S350 Series 24-Port (PoE+) and 48-Port
Gigabit Ethernet Smart Managed Pro
Switches with 2 or 4 SFP Ports
Models
GS324T
GS324TP
GS348T
NETGEAR, Inc.
350 E. Plumeria DriveFebruary 2019
San Jose, CA 95134, USA202-11911-01
Page 2
S350 Series 24- (PoE+) and 48-Port Gigabit Ethernet Smart Managed Pro Switches
Support
Thank you for purchasing this NETGEAR product. You can visit
https://www.netgear.com/support/ to register your product, get help, access the latest
downloads and user manuals, and join our community. We recommend that you use
only official NETGEAR support resources.
Compliance and Conformity
For regulatory compliance information including the EU Declaration of Conformity, visit
https://www.netgear.com/about/regulatory/.
See the regulatory compliance document before connecting the power supply.
Do not use this device outdoors. If you connect cables or devices that are outdoors to
this device, see http://kb.netgear.com/000057103 for safety and warranty information.
This hardware installation guide is for the following NETGEAR switches:
S350 Series 24-Port Gigabit Ethernet Smart Managed Pro Switch with 2 SFP
•
Ports (GS324T)
This model provides twenty-four Gigabit RJ-45 copper ports and two dedicated SFP
fiber ports.
S350 Series 24-Port Gigabit PoE+ Ethernet Smart Managed Pro Switch with
•
2 SFP Ports (GS324TP)
This model provides twenty-four Gigabit PoE+ RJ-45 copper ports and two dedicated
SFP fiber ports. Power over Ethernet (PoE) lets you provide power to PoE-capable
devices such as WiFi access points, VoIP phones, and IP security cameras so that
you do not need to use power supplies for those devices. The model can supply up
to 30W PoE+ (IEEE 802.3at) to each copper port, with a maximum PoE power budget
of 190W across all active PoE+ copper ports.
S350 Series 48-Port Gigabit Ethernet Smart Managed Pro Switch with 4 SFP
•
Ports (GS348T)
This model provides forty-eight Gigabit RJ-45 copper ports and four dedicated SFP
fiber ports.
This hardware installation guide complements the installation guide that came with your
switch. This chapter serves as an introduction to the switch and includes the following
sections:
• Overview
• Features
• Safety instructions and warnings
Note: For more information about the topics that are covered in this manual, visit the
support website at netgear.com/support/.
Note: For technical specifications, see the data sheet at
netgear.com/business/products/switches/smart/. For switch documentation, visit
netgear.com/support/download/.
5
Page 6
S350 Series 24- (PoE+) and 48-Port Gigabit Ethernet Smart Managed Pro Switches
Overview
The switch provides twenty-four or forty-eight 10/100/1000BASE-T RJ-45 copper ports
that support nonstop 10/100/1000M Layer 2 networks. For model GS324TP, all RJ-45
ports support PoE+. Two or four additional fiber ports can accept small form-factor
pluggable (SFP) gigabit interface converters (GBICs) for 1G fiber connectivity.
Note: For information about application samples, see Applications on page 21.
The switch provides administrative management options that let you configure, monitor,
and control the network. Using the local browser–based management interface, in this
guide referred to as the local browser interface, you can configure the switch and the
network, including the ports, the management VLAN, VLANs for traffic control, link
aggregation for increased bandwidth, Quality of Service (QoS) for prioritizing traffic,
and network security.
For initial discovery of the switch on the network, use one of the following methods, all
of which are described in detail in the user manual:
NETGEAR Insight mobile app
•
NETGEAR Smart Control Center Utility
•
NETGEAR Switch Discovery Tool
•
You can also get the IP address of the switch from the DHCP server in the network or
use an IP scanner utility.
After discovery, you can configure the switch using the local browser interface for
advanced setup and configuration of features, or the Smart Control Center program
for very basic setup. For more information, see the user manual, which you can download
from netgear.com/support/download/.
You can install the switch freestanding or rack mounted in a wiring closet or equipment
room. The switch is IEEE compliant and offers low latency. All ports can automatically
negotiate to the highest speed, which makes the switch very suitable for a mixed
environment with Fast Ethernet and Gigabit Ethernet.
Use Category 5e (Cat 5e) or higher-rated Ethernet cables terminated with RJ-45
connectors to make Gigabit connections.
Hardware Installation Guide6Introduction
Page 7
S350 Series 24- (PoE+) and 48-Port Gigabit Ethernet Smart Managed Pro Switches
Features
The switch supports the following key hardware features:
24 or 48 Gigabit Ethernet ports:
•
-Models GS324T and GS324TP provide 24 Gigabit Ethernet ports
-Model GS348T provides 48 Gigabit Ethernet ports
2 or 4 dedicated SFP fiber ports:
•
-
Models GS324T and GS324TP provide 2 dedicated SFP fiber ports
-
Model GS348T provides 4 dedicated SFP fiber ports
PoE support (model GS324TP):
•
-24 PoE+ (802.3at) ports
-
Total PoE power budget of 190W for the switch
MAC table size of 16K.
