This service manual covers the
modification.
Refer the following service manuals
for further information.
INDOOR UNIT
[Service Ref.] [Service manual No.]
PLH-1.6KKHC No.OC123
PLH-3GKHB No.OC096
PLH-5GKHSB
PKH-1.6FKHA
3 No.OC130
PKH-3FKHA
2
PCH-3GKHA No.OC135
PCH-5GKHSA
TECHNICAL & SERVICE MANUAL
SPLIT-TYPE,HEAT PUMP AIR CONDITIONERS
CONTENTS
1. CHANGE POINT···································2
2. SAFETY PRECAUTION ·······················3
3. COMBIINATION OF INDDOR AND
OUTDOOR UNITS ································5
4. SPECIFICATIONS·································6
5. WIRING DIAGRAM·····························14
6.
REFRIGERANT SYSTEM DIAGRAM
······17
7. PARTS LIST········································20
1997
Indoor unit
[Model names] [Service Ref.]
Outdoor unit
Ceiling CassettesSeries PLH
R407C
No.OC159
The Slim Line.
From Mitsubishi Electric.
PLH-1.6KKHCFT PLH-1.6KKHCFT
PLH-3GKHBFT PLH-3GKHBFT
PLH-5GKHSBFT PLH-5GKHSBFT
Ceiling SuspendedSeries PCH
PCH-3GKHAFT PCH-3GKHAFT
PCH-5GKHSAFT PCH-5GKHSAFT
Wall MountedSeries PKH
PKH-1.6FKHAFT PKH-1.6FKHAFT
PKH-3FKHAFT PKH-3FKHAFT
PUH-1.6VKAFT PUH-1.6VKAFT
PUH-3VKAFT PUH-3VKAFT
PUH-5YKSAFT PUH-5YKSAFT

2
1 CHANGE POINT
Differentia with the standard type.
1.1.Indoor unit
1) PLH-KKHCFT Series
Type
PLH-KKHCFT PLH-KKHC
Items
Refrigerant
Heat exchanger
Use low residual oil piping
Coppaer piping for refrigerant
R407C R22
2) PLH-GHKBFT Series
Type
PLH-GHHBFT PLH-GKHB
Items
Refrigerant
Heat exchanger
Capillaly tube
3GKHBFT
5GKHSBFT
Use low residual oil piping
{4.0O{2.2–L850mm
{4.0O{2.6–L690mm
Coppaer piping for refrigerant
{4.0O{2.0–L400mm
{4.0O{2.0–L350mm
R407C R22
3) PCH-GHKAFT Series
Type
PCH-GKHAFT PCH-GKHA
Items
Refrigerant
Heat exchanger
Capillaly tube
3GKHBFT
5GKHSBFT
Use low residual oil piping
{4.0O{2.2–L400mm
{4.0O{2.8–L860mm
Coppaer piping for refrigerant
{4.0O{2.0–L280mm
{4.0O{2.4–L270mm
R407C R22
4) PKH-FHKAFT Series
Type
PKH-FKHAFT PKH-FKHA
Items
Refrigerant
Heat exchanger
Capillaly tube
3FKHAFT only
Use low residual oil piping
{4.0O{2.0–L740mm
Coppaer piping for refrigerant
{4.0O{2.0–L500mm
R407C R22
4) PKH-FHKAFT Series
Type
PKH-FKHAFT PKH-FKHA
Items
Refrigerant
Heat exchanger
Compressor
Capillaly tube
Filter dryer
Ball valve
High pressure switch
Solnoid valve
Charge plug
Refrigerant charge
Rear guard
4 way valve
Controller board
1.6VKAFT
3VKAFT
5YKSAFT
3GVKAFT only
1.6VKAFT
3VKAFT
5YKSAFT
1.6VKAFT
3VKAFT
1.6VKAFT only
1.6VKAFT only
Use low residual oil piping
RE247VFC
NE52VND
ZR61KCETED
{4.0O{2.0–L940mm
Attachment to outside of
the unit.
(Packing in same package)
Self-containing unit
Self-containing unit
·
Change of rubber materials.
·Change the oil to coat
flare nut.
Addition
Valve diameter {1.8
Valve diameter {1.8
Change of rubber material.
2.3kg
Change the rear guard form.
Change of specification.
Additions of the connector
for 63H2.
Coppaer piping for refrigerant
RH247VFC
NH52VND
ZR61KCTE5
{4.0O{2.0–L1,070mm
Valve diameter {2.0
Valve diameter {2.0
2.2kg
R407C R22
–
–
–
–

3
2 SAFETY PRECAUTION
Cautions for devices that use R407C refrigerant.
· Do not use the existing refrigerant piping.
-The old refrigerant and refrigerator oil in the existing piping contains a large amount of chlorine which may cause the
refrigerator oil of the new unit to deteriorate.
· Use “low residual oil piping”.
-If there is a large amount of residual oil (hydraulic oil, etc.) inside the piping and joints, deterioration of the refrigerator oil
will result.
· Store the piping to be used during installation indoors and keep both ends of the piping sealed until just before
brazing. (Store elbows and other joints in a plastic bag.)
-If dust, dirt, or water enters the refrigerant cycle, deterioration of the oil and compressor trouble may result.
· Use Suniso 4GS or 3GS (small amount) as the refrigerator oil to coat flares and flange connection parts.
-The refrigerator oil used with the air conditioner is highly hygroscopic. If it is used, water may be mixed in and deterioration
of the refrigerator oil may result.
· Use liquid refrigerant to seal the system.
-If gas refrigerant is used to seal the system, the composition of the refrigerant in the cylinder will change and performance
may drop.
· Do not use a refrigerant other than R407.
-If another refrigerant (R22, etc.) is used, the chlorine in the refrigerant may cause the refrigerator oil to deteriorate.
· Use a vacuum pump with a reverse flow check valve.
-The vacuum pump oil may flow back into the refrigerant cycle and cause the refrigerator oil to deteriorate.

