12. PARTS LIST······················································44
E1E1
E1E1
E1E1
1
Operation section
Horizontal vane
Air filter
Deodorizing filter
(Gray sponge type)
Vertical vanes
Air inlet
Grille
Remote control
receiving section
Remote controller
Display section
(When the grille is opened)
Operation indicator lamp
Receiving section
Air cleaning filter
(White bellows type)
Emergency operation switch
Front panel
Piping
Air inlet
MU-XV07/09UV: Back only
MU-XV12UV : Back and side
Drain hose
Air outlet
Drain outlet
PART NAMES AND FUNCTIONS
INDOOR UNIT
MS-XV07UV MS-XV09UV -
E1
MS-XV12UV -
E1
E1
OUTDOOR UNIT
MU-XV07UV MU-XV09UV -
E1
MU-XV12UV -
E1
E1
3
1
5
1
2
2
1
1
1
1
1
2
3
4
5
6
7
8
9
Installation plate
Installation plate fixing screw 4 x 25 mm
Remote controller holder
Fixing screw for 3 3.5 x 16 mm (Black)
Battery (AAA) for remote controller
Wireless remote controller
Felt tape (Used for left or left-rear piping)
Deodorizing filter
Air cleaning filter
<Indoor unit>
ACCESSORIES
MS-XV07UV MS-XV09UV -
E1
MS-XV12UV -
E1
REMOTE CONTROLLER
MS-XV07UV MS-XV09UV -
Signal transmitting section
E1
MS-XV12UV -
E1
E1
E1
Operation display section
OPERATE/STOP (ON/OFF) button
ECONO COOL button
POWERFUL COOL button
OPERATION SELECT button
TIMER MODE SELECT button
ON/OFF
I FEEL
COOL
DRYFAN
h
TOO
WARM
ECONO COOL
POWERFUL COOL
SELECT
COOL
VANE
TIMEMODE
RESET
TOO
FAN
4
TEMPERATURE buttons
FAN SPEED CONTROL button
VANE CONTROL button
TIME SET button
RESET button
Remote controller holder
2
Indoor model
Function
Power supply
Capacity
Dehumidification
Air flow
(High/Med.W/LowW)
Power outlet
Running current
Power input
Auxiliary heater
Power factor
Starting current
Fan motor current
Model
Winding
resistance(at20:)
Dimensions WOHOD
Weight
Air direction
Sound level
(High/Med.W/LowW)
Fan speed(High/Med.W/LowW)
Fan speed regulator
Thermistor RT11(at25:)
Thermistor RT12(at25:)
Outdoor model
Air flow
Compressor motor current
Fan motor current
Model
Output
Winding
resistance(at20:)
Model
Winding
resistance(at20:)
Dimensions WOHOD
Weight
Sound level
Fan speed
Fan speed regulator
Refrigerant filling
capacity(R22)
Refrigerating oil (Model)
kW
R/h
K /h
A
A
W
A(kW)
%
A
A
"
mm
kg
dB(A)
rpm
k"
k"
K /h
A
A
W
"
"
mm
kg
dB(A)
rpm
kg
cc
MS-XV07UV -
E1
Cooling
Single phase
220-240V, 50Hz
2.1
0.8
474/390
W
/306
W
10
3.34-3.19
720-750
—
98-98
19
0.17
2.92-2.80
RC4V19-LA
WHT-BLK 413
BLK-RED 334
850O278O191
9
5
36/31
W
/26
W
960/810W/670
W
3
10
10
MU-XV07UV -
E1
1,452-1,572
2.96-2.80
0.21-0.22
RH-130VGCT
650
C-R 4.18
C-S 5.76
RA6V23-FA
WHT-BLK 353
BLK-RED 321
780o540o255
30
49
710-760
1
0.51
300 (MS56)
MS-XV09UV -
E1
Cooling
Single phase
220-240V, 50Hz
2.5
1.1
504/408
W
/306
W
10
4.68-4.51
1,010-1,040
—
98-96
25
0.17
2.48-2.40
RC4V19-LA
WHT-BLK 413
BLK-RED 334
850O278O191
9
5
39/34
W
/28
W
1,010/840W/670
W
3
10
10
MU-XV09UV -
E1
1,572-1,680
4.30-4.12
0.21-0.22
RH-165VGCT
800
C-R 3.33
C-S 6.01
RA6V23-FA
WHT-BLK 353
BLK-RED 321
780o540o255
30
49
760-810
1
0.55
300 (MS56)
MS-XV12UV -
E1
Cooling
Single phase
220-240V, 50Hz
3.5
1.6
564/474
W
/384
W
10
7.01-7.07
1,480-1,560
—
96-92
35
0.19
2.36-2.24
RC4V19-KA
WHT-BLK 316
BLK-RED 299
850O278O191
9
5
42/37
W
/32
W
1,110/950W/800
W
3
10
10
MU-XV12UV -
E1
1,848-1,980
6.53-6.56
0.29-0.32
RH-231VHAT
1,100
C-R 2.13
C-S 3.91
RA6V33-DA
WHT-BLK 301
BLK-RED 332
780o540o255
33
49
810-840
1
0.72
520 (MS56)
Electrical
data
Fan
motor
Special
remarks
Compressor
Electrical
data
Fan
motor
Special
remarks
Capacity
Coefficient of performance(C.O.P)
Capacity
SPECIFICATION
NOTE: Test conditions are based on ISO5151.
