Mitsubishi PSH-P3GAH, PSH-P4GAH, PSH-P5GAH, PSH-P6GAH, PSA-P3GA SERVICE MANUAL

...
SPLIT-TYPE AIR CONDITIONERS
TECHNICAL & SERVICE MANUAL
2000
No. OC212
REVISED EDITION-A
Floor StandingSeries PSH/PSA
Indoor unit [Model names] [Service Ref.]
R407C
2000, 2001 2000 2001
PSH-P3GAH
PSH-P4GAH
PSH-P5GAH
PSH-P6GAH
PSA-P3GA
PSA-P4GA
PSA-P5GA
PSA-P6GA
PSH-P3GAH PSH-P3GAH1 PSH-P4GAH PSH-P4GAH1 PSH-P5GAH PSH-P5GAH1 PSH-P6GAH PSH-P6GAH1 PSA-P3GA PSA-P3GA1 PSA-P4GA PSA-P4GA1 PSA-P5GA PSA-P5GA1 PSA-P6GA PSA-P6GA1
•PSH-P3GAH1, PSH-P4GAH PSH-P5GAH PSH-P6GAH PSA-P3GA PSA-P4GA PSA-P5GA PSA-P6GA in REVISED EDITION-A.
•Please void OC212.
•Refer to the OCT03 REVISED EDITION-C as for control relation. This manual does not cover outdoor units. When serving them, please refer to the service manual No.OC180 REVISED EDITION-A, OC261 and this manual in a set.
1, 1,
1, 1, 1, 1 and 1 are added
CONTENTS
1.TECHNICAL CHANGES ························2
2.
COMBINATION OF INDOOR AND OUTDOOR UNITS
4. PART NAMES AND FUNCTIONS········5
5. SPECIFICATIONS·································9
6. DATA···················································17
7. OUTLINES AND DIMENSIONS··········45
8. WIRING DIAGRAM ·····························47
9.
REFRIGERANT SYSTEM DIAGRAM
10. TROUBLE SHOOTING·······················50
11. DISASSEMBLY PROCEDURE···········51
12. PARTS LIST········································54 13 . OPTIONAL PARTS·········BACK COVER
···2
······48
1
Heat pump type
Outdoor unit (OC180REVISED EDITION-A)
PUH-P · VGA / YGA
Cooling only type PU-P · VGA / YGA
Heat pump with electric heater
PSH-P3GAH PSH-P4GAH PSH-P5GAH PSH-P6GAH PSA-P3GA PSA-P4GA PSA-P5GA PSA-P6GA
Heat pump without electric heater or Cooling only
6Y
— — — — — — —
5Y
— — — — — —
4Y
— — — — —
— —
3Y
— — — —
— — —
3V
— — — —
— — —
6Y
— — —
— — —
5Y
— —
— — —
4Y
— — —
— —
3Y
— — —
— — —
3V
— — —
— — —
Indoor unit
Heat pump type
Outdoor unit (OC261)
PUH-P · VGAA.UK / YGAA.UK
Cooling only type
PU-P · VGAA.UK / YGAA.UK
Heat pump with electric heater
PSH-P3GAH1 PSH-P4GAH1 PSH-P5GAH1 PSH-P6GAH1 PSA-P3GA1 PSA-P4GA1 PSA-P5GA1 PSA-P6GA1
Heat pump without electric heater or Cooling only
6Y
— — — — — — —
5Y
— — — — — —
4V
— — — — —
— —
3Y
— — — —
— — —
3V
— — — —
— — —
6Y
— — —
— — —
5Y
— —
— — —
4V
— — —
— —
3Y
— — —
— — —
3V
— — —
— — —
4Y
— — — — —
— —
4Y
— — —
— —
Indoor unit
FILTER CHECK MODE TEST RUN
ON/OFF
CENTRALLY CONTROLLED
ERROR CODE
CLOCK
ON OFF
˚C
CHECK
CHECK MODE
FILTER
TEST RUN FUNCTION
˚C
1Hr.
NOT AVAILABLE
STAND BY DEFROST
TEMP.
TECHNICAL CHANGES
PSH-P3GAH ➔ PSH-P3GAH1 PSA-P3GA ➔ PSA-P3GA1
PSH-P4GAH PSH-P4GAH1 PSA-P4GA PSA-P4GA1 PSH-P5GAH PSH-P5GAH1 PSA-P5GA PSA-P5GA1 PSH-P6GAH PSH-P6GAH1 PSA-P6GA PSA-P6GA1
Outdoor units which are connected to PSH-P·GAH1 and PSA-P·GA1 have been added.
ROOM TEMPERATURE THERMISTOR has changed because it has made the lead wire longer in order to improve work
efficiency.
FAN MOTOR CAPACITOR has changed because it no longer meets the criteria of UL Standards.
FAN GUARD has changed because it has become an individual part, which was once specified as a part combined with
BELL MOUTH.
The parts No. of REMOTE CONTROLLER has changed. (The following parts numbers are interchangeable.)
[ T7W E03 713 ] [ T7W E07 713 ]
2
COMBINATION OF INDOOR AND OUTDOOR UNITS
2
3
SAFETY PRECAUTION
Cautions for using with the outdoor unit which adopts R407C refrigerant.
· Do not use the existing refrigerant piping.
-The old refrigerant and refrigerant oil in the existing piping contains a large amount of chlorine which may cause the refriger­ant oil of the new unit to deteriorate.
· Do not use copper pipes which are broken, deformed or discolour .
In addition, be sure that the inner surfaces of the pipes are clean, free of hazardous sulphur and oxides, or have no dust /
dirt, shaving particles, oils, moisture or any other contamination.
-If there is a large amount of residual oil (hydraulic oil, etc.) inside the piping and joints, deterioration of the refrigerant oil will result.
· Store the piping to be used during installation indoors and keep both ends of the piping sealed until just before brazing. (Store elbows and other joints in a plastic bag.)
-If dust, dirt, or water enters the refrigerant cycle, deterioration of the oil and compressor trouble may result.
· Use ester oil, ether oil or alkyl benzene (small amount) as the refrigerant oil to coat flares and flange connections.
-The refrigerant oil will degrade if it is mixed with a large amount of mineral oil.
Use liquid refrigerant to fill the system.
-If gas refrigerant is used to fill the system, the composition of the refrigerant in the cylinder will change and performance
may drop.
· Do not use a refrigerant other than R407C.
-If another refrigerant (R22, etc.) is used, the chlorine in the refrigerant may cause the refrigerant oil to deteriorate.
· Use a vacuum pump with a reverse flow check valve.
-The vacuum pump oil may flow back into the refrigerant cycle and cause the refrigerant oil to deteriorate.
· Do not use the following tools that are used with conventional refrigerant. (Gauge manifold , charge hose, gas leak detector, reverse flow check valve, refrigerant charge base, vacuum gauge,
refrigerant recovery equipment)
-If the conventional refrigerant and refrigerant oil are mixed in the R407C, the refrigerant may deteriorated.
-If water is mixed in the R407C, the refrigerant oil may deteriorate.
-Since R407C does not contain any chlorine, gas leak detectors for conventional refrigerant will not react to it.
· Do not use a charging cylinder.
-Using a charging cylinder may cause the refrigerant to deteriorate.