•
52 Gbps or 104 Gbps full-duplex, nonblocking switch fabric:
•
-
Models GS324T and GS324TP provide 52 Gbps full-duplex, nonblocking switch
fabric
-
Model GS348T provides 104 Gbps full-duplex, nonblocking switch fabric
Variable speed fan that can lower the noise level during low temperatures (models
•
GS324TP and GS348T):
-For model GS324TP, the acoustic noise is equal to or less than 32.8 dBA at 77°F
(25°C)
-For model GS348T, the acoustic noise is equal to or less than 26.0 dBA at 77°F
(25°C)
Includes the following mounting hardware:
•
-
Four rubber footpads for tabletop installation
-
Rack-mount kit (brackets and screws) for rack installation
Hardware Installation Guide7Introduction
Page 8
S350 Series 24- (PoE+) and 48-Port Gigabit Ethernet Smart Managed Pro Switches
Full compatibility with IEEE standards:
•
-IEEE 802.3 Ethernet
-IEEE 802.3u 100BASE-T
-IEEE 802.3z Gigabit Ethernet 1000BASE-SX/LX
-IEEE 802.3ab 1000BASE-T
-IEEE 802.3i 10BASE-T
-IEEE 802.1Q VLAN tagging
-
IEEE 802.3x Full-duplex flow control
-IEEE 802.3ad Link Aggregation Control Protocol (LACP)
-IEEE 802.1ab LLDP
-
IEEE 802.1p Class of Service (QoS)
-IEEE 802.1D Spanning Tree Protocol (STP)
-IEEE 802.1s Multiple Spanning Tree Protocol (MSTP)
-IEEE 802.1w Rapid Spanning Tree Protocol (RSTP)
-IEEE 802.1x RADIUS network access control
-
IEEE 802.3az Energy Efficient Ethernet (EEE)
AutoSensing and autonegotiating capabilities for all ports.
•
Auto Uplink technology is supported on all ports.
•
Automatic address learning function to build the packet-forwarding information
•
table. The table contains up to 16K Media Access Control (MAC) addresses.
Store-and-forward transmission to remove bad packets from the network.
•
Active flow control to minimize packet loss and frame drops.
•
Half-duplex backpressure control.
•
Per-port status LEDs and system status LEDs.
•
Per-port PoE status LEDs and system PoE Max LED (model GS324TP)
•
NETGEAR green power-saving features:
•
-
Energy efficiency mode that fully conforms to the IEEE802.3az standard
-Per-port automatic change to a lower power mode when the port link is down
Hardware Installation Guide8Introduction
Page 9
S350 Series 24- (PoE+) and 48-Port Gigabit Ethernet Smart Managed Pro Switches
Safety instructions and warnings
Use the following safety guidelines to ensure your own personal safety and to help
protect your system from potential damage.
To reduce the risk of bodily injury, electrical shock, fire, and damage to the equipment,
observe the following precautions:
This product is designed for indoor use only in a temperature-controlled and
•
humidity-controlled environment. For more information, see the environmental
specifications in the appendix or the data sheet.
Any device that is located outdoors and connected to this product must be properly
grounded and surge protected.
Failure to follow these guidelines can result in damage to your NETGEAR product,
which might not be covered by NETGEAR’s warranty, to the extent permissible by
applicable law.
Observe and follow service markings:
•
-Do not service any product except as explained in your system documentation.
Some devices should never be opened.
-
If applicable to your device, opening or removing covers that are marked with
the triangular symbol with a lightning bolt can expose you to electrical shock.
We recommend that only a trained technician services components inside these
compartments.
If any of the following conditions occur, unplug the product from the electrical outlet
•
and replace the part or contact your trained service provider:
-Depending on your device, the power adapter, power adapter cable, power
cable, extension cable, or plug is damaged.
-
An object fell into the product.
-The product was exposed to water.
-The product was dropped or damaged.
-
The product does not operate correctly when you follow the operating
instructions.
Keep your system away from radiators and heat sources. Also, do not block cooling
•
vents.
Do not spill food or liquids on your system components, and never operate the
•
product in a wet environment. If the system gets wet, see the appropriate section in
your troubleshooting guide, or contact your trained service provider.
Hardware Installation Guide9Introduction
Page 10
S350 Series 24- (PoE+) and 48-Port Gigabit Ethernet Smart Managed Pro Switches
Do not push any objects into the openings of your system. Doing so can cause fire
•
or electric shock by shorting out interior components.
Use the product only with approved equipment.
•
If applicable to your device, allow the product to cool before removing covers or
•
touching internal components.
Operate the product only from the type of external power source indicated on the
•
electrical ratings label. If you are not sure of the type of power source required,
consult your service provider or local power company.
To avoid damaging your system, if your device uses a power supply with a voltage
•
selector, be sure that the selector is set to match the power at your location:
-
115V, 60 Hz in most of North and South America and some Far Eastern countries
such as South Korea and Taiwan
-100V, 50 Hz in eastern Japan and 100V, 60 Hz in western Japan
-
230V, 50 Hz in most of Europe, the Middle East, and the Far East
Be sure that attached devices are electrically rated to operate with the power available
•
in your location.
Depending on your device, use only a supplied power adapter or approved power
•
cable:
If your device uses a power adapter:
-
If you were not provided with a power adapter, contact your local NETGEAR
reseller.
-
The power adapter must be rated for the product and for the voltage and current
marked on the product electrical ratings label.
If your device uses a power cable:
-
If you were not provided with a power cable for your system or for any
AC-powered option intended for your system, purchase a power cable approved
for your country.
-
The power cable must be rated for the product and for the voltage and current
marked on the product electrical ratings label. The voltage and current rating of
the cable must be greater than the ratings marked on the product.
