Capacity
Air flow(Hi)
Dehumidification
Power outlet
Running current
Power input
Auxiliary heater
Power factor
Starting current
Fan motor current
Model
Winding
resistance(at20:)
Dimensions WOHOD
Weight
Air direction
Sound level (Hi)
Fan speed (Hi)
Fan speed regulator
RT11(at25:)
Thermistor RT12(at25:)
RT13(at25:)
Outdoor model
Outdoor air flow
Compressor motor current
Fan motor current
Model
Output
Winding
resistance(at20:)
Model
Winding
resistance(at20:)
Dimensions WOHOD
Weight
Sound level
Fan speed
Fan speed regulator
Refrigerant filling
capacity(R-22)
Refrigerating oil (Model)
NAME
VARISTOR
ROOM TEMPERATURE
THERMISTOR
INDOOR COIL
THERMISTOR (MAIN)
INDOOR COIL
THERMISTOR (SUB)
SYMBOL
SR141
TB
52C
NAME
SOLID STATE RELAY
TERMINAL BLOCK
CONTACTOR
8
MUZ-FX12RV- MODEL WIRING DIAGRAM
E1
OUTDOOR UNIT
220-240V ~
SYMBOL
CT61
C61,C62
C65
DSA61
F801
F901
IC950
IPM
LEV
L61
NOISE FILTER P.C BOARD
R65
X64
LDNF2
CT61
LD-E
GRN
DSA61
NR61
TB1
3
12V
FROM INDOOR UNIT
CONNECTING
RED
WHT
2
BLU
N
TAB61
L61
TAB62
BLU
GRN/YLW
NAME
CURRENT TRANSFORMER
SMOOTHING CAPACITOR
OUTDOOR FAN CAPACITOR
SURGE ABSORBER
FUSE (2A)
FUSE (2A)
DC/DC CONVERTER
INTELLIGENT POWER MODULE
EXPANSION VALVE COIL
CMC COIL
BLU
CN913
TAB72
SSR61
12
21S4
L63
LDNF1
WHT
RELAY
TAB71
P.C
BOARD
F901
C65
ORN
WHT
SYMBOL
L63
L64
MC
MF61
NR61
PFC
RT61
RT62
RT64
R61,62
TAB68
TAB69
CN912
CN
X61
X62
WHT
BLU
CN914
3
2
911
1
654321
LD62
LD61
4
CN779CN778
4
3
2
CN726
1
CN771
ELECTRONIC
R61
R62
C61
C62
IC950
TRANS
+
+
F801
CONTROL
BLK
RED
YLW
5
MF61
COIL
REACTOR
COMPRESSOR
OUTDOOR FAN MOTOR (INNER FUSE)
VARISTOR
POWER FACTOR CONTROL MODULE
DISCHARGE TEMPERATURE THERMIST OR
DEFROST THERMISTOR
FIN TEMPERATURE THERMIST OR
CURRENT-DETECTING RESISTOR
P.C BOARD
CN601
231
CN641
NAME
PFC
R64
6
5
4
3
2
1
-
1
2
CN642
SYMBOL
R64
R65
SSR61
TB1, TB2
X61, X62
X64
21S4
6
LEV
+
U
V
W
RT64
CN724
TAB75
TAB76
LD65
LD66
LD67
V
GRY
TB2
BLK
GRY
1
2
BLK
WHT
RED
3
RED
~
~
P
N
IPM
RT61
RT62
MC
NAME
CURRENT-DETECTING RESISTOR
CURRENT-LIMITING RESISTOR
SOLID STATE RELAY
TERMINAL BLOCK
RELAY
RELAY
REVERSING VALVE COIL
(COOLING TURN ON)
L64
BLK
21
BLK
WHT
W
U
NOTE:1. About the indoor side electric wiring refer to the indoor unit electric wiring diagram for servicing.
Height difference should be within
8m regardless of which unit,
indoor or outdoor position is high.
w Max. Height
difference 8m
Indoor
unit
Outdoor unit
Indoor
heat
exchanger
Outdoor
heat
exchanger
Flared connection
Room temperature
thermistor
RT11
Indoor coil
thermistor
RT13(sub)
Defrost
thermistor
RT62
Discharge
thermistor
RT61
Flared connection
Stop valve
Stop valve
(with service port)
Capillary tube
Capillary tube
(2 pcs)
Refrigerant flow in cooling
Compressor
Accumulator
Maffler
Muffler
Reversing valve
Refrigerant flow in heating
Refrigerant pipe [12.7
(Option)
Refrigerant pipe [6.35
(Option)
Indoor coil
thermistor
RT12(main)
Expansion
valve
[3.0o[2.0o200
[3.0o[2.0o300
REFRIGERANT SYSTEM DIAGRAM
MSZ-FX12RV -
Unit : mm
E1
MUZ-FX12RV -
E1
INDOOR UNIT
MAX. REFRIGERANT PIPING LENGTH
Additional piping
Model
Max. length :mm
A
OUTDOOR UNIT
Piping size O.D : mm
GasLiquidIndoor unitOutdoor unit
Length of connecting pipe : m
MSZ-FX12RV-
E1
12
12.76.350.430
MAX. HEIGHT DIFFERENCE
Model
E1
Outdoor unit precharged
1100
ADDITIONAL REFRIGERANT CHARGE (R-22:g)
MSZ-FX12RV-
5m
0
6m
30
Refrigerant piping length (one way)
7m
60
90
Calculation : Xg=30g /m✕ (A-5)m
9m8m
120
11m10m
180150
12m
210
10
PERFORMANCE CURVES7
The standard data contained in these specifications apply only to the operation of the air conditioner under normal conditions.