· Be especially careful when managing the tools.
-if dust, dirt, or water gets in the refrigerant cycle, the refrigerant may deteriorate.
· Do not use the drier which is sold in the field.
-The drier for R407C refrigerant is per-attached to outdoor unit refrigerant circuit.
-Some drier in the field are not in conformity with R407C refrigerant .
3
Gravimeter
Unit
[1] Service tools
Use the below service tools as exclusive tools for R407C refrigerant.
No. Tool name Specifications
1 Gauge manifold ·Only for R407C.
·Use the existing fitting SPECIFICATIONS. (UNF7/16)
·Use high-tension side pressure of 3.43MPa·G or over.
2 Charge hose ·Only for R407C.
·Use pressure performance of 5.10MPa·G or over.
3 Electronic scale 4 Gas leak detector ·Use the detector for R407C. 5 Adapter for reverse flow check. ·Attach on vacuum pump. 6 Refrigerant charge base. 7 Refrigerant cylinder. ·For R407C ·Top of cylinder (Brown)
·Cylinder with syphon
8 Refrigerant recovery equipment.
[2] Notice on repair service
·After recovering the all refrigerant in the unit, proceed to working.
·Do not release refrigerant in the air.
·After completing the repair service, recharge the cycle with the specified amount of liquid refrigerant.
[3] Refrigerant recharging
(1) Refrigerant recharging process
1Direct charging from the cylinder.
·R407C cylinder are available on the market has a syphon pipe.
·Leave the syphon pipe cylinder standing and recharge it. (By liquid refrigerant)
(2) Recharge in refrigerant leakage case
·After recovering the all refrigerant in the unit, proceed to working.
·Do not release the refrigerant in the air.
·After completing the repair service, recharge the cycle with the specified amount of liquid refrigerant.
4
4
Disperses air up and down
Disperses air left and right.
Removes dust and pollutants from intake air.
(Intakes air from room.)
PART NAMES AND FUNCTIONS
Indoor (Main) Unit
Controller
Once the controls are set, the same operation mode can be repeated by simply pressing the ON/OFF button.
PSH-P3/4/5/6GAH, PSA-P3/4/5/6GA
Operation buttons
AIR SPEED button
This sets the fan speed.
VENTILATION button
This set the ventilation fan speed.
ON/OFF button
This switches between the opera­tion and stop modes each time it is pressed. The lamp on this button lights during operation.
AIR DIRECTION button
This adjusts the vertical angle of the ventilation.
(This button does not operate in this model)
FILTER button
This resets the filter service indica­tion display.
CHECK-TEST RUN button
Only press this button to perform an inspection check or test opera­tion Do not use it for normal opera­tion.
TIMER button
This switches between continuous operation and the timer operation.
OPERATION SWITCH button
Press this button to switch the cooler electronic dry (dehumidify) automatic and heater modes.
TEMP. ADJUSTMENT button
This sets the room temperature The temperature setting can be performed in 1°C units
Setting range
Cooler 19°C to 30°C Heater 17°C to 28°C
TIMER ADJUSTMENT button
This adjust the current time, start time and stop time.
TIME SETTING button
This sets of switches the current time. start time and stop time.
LOUVER button
This switches the horizontal fan motion ON and OFF.
5
PSH-P3/4/5/6GAH, PSA-P3/4/5/6GA
Display
CENTRALLY CONTROLLED display
This indicates when the unit is con-
trolled by optional features such as central control type remote controller.
TIMER display
This indicates when the continuous
operation and time operation modes are set.
It also display the time for the timer
operation at the same time as when it is set.
OPERATION MODE display
This indicates the operation mode.
STANDBY display
This indicates when the standby
mode is set from the time the sleep operation starts until the heating air is discharged.
DEFROST display
This indicates when the defrost oper-
ation is performed.
CLOCK display
The current time , start time and stop time can be displayed in ten second intervals by pressing the time switch button. The start time or stop time is always displayed during the timer operation.
In this display example on the bot­tom left, a condition where all dis­play lamps light is shown for expla­nation purposes although this differs from actual operation.
AIR DIRECTION display
The selected fan speed is displayed.
FAN SPEED display
This displays the air direction.
ROOM TEMPERATURE display
The temperature of the suction air is displayed during operation. The dis­play range is 8° to 39°C. The display flashes 8°C when the actual temper­ature is less than 8° and flashes 39°C when the actual temperature is greater than 39°C.
Operation lamp
This lamp lights during operation, goes off when the unit stops and flashes when a malfunction occurs.
CHECK MODE
TEST RUN
This display lights in the check mode or when a test operation is per­formed.
display
CHECK display
This indicates when a malfunction
has occurred in the unit which should be checked.
SET TEMPERATURE display
This displays the selected setting temperature.
FILTER
This lamp lights when the filter need to be cleaned.
POWER display
This lamp lights when electricity is supplied to the unit.
display
Caution
Only the Power display lights when the unit is stopped and power supplied to the unit.
When power is turned ON for the first time the (CENTRAL CTRL) display appears to go off momentarily but this is not a
malfunction.
When the central control remote control unit, which is sold separately, is used the ON-OFF button, operation switch button and TEMP. adjustment button do not operate.
“NOT AVAILABLE” is displayed when the Air direction button are pressed.This indicates that this room unit is not equipped with the fan direction adjustment function and the louver function.
When power is turned ON for the first time, it is normal that “H0” is displayed on the room temperature indication (For max. 2minutes). Please wait until this “H0” indication disappear then start the operation.
6
Controller
PAR-20MAA
ON/OFF
CENTRALLY CONTROLLED
ERROR CODE
CLOCK
ON OFF
˚C
CHECK
CHECK MODE
FILTER
TEST RUN FUNCTION
˚C
1Hr.
NOT AVAILABLE
STAND BY DEFROST
FILTER
CHECK TEST
TEMP.
TIMER SET
Press this button to switch the cooler, electronic dry (dehumidify), automatic and heater modes.
OPERATION SWITCH button
This sets the room temperature. The temperature setting can be performed in 1: units Setting range Cooler 19: to 30: Heater 17: to 28:
TEMP. ADJUSTMENT button
This switches between continuous operation and the timer operation.
TIMER button
This switches between the operation and stop modes each time it is pressed. The lamp on this button lights during operation.
ON/OFF button
Only press this button to perform an inspection check or test operation. Do not use it for normal operation.
CHECK-TEST RUN button
This switch the horizontal fan motion ON and OFF.
(Not available for this model.)
This sets the ventilation fan speed.
LOUVER button VENTILATION button
This adjusts the vertical angle of the ventilation.
AIR DIRECTION button
This resets the filter service indication display
FILTER button
This sets the current time, start time and stop time.
TIME SETTING button
This sets the ventilation fan speed.
AIR SPEED button
Once the controls are set, the same operation mode can be repeated by simply pressing the ON/OFF button.
PSH-P3/4/5/6GAH1, PSA-P3/4/5/6GA1
Operation buttons
7
PSH-P3/4/5/6GAH1, PSA-P3/4/5/6GA1
PAR-20MAA
ON/OFF
CENTRALLY CONTROLLED
ERROR CODE
CLOCK
ON OFF
˚C
CHECK
CHECK MODE
FILTER
TEST RUN FUNCTION
˚C
1Hr.