Cooling : Indoor DB27°C / WB19°C
Outdoor DB35°C / WB24°C
Indoor-Outdoor piping length 5m
W Reference value
5
3
NOISE CRITERIA CURVES
MS-XV07UV -
E1
NOTCH
High
SPL(dB(A))LINE
36
Test conditions,
Cooling : Dry-bulb temperature 27: Wet-bulb temperature 19:
90
80
70
60
50
40
30
MS-XV09UV -
Test conditions,
Cooling : Dry-bulb temperature 27: Wet-bulb temperature 19:
NC-70
NC-60
NC-50
NC-40
NC-30
E1
NOTCH
High
SPL(dB(A))LINE
39
90
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
APPROXIMATE
20
THRESHOLD OF
HEARING FOR
CONTINUOUS
OCTAVE BAND SOUND PRESSURE LEVEL, dB re 0.0002 MICRO BAR
NOISE
10
631252505001000 2000 4000 8000
BAND CENTER FREQUENCIES, Hz
MS-XV12UV -
E1
NOTCH
High
SPL(dB(A))LINE
42
Test conditions,
Cooling : Dry-bulb temperature 27: Wet-bulb temperature 19:
90
80
70
60
50
NC-20
OCTAVE BAND SOUND PRESSURE LEVEL, dB re 0.0002 MICRO BAR
MU-XV07UV MU-XV09UV MU-XV12UV -
NC-70
NC-60
NC-50
APPROXIMATE
20
THRESHOLD OF
HEARING FOR
CONTINUOUS
NOISE
10
631252505001000 2000 4000 8000
NC-20
BAND CENTER FREQUENCIES, Hz
E1
E1
E1
NOTCH
High
SPL(dB(A))LINE
49
Test conditions,
Cooling : Dry-bulb temperature 35: Wet-bulb temperature 24:
90
80
70
NC-70
60
NC-60
50
NC-50
40
30
APPROXIMATE
20
THRESHOLD OF
HEARING FOR
CONTINUOUS
OCTAVE BAND SOUND PRESSURE LEVEL, dB re 0.0002 MICRO BAR
NOISE
10
631252505001000 2000 4000 8000
BAND CENTER FREQUENCIES, Hz
NC-40
NC-30
NC-20
40
30
APPROXIMATE
20
THRESHOLD OF
HEARING FOR
CONTINUOUS
OCTAVE BAND SOUND PRESSURE LEVEL, dB re 0.0002 MICRO BAR
NOISE
10
631252505001000 2000 4000 8000
BAND CENTER FREQUENCIES, Hz
6
NC-40
NC-30
NC-20
4
OUTLINES AND DIMENSIONS
MS-XV07UV MS-XV09UV -
INDOOR UNIT
278
57
140
E1
E1
Installation plate
Indoor unit
818
850
16562956
17.5
Power supply cord
Lead to right 1.0m
Lead to left 0.3m
82169
41
326326
5
189
Air in
7 or more
100
Air out
67
78
2.5
116.581.5
Wall hole [65
Installation plate
Liquid line [6.35-0.5m
Gas line [9.52-0.43m
{
Insulation [37 O.D
[21 I.D
Drain hose [16
(Connected part O.D)
Insulation [28
Unit: mm
231.5
42
2714.5
Wireless remote controller
MS-XV12UV -
INDOOR UNIT
278
E1
57
140
818
850
Installation plate
17.5
Indoor unit
16562956
Power supply cord
Lead to right 1.0m
Lead to left 0.3m
41
Air in
82
326326
189
or more
7
100
Air out
67
78
169
5
Installation plate
Liquid line [6.35-0.5m
Gas line [12-0.43m
{
Insulation [37 O.D
[21 I.D
Drain hose [16
(Connected part O.D)
Insulation [28
231.5
42
2.5
116.581.5
Wall hole [65
2714.5
Wireless remote controller
7
320
25
43-
35-
155
90
104
74
260
10
780
500
122
40
540
320
285
255
Service panel
Gas refrigerant
pipe joint
Refrigerant pipe
(flared) [9.52 (MU-XV07/09UV
The standard data contained in these specifications apply only to the operation of the air conditioner under normal conditions,
since operating conditions vary according to the areas where these units are installed. The following information has been provided to clarify the operating characteristics of the air conditioner under the conditions indicated by the performance curve.