Since operating conditions vary according to the areas where these units are installed. The following information has been
provided to clarify the operating characteristics of the air conditioner under the conditions indicated by the performance curve.
(1) GUARANTEED VOLTAGE
Rated voltage : ±10% (198 ~ 242V ),50Hz
(2) AIR FLOW
Air flow should be set at MAX.
(3) MAIN READINGS
(1) Indoor intake air wet-bulb temperature ::WB
(2) Indoor discharge air wet-bulb temperature ::WB
(3) Outdoor intake air dry-bulb temperature ::DB
(4) Total input:W
(5) Indoor intake air dry-bulb temperature::DB
(6) Outdoor intake air wet-bulb temperature::WB
(7) Total input:W
Indoor air wet-bulb temperature difference on the left side of the chart on next page shows the difference between the
indoor intake air wet-bulb temperature and the indoor discharge air wet-bulb temperature for your reference at service.
E1
Cooling
}
Heating
}
How to measure the indoor air wet-bulb temperature difference
1. Attach at least 2 sets of wet-and dry-bulb thermometers to the indoor air intake as shown in the figure, and at least 2 sets
of wet-and dry-bulb thermometers to the indoor air outlet. The thermometers must be attached to the position where air
speed is high.
2. Attach at least 2 sets of dry-bulb thermometers to the outdoor air intake.
Cover the thermometers to prevent direct rays of the sun.
3. Check that the air filter is cleaned.
4. Open windows and doors of room.
5. Press the EMERGENCY OPERATION switch once (twice) to start the EMERGENCY COOL (HEAT) MODE.
6. When system stabilizes after more than 15 minutes, measure temperature and take an average temperature.
7. 10 minutes later, measure temperature again and check that the temperature does not change.
INDOOR UNIT
OUTDOOR UNIT
11
29.3
27.1
24.8
22.6
20.3
18.1
15.8
13.5
MSZ-FX12RV- E1
050100150(Hz)
0.0
0.5
1.0
1.5
Correction of Heating capacity
Capacity correction factors
The operational frequency of compressor
11.2
10.2
9.3
8.4
7.5
6.7
MSZ-FX12RV- E1
050100150(Hz)
0.0
0.5
1.0
1.5
Correction of Cooling capacity
Capacity correction factors
The operational frequency of compressor
Cooling capacity
MUZ-FX12RV -
E1
Heating capacity
NOTE:The above curves are for the heating operation without any frost.
MUZ-FX12RV -
E1
Correction of total input
2.0
1.5
1.0
0.5
Capacity correction factors
050100150(Hz)
The operational frequency of compressor
MUZ-FX12RV -
E1
MUZ-FX12RV -
E1
Correction of total input
1.5
1.0
0.5
Capacity correction factors
050100150(Hz)
The operational frequency of compressor
12
OUTDOOR LOW PRESSURE AND OUTDOOR UNIT CURRENT
(MPa • G)
(kgf/F • G)
(reference)
1832
1520
50
25
60
30
70(%)
35(:)
0.2
0.3
0.4
0.5
0.6
0.7
82Hz
2
3
4
5
6
7
8
0.8
220V
240V
1520
50
25
60
30
70(%)
35(:)
3
4
5
6
7
82Hz
32
18
6.0
5.5
5.0
4.5
4.0
3.5
3.0
2
5 10152025
240V
220V
58Hz
How to operate with fixed operational frequency of the compressor.
1. Press the EMERGENCY OPERATION switch on the front of the indoor unit , and select either the COOLmode or the
HEAT mode before starting to operate the air conditioner.
2. The compressor starts up.
The operational frequency of the compressor is 82Hz in the COOL mode and 58Hz in the HEAT mode.
3. The fan speed of the indoor unit is Hi.
4. This operation continues for 30minutes.
5. In order to release this operation, press the EMERGENCY OPERATION switch again, press any button on the remote
controller.
NOTE : The unit of pressure has been changed to MPa on the international system of units(SI unit system).