NOT AVAILABLE
STAND BY DEFROST
FILTER
CHECK TEST
TEMP.
TIMER SET
Display
CENTRALLY CONTROLLED display
This indicates when the unit is con-
trolled by optional features such as central control type remote controller.
TIMER display
This indicates when the continuous
operation and time operation modes are set.
It also display the time for the timer
operation at the same time as when it is set.
OPERATION MODE display
This indicates the operation mode.
STANDBY display
The [STANDBY] symbol is only displayed from the time the heating
operation starts unit the heated air begins to blow.
DEFROST display
This indicates when the defrost oper-
ation is performed.
CLOCK display
The current time , start time and stop time can be displayed in ten second intervals by pressing the time switch button. The start time or stop time is always displayed during the timer operation.
In this display example on the bot­tom left, a condition where all dis­play lamps light is shown for expla­nation purposes although this differs from actual operation.
AIR DIRECTION display
This displays the air direction.
AIR SPEED display
The selected fan speed is displayed.
ROOM TEMPERATURE display The temperature of the suction air
is displayed during operation. The display range is 8°C to 39°C. The display flashes 8°C when the actual temperature is less than 8°C and flashes 39°C when the actual tem­perature is greater than 39°C.
Operation lamp
This lamp lights during operation, goes off when the unit stops and flashes when a malfunction occurs.
CHECK MODE
TEST RUN
This display lights in the check mode or when a test operation is per­formed.
display
FILTER display
CHECK display
This indicates when a malfunction
has occurred in the unit which should be checked.
SET TEMPERATURE display
This displays the selected setting temperature.
Caution
Only the Power display lights when the unit is stopped and power supplied to the unit.
When the central control remote control unit, which is sold separately, is used the ON-OFF button, operation switch button
and TEMP. adjustment button do not operate.
“NOT AVAILABLE” is displayed when the Air speed button are pressed.This indicates that this room unit is not equipped with the fan direction adjustment function and the louver function.
When power is turned ON for the first time, it is normal that “H0” is displayed on the room temperature indication (For max. 2minutes). Please wait until this “H0” indication disappear then start the operation.
POWER display
This lamp lights when electricity is supplied to the unit.
This lamp lights when the filter need to be cleaned.
8
SPECIFICATIONS5
Service Ref.
With Electric heater Without Electric heater
With Electric heater Without Electric heater
With Electric heater Without Electric heater
Item
Btu/h
W
kW
kW
A A
kW
K/min(CFM)
Pa(mmAq)
kW
dB mm(in.) mm(in.) mm(in.) mm(in.)
kg(lbs) kg(lbs)
A A
kW
W
kW
K
/min(CFM
)
dB
dB mm(in.) mm(in.) mm(in.)
kg(lbs) kg(lbs)
L mm(in.) mm(in.)
Function Capacity w1
Total input w1
Service Ref.
Power supply
Input w2 Running current w2
Starting current w2 External finish Heat exchanger Fan Fan(drive) x No.
Fan motor output
Airflow(Lo-Hi)
External static pressure Booster heater w2 Operation control & Thermostat Noise level(Lo-Hi) Unit drain pipe O.D. Dimensions
Weight
Service Ref.
Power supply
Running current
Starting current External finish Refrigerant control Compressor
Model
Motor output
Starter type
Protection devices Crankcase heater
Heat exchanger Fan Fan(drive) x No.
Fan motor output
Airflow Defrost method Noise level
Dimensions
Weight Refrigerant
Charge
Oil (Model) Pipe size O.D.
Connection method Between the indoor &
outdoor unit
INDOOR UNITOUTDOOR UNIT
REFRIGERANT PIPING
PSH-P3GAH PSA-P3GA
PSH-P4GAH PSA-P4GA
Cooling
26,300
7,700
3.48
0.16
0.68 –
14.64 / 5.46
Cooling
33,100
9,700
3.65
0.26
1.10 –
5.49
Heating
30,400 (37,500)
8,900 (11,000)
3.63 (5.73)
0.16 <2.26>
0.68 <9.42> –
15.43 / 5.76
Heating 37,000 (46,200) 10,850 (13,550)
3.76 (6.46)
0.26 <2.96>
0.11 <12.33> –
5.79
W
D H
Cooling Heating
W
D H
Liquid
Gas Indoor side Outdoor side Height difference Piping length
Notes1.Rating Conditions (ISO T1)
Cooling :Indoor : D.B. 27˚C(80˚F), W.B. 19˚C (66˚F) Outdoor : D.B. 35˚C(95˚F), W.B. 24˚C (75˚F) Heating :Indoor : D.B. 20˚C(68˚F) Outdoor : D.B. 7˚C(45˚F), W.B. 6˚C (43˚F) Refrigerant piping length (one way) : 5m (16ft)
3. Above data based on indicated voltage Indoor Unit Single phase 240V 50Hz Outdoor Unit Single phase 240V 50Hz / 3 phase 415V 50Hz
2. Guaranteed operating range
Upper limit Lower limit Upper limit Lower limit
Indoor D.B. 35˚C, W.B. 22.5˚C D.B. 19˚C, W.B. 15˚C
D.B. 28˚C D.B. 17˚C
Outdoor
D.B. 46˚C
D.B. -5˚C D.B. 24˚C, W.B. 18˚C D.B. -11˚C, W.B. -12˚C
Cooling
Heating
w1 : ( ) Shows the total rating when booster heater operates. w2 : < > Shows the only booster heater rating.
0.03
15-18 <530-636>
<2.1> 40-45
270(10-5/8)
45(99) 43(95)
PUH-P3VGA / PUH-P3YGA
Single phase, 50Hz, 220-230-240V / 3 phase, 50Hz, 380-400-415V(4wires)
93 / 41
NE52VNJM / NE52YDJM
2.5
Propeller (direct) x 1
0.070
50(1,770)
49 51
855(33-5/8)
82(181)
3.7(8.2)
15.88(5/8)
0.07
24-31 <847-1,059>
<2.7> 44-49
350(13-3/4)
53(117) 51(112)
PUH-P4YGA
3 phase, 50Hz, 380-400-415V(4wires)
45
NE56YDJM
2.7
Propeller (direct) x 2
0.070+0.070 85(3,000)
51 53
1,260(49-5/8)
96(212)
4.0(8.8)
19.05(3/4)
Single phase, 50Hz, 220-230-240V
Munsell 0.70Y 8.59 / 0.97
Plate fin coil
Centrifugal(direct) x 1
0(direct blow)
Remote controller & built-in
20(13/16)
600(23-5/8)
1,900(74-13/16)
Munsell 5Y 8/1
Linear Expansion Valve
Hermetic
Line start
38
Plate fin coil
Reverse cycle
900(35-7/16)
330+20(13+3/4)
R407C
1.6(Ester)MEL56
9.52(3/8) Flared
Flared
Max. 50m Max. 50m
VGA...Inner thermostat, HP switch, Discharge thermo. YGA...Thermal relay, Discharge thermo, HP switch, Anti-phase protector.
PSH-P3GAH PSA-P3GA
PSH-P4GAH PSA-P4GA
1.1.Heat pump type Rating Conditions (ISO T1)
9
Rating Conditions (ISO T1)
Service Ref.