To help prevent electric shock, plug the system and peripheral power cables into
•
properly grounded electrical outlets.
If applicable to your device, the peripheral power cables are equipped with
•
three-prong plugs to help ensure proper grounding. Do not use adapter plugs or
remove the grounding prong from a cable. If you must use an extension cable, use
a three-wire cable with properly grounded plugs.
Hardware Installation Guide10Introduction
Page 11
S350 Series 24- (PoE+) and 48-Port Gigabit Ethernet Smart Managed Pro Switches
Observe extension cable and power strip ratings. Make sure that the total ampere
•
rating of all products plugged into the extension cable or power strip does not
exceed 80 percent of the ampere ratings limit for the extension cable or power strip.
To help protect your system from sudden, transient increases and decreases in
•
electrical power, use a surge suppressor, line conditioner, or uninterruptible power
supply (UPS).
Position system cables, power adapter cables, or power cables carefully. Route
•
cables so that they cannot be stepped on or tripped over. Be sure that nothing rests
on any cables.
Do not modify power adapters, power adapter cables, power cables or plugs. Consult
•
a licensed electrician or your power company for site modifications.
Always follow your local and national wiring rules.
•
Hardware Installation Guide11Introduction
Page 12
2
Hardware Overview
This chapter describes the switch hardware features.
The chapter includes the following sections:
• Hardware overview of model GS324T
• Hardware overview of model GS324TP
• Hardware overview of model GS348T
• RJ-45 ports for 10/100/1000M BASE-T Ethernet connectivity
• SFP ports for fiber connectivity
• Reset button
12
Page 13
S350 Series 24- (PoE+) and 48-Port Gigabit Ethernet Smart Managed Pro Switches
Hardware overview of model GS324T
Model GS324T provides twenty four 10/100/1000BASE-T RJ-45 ports and two dedicated
Gigabit SFP fiber ports.
Model GS324T: Front panel with ports and LEDs
The following figure shows the front panel of model GS324T.
Figure 1. Model GS324T front panel
From left to right, the front panel of model GS324T provides the following components:
Power LED (see Model GS324T: LEDs on page 14).
•
Recessed Reset button (see Reset button on page 20).
•
Twenty four port LEDs (1–24), one for each associated RJ-45 port, and two port LEDs
•
(25F and 26F), one for each associated fiber port. For the RJ-45 ports, each LED
functions as the combined link, speed, and activity LED for its associated port. For
the fiber ports, each LED functions as the link and activity LED for its associated port.
(See Model GS324T: LEDs on page 14.)
Twenty four independent 10/100/1000BASE-T RJ-45 ports (1–24, see RJ-45 ports
•
for 10/100/1000M BASE-T Ethernet connectivity on page 19).
Two dedicated Gigabit SFP fiber ports (25F andf 26F) that can accept optional
•
transceiver modules (see SFP ports for fiber connectivity on page 19) .
Hardware Installation Guide13Hardware Overview
Page 14
S350 Series 24- (PoE+) and 48-Port Gigabit Ethernet Smart Managed Pro Switches
Model GS324T: Back panel
The back panel of model GS324T contains a Kensington lock slot for an optional security
cable and a 100–240VAC, 50/60Hz, 1.0A AC power connector for the AC power cable
that came in the switch package.
The following figure shows the back panel of model GS324T.
Figure 2. Model GS324T back panel
Model GS324T: LEDs
This section describes the LED designations of model GS324T. All LEDs are to the left
of the ports.
Table 1. Model GS324T LEDs on the front panel
DescriptionLED
Power LED
RJ-45 port LED
Link, speed, and activity for
Ethernet ports 1 to 24
Fiber port LED
Link and activity for SFP fiber
ports 25F and 26F
Solid green. The switch is powered on and operating normally.
Solid yellow. The switch is booting.
Off. Power is not supplied to the switch.
Off. No link is established.
Solid green. A valid 1 Gbps link is established.
Blinking green. The port is transmitting or receiving packets at 1 Gbps.
Solid yellow. A valid 10 Mbps or 100 Mbps link is established.
Blinking yellow. The port is transmitting or receiving packets at 10 Mbps or 100
Mbps.
Off. No SFP module link is established.
Solid green. A valid 1 Gbps link is established.
Blinking green. The SFP fiber port is transmitting or receiving packets at 1 Gbps.
Hardware Installation Guide14Hardware Overview
Page 15
S350 Series 24- (PoE+) and 48-Port Gigabit Ethernet Smart Managed Pro Switches
Hardware overview of model GS324TP
Model GS324TP provides twenty four 10/100/1000BASE-T RJ-45 PoE+ ports and two
dedicated Gigabit SFP fiber ports.
Model GS324TP: Front panel with ports and LEDs
The following figure shows the front panel of model GS324TP.
Figure 3. Model GS324TP front panel
From left to right, the front panel of model GS324TP provides the following components:
Power LED (see Model GS324TP: LEDs on page 16).
•
Fan LED (see Model GS324TP: LEDs on page 16).
•
PoE Max LED (see Model GS324TP: LEDs on page 16).
•
Recessed Reset button (see Reset button on page 20).
•
Port LEDs:
•
-
Twenty four upper port LEDs (1–24), each LED functioning as the combined link,
speed, and activity LED for its associated RJ-45 port.
-
Twenty four lower port LEDs (1–24), each LED functioning as the PoE status LED
for its associated RJ-45 port.