4
[1] Service tools
Use the below service tools as exclusive tools for R407C refrigerant.
No. Tool name Specifications
1 Gauge manifold ·Only for R407C.
·Use the existing fitting SPECIFICATIONS. (UNF7/16)
·Use high-tension side pressure of 35kgf/cm
2
or over.
2 Charge hose ·Only for R407C.
·Use pressure performance of 52kgf/cm
2
or over.
3 Electronic scale
4 Gas leak detector ·Use the detector for R134a or R407C.
5 Adapter for reverse flow check. ·Attach on vacuum pump.
6 Refrigerant charge base.
7 Refrigerant cylinder. ·For R407C ·Top of cylinder (Brown)
·Cylinder with syphon
8 Refrigerant recovery equipment.
[2] Notice on repair service
·After recovering the all refrigerator in the unit, proceed to working.
·Do not release the refrigerant in the air.
·After complete the repair service, recharge the cycle with the specified amount of the
liquid refrigerant.

5
3 COMBINATION OF INDOOR AND OUTDOOR UNITS
Indoor unit Outdoor unit
Service Ref.
PLH-GKH(S)BFT
PLH-KKHCFT
PCH-GKH(S)AFT
PKH-FKHAFT
OC096
OC123
OC135
OC130
Service
Manual No.
1.6
VKAFT
—
—
3
VKAFT
—
5
YKAFT
—
—
[3] Refrigerant recharging
(1) Refrigerant recharging process
1Direct enclosure from the bomb.
·Comfirm that R407C bomb on the market are syphon pipe.
·Leave the syphon pipe bomb raising and recharge it.
(By liquid refrigerant)
(2) Recharge in refrigerant leakage case
·After recovering the all refrigerator in the unit, proceed to working.
·Do not release the refrigerant in the air.
·After complete the repair service, recharge the cycle with the specified amount of the
liquid refrigerant.

Service Ref.
Item
Btu/h
W
kW
kW
A
A
kW
K/min(CFM)
mmAq,Pa
kW
dB(A)
mm,(in.)
mm,(in.)
mm,(in.)
mm,(in.)
kg,(lbs)
kW
A
A
kW
kW
K
/min(CFM
)
dB(A)
mm,(in.)
mm,(in.)
mm,(in.)
kg,(lbs)
kg,(lbs)
mm,(in.)
mm,(in.)
Function
Capacity
Total input
Service Ref.
Power supply(phase, cycle,voltage)
Input
Running current
Starting current
External finish
Heat exchanger
Fan(drive) x No.
Fan motor output
Airflow(Low-High)
External static pressure
Booster heater
Operation control & Thermostat
Noise level(Low-High)
Cond. drain conn. O.D.
Dimensions
Weight
Service Ref.
Power supply (phase, cycle, voltage)
Input
Running current
Starting current
External finish
Refrigerant control
Compressor
Model
Motor output
Starter type
Protection devices
Heat exchanger
Fan(drive) x No.
Fan motor output
Airflow
Defrost method
Noise level
Dimensions
Weight
Refrigerant
Charge
Pipe size O.D.
Connection method
Between the indoor &
outdoor unit
INDOOR UNITOUTDOOR UNIT
REFRIGERANT PIPING
PLH-1.6KKHCFT
Cooling
15,000
4,400
1.59
0.15
0.64
0.70
UNIT : 660(26)
UNIT : 660(26)
UNIT : 253(10)
UNIT : 19(42)[20(44)]
1.44
6.74
Heating
15,900[20,600]
4,650[6,050]
1.51[3.20]
0.10[1.50]
0.45[6.28]
0.50[6.91]
PANEL : 760(30)
PANEL : 760(30)
PANEL : 30(1-1/8)
PANEL : 3.7(8)[3.7(8)]
1.41
6.60
W
D
H
W
D
H
Liquid
Gas
Indoor side
Outdoor side
Height difference
Piping length
PLH-1.6KKHCFT
Single, 50Hz, 220-240V
Galvanized sheets with gray heat insulation
Plate fin coil
Turbo fan [direct) x 1
0.030
13-16(460-565)
0(direct blow)
[1.4]
Remote controller & built-in
32-37
32(1-1/4)
PUH-1.6VKAFT
Single, 50Hz, 220-240V
33
Munsell 5Y 7/1
Capillary tube
Hermetic
RH247VFC
1.2
Line start
Inner thermostat, High pressure switch
Plate fin coil
Propeller (direct) x 1
0.065
45(1,590)
Reverse cycle
49
870(34-1/4)
295+24 (11-5/8 and 1)
650 (25-5/8)
53(117)
R407C
2.3(5.1)
9.52 (3/8)
15.88 (5/8)
Flared
Flared
Max. 40m
Max. 40m

Service Ref.
Power supply(phase, cycle,voltage)
External finish
Heat exchanger
Booster heater
Operation control & Thermostat
Noise level(Low-High)
Cond. drain conn. O.D.
Dimensions
Weight
Service Ref.
Power supply (phase, cycle, voltage)
External finish
Refrigerant control
Compressor
Heat exchanger
Defrost method
Noise level
Dimensions
Weight
Refrigerant
Pipe size O.D.
Connection method
Between the indoor & outdoor units
Input
Running current
Starting current
Fan(drive) x No.
Fan motor output
Airflow(Low-High)
External static pressure
Input
Running current
Starting current
Model
Motor output
Starter type
Protection devices
Fan(drive) x No.
Fan motor output
Airflow
Charge
W
D
H
W
D
H
Liquid
Gas
Indoor side
Outdoor side
Height difference
Piping length
Function
Capacity
Total input
INDOOR UNITOUTDOOR UNIT
REFRIGERANT
PIPING
Item
Models
Btu/h
W
kW
kW
A
A
kW
K/ min (CFM)
Pa(mmAq)
kW
dB(A)
mm,(in)
mm,(in)
mm,(in)
mm,(in)
kg,(lbs)
kW
A
A
kW
kW
K/ min (CFM)
dB(A)
mm,(in)
mm,(in)
mm,(in)
kg,(lbs)
kg,(lbs)
mm,(in)
mm,(in)
PLH-3GKHBFT
Cooling
26,300
7,700
3.57
Heating
28,700[35,800]
8,400[10,500]
3.59[5.69]
0.16
0.72
1.00
0.16[2.26]
0.72[9.5]
1.00[9.8]
UNIT : 820(32-1/4)
UNIT : 820(32-1/4)
UNIT : 258(10-1/8)
UNIT : 29(64)
PANEL : 950(37-3/8)
PANEL : 950(37-3/8)
PANEL : 65(2-9/16)
PANEL : 7(16)
3.41
4.96/15.58
58/37
3.43
5.04/5.61
58/37
PLH-3GKHBFT
Single, 50Hz, 220-240V
Galvanized sheets with gray heat insulation
Plate fin coil
Turbo fan (direct) x 1
0.050
14-18(495-640)
0(direct blow)
[2.1]
Remote controller & built-in
32-39
30(1-1/4)
PUH-3VKAFT
Single, 50Hz, 220-240V/3, 50Hz, 380-415V(4wires)
Munsell 5Y 7/1
Capillary tube
Hermetic
NE-52VND
2.2/2.4
Line start
w1
Plate fin coil
Propeller (direct) x1
0.085
50(1764)
Reverse cycle
52
870(34-1/4)
295+24 (11-5/8 add 1)
850(34-1/4)
75(165)
R407C
3.2(7.1)
9.52 (3/8)
15.88(5/8)
Flared
Flared
Max. 50m
Max. 50m
w1 V…Internal Thermostat, HP switch
Y…Anti-phase protector, thermal relay, thermal switch, HP switch