(1) GUARANTEED VOLTAGE
198 ~ 264V, 50Hz
(2) AIR FLOW
Air flow should be set at MAX.
(3) MAIN READINGS
(1) Indoor intake air wet-bulb temperature :°CWB
(2) Indoor outlet air wet-bulb temperature :°CWB
(3) Outdoor intake air dry-bulb temperature :°CDB
(4) Total input:W
Indoor air wet/dry-bulb temperature difference on the left side of the chart on this page shows the difference between the
indoor intake air wet/dry-bulb temperature and the indoor outlet air wet/dry-bulb temperature for your reference at service.
How to measure the indoor air wet-bulb/dry-bulb temperature difference
1. Attach at least 2 sets of wet and dry-bulb thermometers to the indoor air intake as shown in the figure, and at least 2 sets
of wet and dry-bulb thermometers to the indoor air outlet. The thermometers must be attached to the position where air
speed is high.
2. Attach at least 2 sets of wet and dry-bulb thermometers to the outdoor air intake.
Cover the thermometers to prevent direct rays of the sun.
3. Check that the air filter is cleaned.
4. Open windows and doors of the room.
5. Press the EMERGENCY OPERATION switch once to start the EMERGENCY COOL MODE.
6. When system stabilizes after more than 15 minutes, measure temperature and take an average temperature.
7. 10 minutes later, measure temperature again and check that the temperature does not change.
8.4
7.7
7.1
6.4
5.7
5.1
INDOOR UNIT
Wet and dry-bulb
thermometers
9.7
12.8
8.8
11.6
8.0
10.5
7.3
9.5
6.5
8.5
5.8
7.5
OUTDOOR UNIT
Wet and dry-bulb
thermometers
MS-XV07UV - E1
MS-XV09UV - E1
MS-XV12UV - E1
12
OUTDOOR LOW PRESSURE AND OUTDOOR UNIT CURRENT
220V
240V
18
15
20
50
2560 30 32
70(%)
35(:)
3.0
3.5
4.0
4.5
5.0
18
1520
50
25
60
30 32
70(%)
35(:)
0.3
0.4
0.5
0.6
0.7
220-240V
7
6
5
4
3
7
6
5
4
3
1832
1520
50
25
60
30
70(%)
35(:)
0.3
0.4
0.5
0.6
0.7
220-240V
1520
50
25
603070(%)
35(:)
1.5
2.0
2.5
3.0
3.5
32
18
220V
240V
1520
50
25
60
30
70(%)
35(:)
3
4
5
6
7
1832
240V
220V
1520
50
25
603070(%)
35(:)
0.3
0.4
0.5
0.6
0.7
1832
220-240V
7
6
5
4
3
COOL operation
1 Both indoor and outdoor unit are under the same temperature/humidity condition.
Dry-bulb temperature
20
25
3070
2 Air flow should be set at MAX.
3 The unit of pressure has been changed to MPa on the international system of units(SI unit system).
The conversion factor is : 1(MPa [Gage]) =10.2(kgf/ff[Gage])