note: Card index can be obtained by executing show supported cardtype
command in User EXEC mode.
no slot
This command removes configured information from an existing slot in the system.
Format no slot <unit/slot> <cardindex> Mode Global Config
Note: Card index can be obtained by executing show supported cardtype
command in User EXEC mode.
set slot disable
This command configures the administrative mode of the slot(s). If you specify [all], the command is applied to all slots, otherwise the command is applied to the slot identified by <unit/slot>.
If a card or other module is present in the slot, this administrative mode will effectively be applied to the contents of the slot. If the slot is empty, this administrative mode will be applied
Stacking Commands
24
ProSafe Managed Switch
to any module that is inserted into the slot. If a card is disabled, all the ports on the device are operationally disabled and shown as “unplugged” on management screens.
Format set slot disable [<unit/slot> | all] Mode Global Config
no set slot disable
This command unconfigures the administrative mode of the slot(s). If you specify [all], the command removes the configuration from all slots, otherwise the configuration is removed from the slot identified by <unit/slot>.
If a card or other module is present in the slot, this administrative mode removes the configuration from the contents of the slot. If the slot is empty, this administrative mode removes the configuration from any module inserted into the slot. If a card is disabled, all the ports on the device are operationally disabled and shown as “unplugged” on management screens.
Format no set slot disable [<unit/slot> | all] Mode Global Config
set slot power
This command configures the power mode of the slot(s) and allows power to be supplied to a card located in the slot. If you specify [all], the command is applied to all slots, otherwise the command is applied to the slot identified by <unit/slot>.
Use this command when installing or removing cards. If a card or other module is present in this slot, the power mode is applied to the contents of the slot. If the slot is empty, the power mode is applied to any card inserted into the slot.
Format set slot power [<unit/slot> | all] Mode Global Config
no set slot power
This command unconfigures the power mode of the slot(s) and prohibits power from being supplied to a card located in the slot. If you specify [all], the command prohibits power to all slots, otherwise the command prohibits power to the slot identified by <unit/slot>.
Use this command when installing or removing cards. If a card or other module is present in this slot, power is prohibited to the contents of the slot. If the slot is empty, power is prohibited to any card inserted into the slot.
Format no set slot power [<unit/slot> | all] Mode Global Config
Stacking Commands
25
ProSafe Managed Switch
reload (Stack)
This command resets the entire stack or the identified <unit>. The <unit> is the switch identifier. The system prompts you to confirm that you want to reset the switch.
Format reload [<unit>] Mode User EXEC
show slot
This command displays information about all the slots in the system or for a specific slot.
Format show slot [<unit/slot>] Mode User EXEC
Term Definition Slot The slot identifier in a <unit/slot> format. Slot Status The slot is empty, full, or has encountered an error Admin State The slot administrative mode is enabled or disabled. Power State The slot power mode is enabled or disabled. Configured Card
Model Identifier Pluggable Cards are pluggable or non-pluggable in the slot. Power Down Indicates whether the slot can be powered down.
The model identifier of the card preconfigured in the slot. Model Identifier is a 32-character field used to identify a card.
If you supply a value for <unit/slot>, the following additional information appears:
Term Definition Inserted Card
Model Identifier Inserted Card
Description Configured Card
Description
The model identifier of the card inserted in the slot. Model Identifier is a 32-character field used to identify a card. This field is displayed only if the slot is full.
The card description. This field is displayed only if the slot is full.
The card description of the card preconfigured in the slot.
Stacking Commands
26
ProSafe Managed Switch
show supported cardtype
This commands displays information about all card types or specific card types supported in the system.
Format show supported cardtype [<cardindex>] Mode User EXEC
If you do not supply a value for <cardindex>, the following output appears:
Term Definition Card Index (CID) The index into the database of the supported card types. This index is used when
preconfiguring a slot.
Card Model Identifier
The model identifier for the supported card type.
If you supply a value for <cardindex>, the following output appears:
Term Definition Card Type The 32-bit numeric card type for the supported card. Model Identifier The model identifier for the supported card type. Card Description The description for the supported card type.
show switch
This command displays information about all units in the stack or a single unit when you specify the unit value. For units that would normally be allowed to join the stack but do not have a matching stack template ID, their switch status is shown as “STM Mismatch.”