-
Two port LEDs (25F and 26F), each LED functioning as the link and activity LED
for its associated fiber port.
For more information about the port LEDs, see Model GS324TP: LEDs on page 16.
Twenty four independent 10/100/1000BASE-T PoE+ RJ-45 ports (1–24, see RJ-45
•
ports for 10/100/1000M BASE-T Ethernet connectivity on page 19).
Two dedicated Gigabit SFP fiber ports (25F and 26F) that can accept optional
•
transceiver modules (see SFP ports for fiber connectivity on page 19) .
Hardware Installation Guide15Hardware Overview
Page 16
S350 Series 24- (PoE+) and 48-Port Gigabit Ethernet Smart Managed Pro Switches
Model GS324TP: Back panel
The back panel of model GS324TP contains a Kensington lock slot for an optional
security cable and a 100–240VAC, 50/60Hz, 5A AC power connector for the AC power
cable that came in the switch package.
The following figure shows the back panel of model GS324TP.
Figure 4. Model GS324TP back panel
Model GS324TP: LEDs
This section describes the LED designations of model GS324TP. All LEDs are to the left
of the ports.
Table 2. Model GS324TP LEDs on the front panel
DescriptionLED
Power LED
Fan LED
PoE Max LED
RJ-45 upper LED
Link, speed, and activity for
Ethernet ports 1 to 24
Solid green. The switch is powered on and operating normally.
Solid yellow. The switch is booting.
Off. Power is not supplied to the switch.
Off. The fan is operating normally.
Solid yellow. A problem occurred with the fan.
Off. Sufficient (more than 7W of) PoE power is available.
Solid yellow. Less than 7W of PoE power is available.
Blinking yellow. At least once during the previous two minutes, less than 7W of PoE
power was available.
Off. No link is established.
Solid green. A valid 1 Gbps link is established.
Blinking green. The port is transmitting or receiving packets at 1 Gbps.
Solid yellow. A valid 10 Mbps or 100 Mbps link is established.
Blinking yellow. The port is transmitting or receiving packets at 10 Mbps or 100
Mbps.
Hardware Installation Guide16Hardware Overview
Page 17
S350 Series 24- (PoE+) and 48-Port Gigabit Ethernet Smart Managed Pro Switches
Table 2. Model GS324TP LEDs on the front panel (Continued)
DescriptionLED
RJ-45 lower LED
PoE status for Ethernet ports
1 to 24.
Fiber port LED
Link and activity for SFP fiber
ports 25F and 26F
Off. The port is not delivering PoE power.
Solid green. The port is delivering PoE power.
Solid yellow. A PoE fault occurred.
Off. No SFP module link is established.
Solid green. A valid 1 Gbps link is established.
Blinking green. The SFP fiber port is transmitting or receiving packets at 1 Gbps.
Hardware overview of model GS348T
Model GS348T provides forty eight 10/100/1000BASE-T RJ-45 ports and four dedicated
Gigabit SFP fiber ports.
Model GS348T: Front panel with ports and LEDs
The following figure shows the front panel of model GS348T.
Figure 5. Model GS348T front panel
From left to right, the front panel of model GS348T provides the following components:
Power LED (see Model GS348T: LEDs on page 18).
•
Fan LED (see Model GS348T: LEDs on page 18).
•
Recessed Reset button (see Reset button on page 20).
•
Forty eight 10/100/1000BASE-T RJ-45 ports (1–48, see RJ-45 ports for 10/100/1000M
•
BASE-T Ethernet connectivity on page 19), each with a LED that functions as the
combined link, speed, and activity LED (see Model GS348T: LEDs on page 18). All
RJ-45 port LEDs are above the ports.
Four dedicated Gigabit SFP fiber ports (49F–52F) that can accept optional transceiver
•
modules (see SFP ports for fiber connectivity on page 19), each with a single LED
that functions as the combined link and activity LED (see Model GS348T: LEDs on
page 18). All fiber port LEDs are above the ports.
Hardware Installation Guide17Hardware Overview
Page 18
S350 Series 24- (PoE+) and 48-Port Gigabit Ethernet Smart Managed Pro Switches
Model GS348T: Back panel
The back panel of model GS348T contains a Kensington lock slot for an optional security
cable and a 100–240VAC, 50/60Hz, 1.5A AC power connector for the AC power cable
that came in the switch package.
The following figure shows the back panel of model GS348T.
Figure 6. Model GS348T back panel
Model GS348T: LEDs
This section describes the LED designations of model GS348T. All port LEDs are above
the ports.
Table 3. Model GS348T LEDs on the front panel
DescriptionLED
Power LED
Fan LED
RJ-45 LED
Link, speed, and activity for
Ethernet ports 1 to 48
Fiber port LED
Link and activity for SFP fiber
ports 49F, 50F, 51F, and 52F
Solid green. The switch is powered on and operating normally.
Solid yellow. The switch is booting.
Off. Power is not supplied to the switch.
Off. The fan is operating normally.
Solid yellow. A problem occurred with the fan.
Off. No link is established.
Solid green. A valid 1 Gbps link is established.
Blinking green. The port is transmitting or receiving packets at 1 Gbps.
Solid yellow. A valid 10 Mbps or 100 Mbps link is established.
Blinking yellow. The port is transmitting or receiving packets at 10 Mbps or 100
Mbps.