With Electric heater Without Electric heater
With Electric heater Without Electric heater
With Electric heater Without Electric heater
Item
Btu/h
W
kW
kW
A A
kW
K/min(CFM)
Pa(mmAq)
kW
dB mm(in.) mm(in.) mm(in.) mm(in.)
kg(lbs) kg(lbs)
A A
kW
W
kW
K
/min(CFM
)
dB
dB mm(in.) mm(in.) mm(in.)
kg(lbs) kg(lbs)
L mm(in.) mm(in.)
Function Capacity w1
Total input w1
Service Ref.
Power supply
Input w2 Running current w2
Starting current w2 External finish Heat exchanger Fan Fan(drive) x No.
Fan motor output
Airflow(Lo-Hi)
External static pressure Booster heater w2 Operation control & Thermostat Noise level(Lo-Hi) Unit drain pipe O.D. Dimensions
Weight
Service Ref.
Power supply
Running current
Starting current External finish Refrigerant control Compressor
Model
Motor output
Starter type
Protection devices Crankcase heater Heat exchanger Fan Fan(drive) x No.
Fan motor output
Airflow Defrost method Noise level
Dimensions
Weight Refrigerant
Charge
Oil (Model) Pipe size O.D.
Connection method Between the indoor &
outdoor unit
INDOOR UNITOUTDOOR UNIT
REFRIGERANT PIPING
PSH-P5GAH PSA-P5GA
PSH-P6GAH PSA-P6GA
Cooling
42,700 12,500
5.62
0.30
1.26 –
8.39
Cooling
48,500 14,200
6.46
0.38
1.62 –
10.17
Heating 46,700 (57,000) 13,700 (16,700)
5.88 (8.88)
0.30 <3.00>
1.26 <12.5> –
8.74
Heating 54,600 (64,800) 16,000 (19,000)
6.50 (9.50)
0.38 <3.00>
1.62 <12.5> –
10.28
W
D H
Cooling Heating
W
D H
Liquid
Gas Indoor side Outdoor side Height difference Piping length
Notes1.Rating Conditions (ISO T1)
Cooling :Indoor : D.B. 27˚C(80˚F), W.B. 19˚C (66˚F) Outdoor : D.B. 35˚C(95˚F), W.B. 24˚C (75˚F) Heating :Indoor : D.B. 20˚C(68˚F) Outdoor : D.B. 7˚C(45˚F), W.B. 6˚C (43˚F) Refrigerant piping length (one way) : 5m (16ft)
3. Above data based on indicated voltage Indoor Unit Single phase 240V 50Hz Outdoor Unit 3 phase 415V 50Hz
2. Guaranteed operating range
Upper limit Lower limit Upper limit Lower limit
Indoor D.B. 35˚C, W.B. 22.5˚C D.B. 19˚C, W.B. 15˚C
D.B. 28˚C D.B. 17˚C
Outdoor
D.B. 46˚C
D.B. -5˚C D.B. 24˚C, W.B. 18˚C D.B. -11˚C, W.B. -12˚C
Cooling
Heating
26-33 <918-1,165>
<3.0> 46-51
53(117) 51(112)
PUH-P5YGA
79
HE86YAA
4.3
95(3,360)
53 55
27-35 <953-1,236>
<3.0> 47-52
55(121) 53(117)
PUH-P6YGA
84
HE101YAA
5.1
100(3,530)
55 57
Single phase, 50Hz, 220-230-240V
Munsell 0.70Y 8.59 / 0.97
Plate fin coil
Centnifugal (direct) x 1
0.11
0 (direct blow)
built-in
20(13/16) 600(23-5/8) 350(13-3/4)
1,900(74-13/16)
3 Phase, 50Hz, 380-400-415V(4wires)
Munsell 5Y 8/1
Linear Expansion Valve
Hermetic
Line start
Anti-phase protector, Internal thermostat, LP switch, HP switch,Thermal relay,Discharge thermo
38
Plate fin coil
Propeller (direct) x 2
0.075+0.075
Reverse cycle
1050(41-5/16)
330+20(13+3/4)
1,260(49-5/8)
122(269)
R407C
5.8(12.8)
2.0 (Ester)MEL32
9.52(3/8)
19.05(3/4) Flared Flared
Max. 50m Max. 50m
w1 : ( ) Shows the total rating when booster heater operates. w2 : < > Shows the only booster heater rating.
PSH-P5GAH PSA-P5GA
PSH-P6GAH PSA-P6GA
10
1.2.Cooling only type Rating Conditions (ISO T1)
Item
Function Capacity Total input
Service Ref.
Power supply
Input Running current
Starting current External finish Heat exchanger Fan
Booster heater
INDOOR UNIT
Operation control & Thermostat Noise level(Lo-Hi) Unit drain pipe O.D.
Dimensions
Weight
Service Ref.
Power supply
External finish Refrigerant control Compressor
Crankcase heater Heat exchanger Fan
OUTDOOR UNIT
Defrost method Noise level
Dimensions
Weight Refrigerant
Pipe size O.D.
PIPING
Connection method
Fan(drive))No.
Fan motor output
Airflow(Lo-Hi)
External static pressure
Running current
Starting current
Model
Motor output
Starter type
Protection devices
Fan(drive))No.
Fan motor output
Airflow
Charge
Compressor oil (Model)
REFRIGERANT
Between the indoor & outdoor unit
Notes1. Rating Conditions (ISO T1)
Cooling : Indoor : D.B. 27:(80
Outdoor : D.B. 35:(95
Refrigerant piping length (one way) : 5m(16ft)
Service Ref.
K/min <CFM>
W
D H
K/min <CFM>
Cooling
W
D H
Liquid Gas
Indoor side Outdoor side Height difference Piping length
o
F), W.B. 19:(66oF)
o
F), W.B. 24:(75oF)
Btu/h
W
kW
kW
A A
kW
Pa(mmAq)
kW
dB mm(in.) mm(in.) mm(in.) mm(in.)
kg(lbs)
A A
kW
W
kW
dB mm(in.) mm(in.) mm(in.)
kg(lbs)
kg(lbs)
L mm(in.) mm(in.)