Format show switch [<unit>] Mode Privileged EXEC
Term Definition Switch The unit identifier assigned to the switch.
When you do not specify a value for <unit>, the following information appears:
Term Definition Management
Status Preconfigured
Model Identifier
Indicates whether the switch is the Primary Management Unit, a stack member, or the status is unassigned.
The model identifier of a preconfigured switch ready to join the stack. The Model Identifier is a 32-character field assigned by the device manufacturer to identify the device.
Stacking Commands
27
Term Definition
ProSafe Managed Switch
Plugged-In Model Identifier
Switch Status The switch status. Possible values for this state are: OK, Unsup ported, Code
Code Version The detected version of code on this switch.
The model identifier of the switch in the stack. Model Identifier is a 32-character field assigned by the device manufacturer to identify the device.
Mismatch, Config Mismatch, or Not Present.
When you specify a value for <unit>, the following information appears:
Term Definition Management
Status Hardware
Management Preference
Admin Management Preference
Switch Type The 32-bit numeric switch type. Model Identifier The model identifier for this switch. Model Identifier is a 32-character field assigned by
Indicates whether the switch is the Primary Management Unit, a stack member, or the status is unassigned.
The hardware management preference of the switch. The hardware management preference can be disabled or unassigned.
The administrative management preference value assigned to the switch. This preference value indicates how likely the switch is to be chosen as the Primary Management Unit.
the device manufacturer to identify the device.
Switch Status The switch status. Possible values are OK, Unsupported, Code Mismatch, Config
Mismatch, or Not Present.
Switch Description
Expected Code Version
Detected Code Version
Detected Code in Flash
Stack Template ID The ID of the stack template currently in use. For example: 3. Stack Template
Description Up Time The system up time.
The switch description.
The expected code version.
The version of code running on this switch. If the switch is not present and the data is from pre-configuration, then the code version is “None”.
The version of code that is currently stored in FLASH memory on the switch. This code executes after the switch is reset. If the switch is not present and the data is from pre-configuration, then the code version is “None”.
The stack template description. For example: v1 and v2 Mix.
Stacking Commands
28
ProSafe Managed Switch
show supported switchtype
This commands displays information about all supported switch types or a specific switch type.
Format show supported switchtype [<switchindex>] Modes
• User EXEC
• Privileged EXEC
If you do not supply a value for <switchindex>, the following output appears:
Term Definition Switch Index (SID) The index into the database of supported switch types. This index is used when
preconfiguring a member to be added to the stack.
Model Identifier The model identifier for the supported switch type. Management
Preference Code Version The code load target identifier of the switch type.
The management preference value of the switch type.
If you supply a value for <switchindex>, the following output appears:
Term Definition Switch Type The 32-bit numeric switch type for the supported switch. Model Identifier The model identifier for the supported switch type. Switch
Description
The description for the supported switch type.

Stacking Commands

This section describes the commands you use to view and configure stacking information.
stack-port
This command sets stacking per port to either stack or ethernet mode.
Default stack Format stack-port <unit/slot/port> [{ethernet | stack}] Mode Stack Global Config
Stacking Commands
29
ProSafe Managed Switch
show stack-port
This command displays summary stack-port information for all interfaces.
Format show stack-port Mode Privileged EXEC
Term Definition QOS Mode Stacking QOS Mode for all Interfaces.
For Each Interface:
Term Definition Unit The unit number. Interface The slot and port numbers. Configured Stack
Mode Running Stack
Mode Link Status Status of the link. Link Speed Speed (Gbps) of the stack port link.
Stack or Ethernet.
Stack or Ethernet.
show stack-port counters
This command displays summary data counter information for all interfaces.
Format show stack-port counters Mode Privileged EXEC
Term Definition Unit The unit number. Interface The slot and port numbers. Tx Data Rate Trashing data rate in megabits per second on the stacking port. Tx Error Rate Platform-specific number of transmit errors per second. Tx Total Error Platform-specific number of total transmit errors since power-up. Rx Data Rate Receive data rate in megabits per second on the stacking port.