Service Ref.
Power supply(phase, cycle,voltage)
External finish
Heat exchanger
Booster heater
Operation control & Thermostat
Noise level(Low-High)
Cond. drain conn. O.D.
Dimensions
Weight
Service Ref.
Power supply (phase, cycle, voltage)
External finish
Refrigerant control
Compressor
Heat exchanger
Defrost method
Noise level
Dimensions
Weight
Refrigerant
Pipe size O.D.
Connection method
Between the indoor & outdoor units
Input
Running current
Starting current
Fan(drive) x No.
Fan motor output
Airflow(Low-High)
External static pressure
Input
Running current
Starting current
Model
Motor output
Starter type
Protection devices
Fan(drive) x No.
Fan motor output
Airflow
Charge
W
D
H
W
D
H
Liquid
Gas
Indoor side
Outdoor side
Height difference
Piping length
Function
Capacity
Total input
INDOOR UNITOUTDOOR UNIT
REFRIGERANT
PIPING
Item
Models
Btu/h
W
kW
kW
A
A
kW
K/ min (CFM)
Pa(mmAq)
kW
dB(A)
mm,(in)
mm,(in)
mm,(in)
mm,(in)
kg,(lbs)
kW
A
A
kW
kW
K/ min (CFM)
dB(A)
mm,(in)
mm,(in)
mm,(in)
kg,(lbs)
kg,(lbs)
mm,(in)
mm,(in)
PLH-5GKHSBFT
Cooling
41,300
12,100
4.55
Heating
45,700[56,000]
13,400[16,400]
4.77[7.77]
0.28
1.27
1.50
0.28[3.28]
1.27[13.8]
1.50[14.0]
UNIT : 1340(52-3/4)
UNIT : 820(32-1/4)
UNIT : 258(10-1/8)
UNIT : 45(99)
PANEL : 1470(57-7/8)
PANEL : 950(37-3/8)
PANEL : 65(2-9/16)
PANEL :10(22)
4.27
6.90
53
4.49
7.34
53
PLH-5GKHSBFT
Single, 50Hz, 220-240V
Galvanized sheets with gray heat insulation
Plate fin coil
Turbo fan (direct) x 2
0.050+0.050
24-33(850-1165)
0(direct blow)
[3.0]
Remote controller & built-in
36-43
30(1-1/4)
PUH-5YKSAFT
3, 50Hz, 380-415V(4wire)
Munsell 5Y 7/1
Capillary tube
Hermetic
ZR61KCE-TFD
3.5
Line start
Internal thermostat, Anti-phasa protector, Thermal switch, HP switch
Plate fin coil
Propeller (direct) x2
0.085+0.085
95(3550)
Reverse cycle
55
970(38-3/16)
345+24(13-9/16 add 1)
1258(49-1/2)
114(251)
R407C
5.4(11.9)
9.52(3/8)
19.05(3/4)
Flared
Flared
Max. 50m
Max. 50m