PSA-P3GA PSA-P4GA
Cooling
26,300
7,700
3.48
PSA-P3GA
Single phase, 50Hz, 220-230-240V
0.16
0.68 –
Munsell 0.70Y 8.59 / 0.97
Plate fin coil
Centrifugal (direct) 1
0.03
15-18 <530-636>
0(direct blow)
built-in
40-45 44-49
20(13/16)
600( 23-5/8 )
270 (10-5/8) 350 (13-3/4)
1,900 (74-13/16)
43(95)
PU-P3VGA / PU-P3YGA
Single-phase, 50Hz, 220-230-240V / 3-phase, 50Hz,380-400-415V(4wires)
14.64 / 5.46 93 / 41
Munsell 5Y 8/1
Linear Expansion Valve
NE52VNJM / NE52YDJM
2.5
VGA...Inner thermostat. High-pressure switch Discharge thermo YGA...Anti-phase protector, Thermal relay, Discharge thermo, High-pressure switch
Propeller (direct) 1
0.070
50 (1,770)
49 51
900(35-7/16)
330 + 20(13+3/4)
855(33-5/8)
82(181)
3.7(8.2) 4.0(8.8)
1.6(Ester) MEL56
15.88(5/8) 19.05(3/4)
3-phase, 50Hz,380-400-415V(4wires)
Hermetic
Line start
38
Plate fin coil
R407C
9.52(3/8)
Flared
Flared Max. 50m Max. 50m
Cooling
33,100
9,700
3.65
PSA-P4GA
0.26
1.10 –
0.07
24-31 <847-1,059>
51(112)
PU-P4YGA
5.49
45
NE56YDJM
2.7
Propeller (direct) 2
0.070+ 0.070 85 (3,000)
1,260(49-5/8)
96(212)
2. Guaranteed operating range
Cooling
Upper limit Lower limit
Indoor D.B. 35:, D.B. 22.5: D.B. 19:, D.B. 15:
Outdoor
D.B. 46:
D.B. -5:
3. Above data based on indicated voltage Indoor Unit Single phase 240V 50Hz Outdoor Unit Single phase 240V 50Hz / 3 phase 415V 50Hz
11
Rating Conditions (ISO T1)
OUTDOOR UNIT
REFRIGERANT
PIPING
Service Ref.
Power supply
External finish Heat exchanger Fan
Booster heater Operation control & Thermostat Noise level(Lo-Hi) Unit drain pipe O.D.
Dimensions
Weight
Service Ref.
Power supply
External finish Refrigerant control Compressor
Crankcase heater Heat exchanger Fan
Defrost method Noise level
Dimensions
Weight Refrigerant
Pipe size O.D.
Connection method
Between the indoor & outdoor unit
Indoor side Outdoor side Height difference Piping length
Liquid Gas
Cooling
mm(in.) mm(in.)
kg(lbs)
dB mm(in.) mm(in.) mm(in.)
kg(lbs)
W
D H
kW
K/min <CFM>
kW
W
L
Input Running current Starting current
Fan(drive))No. Fan motor output Airflow(Lo-Hi) External static pressure
Running current Starting current
Model Motor output Starter type Protection devices
Fan(drive))No. Fan motor output Airflow
Charge Compressor oil (Model)
A A
dB mm(in.) mm(in.) mm(in.) mm(in.)
kg(lbs)
W
D H
kW
K/min <CFM>
Pa(mmAq)
kW
kW
A A
Btu/h
W
kW
Item
Service Ref.
Function
Total input
Upper limit Lower limit
Indoor D.B. 35:, W.B. 22.5: D.B. 19:, W.B. 15:
Outdoor D.B. 46: D.B. -5:
Cooling
PSA-P5GA PSA-P6GA
Cooling
42,700 12,500
5.62
0.30
1.26 –
0.38
1.62 –
Cooling
48,500 14,200
6.46
PSA-P5GA
Single phase, 50Hz, 220-230-240V
PSA-P6GA
Munsell 0.70Y 8.59 / 0.97
Plate fin coil
Cantrifugal(direct)1
0.11
0(direct blow)
built-in
46-51 47-52
26-33<918-1,165> 27-35<953-1,236>
20(13/16) 600(23-5/8) 350(13-3/4)
1900(74-13/16)
51(112)
PU-P5YGA
53(117)
PU-P6YGA
HE86YAA
4.3
HE101YAA
5.1
95(3,360) 100(3,530)
122(269)
53 55
3 phases, 50Hz, 380-400-415V (4 wires)
R407C
5.8(12.8)
2.0(Ester)MEL32
1050(41-5/16)
330+20(13+3/4)
1,260(49-5/8)
Munsell 5Y 8/1
Linear Expansion Valve
Hermetic
Line start
Anti-phase protector, Internal thermostat, LP switch, HP switch,Thermal relay,Discharge thermo
38
Plate fin coil
Propeller (direct)2
0.075+0.075
8.39 79
10.17 84
9.52(3/8)
19.05(3/4) Flared Flared
Max. 50m Max. 50m
INDOOR UNIT
Capacity
2. Guaranteed operating range
Notes1. Rating Conditions (ISO T1)
Cooling : Indoor : D.B. 27:(80
Outdoor : D.B. 35:(95
Refrigerant piping length (one way) : 5m(16ft)
3. Above data based on indicated voltage Indoor Unit Single phase 240V 50Hz Outdoor Unit 3 phase 415V 50Hz
o
F), W.B. 19:(66oF)
o
F), W.B. 24:(75oF)
12
2.1.Heat pump type Rating Conditions (ISO T1)
Service Ref.
With Electric heater Without Electric heater
With Electric heater Without Electric heater
With Electric heater Without Electric heater
Item
Btu/h
W
kW
kW
A A
kW
K/min(CFM)
Pa(mmAq)
kW
dB mm(in.) mm(in.) mm(in.) mm(in.)
kg(lbs) kg(lbs)
A A
kW
W
kW
K
/min(CFM
)
dB
dB mm(in.) mm(in.) mm(in.)
kg(lbs) kg(lbs)
L mm(in.) mm(in.)
Function Capacity w1
Total input w1
Service Ref.
Power supply
Input w2 Running current w2
Starting current w2 External finish Heat exchanger Fan Fan(drive) x No.
Fan motor output
Airflow(Lo-Hi)
External static pressure Booster heater w2 Operation control & Thermostat Noise level(Lo-Hi) Unit drain pipe O.D. Dimensions
Weight
Service Ref.
Power supply
Running current
Starting current External finish Refrigerant control Compressor
Model
Motor output
Starter type
Protection devices Crankcase heater
Heat exchanger Fan Fan(drive) x No.
Fan motor output
Airflow Defrost method Noise level
Dimensions
Weight Refrigerant
Charge
Oil (Model) Pipe size O.D.