Off. No SFP module link is established.
Solid green. A valid 1 Gbps link is established.
Blinking green. The SFP fiber port is transmitting or receiving packets at 1 Gbps.
Hardware Installation Guide18Hardware Overview
Page 19
S350 Series 24- (PoE+) and 48-Port Gigabit Ethernet Smart Managed Pro Switches
RJ-45 ports for 10/100/1000M BASE-T
Ethernet connectivity
All RJ-45 copper ports support autosensing. When you insert a cable into an RJ-45 port,
the switch automatically ascertains the maximum speed (10 Mbps, 100 Mbps, or 1 Gbps)
and duplex mode (half-duplex or full-duplex) of the attached device. All ports support
a Cat 5e cable (or higher-rated Ethernet cable) terminated with an 8-pin RJ-45 connector.
To simplify the procedure for attaching devices, all RJ-45 ports support Auto Uplink
technology. This technology allows attaching devices to the RJ-45 ports with either
straight-through or crossover cables.
When you insert a cable into the switch’s RJ-45 port, the switch automatically performs
the following actions:
Senses whether the cable is a straight-through or crossover cable.
•
Determines whether the link to the attached device requires a normal connection
•
(such as when you are connecting the port to a computer) or an uplink connection
(such as when you are connecting the port to a router, switch, or hub).
Automatically configures the RJ-45 port to enable communications with the attached
•
device. The Auto Uplink technology compensates for setting uplink connections
while eliminating concern about whether to use crossover or straight-through cables
when you attach devices.
All RJ-45 copper ports on model GS324TP support PoE+.
SFP ports for fiber connectivity
To enable fiber connections, SFP fiber ports accommodate standard small form-factor
pluggable (SFP) gigabit interface converters (GBICs, also referred to as transceiver
modules). GBICs are sold separately from the switch.
The switch supports the NETGEAR SFP transceiver modules that are listed in the following
table.
Hardware Installation Guide19Hardware Overview
Page 20
S350 Series 24- (PoE+) and 48-Port Gigabit Ethernet Smart Managed Pro Switches
For more information about NETGEAR SFP transceiver modules, visit
netgear.com/business/products/switches/modules-accessories.
Note: If you use a third-party passive direct-attach cable (DAC), the length of the cable
must not exceed 5 meters (16.4 feet).
Reset button
The switch provides a recessed Reset button on the front panel so that you can either
restart (power-cycle) the switch or return the switch to its factory default settings, causing
all custom settings to be erased.
To restart the switch or return the switch to its factory default settings:
1. Insert a device such as a straightened paper clip into the opening.
2.
Do one of the following:
Restart the switch. Press the Reset button for about two seconds. (Do not press
•
the button for more than five seconds!)
The switch restarts but retains its custom settings. During this process, the Power
LED lights amber.
Return the switch to its factory default settings. Press the Reset button for at
•
least five seconds.
The switch restarts and returns to its factory default settings. During this process,
the Power LED lights amber.
Hardware Installation Guide20Hardware Overview
Page 21
3
Applications
The switch is designed to provide flexibility in configuring network connections. The
switch can be used as your only network traffic–distribution device for PoE and non-PoE
devices or with 10 Mbps, 100 Mbps, and 1 Gbps Ethernet and fiber hubs, routers, access
points, and other switches.
This chapter includes the following sections:
• Network switching
• PoE overview (model GS324TP)
• PoE and network switching (model GS324TP)
21
Page 22
S350 Series 24- (PoE+) and 48-Port Gigabit Ethernet Smart Managed Pro Switches
Network switching
You can use the switch as a network switch to build a network that provides up to 1 Gbps
access to desktop computers, access points, non-PoE surveillance cameras, a NAS,
servers such as a file server, an IPTV, and so on. Connect the switch to a network router
that is connected to the Internet.
With 1 Gbps connections, the switch always functions in full-duplex mode. Any switch
port that is connected to a computer or file server can provide up to 2 Gbps bidirectional
throughput.
You must connect one LAN port on the switch to a LAN port on a network router (see
device 2 in the following figure) that is connected to the Internet (see 3). You can also
make a 1 Gbps fiber connection to a network router that supports fiber and that is
connected to the Internet.
If you connect a WiFi access point (see device 4 in the following figure) to the switch,
you can connect a tablet (see device 5) or smartphone (see device 6) to the WiFi network
and use NETGEAR Insight to discover the switch.
Figure 7. Sample network switching with model GS348T
DeviceNumberDeviceNumber
Desktop7Switch model GS348T1
IP camera8Network router2
Laptop9Internet3
ReadyNAS storage system10WiFi access point4
Hardware Installation Guide22Applications
Page 23
S350 Series 24- (PoE+) and 48-Port Gigabit Ethernet Smart Managed Pro Switches
(Continued)
DeviceNumberDeviceNumber
5
Insight to discover the switch.
6
Insight to discover the switch.
Desktop11Tablet, which allows you to use NETGEAR
Smart TV12Smartphone, which allows you use NETGEAR
PoE overview (model GS324TP)
Model GS324TP supports twenty four Power over Ethernet plus (PoE+) ports. The switch
can supply up to 30W PoE+ (IEEE 802.3at) to each port up to its total maximum PoE
power budget of 190W across all active PoE+ ports. The switch is also compatible with
PoE (IEEE 802.3af).