9
Rating Conditions (JIS B8616)
Service Ref.
Power supply
External finish
Heat exchanger
Booster heater
Operation control & Thermostat
Noise level(Low-High)
Cond. drain connection O.D.
Dimensions
Weight
Service Ref.
Power supply
External finish
Refrigerant control
Compressor
Heat exchanger
Defrost method
Crankcase heater
Noise level
Dimensions
Weight
Refrigerant
Pipe size O.D.
Connection method
Between the indoor & outdoor unit
Indoor side
Outdoor side
Height difference
Piping length
Input
Running current
Starting current
Fan(drive))No.
Fan motor output
Airflow(Low-High)
External static pressure
Input
Running current
Starting current
Model
Motor output
Starter type
Protection devices
Fan(drive))No.
Fan motor output
Airflow
Charge
dB(A)
mm,(in)
mm,(in)
mm,(in)
mm,(in)
kg,(lbs)
W
D
H
Function
Total input
Capacity
Cooling
Heating
Upper limit
Lower limit
Upper limit
Lower limit
Indoor
35: DB, 22.5: WB
21: DB, 15.5: WB
27: DB
20: DB
Outdoor
46: DB
-5: DB
21: DB, 15.5: WB
-8.5: DB, -9.5: WB
2. Guaranteed operating range
W
dB(A)
mm,(in)
mm,(in)
mm,(in)
kg,(lbs)
W
D
H
INDOOR UNITOUTDOOR UNIT
REFRIGERANT
PIPING
Item
Service Ref.
Btu/h
W
kW
kW
A
A
kW
A
A
kW
kg,(lbs)
kW
K/min <CFM>
kW
K/min <CFM>
Pa(mmAq)
kW
mm,(in)
mm,(in)
Liquid
Gas
PCH-3GKHAFT PCH-4GKHSA1
Cooling
25,600
7,500
3.28
0.13
0.55
1.27
0.13 (2.23)
0.55 (9.30)
1.27 (10.02)
0.16
0.70
1.48
0.16 (2.86)
0.70 (11.95)
1.48 (12.73)
Heating
29,000 (36,200)
8,500 (10,600)
3.07 (5.17)
Cooling
34,100
10,000
3.36
Heating
35,700 (44,900)
10,450 (13,150)
3.35(6.05)
PCH-3GKHAFT
Single phase. 50Hz. 220-240V
Munsell 0.70Y 8.59 / 0.97
Plate fin coil
Sirocco (direct) ✕ 3
PCH-4GKHSA
1
0.07
14 -18 <494-635>
0.09
20 -25 <706-883>
0 (direct blow)
(2.1)
210 (8-1/4) 270 (10-5/8)
(2.7)
Remote controller & built-in
37 - 43 40 - 45
26 (1)
1,310 ( 51-9/16 )
680 (26-3/4)
36 (79)
PUH-3VKAFT
39.5 (87)
PUH-4YKSA
3
NH52YDA
2.2 / 2.4
NH56YDA
2.7
Propeller (direct) ✕ 1
0.085
50 (1,764)
Propeller (direct) ✕ 2
0.065 + 0.065
95 (3,350)
850 (33-7/16)
75 (165)
1,258 (49-1/2)
94 (207)
Max. 50m
Max. 50m
38
52
38
54
3.2 (7.1)
9.52 (3/8)
15.88 (5/8)
4.2 (9.2)
9.52 (3/8)
19.05 (3/4)
VKA...1phase, 50Hz, 220-240V
Reverse cycle
R407C
870 <34-1/4>
295 + 24 <11-5/8 add 1>
Munsell 5Y 7/1
Capillary tube
Hermetic
Line start
VKA...Inner thermostat. High-pressure switch YKA...Anti-phase protector, Thermal relay, Thermal switch, High-pressute switch
Plate fin coil
3.15
13.82 / 5.16
58 / 37
2.94
12.89 / 4.81
58 / 37
3.20
5.24
40
3.19
5.22
40
Flared
Flared
Notes1. Rating Conditions (JIS B8616)
Cooling : Indoor : 27:(80
o
F)DB. 19:(66oF)WB
Outdoor : 35:(95
o
F)DB. 24:(75oF)WB
Heating : Indoor : 20:(68
o
F)
Outdoor : 7:(45
o
F)DB. 6:(43oF)WB.
Refrigerant piping length (one way) : 5m(16ft)
3. Above data based on indicated voltage
Indoor Unit 1 phase 240V 50Hz
Outdoor Unit 1 phase 240V 50Hz / 3 phase 415V 50Hz

10
Rating Conditions (JIS B8616)
Service Ref.
Power supply
External finish
Heat exchanger
Booster heater
Operation control & Thermostat
Noise level(Low-High)
Cond. drain connection O.D.
Dimensions
Weight
Service Ref.
Power supply
External finish
Refrigerant control
Compressor
Heat exchanger
Defrost method
Crankcase heater
Noise level
Dimensions
Weight
Refrigerant
Pipe size O.D.
Connection method
Between the indoor & outdoor unit
Indoor side
Outdoor side
Height difference
Piping length
Input
Running current
Starting current
Fan(drive))No.
Fan motor output
Airflow(Low-High)
External static pressure
Input
Running current
Starting current
Model
Motor output
Starter type
Protection devices
Fan(drive))No.
Fan motor output
Airflow
Charge
dB(A)
mm,(in)
mm,(in)
mm,(in)
mm,(in)
kg,(lbs)
W
D
H
Function
Total input
Capacity
Cooling
Heating
Upper limit
Lower limit
Upper limit
Lower limit
Indoor
35: DB, 22.5: WB
21: DB, 15.5: WB
27: DB
20: DB
Outdoor
46: DB
-5: DB
21: DB, 15.5: WB
-8.5: DB, -9.5: WB
2. Guaranteed operating range
W
dB(A)
mm,(in)
mm,(in)
mm,(in)
kg,(lbs)
W
D
H
INDOOR UNITOUTDOOR UNIT
REFRIGERANT
PIPING
Item
Service Ref.
Btu/h
W
kW
kW
A
A
kW
A
A
kW
kg,(lbs)
kW
K/min <CFM>
kW
K/min <CFM>
Pa(mmAq)
kW
mm,(in)
mm,(in)
Liquid
Gas
PCH-5GKHSAFT PCH-6GKHSA1
Cooling
42,300
12,400
4.45
0.24
1.06
2.20
0.24 (3.24)
1.06 (13.56)
2.20 (14.70)
0.24
1.06
2.20
0.24 (3.24)
1.06 (13.56)
2.20 (14.70)
Heating
47,400 (57,700)
13,900 (16,900)
4.40 (7.40)
Cooling
49,500
14,500
4.97
Heating
51,200 (61,400)
15,000 (18,000)
4.82 (7.82)
PCH-5GKHSAFT
Single phase. 50Hz. 220-240V
PCH-6GKHSA
1
Munsell 0.70Y 8.59 / 0.97
Plate fin coil
Sirocco (direct)✕4
0.15
27 -34 <953-1,200>
0 (direct blow)
(3.0)
Remote controller & built-in
41-46 42-48
26 (1)
1,620 (63-3/4)
680 (26-3/4)
270 (10-5/8)
46 (101)
PUH-5YSAFT
48 (106)
PUH-6YKSA
2
ZR61KC-ETED
3.5
ZR68KC-TFD
4.0
0.085 + 0.085
95 (3,350)
0.10 + 0.10
100 (3,530)
114 (251) 117 (258)
55 56
5.4 (11.9) 5.0 (11.0)
3 phases. 50Hz. 380-415V (4 wires)
Reverse cycle
38
R407C
970 (38-3/16)
345 + 24 (13-9/16 add 1)
1,258 (49-1/2)
Munsell 5Y 7/1
Capillary tube
Hermetic
Line start
Anti-phase protector, Internal thermostat, Thermal switch, High-pressure switch
Plate fin coil
Propeller (direct)✕2
4.21
6.89
53
4.16
6.81
53
4.73
7.74
74
4.58
7.50
74
9.52 (3/8)
19.05 (3/4)
Flared
Flared
Max. 50m
Max. 50m
Notes1. Rating Conditions (JIS B8616)
Cooling : Indoor : 27:(80
o
F)DB. 19:(66oF)WB
Outdoor : 35:(95
o
F)DB. 24:(75oF)WB
Heating : Indoor : 20:(68
o
F)DB.
Outdoor : 7:(45
o
F)DB. 6:(43oF)WB.
Refrigerant piping length (one way) : 5m(16ft)
3. Above data based on indicated voltage
Indoor Unit 1 phase 240V 50Hz
Outdoor Unit 3 phase 415V 50Hz