Connection method Between the indoor &
outdoor unit
INDOOR UNITOUTDOOR UNIT
REFRIGERANT PIPING
PSH-P3GAH1 PSA-P3GA1
PSH-P4GAH1 PSA-P4GA1
Cooling
26,300
7,700
3.41
0.16
0.68 –
14.8 / 5.29
Cooling
33,000
9,700
3.78
0.26
1.10 –
15.7 / 5.55
Heating
31,700 (38,800)
9,300 (11,400)
3.48 (5.58)
0.16 <2.26>
0.68 <9.42> –
15.76 / 5.63
Heating 37,000 (46,200) 10,850 (13,550)
3.89 (6.59)
0.26 <2.96>
0.11 <12.33> –
16.58 / 5.86
W
D H
Cooling Heating
W
D H
Liquid
Gas Indoor side Outdoor side Height difference Piping length
Notes1.Rating Conditions (ISO T1)
Cooling :Indoor : D.B. 27˚C(80˚F), W.B. 19˚C (66˚F) Outdoor : D.B. 35˚C(95˚F), W.B. 24˚C (75˚F) Heating :Indoor : D.B. 20˚C(68˚F) Outdoor : D.B. 7˚C(45˚F), W.B. 6˚C (43˚F) Refrigerant piping length (one way) : 5m (16ft)
3. Above data based on indicated voltage Indoor Unit Single phase 240V 50Hz Outdoor Unit Single phase 240V 50Hz / 3 phase 415V 50Hz
2. Guaranteed operating range
Upper limit Lower limit Upper limit Lower limit
Indoor D.B. 35˚C, W.B. 22.5˚C D.B. 19˚C, W.B. 15˚C
D.B. 28˚C D.B. 17˚C
Outdoor
D.B. 46˚C
D.B. -5˚C D.B. 24˚C, W.B. 18˚C D.B. -11˚C, W.B. -12˚C
Cooling
Heating
0.03
15-18 <530-636>
<2.1> 40-45
270(10-5/8)
45(99) 43(95)
PUH-P3VGAA.UK / PUH-P3YGAA.UK
93 / 47
NE52VNJMT / NE52YDKMT
2.5
Propeller (direct) x 1
0.070
50(1,770)
49 51
855(33-5/8)
82(181)
3.3(7.3)
15.88(5/8)
0.07
24-31 <847-1,059>
<2.7> 44-49
350(13-3/4)
53(117) 51(112)
PUH-P4VGAA.UK / PUH-P4YGAA.UK
99 / 49
NE56VNJMT / NE56YDKMT
2.7
Propeller (direct) x 2
0.070+0.070 85(3,000)
51 53
1,260(49-5/8)
96(212)
4.0(8.8)
19.05(3/4)
Single phase, 50Hz, 220-230-240V
Munsell 0.70Y 8.59 / 0.97
Plate fin coil
Centrifugal(direct) x 1
0(direct blow)
Remote controller & built-in
20(13/16)
600(23-5/8)
1,900(74-13/16)
Single phase, 50Hz, 220-230-240V / 3 phase, 50Hz, 380-400-415V(4wires)
Munsell 5Y 7/1
Linear Expansion Valve
Hermetic
Line start
38
Plate fin coil
Reverse cycle
900(35-7/16)
330+20(13+3/4)
R407C
1.3(Ester)MEL56
9.52(3/8) Flared
Flared
Max. 50m Max. 50m
VGAA.UK...Inner thermostat, HP switch, Discharge thermo. YGAA.UK...Thermal relay, Discharge thermo, HP switch.
w1 : ( ) Shows the total rating when booster heater operates. w2 : < > Shows the only booster heater rating.
PSH-P3GAH
1
PSA-P3GA1
PSH-P4GAH1 PSA-P4GA1
13
Rating Conditions (ISO T1)
Service Ref.
With Electric heater Without Electric heater
With Electric heater Without Electric heater
With Electric heater Without Electric heater
Item
Btu/h
W
kW
kW
A A
kW
K/min(CFM)
Pa(mmAq)
kW
dB mm(in.) mm(in.) mm(in.) mm(in.)
kg(lbs) kg(lbs)
A A
kW
W
kW
K
/min(CFM
)
dB
dB mm(in.) mm(in.) mm(in.)
kg(lbs) kg(lbs)
L mm(in.) mm(in.)
Function Capacity w1
Total input w1
Service Ref.
Power supply
Input w2 Running current w2
Starting current w2 External finish Heat exchanger Fan Fan(drive) x No.
Fan motor output
Airflow(Lo-Hi)
External static pressure Booster heater w2 Operation control & Thermostat Noise level(Lo-Hi) Unit drain pipe O.D. Dimensions
Weight
Service Ref.
Power supply
Running current
Starting current External finish Refrigerant control Compressor
Model
Motor output
Starter type
Protection devices Crankcase heater Heat exchanger Fan Fan(drive) x No.
Fan motor output
Airflow Defrost method Noise level
Dimensions
Weight Refrigerant
Charge
Oil (Model) Pipe size O.D.
Connection method Between the indoor &
outdoor unit
INDOOR UNITOUTDOOR UNIT
REFRIGERANT PIPING
PSH-P5GAH1 PSA-P5GA1
PSH-P6GAH1 PSA-P6GA1
Cooling
42,300 12,400
5.06
0.30
1.26 –
7.60
Cooling
47,700 14,000
5.81
0.38
1.62 –
9.03
Heating 49,800 (60,000) 14,600 (17,600)
5.35 (8.35)
0.30 <3.00>
1.26 <12.5> –
8.15
Heating 58,300 (68,500) 17,100 (20,100)
6.11 (9.11)
0.38 <3.00>
1.62 <12.5> –
9.56
W
D H
Cooling Heating
W
D H
Liquid
Gas Indoor side Outdoor side Height difference Piping length
Notes1.Rating Conditions (ISO T1)
Cooling :Indoor : D.B. 27˚C(80˚F), W.B. 19˚C (66˚F) Outdoor : D.B. 35˚C(95˚F), W.B. 24˚C (75˚F) Heating :Indoor : D.B. 20˚C(68˚F) Outdoor : D.B. 7˚C(45˚F), W.B. 6˚C (43˚F) Refrigerant piping length (one way) : 5m (16ft)
3. Above data based on indicated voltage Indoor Unit Single phase 240V 50Hz Outdoor Unit 3 phase 415V 50Hz
2. Guaranteed operating range
Upper limit Lower limit Upper limit Lower limit
Indoor D.B. 35˚C, W.B. 22.5˚C D.B. 19˚C, W.B. 15˚C
D.B. 28˚C D.B. 17˚C
Outdoor D.B. 46˚C D.B. -5˚C
D.B. 24˚C, W.B. 18˚C D.B. -11˚C, W.B. -12˚C
Cooling
Heating
26-33 <918-1,165>
<3.0> 46-51
53(117) 51(112)
PUH-P5YGAA.UK
65.5
ZR61KCE-TFD
3.5
95(3,360)
55 56
4.6 (10.1)
1.690 (Ester) MMMA-POE
27-35 <953-1,236>
<3.0> 47-52
55(121) 53(117)
PUH-P6YGAA.UK
74.0
ZR72KCE-TFD
4.2
100(3,530)
57 58
4.9 (10.8)
1.774 (Ester) MMMA-POE
Single phase, 50Hz, 220-230-240V
Munsell 0.70Y 8.59 / 0.97
Plate fin coil
Centnifugal (direct) x 1
0.11
0 (direct blow)
built-in
20(13/16) 600(23-5/8) 350(13-3/4)
1,900(74-13/16)
3 Phase, 50Hz, 380-400-415V(4wires)
Munsell 5Y 7/1
Linear Expansion Valve
Hermetic
Line start
Internal thermostat, HP switch,Thermal relay,Discharge thermo
38
Plate fin coil
Propeller (direct) x 2
0.070+0.070
Reverse cycle
1050(41-5/16)
330+20(13+3/4)
1,260(49-5/8)
122(269)
R407C
9.52(3/8)
19.05(3/4) Flared Flared
Max. 50m Max. 50m
w1 : ( ) Shows the total rating when booster heater operates. w2 : < > Shows the only booster heater rating.
PSH-P5GAH
1
PSA-P5GA1
PSH-P6GAH1 PSA-P6GA1
14
2.2.Cooling only type Rating Conditions (ISO T1)
Item
Function Capacity Total input
Service Ref.
Power supply
Input Running current
Starting current External finish Heat exchanger Fan
Booster heater
INDOOR UNIT
Operation control & Thermostat Noise level(Lo-Hi) Unit drain pipe O.D.
Dimensions
Weight
Service Ref.