Supplied power is prioritized according to the port order, up to the total power budget
of the device. Port 1 receives the highest PoE priority, while port 24 is relegated to the
lowest PoE priority.
If the power requirements for attached devices exceed the total power budget of the
switch, the PoE power to the device on the highest-numbered active PoE+ port is
disabled to make sure that the devices connected to the higher-priority, lower-numbered
PoE+ ports are supported first.
Although a device is listed as an 802.3at PoE+-or 802.3af PoE–powered device, it might
not require the maximum power limit that is specified by its IEEE standard. Many devices
require less power, allowing more than six PoE+ devices or more than twelve PoE devices
to active be simultaneously.
For more information about PoE, see the installation guide and user manual, both of
which you can download from netgear.com/support/download/.
PoE and network switching (model GS324TP)
Model GS324TP supports both PoE and non-PoE equipment. The following figure shows
an example of how you can connect a PoE WiFi access point (see device 4), a PoE IP
camera (see device 7), a PoE IP video phone (see device 8), and a PoE IP phone (see
device 9) to the switch. In the following figure, non-PoE equipment is also attached to
the switch (see devices 10 and 11).
You must connect one LAN port on the switch to a LAN port on a network router (see
device 2 in the following figure) that is connected to the Internet (see 3). You can also
Hardware Installation Guide23Applications
Page 24
S350 Series 24- (PoE+) and 48-Port Gigabit Ethernet Smart Managed Pro Switches
make a 1 Gbps fiber connection from port 25F or port 26F to a network router that
supports fiber and that is connected to the Internet.
If you connect a WiFi access point (see device 4 in the following figure) to the switch,
you can connect a tablet (see device 5) or smartphone (see device 6) to the WiFi network
and use NETGEAR Insight to discover the switch.
Figure 8. Sample PoE and network switching with model GS324TP
5
Insight to discover the switch.
6
Insight to discover the switch.
DeviceNumberDeviceNumber
PoE IP camera7Switch model GS324TP1
PoE IP video phone8Network router2
PoE IP phone9Internet3
ReadyNAS storage system10PoE WiFi access point4
Desktop11Tablet, which allows you to use NETGEAR
Desktop11Smartphone, which allows you use NETGEAR
Hardware Installation Guide24Applications
Page 25
4
Installation
This chapter describes the installation procedures for the switch. Switch installation
involves the steps described in the following sections:
S350 Series 24- (PoE+) and 48-Port Gigabit Ethernet Smart Managed Pro Switches
Step 1: Prepare the site
Before you install the switch, make sure that the operating environment meets the site
requirements that are listed in the following table.
Table 5. Site requirements
RequirementsCharacteristics
Mounting
Access
Power source
Cabling
Environmental
Desktop installations. Provide a flat table or shelf surface.
Rack-mount installations. Use a 19-inch (48.3-centimeter) EIA standard equipment rack
that is grounded and physically secure. You also need the rack-mount kit that is supplied
with the switch.
Locate the switch in a position that allows you to access the front panel ports, view the
front panel LEDs, and access the power connector on the back panel.
Use the AC power cord that is supplied with the switch. Make sure that the AC outlet is
not controlled by a wall switch, which can accidentally turn off power to the outlet and
the switch.
Route cables to avoid sources of electrical noise such as radio transmitters, broadcast
amplifiers, power lines, and fluorescent lighting fixtures.
Temperature. Install the switch in a dry area with an ambient temperature between 32ºF
and 113ºF (0ºC and 45ºC). Keep the switch away from heat sources such as direct sunlight,
warm-air exhausts, hot-air vents, and heaters.
Operating humidity. The maximum relative humidity of the installation location must
not exceed 90 percent, noncondensing.
Ventilation. Do not restrict airflow by covering or obstructing air inlets on the sides of
the switch. Keep at least 2 inches (5.08 centimeters) free on all sides for cooling. The
room or wiring closet in which you install the switch must provide adequate airflow.
Operating conditions. Keep the switch at least 6 feet (1.83 meters) away from the nearest
source of electromagnetic noise, such as a photocopy machine.
Hardware Installation Guide26Installation
Page 27
S350 Series 24- (PoE+) and 48-Port Gigabit Ethernet Smart Managed Pro Switches
Step 2: Protect against electrostatic
discharge
WARNING: Static electricity can harm delicate components inside your switch. To
prevent static damage, discharge static electricity from your body before you touch any
of the electronic components. You can do so by periodically touching an unpainted
metal surface on the switch.
You can also take the following steps to prevent damage from electrostatic discharge
(ESD):
When unpacking a static-sensitive component from its shipping carton, leave it in
•
the antistatic package until you are ready to install it. Just before unwrapping the
antistatic package, discharge static electricity from your body.
Before moving a sensitive component, place it in an antistatic container or package.
•
Handle all sensitive components in a static-safe area. If possible, use antistatic floor
•
pads, workbench pads, and an antistatic grounding strap.
Step 3: Unpack the switch
Check the contents of the boxes to make sure that all items are present before installing
the switch.
To check the package contents:
1.
Place the container on a clean flat surface, and cut all straps securing the container.
2.
Unpack the hardware from the boxes by carefully removing the hardware and placing
it on a secure and clean surface.
3. Remove all packing material.
4.
Verify that the package contains the following items:
a.
Switch of the model that you ordered.
b. AC power cable (varies by region).
