NETGEAR INTL LTD
Building 3, University Technology Centre
Curraheen Road, Cork, Ireland
NETGEAR, Inc.
350 East Plumeria Drive
San Jose, CA 95134, USA
© NETGEAR, Inc., NETGEAR and the NETGEAR Logo
are trademarks of NETGEAR, Inc. Any non‑NETGEAR
trademarks are used for reference purposes only.
January 2018
3. Insert the replacement PSU into the power module bay, and gently push
the PSU into the bay until the latch locks.
CAUTION: When inserting the PSU, do not use unnecessary force.
Doing so can damage the connectors on the back of the PSU and on the
midplane.
4. Connect the end of the power cord to the power receptacle on the PSU.
5. Plug the AC power cord into a power source such as a wall socket or
power strip.
When you apply power, both the AC OK LED on the PSU and the
switch’s Power LED that is associated with the power supply bay light.
If these LEDs do not light, make sure that the power cord is plugged in
correctly and that the power source is good.
Power Supply Unit Technical Specifications
Specification PSU
AC input • APS150W. 100–127VAC, 3A, 50–60 Hz or 200–240VAC, 1.5A,
50–60 Hz
• APS250W. 100–240VAC, 3.5–2A, 50–60 Hz
• APS550W. 100–240VAC, 9–4A, 50–60 Hz
• APS1000W. 100–127VAC, 9.9A, 50–60 Hz or 200–240VAC, 7.8A,
50–60 Hz
• APS600W. 90–132VAC, 8A, 47–63 Hz or 180–264VAC, 4A,
47–63 Hz
• APS1200W. 90–132VAC, 15A, 43–67 Hz or 180–264VAC, 8A,
43–67 Hz
DC output • APS150W. +12V 12.5A
• APS250W. +12V 20A or +12 VSB 1A
• APS550W. +54V 10.95A or +12 VSB 2.08A
• APS1000W. 56V 12.12A or +12 VSB 1.8A (@ 100–127VAC)
56V 17.35A or +12 VSB 2.4A (@ 200–240VAC)
• APS600W. +54.5 VDC, 11A
• APS1200W. +54.5 VDC, 22A @ 230 VAC, or 18.35A @ 115 VAC
Specification PSU
Dimensions
(H x W x D)
• APS150W. 1.5 x 2.0 x 7.3 in. (39 x 50.5 x 185 mm)
• APS250W. 1.5 x 2.9 x 7.3 in. (39 x 74 x 185 mm)
• APS550W. 1.64 x 3.6 x 8.65 in. (39.3 x 86.36 x 207.56 mm)
• APS1000W. 1.64 x 3.6 x 8.65 in. (39.3 x 86.36 x 207.56 mm)
• APS600W and APS1200W 2.87 x 7.28 x 1.57 in.
(73 x 185 x 39.8 mm)
Operating
temperature
• APS150W. 23 to 122ºF (–5 to 50ºC)
• APS250W. 32 to 122ºF (0 to 50ºC)
• APS550W and APS1000W. 23 to 122ºF (–5 to 50ºC)
• APS600W and APS1200W. 23 to 122ºF (–5 to 50ºC)
Operating relative
humidity
• APS150W. Up to 95% noncondensing
• APS250W, APS550W, and APS1000W. 5% to 95% noncondensing
• APS600W and APS1200W. 5% to 95% noncondensing
Operating altitude
level
• APS150W. Below 16,000 feet (5,000 m) above sea level
• APS250W, APS550W, and APS1000W. Below 9,800 feet
(3,000 m) above sea level
• APS600W and APS1200. Below 16,000 feet (5,000 m) above sea
level
Storage
temperature
• APS150W and APS250W. –40 to 158ºF (–40 to 70ºC)
• APS550W and APS1000W. –40 to 185ºF (–40 to 85ºC )
• APS600W and APS1200W. –40 to 185ºF (–40 to 85ºC )
Storage altitude
level
Below 49,000 feet (15,000 m) above sea level
MTBF 4,534,733 hrs (~517 years) @ 77ºF (25ºC)
Support
Thank you for purchasing this NETGEAR product. You can visit
www.netgear.com/support to register your product, get help, access the latest
downloads and user manuals, and join our community. We recommend that you
use only ocial NETGEAR support resources.
Si ce produit est vendu au Canada, vous pouvez accéder à ce document en
français canadien à http://downloadcenter.netgear.com/other/.
(If this product is sold in Canada, you can access this document in Canadian
French at http://downloadcenter.netgear.com/other/.)
For the current EU Declaration of Conformity, visit
http://support.netgear.com/app/answers/detail/a_id/11621/.
For regulatory compliance information, visit
http://www.netgear.com/about/regulatory/.
See the regulatory compliance document before connecting the power supply.
Compliance
Safety
IEC 60950-1, EN 60950-1, CB Certificate/Report, UL/CSA 60950-1
CE Low Voltage Directive 2006/95/EC (Europe)
CCC (China)
KC (Korea)
EMC
FCC / ICES-003 Emission (USA/Canada)
CRISP 22 Emission (International)
EN55022 Emission (Europe)
EN55024 Immunity (Europe)
EN61000-4-2 Electrostatic Discharge
EN61000-4-3 Radiated RFI Immunity
EN61000-4-4 Electrical Fast Transients level 4
EN61000-4-5 Electrical Surge Level
EN61000-4-6 RF Conducted
EN61000-4-8 Power Frequency Magnetic Fields
EN61000-4-11 Voltage Dips and Interruptions
EN61000-4-8 Power Frequency Magnetic Fields
EN61000-4-11 Voltage Dips and Interruptions
EN61000-3-2 Harmonics (Europe)
EN61000-3-3 Voltage Flicker (Europe)