Power supply
External finish Refrigerant control Compressor
Crankcase heater Heat exchanger Fan
OUTDOOR UNIT
Defrost method Noise level
Dimensions
Weight Refrigerant
Pipe size O.D.
PIPING
Connection method
Fan(drive))No.
Fan motor output
Airflow(Lo-Hi)
External static pressure
Running current
Starting current
Model
Motor output
Starter type
Protection devices
Fan(drive))No.
Fan motor output
Airflow
Charge
Compressor oil (Model)
REFRIGERANT
Between the indoor & outdoor unit
Notes1. Rating Conditions (ISO T1)
Cooling : Indoor : D.B. 27:(80
Outdoor : D.B. 35:(95
Refrigerant piping length (one way) : 5m(16ft)
Service Ref.
K/min <CFM>
W D H
K/min <CFM>
Cooling
W D H
Liquid Gas
Indoor side Outdoor side Height difference Piping length
o
F), W.B. 19:(66oF)
o
F), W.B. 24:(75oF)
Btu/h
W
kW
kW
A A
kW
Pa(mmAq)
kW
dB mm(in.) mm(in.) mm(in.) mm(in.)
kg(lbs)
A A
kW
W
kW
dB mm(in.) mm(in.) mm(in.)
kg(lbs)
kg(lbs)
L mm(in.) mm(in.)
PSA-P3GA1 PSA-P4GA1
Cooling
26,300
7,700
3.41
PSA-P3GA
15-18 <530-636>
270 (10-5/8) 350 (13-3/4)
PU-P3VGAA.UK / PU-P3YGAA.UK
Single-phase, 50Hz, 220-230-240V / 3-phase, 50Hz,380-400-415V(4wires)
14.81 / 5.29
NE52VNJMT / NE52YDKMT
VGAA.UK...Inner thermostat. High-pressure switch, Discharge thermo YGAA.UK...Anti-phase protector, Thermal relay, Discharge thermo, High-pressure switch
Propeller (direct) 1
50 (1,770)
855(33-5/8)
82(181)
3.3(7.3) 4.0(8.8)
15.88(5/8) 19.05(3/4)
1
Single phase, 50Hz, 220-230-240V
0.16
0.68 –
Munsell 0.70Y 8.59 / 0.97
Plate fin coil
Centrifugal (direct) 1
0.03
0(direct blow)
built-in
40-45 44-49
20(13/16)
600( 23-5/8 )
1,900 (74-13/16)
43(95)
PU-P4VGAA.UK / PU-P4YGAA.UK
93 / 47
Munsell 5Y 7/1
Linear Expansion Valve
Hermetic
NE56VNJMT / NE56YDKMT
2.5 Line start
38
Plate fin coil
0.070
49 51
900(35-7/16)
330 + 20(13+3/4)
R407C
1.3(Ester) MEL56
9.52(3/8)
Flared
Flared Max. 50m Max. 50m
Cooling
33,000
9,700
3.78
PSA-P4GA
24-31 <847-1,059>
51(112)
15.71 / 5.55
Propeller (direct) 2
0.070+ 0.070 85 (3,000)
1,260(49-5/8)
96(212)
1
0.26
1.10 –
0.07
99 / 49
2.7
2. Guaranteed operating range
Cooling
Upper limit Lower limit
Indoor D.B. 35:, D.B. 22.5: D.B. 19:, D.B. 15:
Outdoor D.B. 46: D.B. -5:
3. Above data based on indicated voltage Indoor Unit Single phase 240V 50Hz Outdoor Unit Single phase 240V 50Hz / 3 phase 415V 50Hz
15
Rating Conditions (ISO T1)
OUTDOOR UNIT
REFRIGERANT
PIPING
Service Ref.
Power supply
External finish Heat exchanger Fan
Booster heater Operation control & Thermostat Noise level(Lo-Hi) Unit drain pipe O.D.
Dimensions
Weight
Service Ref.
Power supply
External finish Refrigerant control Compressor
Crankcase heater Heat exchanger Fan
Defrost method Noise level
Dimensions
Weight Refrigerant
Pipe size O.D.
Connection method
Between the indoor & outdoor unit
Indoor side Outdoor side Height difference Piping length
Liquid Gas
Cooling
mm(in.) mm(in.)
kg(lbs)
dB mm(in.) mm(in.) mm(in.)
kg(lbs)
W D H
kW
K/min <CFM>
kW
W
L
Input Running current Starting current
Fan(drive))No. Fan motor output Airflow(Lo-Hi) External static pressure
Running current Starting current
Model Motor output Starter type Protection devices
Fan(drive))No. Fan motor output Airflow
Charge Compressor oil (Model)
A A
dB mm(in.) mm(in.) mm(in.) mm(in.)
kg(lbs)
W D H
kW
K/min <CFM>
Pa(mmAq)
kW
kW
A A
Btu/h
W
kW
Item
Service Ref.
Function
Total input
Upper limit Lower limit
Indoor D.B. 35:, W.B. 22.5: D.B. 19:, W.B. 15:
Outdoor
D.B. 46:
D.B. -5:
Cooling
PSA-P5GA1 PSA-P6GA1
Cooling
42,700 12,400
5.06
0.30
1.26 –
0.38
1.62 –
Cooling
47,700 14,000
5.81
PSA-P5GA
1
Single phase, 50Hz, 220-230-240V
PSA-P6GA
1
Munsell 0.70Y 8.59 / 0.97
Plate fin coil
Cantrifugal(direct)1
0.11
0(direct blow)
built-in
46-51 47-52
26-33<918-1,165> 27-35<953-1,236>
20(13/16) 600(23-5/8) 350(13-3/4)
1900(74-13/16)
51(112)
PU-P5YGAA.UK
53(117)
PU-P6YGAA.UK
ZR61KCE-TFD
3.5
ZR72KCE-TFD
4.2
4.6(10.1)
1.690MMMA-POE
4.9 (10.8)
1.774MMMA-POE
95(3,360) 100(3,530)
122(269)
55 57
3 phases, 50Hz, 380-400-415V (4 wires)
R407C
1050(41-5/16)
330+20(13+3/4)
1,260(49-5/8)
Munsell 5Y 7/1
Linear Expansion Valve
Hermetic
Line start
Internal thermostat, HP switch,Thermal relay,Discharge thermo
38
Plate fin coil
Propeller (direct)2
0.070+0.070
7.60
65.5
9.03
74.0
9.52(3/8)
19.05(3/4) Flared Flared
Max. 50m Max. 50m
INDOOR UNIT
Capacity
2. Guaranteed operating range
Notes1. Rating Conditions (ISO T1)
Cooling : Indoor : D.B. 27:(80
Outdoor : D.B. 35:(95
Refrigerant piping length (one way) : 5m(16ft)
3. Above data based on indicated voltage Indoor Unit Single phase 240V 50Hz Outdoor Unit 3 phase 415V 50Hz
o
F), W.B. 19:(66oF)
o
F), W.B. 24:(75oF)
16
DATA6
Outdoor intake air D.B.(°C)
20 25 30
Indoor
Intake air
D.B.(°C)
Indoor Intake air W.B.(°C)
20 20 20 22 22 22 24 24 24 26 26 26 28 28 28 30 30 30 32 32 32 34 34 34
16 18 20 16 18 20 16 18 20 16 18 20 16 18 20 16 18 20 16 18 20 16 18 20
CA 7,623 8,162 8,778 7,623 8,162 8,778 7,623 8,162 8,778 7,623 8,162 8,778 7,623 8,162 8,778 7,623 8,162 8,778 7,623 8,162 8,778 7,623 8,162 8,778
SHC(W)
4,726 4,081 3,336 5,336 4,734 4,038 5,946 5,387 4,740 6,556 6,040 5,442 7,166 6,693 6,145 7,623 7,346 6,847 7,623 7,999 7,549 7,623 8,162 8,251
SHF
0.62
0.50
0.38
0.70
0.58
0.46
0.78
0.66
0.54
0.86
0.74
0.62
0.94
0.82
0.70
1.00
0.90
0.78
1.00
0.98
0.86
1.00
1.00
0.94
P.C.