Hardware Installation Guide27Installation
Page 28
S350 Series 24- (PoE+) and 48-Port Gigabit Ethernet Smart Managed Pro Switches
c.
A plastic bag (also called mounting kit) that contains the following items so you
can install the switch to best suit your environment:
Rack-mount installation components:
•
-Two brackets.
-
Eight small screws to attach the brackets to the switch (four small screws
for each side).
-
Four large screws and four washers to attach the brackets to the rack (two
screws and two washers for each side).
For model GS324T and model GS324TP, the bag contains an extra set of
four screws to attach the brackets to the rack, allowing you to select the
most suitable set of screws for the rack.
Rubber feet for desktop or table installation.
•
d. Installation guide.
5.
If any item is missing or damaged, contact your local NETGEAR reseller for
replacement.
Step 4: Install the switch
You can install the switch in a standard 19-inch (48.26-centimeter) network equipment
rack or on a flat surface.
Install the switch in a rack
To install the switch in a rack, you need the 19-inch rack-mount kit supplied with the
switch.
To install the switch in a rack:
1.
Attach the supplied mounting brackets to the side of the switch.
2. Insert the screws provided in the product package through each bracket and into
the bracket mounting holes in the switch.
3. Tighten the screws with a No. 2 Phillips screwdriver to secure each bracket.
4. Align the mounting holes in the brackets with the holes in the rack, and insert two
pan-head screws with nylon washers through each bracket and into the rack.
Hardware Installation Guide28Installation
Page 29
S350 Series 24- (PoE+) and 48-Port Gigabit Ethernet Smart Managed Pro Switches
5. Tighten the screws with a No. 2 Phillips screwdriver to secure mounting brackets to
the rack.
Install the switch on a flat surface
The switch comes with four self-adhesive rubber footpads.
To install the switch on a flat surface:
Stick one rubber footpad on each of the four concave spaces on the bottom of the
switch.
The rubber footpads cushion the switch against shock and vibrations. They also
provide ventilation space between stacked switches.
Hardware Installation Guide29Installation
Page 30
S350 Series 24- (PoE+) and 48-Port Gigabit Ethernet Smart Managed Pro Switches
Optional Step 5: Install SFP transceiver
modules
The following optional procedure describes how to install an optional SFP transceiver
module into one of the SFP ports. For information about SFP transceiver modules, see
SFP ports for fiber connectivity on page 19.
Note: Contact your NETGEAR sales office to purchase these modules. If you do not
want to install an SFP module, skip this procedure.
To install an SFP transceiver module:
1. Insert the transceiver into the SFP port.
On models GS324T and GSA324TP, the SFP ports are numbered 25F and 26F. On
model GS348T, the SFP ports are numbered 49F, 50F, 51F, and 52F.
You can install an SFP transceiver module in each SFP port.
2.
Press firmly on the flange of the module to seat it securely into the connector.
Step 6: Connect devices to the switch
The following procedure describes how to connect devices to the switch’s RJ-45 ports.
The switch supports Auto Uplink technology, which allows you to attach devices using
either straight-through or crossover cables. Use a Category 5 (Cat 5), Cat 5e, or Cat 6
cable that is terminated with an RJ-45 connector.
Note: Ethernet specifications limit the cable length between the switch and the attached
device to 328 feet (100 meters). On model GS324TP, if you use a PoE connection and
the powered device (PD) receives insufficient PoE power from the switch, consider using
a shorter cable.
To connect devices to the switch’s RJ-45 ports:
1. Connect a device to an RJ-45 network port on the switch.
Models GS324T and GS348T support non-PoE devices. Model GS324TP supports
both PoE and non-PoE devices.
2.
Verify that all cables are installed correctly.
Hardware Installation Guide30Installation
Page 31
S350 Series 24- (PoE+) and 48-Port Gigabit Ethernet Smart Managed Pro Switches
Step 7: Check the installation
Before you apply power to the switch, perform the following steps.
To check the installation:
1. Inspect the equipment thoroughly.
2.
Verify that all cables are installed correctly.
3.
Check cable routing to make sure that cables are not damaged or creating a safety
hazard.
4. Make sure that all equipment is mounted properly and securely.
Step 8: Apply power and check the LEDs
The switch does not provide an on/off power switch. The AC power cable connection
controls the power.
Before connecting the AC power cable to the AC power receptacle on the switch, select
an AC outlet for the AC power cable. Make sure that the AC outlet is not controlled by
a wall switch, which can turn off power to the switch.
To apply power:
1.
Connect the plug of the AC power cable to the AC power receptacle on the back
of the switch.
2. Plug the AC power cable into a power source such as a wall socket or power strip.
3. Check to see that the LEDs on the switch light correctly.
When you apply power, the Power LED on the switch front panel lights and the port
LEDs for attached devices light.
Note: After you apply power, the Power LED lights solid yellow while the switch
starts. After about two minutes, the switch completes its startup process and the
Power LED turns from yellow to solid green.
If the Power LED does not light, check to see that the AC power cable is plugged in
correctly and that the power source is good.
Hardware Installation Guide31Installation
Page 32
S350 Series 24- (PoE+) and 48-Port Gigabit Ethernet Smart Managed Pro Switches
Step 9: Manage the switch
The switch contains built-in web browser–accessible software for viewing, changing,
and monitoring the way it functions. This management software is not required for the
switch to work. You can use the ports without using the management software. However,
the management software enables the setup of VLAN and trunking features and also
improves the efficiency of the switch, which results in the improvement of its overall
performance as well as the performance of the network.