Item
Function
Capacity
Total input
Service Ref.
Power supply(phase,cycle,voltage)
External finish
Heat exchanger
Booster heater
Operation control & Thermostat
Noise level(Low-High)
Cond. drain connection. O.D.
Dimensions
Weight
Service Ref.
Power supply (phase, cycle, voltage)
External finish
Refrigerant control
Compressor
Heat exchanger
Defrost method
Noise level
Dimensions
Weight
Refrigerant
Pipe size O.D.
Connection method
Between the indoor & outdoor unit
Input
Running current
Starting current
Fan(drive) ✕ No.
Fan motor output
Airflow(Low-High)
External static pressure
Input
Running current
Staring current
Model
Motor output
Starter type
Protection devices
Fan(drive)✕No.
Fan motor output
Airflow
Charge
Service Ref.
W
D
H
W
D
H
Liquid
Gas
Indoor side
Outdoor side
Height difference
Piping length
INDOOR UNITOUTDOOR UNIT
REFRIGERANT PIPING
W
Btu/h
kW
kW
A
A
kW
m
3
/X<CFM>
Pa(mmAq)
kW
>(A)
A,<in.>
A,<in.>
A,<in.>
A,<in.>
kg,<lbs>
>(A)
A,<in.>
A,<in.>
A,<in.>
A,<in.>
A,<in.>
kg,<lbs>
kg,<lbs>
kW
A
A
kW
kW
m
3
/X,<CFM>
PKH-1.6FKHAFT
Cooling Heating
4,500 4,650(6,050)
15,350 15,900(20,600)
1.51
0.07
0.32
0.40
PKH-1.6FKHAFT
Single, 50Hz, 220-240V
Munsell 3.4Y 7.7/0.8(White)
Plate fin coil
Line flow(direct) ✕ 1
0.030
10-13<353-459>
0<direct blow>
1.4
Remote controller & built-in
36-43
20<13/16>
1,250<49-3/16>
200<7-7/8>
300<11-13/16>
18<40>
PUH-1.6VKAFT
Single, 50Hz, 220-240V
1.411.44
6.606.74
33
Munsell 5y 7/1
Capillary tube
Hermetic
RE247VFC
1.2
Line start
Internal thermostat, HP switch
Plate fin coil
Propeller (direct) ✕ 1
0.065
45<1,590>
Reverse cycle
49
870<34-1/4>
295+24<11-5/8 add 1>
650<25-5/8>
53<117>
R-407C
2.3<5.1>
9.52<3/8>
15.88<5/8>
Flared
Flared
Max. 40m
Max. 40m
1.48(2.88)
0.07(1.47)
0.32(6.15)
0.40(6.23)
Note. Rating Conditions (JIS B 8616)
Cooling : Indoor : 27°C (80°C) DB, 19°C (66°F) WB
Outdoor : 35°C (95°F) DB, 24°C (75°F) WB
Heating : Indoor : 20°C (68°F)
Outdoor : 7°C (45°F) DB, 6°C (43°F) WB

Item
Function
Capacity
Total input
Service Ref.
Power supply(phase,cycle,voltage)
External finish
Heat exchanger
Booster heater
Operation control & Thermostat
Noise level(Low-High)
Cond. drain conn. O.D.
Dimensions
Weight
Service Ref.
Power supply (phase, cycle, voltage)
External finish
Refrigerant control
Compressor
Heat exchanger
Defrost method
Noise level
Dimensions
Weight
Refrigerant
Pipe size O.D.
Connection method
Between the indoor & outdoor unit
Input
Running current
Starting current
Fan(drive) ✕ No.
Fan motor output
Airflow(Low-High)
External static pressure
Input
Running current
Staring current
Model
Motor output
Starter type
Protection devices
Fan(drive)✕No.
Fan motor output
Airflow
Charge
Service Ref.
W
D
H
W
D
H
Liquid
Gas
Indoor side
Outdoor side
Height difference
Piping lenghth
INDOOR UNITOUTDOOR UNIT
REFRIGERANT PIPING
W
Btu/h
kW
kW
A
A
kW
m
3
/X<CFM>
Pa(mmAq)
kW
>(A)
A,<in.>
A,<in.>
A,<in.>
A,<in.>
kg,<lbs>
>(A)
A,<in.>
A,<in.>
A,<in.>
A,<in.>
A,<in.>
kg,<lbs>
kg,<lbs>
kW
A
A
kW
kW
m
3
/X<CFM>
PKH-3FKHAFT
Cooling Heating
7,900 9,100(11,200)
27,000 31,000(38,200)
3.25
0.095
0.44
0.80
PKH-3FKHAFT
Single, 50Hz, 220-240V
Munsell 3.4Y 7.7/0.8(White)
Plate fin coil
Line flow(direct) ✕ 2
0.040
15-20<530-706>
0(direct blow)
2.1
Remote controller & built-in
35-43
20<13/16>
1,400<55-1/8>
235<9-1/4>
340<13-3/8>
26<57>
PUH-3VKAFT
Single, 50Hz, 220-240V/3
2.94/2.943.15/3.15
12.89/4.8113.82/5.16
58/37
Munsell 5Y 7/1
Capillary tube
Hermetic
NE52VND
2.2
Line start
Internal thermostat, HP switch/Thermal relay, thermal switch
Plate fin coil
Propeller (direct) ✕ 1
0.085
50<1,764>
Reverse cycle
52
870(34-1/4)
295+24<11-5/8 add 1>
850<33-7/16>
75<165>
R-407C
3.2<7.1>
9.52<3/8>
15.88<5/8>
Flared
Flared
Max. 50m
Max. 50m
3.04(5.14)
0.095(2.195)
0.44(9.19)
0.80(9.55)
Note. Rating Conditions (JIS B 8616)
Cooling : Indoor : 27°C (80°C) DB, 19°C (66°F) WB
Outdoor : 35°C (95°F) DB, 24°C (75°F) WB
Heating : Indoor : 20°C (68°F)
Outdoor : 7°C (45°F) DB, 6°C (43°F) WB