2.78
2.84
2.92
2.78
2.84
2.92
2.78
2.84
2.92
2.78
2.84
2.92
2.78
2.84
2.92
2.78
2.84
2.92
2.78
2.84
2.92
2.78
2.84
2.92
CA 7,392 7,931 8,586 7,392 7,931 8,586 7,392 7,931 8,586 7,392 7,931 8,586 7,392 7,931 8,586 7,392 7,931 8,586 7,392 7,931 8,586 7,392 7,931 8,586
SHC(W)
4,583 3,966 3,262 5,174 4,600 3,949 5,766 5,234 4,636 6,357 5,869 5,323 6,948 6,503 6,010 7,392 7,138 6,697 7,392 7,772 7,384 7,392 7,931 8,070
SHF
0.62
0.50
0.38
0.70
0.58
0.46
0.78
0.66
0.54
0.86
0.74
0.62
0.94
0.82
0.70
1.00
0.90
0.78
1.00
0.98
0.86
1.00
1.00
0.94
P.C.
2.94
2.99
3.06
2.94
2.99
3.06
2.94
2.99
3.06
2.94
2.99
3.06
2.94
2.99
3.06
2.94
2.99
3.06
2.94
2.99
3.06
2.94
2.99
3.06
CA 7,161 7,662 8,355 7,161 7,662 8,355 7,161 7,662 8,355 7,161 7,662 8,355 7,161 7,662 8,355 7,161 7,662 8,355 7,161 7,662 8,355 7,161 7,662 8,355
SHC(W)
4,440 3,831 3,175 5,013 4,444 3,843 5,586 5,057 4,511 6,158 5,670 5,180 6,731 6,282 5,848 7,161 6,895 6,517 7,161 7,508 7,185 7,161 7,662 7,853
SHF
0.62
0.50
0.38
0.70
0.58
0.46
0.78
0.66
0.54
0.86
0.74
0.62
0.94
0.82
0.70
1.00
0.90
0.78
1.00
0.98
0.86
1.00
1.00
0.94
P.C.
3.11
3.20
3.27
3.11
3.20
3.27
3.11
3.20
3.27
3.11
3.20
3.27
3.11
3.20
3.27
3.11
3.20
3.27
3.11
3.20
3.27
3.11
3.20
3.27
1.PERFORMANCE DATA
1) COOLING CAPACITY<1>
PSH-P3GAH / PUH-P3VGA, PUH-P3YGA PSA-P3GA / PU(H)-P3VGA, PU(H)-P3YGA
Notes CA : Capacity (W) SHC(W) : Sensible heat capacity
P.C. : Power consumption (kW) SHF : Sensible heat factor
17
Outdoor intake air D.B.(°C)
35 40 45
Indoor
Intake air
D.B.(°C)
Indoor
Intake air
W.B.(°C) 20 20 20 22 22 22 24 24 24 26 26 26 28 28 28 30 30 30 32 32 32 34 34 34
16 18 20 16 18 20 16 18 20 16 18 20 16 18 20 16 18 20 16 18 20 16 18 20
CA 6,853 7,392 8,008 6,853 7,392 8,008 6,853 7,392 8,008 6,853 7,392 8,008 6,853 7,392 8,008 6,853 7,392 8,008 6,853 7,392 8,008 6,853 7,392 8,008
SHC(W)
4,249 3,696 3,043 4,797 4,287 3,684 5,345 4,879 4,324 5,894 5,470 4,965 6,442 6,061 5,606 6,853 6,653 6,246 6,853 7,244 6,887 6,853 7,392 7,528
SHF
0.62
0.50
0.38
0.70
0.58
0.46
0.78
0.66
0.54
0.86
0.74
0.62
0.94
0.82
0.70
1.00
0.90
0.78
1.00
0.98
0.86
1.00
1.00
0.94
P.C.
3.34
3.43
3.51
3.34
3.43
3.51
3.34
3.43
3.51
3.34
3.43
3.51
3.34
3.43
3.51
3.34
3.43
3.51
3.34
3.43
3.51
3.34
3.43
3.51
CA 6,545 7,161 7,700 6,545 7,161 7,700 6,545 7,161 7,700 6,545 7,161 7,700 6,545 7,161 7,700 6,545 7,161 7,700 6,545 7,161 7,700 6,545 7,161 7,700
SHC(W)
4,058 3,581 2,926 4,582 4,153 3,542 5,105 4,726 4,158 5,629 5,299 4,774 6,152 5,872 5,390 6,545 6,445 6,006 6,545 7,018 6,622 6,545 7,161 7,238
SHF
0.62
0.50
0.38
0.70
0.58
0.46
0.78
0.66
0.54
0.86
0.74
0.62
0.94
0.82
0.70
1.00
0.90
0.78
1.00
0.98
0.86
1.00
1.00
0.94
P.C.
3.58
3.69
3.76
3.58
3.69
3.76
3.58
3.69
3.76
3.58
3.69
3.76
3.58
3.69
3.76
3.58
3.69
3.76
3.58
3.69
3.76
3.58
3.69
3.76
CA 6,237 6,699 7,238 6,237 6,699 7,238 6,237 6,699 7,238 6,237 6,699 7,238 6,237 6,699 7,238 6,237 6,699 7,238 6,237 6,699 7,238 6,237 6,699 7,238
SHC(W)
3,867 3,350 2,750 4,366 3,885 3,329 4,865 4,421 3,909 5,364 4,957 4,488 5,863 5,493 5,067 6,237 6,029 5,646 6,237 6,565 6,225 6,237 6,699 6,804
SHF
0.62
0.50
0.38
0.70
0.58
0.46
0.78
0.66
0.54
0.86
0.74
0.62
0.94
0.82
0.70
1.00
0.90
0.78
1.00
0.98
0.86
1.00
1.00
0.94
P.C.
3.88
3.97
4.04
3.88
3.97
4.04
3.88
3.97
4.04
3.88
3.97
4.04
3.88
3.97
4.04
3.88
3.97
4.04
3.88
3.97
4.04
3.88
3.97
4.04
COOLING CAPACITY<2> PSH-P3GAH / PUH-P3VGA, PUH-P3YGA PSA-P3GA / PU(H)-P3VGA, PU(H)-P3YGA
Notes CA : Capacity (W) SHC(W) : Sensible heat capacity
P.C. : Power consumption (kW) SHF : Sensible heat factor
18
Loading...