After you power on the switch for the first time, you can configure the switch using the
local browser interface for advanced setup and configuration of features, or the Smart
Control Center program (which requires a Windows-based computer) for very basic
setup. For more information about managing the switch, including information about
tools to discover the switch IP address in your network, see the user manual, which you
can download from netgear.com/support/download/.
Note: The switch’s default IP address is 192.168.0.239 and its default subnet mask is
255.255.255.0. By default, the DHCP client of the switch is enabled.
Hardware Installation Guide32Installation
Page 33
5
Troubleshooting
This chapter provides information about troubleshooting the switch.
The chapter includes the following sections:
• Troubleshooting chart
• PoE troubleshooting suggestions (model GS324TP)
• Additional troubleshooting suggestions
33
Page 34
S350 Series 24- (PoE+) and 48-Port Gigabit Ethernet Smart Managed Pro Switches
Troubleshooting chart
The following table lists symptoms, possible causes, and possible solutions for problems
that might occur.
Table 6. Troubleshooting chart
Possible SolutionPossible CauseSymptom
and activity LED for a port is
off although the port is
connected to a powered-on
device.
A file transfer is slow or
performance is degraded.
Power is not supplied to the switch.The Power LED is off.
The port connection is not working.The combined link, speed,
One possible cause is that a
broadcast storm occurred and that
a network loop (redundant path)
was created.
Check the power cable connections at the
•
switch and the power source.
Make sure that all cables are used correctly
•
and comply with the Ethernet
specifications.
Check the crimp on the connectors and
•
make sure that the plug is properly
inserted and locked into the port at both
the switch and the connecting device.
Make sure that all cables are used correctly
•
and comply with the Ethernet
specifications.
Check for a defective port, cable, or
•
module by testing them in an alternate
environment where all products are
functioning.
Break the loop by making sure that only one
path exists from any networked device to any
other networked device. After you connect
to the switch local browser interface, you can
configure the Spanning Tree Protocol (STP)
to prevent network loops.
A segment or device is not
recognized as part of the
network.
The combined link, speed,
and activity LEDs for all
connected ports are blinking
continuously and the network
is disabled.
One or more devices are not
properly connected, or cabling
does not meet Ethernet guidelines.
A network loop (redundant path)
was created.
Verify that the cabling is correct.
•
Make sure that all connectors are securely
•
positioned in the required ports. It is
possible that equipment was accidentally
disconnected.
Break the loop by making sure that only one
path exists from any networked device to any
other networked device. After you connect
to the switch local browser interface, you can
configure the Spanning Tree Protocol (STP)
to prevent network loops.
Hardware Installation Guide34Troubleshooting
Page 35
S350 Series 24- (PoE+) and 48-Port Gigabit Ethernet Smart Managed Pro Switches
PoE troubleshooting suggestions (model
GS324TP)
Here are some tips for correcting PoE problems that might occur on model GS324TP:
Make sure that the PoE Max LED is off. If the PoE Max LED is solid yellow, disconnect
•
one or more PoE devices to prevent PoE oversubscription. Start by disconnecting
the device from the highest-numbered port.
Make sure that the Ethernet cables are plugged in correctly. For each powered
•
device (PD) that is connected to the switch, the right port LED on the switch lights
solid green. If the right port LED lights solid yellow, a PoE fault occurred and PoE
halted because of one of the conditions that are listed in the following table.
Table 7. PoE fault conditions and possible solutions
Possible SolutionPoE Fault Condition
A PoE-related short circuit occurred on the port.
The PoE power demand of the PD exceeded the maximum level that the
switch permits. The maximum level is 15.4W for a PoE connection or
30W for a PoE+ connection.
The PoE current on the port exceeded the classification limit of the PD.
The PoE voltage of the port is outside the range that the switch permits.
The problem is most likely with the
attached PD. Check the condition
of the PD or restart the PD by
disconnecting and reconnecting
the PD.
Restart the switch to see if the
condition resolves itself.
Additional troubleshooting suggestions
If the suggestions in the troubleshooting chart do not resolve the problem, see the
following troubleshooting suggestions:
Network adapter cards. Make sure that the network adapters that are installed in
•
the computers are in working condition and the software driver was installed.
Configuration. If problems occur after you alter the network configuration, restore
•
the original connections and determine the problem by implementing the new
changes, one step at a time. Make sure that cable distances, repeater limits, and
other physical aspects of the installation do not exceed the Ethernet limitations.
Hardware Installation Guide35Troubleshooting
Page 36
S350 Series 24- (PoE+) and 48-Port Gigabit Ethernet Smart Managed Pro Switches
Switch integrity. If necessary, verify the integrity of the switch by resetting it. To
•
reset the switch, disconnect the AC power cord from the switch and then reconnect
the AC power cord. If the problem continues, contact NETGEAR technical support.
For more information, visit the support website at netgear.com/support/.
Autonegotiation. The RJ-45 ports negotiate the correct duplex mode, speed, and
•
flow control if the device at the other end of the link supports autonegotiation. If the
device does not support autonegotiation, the switch determines only the speed
correctly, and the duplex mode defaults to half-duplex.
The Gigabit Ethernet ports negotiate speed, duplex mode, and flow control if the
attached device supports autonegotiation.
Hardware Installation Guide36Troubleshooting
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.