13
1. REFILLING REFRIGERANT CHARGE (R-22 : kg)
PUH-1.6VKAFT
PUH-3VKAFT
PUH-5YKSAFT
5m
1.6
2.5
4.7
Service Ref.
Refrigerant piping length (one way)
10m
1.8
2.7
4.8
15m
1.9
2.8
5.0
20m
2.0
2.9
5.1
25m
2.2
3.1
5.3
30m
2.3
3.2
5.4
35m
2.4
3.3
5.6
40m
2.5
3.4
5.7
45m
—
3.6
5.9
50m
—
3.7
6.0
2. COMPRESSOR TECHNICAL DATA at 20˚C
at 25˚C
Winding
Resistance
(!)
U-V
(
R-C
)
U-W
(
S-C
)
W-V
Compressor Model
RE247VFC NE52VND
Winding
Resistance
(!)
ZR61KCETED
T1-T2
T2-T3
T3-T1
Compressor Model
4.2.Outdoor unit

14
5 WIRING DIAGRAM
PUH-1.6VKAFT
Main functions of LED
(
when both Nos.1 and 2 of are “OFF”
)
NOTE : If the operation stops to function of the protection device, the check display flashes.
●
Connect the lead wires accordling to the color indication of sticker on the compressor terminal.
●
Since LD8 lights when normal power is turned “ON”, check the power supply with the “ON” or “OFF” LD8.
❈
Since the transformer (T) is connected with 240V power, if 220V or 230V power is used, change the wiring connection
in the following procedure.
●
Since the indoor and outdoor connecting wires has polarity, make sure to connect the same terminal numbers (1,2,3) for indoor and outdoor units.
How to use SW1 and 2
●
Pressing erases the past check contents loaded on the
microcomputer.
●
The output display (light) remains lit during operation but
pressing displays the past check contents in flashing
mode. Pressing the switch again returns to output display
(light).
SW3
SW1
SW2
LED No.
LD1
LD2
LD3
LD4
LD5
LD6
LD7
LD8
Output display (light
)
Compressor indoor command
Heating indoor command
63H1 ON
Compressor ON
Outdoor fan ON
4-way valve ON
Bypass valve ON
Crankcase heater ON
Check display (flash
)
–
–
Pipe sensor short/open
63H2 functions
–
–
RT overheat protection
Defective input
CAUTIONS FOR POWER SUPPLY WIRING
CAUTION FOR SERVICING
CAUTION FOR INDOOR AND OUTDOOR CONNECTING WIRES
SYMBOL
MC
MF
C1
C2
RT
HC
52C
21S4
21R
NAME
COMPRESSOR
OUTDOOR FAN MOTOR (INNER THERMOSTAT)
FAN MOTOR CAPACITOR
COMPRESOR CAPACITOR
PIPE TEMP. THERMISTOR
CRANKCASE HEATER
CONTACTOR
4-WAY VALVE SOLENOID COIL
BYPASS VALVE SOLENOID COIL
SYMBOL
TB1,3
63H1
63H2
O.B
ZNR<O.B
>
F<O.B
>
FC<O.B
>
X11<O.B
>
T
NAME
TERMINAL BLOCK
CONTROL HIGH PRESSURE SWITCH
PROTECT HIGH PRESSURE SWITCH
OUTDOOR CONTROLLER BOARD
SURGE ABSORBER
FUSE(6.3A
)
FAN CONTROLLER
CRANKCASE HEATER RELAY
TRANSFORMER
SYMBOL
X12<O.B
>
X13<O.B
>
X14<O.B
>
X16
SW1,2,3<O.B
>
LD1-LD8<O.B
>
NAME
COMPRESSOR RELAY
SOLENOID COIL RELAY
SOLENOID COIL RELEY
HIGH PRESSURE RELAY
CHECK,SERVICE SELECT SWITCH
CHECK,SERVICE LED
TO INDOOR UNIT
CONNECTING WIRES
DC 12V (polar)
POWER SUPPLY
~/N(1phase)
220V-240V 50Hz
1
YLW
2
ORN
3
BRN
TB3
BRN AC12.3V
RED AC12.3V
O.B
SW1
SW2
SW3
12
3
CN3
2
1
CN4T
YLW
240V
ORN
230V
RED
220V
T
TB1
L
N
GRN/YLW
LD1
OFF
ON
LD2
1234
LD3
4
LED
LD4
LD5
LD6
RED
RED
BLU
RT
CN2
LD7
LD8
X14
TRF 52C
SV
WHT
WHT
RED
21R
RED
BLU
52C
L1/1
L3/5
BLU
T1/2
T3/6
X13X14
21S4
BLU
21
S4
GRY
BLU
WHT
RED
GRY
52C
X16
X11X12
A1
A2
GRY
7
8
6
C2
WHT
X16
WHT
CH
CN4
HC
GRY
2
GRY
RED
X11X12X13
ZNR
63H2
1234
F
R/1 S/2 T/3
R
C
MC
S
63H1
BLU BLU
BRN
BRN5YLW
63H1
YLW
YLW
YLW
FC
BLU
26C
63H2
51CM
MF
VLT
BLU
WHT
RED
ORN
VLT
MF2
MF1
1
X16
5
BLU
WHT
4
RED
3
2
C1
1
ORN
❈When power supply is 220V
RED WHITE
220V
ORANGE
YELLOW
230V
240V