The conversion factor is: 1(MPa • G) =10.2(kgf/ff• G)
COOL operation
1 Both indoor and outdoor unit are under the same temperature/humidity condition.
Dry-bulb temperature
20
25
30
2 Air flow should be set at Hi.
3 Operational frequency : 82Hz
NOTEQ :Total capacity (kW)INPUT :Total power input (W)
E1E1
16
MICROPROCESSOR CONTROL8
Signal transmitting section
Operation display section
OPERATE /STOP
(ON /OFF)button
OPERATION SELECT button
FAN SPEED CONTROL button
ON-TIMER button
CLOCK SET button
HR. button
MIN. button
(TIME SET button)
TEMPERATURE buttons
VANE CONTROL button
OFF-TIMER button
RESET button
ON/OFF TOO
WARM
TOO
COOL
HR.MIN.
CLOCK
RESET
CLOCK
MODE
FAN
VANE
START
STOP
ECONO COOL button
ECONO COOL
I FEEL
COOL DRYHEAT
600
1
100
AM
PM
SWING
SWING button
GREEN SIGN
21 22 23 24 25 26 27 28 29 30
Blinking lamp shows
the room temperature
Lighting lamp shows
the set temperature
GREEN SIGN
21 22 23 24 25 26 27 28 29 30
Blinking lamp shows
the room temperature
Lighting lamp shows
the set temperature
MSZ-FX12RV-
E1
Once the controls are set, the same operation mode can be repeated by simply turning the OPERATE/STOP button ON.
Indoor unit receives the signal with a beep tone.
When the system turns off, 3-minute time delay will operate to protect system from overload and compressor will not restart for
3 minutes.
WIRELESS REMOTE CONTROLLER
INDOOR UNIT DISPLAY SECTION
GREEN SIGN
GREEN SIGN shows the current room temperature and set temperature.
The room temperature indicated on the temperature monitor lamp may not be exactly the same as the actual room
temperature.
Available the set temperature range is 16:~31:, however, indication range of temperature monitor lamp is 21:~30:.
The set temperature (lighting) and room temperature (blinking) are displayed.
1.
When the room temperature or set temperature is out of the indication range
If the set temperature is lower than 21:, indicating lamp at 21: is lighting. And if the room temperature is lower
than 21:, indicating lamp at 21: is blinking.
If the set temperature is higher than 30:, indicating lamp at 30: is lighting. And if the room temperature is higher
than 30:, indicating lamp at 30: is blinking.
(Example) When the set temperature is 28:, indicating lamp at 28:
2.When the room temperature or set temperature is within the indication range
(Example) When the set temperature is 26:, indicating lamp at 26:
w When the set temperature and room temperature are the same, corresponding indicating lamp is lighting.
NOTE:
When the unit is not operating : Both POWER MONITOR lamp and green sign lamps are off.
When ON- Timer is set : POWER MONITOR lamp is on. All green sign lamps are off.
When OFF- Timer is set : The lamp indication is as same as ordinary operation.
is lighting.
When the room temperature is 30: or higher, indicating
lamp at 30: is blinking.
is lighting.
When the room temperature is 27.5: or higher and lower
than 28.5:, indicating lamp at 28: is blinking.
17
Model
COOL mode of
"I FEEL CONTROL"
DRY mode of
"I FEEL CONTROL"
HEAT mode of
"I FEEL CONTROL"
Initial room temperatureInitial set temperature
26:
26: or more
26: or less
23: or less
23: to 25:
24:
Initial room temperatureminus 2:
Initial room temperatureminus 2:
❈1
8-1. “I FEEL CONTROL” () OPERATION
Mode
COOL mode of
"I FEEL CONTROL"
DRY mode of
"I FEEL CONTROL"
HEAT mode of
"I FEEL CONTROL"
Initial room temperature
more than 25:
23: to 25:
less than 23:
1. Press OPERATE/STOP button on the remote controller. OPERATION INDICATOR lamp of the indoor unit will turn on
with a beep tone.
2. Press OPERATION SELECT button to set “I FEEL CONTROL”() Then a beep tone is heard.
3. The operation mode is determined by the initial room temperature at start-up of the operation.
● Once the mode is fixed, the mode will not change by room temperature afterwards.
● Under the ON-TIMER () operation, mode is determined according to the room temperature as the operation
starts.
● When the system is stopped with the OPERATE/STOP button on the remote controller, and restarted within 2 hours in “I
FEEL CONTROL” () mode, the system operates in previous mode automatically regardless of the room temperature.
Example
Previous operation
COOL mode of
“I FEEL CONTROL”
Restart
COOL mode of “I
FEEL CONTROL”
or COOL mode
When the system is restarted after 2 hours, the operation mode is determined by the initial room temperature at start-up
of the operation.
Example
Previous operation
COOL mode of “I
FEEL CONTROL”
or COOL mode
Restart
COOL or DRY or HEAT
mode of “I FEEL CONTROL”
that determined by initial
room temperature start-up of
the operation.
4. The initial set temperature is decided by the initial room temperature.
❈1 After the system restarts by the remote controller, the system operates with the previous set temperature regardless
of the initial set temperature
The set temperature is calculated by the previous set temperature.