15
PUH-3VKAFT
Main functions of LED
(
when both Nos.1 and 2 of are “OFF”
)
NOTE : If the operation stops to function of the protection device, the check display flashes.
●
Connect the lead wires accordling to the color indication of sticker on the compressor terminal.
●
Since LD8 lights when normal power is turned “ON”, check the power supply.
❈
Since the transformer (T) is connected with 240V power, if 220V or 230V power is used, change the wiring connection
in the following procedure.
●
Since the indoor and outdoor connecting wires has polarity, make sure to connect the same terminal numbers (1,2,3) for indoor and outdoor units.
How to use SW1 and 2
●
Pressing erases the past check contents loaded on the
microcomputer.
●
The output display (light) remains lit during operation but
pressing displays the past check contents in flashing
mode. Pressing the switch again returns to output display
(light).
SW3
SW1
SW2
LED No.
LD1
LD2
LD3
LD4
LD5
LD6
LD7
LD8
Output display (light
)
Compressor indoor command
Heating indoor command
63H1 ON
Compressor ON
Outdoor fan ON
4-way valve ON
Bypass valve ON
Crankcase heater ON
Check display (flash
)
–
–
Pipe sensor short/open
63H2 functions
–
–
TH overheat protection
Defective input
CAUTIONS FOR POWER SUPPLY WIRING
CAUTION FOR SERVICING
CAUTION FOR INDOOR AND OUTDOOR CONNECTING WIRES
SYMBOL
MC
MF
C1
C2
TH
HC
52C
21S4
21R
NAME
COMPRESSOR
OUTDOOR FAN MOTOR (INNER THERMOSTAT)
FAN MOTOR CAPACITOR
COMPRESOR CAPACITOR
PIPE TEMPERATURE THERMISTOR
CRANKCASE HEATER
CONTACTOR
4-WAY VALVE SOLENOID COIL
BYPASS VALVE SOLENOID COIL
SYMBOL
TB1,3
63H1
63H2
O.B
ZNR<O.B
>
F<O.B
>
FC<O.B
>
X11<O.B
>
T
NAME
TERMINAL BLOCK
CONTROL HIGH PRESSURE SWITCH
PROTECT HIGH PRESSURE SWITCH
OUTDOOR CONTROLLER BOARD
SURGE ABSORBER
FUSE(6.3A
)
FAN CONTROLLER
CRANKCASE HEATER RELAY
TRANSFORMER
SYMBOL
X12<O.B
>
X13<O.B
>
X14<O.B
>
X16
SW1,2,3<O.B
>
LD1-LD8<O.B
>
CN3<O.B
>
CN4T<O.B
>
NAME
COMPRESSOR RELAY
SOLENOID COIL RELAY
SOLENOID COIL RELEY
HIGH PRESSURE RELAY
CHECK,SERVICE SELECT SWITCH
CHECK,SERVICE LED
CONNECTING WIRES
INDOOR/OUTDOOR CONNECTOR
TRANSFORMER CONNECTOR
TO INDOOR UNIT
CONNECTING WIRES
DC 12V
POWER SUPPLY
~/N(1phase)
220V-240V 50Hz
1
YLW
2
ORN
3
BRN
TB3
RED
RED
AC12.3V
AC
12.3V
TB1
L
N
BRN
BRN
T
GRN/YLW
O.B
SW1
SW2
SW3
4
YLW
ORN
RED
LED
12
3
2
1
LD1
OFF
ON
CN3
CN4T
240V
230V
220V
BLU
LD7
LD6
LD5
LD4
LD3
LD2
CN2
123
4
RED
WHT
WHT
TH
LD8
RED
21R
SV
RED
RED
BLU
1234
CN4
X12X13X14
X11
X11X12X13X14
A1
A2
GRY
7
8
WHT
6
BLU
WHT
RED
WHT
X16
C2
CH
GRY
HC
GRY
2
RED
ZNR
63H2
C
TRF
BLU
BLU
L1/1
L3/5
21S4
21
S4
GRY
52C
52C
GRY
52C
X16
T1/2
T2/6
YLW
F. C
MF2
MF1
5
BLU
VLT
VLT
YLW
YLW
1
X16
5
C1
WHT
BLU
RED
ORN
WHT
3
BLU
4
RED
MF
2
ORN
1
26C
63H2
63H1
51CM
ST
F
R
YLW
BRN
BRN
BLUBLU
63H1
R
MC
S
❈When power supply is 220V
RED WHITE
220V
ORANGE
YELLOW
230V
240V

16
PUH-5YKSAFT
Main functions of LED
(
when both Nos.1 and 2 of are “OFF”
)
NOTE : If the operation stops to function of the protection device, the check display flashes.
●
Connect the lead wires accordling to the color indication of sticker on the compressor terminal.
●
Making wiring connection in anti-phase or missing phase “L2” or “L3” causes the protection device incorporated in the
microcomputer to function resulting in LD1 or LD2 shown in the table above to flash and prevents the compressor
operation. If phase “L1” or “N” is missing it causes all displays to go out. Under normal condition LD8 light when power
is turned “ON”. If anti-phase connection is to be used, change connections of 2 out of 3 power lines (field wiring side)
contained in the power supply terminal block (TB1) of the outdoor unit as shown at the right upper.
❈
Since the transformer (T) is connected with 240V power, if 220V or 230V power is used, change the wiring connection
in the following procedure.
●
Since the indoor and outdoor connecting wires has polarity, make sure to connect the same terminal numbers (1,2,3) for indoor and outdoor units.
How to use SW1 and 2
●
Pressing erases the past check contents loaded on the
microcomputer.
●
The output display (light) remains lit during operation but
pressing displays the past check contents in flashing
mode. Pressing the switch again returns to output display
(light).
SW3
SW1
SW2
LED No.
LD1
LD2
LD3
LD4
LD5
LD6
LD7
LD8
Output display (light
)
Compressor indoor command
Heating indoor command
63H1 ON
Compressor ON
Outdoor fan ON
4-way valve ON
Bypass valve ON
Crankcase heater ON
Check display (flash
)
Auti-phase detect
Missing-phase detect
Pipe sensor short/open
63H2 functions
–
26C functions
RT overheat protection
Defective input
CAUTIONS FOR POWER SUPPLY WIRING
CAUTION FOR SERVICING
CAUTION FOR INDOOR AND OUTDOOR CONNECTING WIRES
SYMBOL
MC
MF1,2
C1,2
TH
HC
49C
52C
21S4
21R
X16
NAME
COMPRESSOR
OUTDOOR FAN MOTOR (INNER THERMOSTAT)
FAN MOTOR CAPACITOR
PIPE TEMPERATURE THERMISTOR
CRANKCASE HEATER
INTERNAL THERMOSTAT FOR MC
CONTACTOR
4-WAY VALVE SOLENOID COIL
BYPASS VALVE SOLENOID COIL
HIGH PRESSURE RELAY
SYMBOL
TB1,3
63H1
63H2
26C
O.B
ZNR<O.B
>
F<O.B
>
FC<O.B
>
X11<O.B
>
T
NAME
TERMINAL BLOCK
CONTROL HIGH PRESSURE SWITCH
PROTECT PRESSURE SWITCH
DIS.CHARGE THERMAL SWITCH
OUTDOOR CONTROLLER BOARD
SURGE ABSORBER
FUSE(6.3A
)
FAN CONTROLLER
CRANKCASE HEATER RELAY
TRANSFORMER
SYMBOL
X12<O.B
>
X13<O.B
>
X14<O.B
>
CN3<O.B
>
CN4T<O.B
>
SW1,2,3<O.B
>
LD1-LD8<O.B
>
51CM<O.B
>
NAME
COMPRESSOR RELAY
SOLENOID COIL RELAY
SOLENOID COIL RELEY
CONNECTING WIRES
INDOOR/OUTDOOR CONNECTOR
TRANSFORMER CONNECTOR
CHECK,SERVICE SELECT SWITCH
CHECK,SERVICE LED
JUMPER CONNECTOR
TO INDOOR UNIT
CONNECTING WIRES
DC 12V
POWER SUPPLY
3N~(3phase 4wires)
380/220V-415/240V 50Hz
YLW
1
ORN
2
BRN
3
TB3
RED
RED
AC
12.3V
AC12.3V
BRN
BRN
TB1
L1
L2
L3
N
LED
O.B
SW1
SW2
SW3
12
3
2
1
CN4T
4
YLW
ORN
RED
T
GRN/YLW
OFF
ON
CN3
LD1
240V
230V
220V
LD5
LD4
LD3
LD2
123
4
13
52C
14
RED
WHT
BLU
TH
LD8
LD7
LD6
CN2
SV
RED
RED
21R
RED
WHT
WHT
RED
WHT
BLK
BLU
L2/3
L3/5
52C
1234
CN4
X11X12X13X14
X11X12X13X14
63H1
RST
F
TRF
T1/2L1/1
T2/4
T3/6
BLU
21S4
BLU
21
S4
52C
GRY
GRY
A1
52C
A2
GRY
X16
ZNR
CH
BLK
BLK
HC
GRY
7
2
6
63H2
X16
8
GRY
RED
WHT
BLU
26C
63H2
51CM
5
BRN
BRN
63H1
49C
T1
T2
T3
VLT
MC
F.C
MF2
MF1
BLK
BLK
VLT
1
X16
26C
5
C1
C2
WHT
BLU
RED
ORN
WHT
BLU
BRN
YLW
WHT
3
BLU
4
RED
2
ORN
1
WHT
3
BLU
4
RED
2
ORN
1
MF1
MF2
Power line reconnection procedure
In case of reverse rotation
Unit side
wiring
Field wiring
Change thie side
L1L2L3
123
charge 2 out of 1.
2 and 3.
(This example shows
reconnection of 1
and 2.)
❈When power supply is 220V
RED WHITE
220V
ORANGE
YELLOW
230V
240V
Outdoor unit
terminal

17
6 REFRIGERANT SYSTEM DIAGRAM
PKH-1.6FKHAFT/PUH-1.6VKAFT
PKH-3FKHAFT/PUH-3VKAFT
Unit : mm
Indoor
heat
exchanger
Indoor coil
thermistor
(RT2)
Distributor
with
strainer
PLH-1.6 (O.D.3.2 I.D.1.6-r630)
Restrictor
valve
Refrigerant pipe
(option)
9.52mm( 3.8")
(with heat insulator)
Ball valve
(with service port)
Indoor unit
Strainer
Refrigerant pipe
(option)
15.88mm( 5/8")
(with heat insulator)
Flexible tube
Flared
connection
Ball valve
Strainer
4-way valve
Oil separator
Service
port
High pressure
control switch
Outdoor unit
Outdoor heat exchanger
Outdoor coil
thermistor
(TH)
Bypass
valve
Restrictor
valve
Capillary
tube
Strainer
Compressor
Accumulator
Refrigerant flow in cooling
Refrigerant flow in heating
R.V.coil
Heating ON
Cooling OFF
PUH-1.6 (O.D.3.2 I.D.1.8 -R600)
Capillary
tube
High pressure
protect switch
Service
port
PLH-1.6KKHCFT/PUH-1.6VKAFT
Indoor unit
Indoor
heat
exchanger
Strainer
Indoor coil
thermistor
(RT1)
Distributor
with
strainer
PKH-1.6 (O.D.3.2 I.D.1.6-r700)
PKH-3 (O.D.4.0 I.D.2.2-r740)
Restrictor
valve
Capillary
tube
Refrigerant pipe
(option)
15.88mm( 5/8")
(with heat insulator)
Flexible tube
Flared
connection
Refrigerant pipe
(option)
9.52mm( 3.8")
(with heat insulator)
Ball valve
Strainer
Service
port
Accumulator
Ball valve
(with service port)
High pressure
Oil separator
4-way valve
Compressor
High pressure
control switch
PUH-1.6 (O.D.3.2 I.D.1.8 -r600)
PUH-3 (O.D.4.0 I.D.2.4 -r940)
control switch
Service
port
Outdoor unit
Outdoor heat exchanger
Bypass
valve
Restrictor
valve
Strainer
Outdoor coil
thermistor
(TH)
Capillary
tube