Mitsubishi Electric Got1000 GT1455-QTBDE, Got1000 GT1455-QTBD, Got1000 GT1450-QLBD, Got1000 GT1450-QMBDE, Got1000 GT1450-QLBDE General Description Manual

...
JY997D43901H
GT1455-QTBD(E), GT1450-QMBD(E)
GT1450-QLBD(E)
GT14 General Description
Manual Number JY997D43901H
Date April 2018
This manual describes the part names, dimensions, mounting, and specifications of the product. Before use, read this manual and manuals of relevant products fully to acquire proficiency in handling and operating the product. Make sure to learn all the product information, safety information, and precautions. And, store this manual in a safe place so that you can take it out and read it whenever necessary. Always forward it to the end user. Registration Ethernet is a trademark of Xerox Corporation in the United States. The company name and the product name to be described in this manual are the registered trademarks or trademarks of each company.
Effective April 2018 Specifications are subject to change without notice.

Safety Precaution

Before using this product, please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly. The precautions given in this manual are concerned with this product. In this manual, the safety precautions are ranked as "WARNING" and "CAUTION".
Depending on circumstances, procedures indicated by "CAUTION" may also be linked to serious results. In any case, it is important to follow the directions for usage.
DESIGN PRECAUTIONS
Some failures of the GOT or cable may keep the outputs on or off.
An external monitoring circuit should be provided to check for ou tput signals which may lead to a serious accident. Not doing so can cause an accident due to false output or malfunction.
If a communication fault (including cable disconnection) occurs during
monitoring on the GOT, communication between the GOT and PLC CPU is suspended and the GOT becomes inoperative. A system where the GOT is used should be configured to perform any significant operation to the system by usi ng the switches of a device other than the GOT on the assumption that a GOT communication fault will occur. Not doing so can cause an accident due to false output or malfunction.
Do not use the GOT as the warning device that may cause a serious
accident. An independent and redundant hardware or mechanical interlock is required to configure the device that displays and outputs serious warning. Failure to observe this instruction may result in an accident due to incorrect output or malfunction.
Incorrect operation of the touch switch(s) may lead to a serious accident if the GOT backlight is gone out. When the GOT backlight goes out, the POWER LED flickers (green/orange) and the display section turns black and causes the monitor screen to appear blank, while the input of the touch switch(s) remains active. Thi s may confuse an operat or in thinking that the GOT is in "screensaver" mode, who then tries to release the GOT from this mode by touching the display section, which may cause a touch switch to operate. Note that the following occurs on the GOT when the backlight goes out.
- The PO WER LED flickers (green/orange) and the monitor screen appears blank
The display section is an analog-resistive type touch panel.
If you touch the display section simultaneously in 2 points or more, the switch that is located around the center of the touched point, if any, may operate. Do not touch the display section in 2 points or more simultaneously. Doing so may cause an accident due to incorrect output or malfunction.
When programs or parameters of the controller (such as a PLC) that is
monitored by the GOT are changed, be sure to reset the GOT or shut off the power of the GOT at the same time. Not doing so can cause an accident due to false output or malfunction.
2011 MITSUBISHI ELECTRIC CORPORATION
(Read these precautions before using.)
Indicates that incorrect handling may cause hazardous conditions, resulting in death or severe injury.
Indicates that incorrect handling may cause hazardous conditions, resulting in medium or slight personal injury or physical damage.
DESIGN PRECAUTIONS
When the security of the GOT and relevant information need to be protected
against illegal access from an external de vice via the Internet, take measures at the user's discretion. Failure to do so may cause the configured information to be read out illegally.
DESIGN PRECAUTIONS
Do not bundle the control and communication cables with main-circuit, power or
other wiring. Run the above cables separately from suc h wiring and keep them a minimum of 100mm (3.94in.) apart.Not doing so noise can cause a malfunction.
Do not press the GOT display section with a pointed material as a pen or driver.
Doing so can result in a damage or failure of the display section.
When using the GOT with Ethernet connection, available IP addresses are
restricted depending on the system configuration.
- W hen connecting two or more GOT units to the Ethernet network: Do not specify the IP address "192.168.0.18" to the GOT or any connected equipment.
- W hen connecting one GOT unit to the Ethernet network: Do not specify the IP address "192.168.0.18" to any connected equipment other than the GOT. If the IP address "192.168.0.18" is specified in the above system configuration, IP address overlap occurs when the GOT is started up, and adverse effect may be given to communication in the equipment in which the IP address "192.168.0.18" is set. Operation executed at IP address overlap varies depending on the equipment and system.
Turn on the power of the connected equipment and network equipment, and
make them ready for communication before connecting them to the GOT. If the connected equipment and network equipment are not ready for communication, a communication error may occur in the GOT.
MOUNTING PRECAUTIONS
Be sure to shut off all phases of the external power supply used by the system
before mounting or removing the GOT to/from the panel. Not doing so can cause the unit to fail or malfunction.
MOUNTING PRECAUTIONS
Use the GOT in the environment that satisfies the general specifications
described in this manual. Not doing so can cause an electric shock, fire, malfunction or product damage or deterioration.
When mounting the GOT to the control panel, tighten the mounting screws in the
specified torque range. Undertightening can cause the GOT to drop, short circuit or malfunction, and deteriorate the waterproof effect and oilproof effect. Overtightening can cause a drop, sho rt circuit or malfunction due to the damage of the screws or the GOT, and deteriorate the waterproof effect and oilproof effect due to distortion of the protective cover for oil, GOT or panel.
Never drop cutting chips and electric wire chips into the ventilation window of the
GOT when you drill screw holes or perform wiring. Otherwise, fire, failure or malfunction may be caused.
When inserting/removing a SD card into/from the GOT, turn the SD card access
switch off in advance. Failure to do so may corrupt data within the SD card.
When removing a SD card from the GOT, make sure to support the SD card by
hand, as it may pop out. Failure to do so may cause the SD card to drop from the GOT and break.
When installing a USB memory to the GOT, make sure to install the USB memory
to the USB interface firmly. Failure to do so may cause a malfunction due to poor contact.
Before removing the USB memory from the GOT, operate the utility screen for
removal. After the successful completion dialog box is displayed, remov e the memory by hand carefully. Failure to do so may cause the USB memory to drop, resulting in a damage or failure of the memory.
Operate and store the GOT in environments without direct sunlight, high
temperature, dust, humidity, and vibrations.
When using the GOT in the environment of oil or chemicals, use the protective
cover for oil. Failure to do so may cause failure or malfunction due to the oil or chemical entering into the GOT.
WIRING PRECAUTIONS
Be sure to shut off all phases of the external power supply used by the system
before wiring. Failure to do so may result in an electric shock, product damage or malfunctions.
Please make sure to ground FG terminal of the GOT power supply section by
applying 100 or less which is used exclusively for the GOT. Not doing so may cause an electric shock or malfunction.
WIRING PRECAUTIONS
Correctly wire the GOT power supply section after confirming the rated voltage
and terminal arrangement of the product. Not doing so can cause a fire or failure.
Tighten the terminal screws of the GOT power supply section in the specified
torque range. Undertightening can cause a short circuit or malfunction. Overtightening can cause a short circuit or malfunction due to the damage of the screws or the GOT.
Exercise care to avoid foreign matter such as chips and wire offcuts entering the
GOT. Not doing so can cause a fire, failure or malfunction.
WIRING PRECAUTIONS
The cables connected to the unit must be run in ducts or clamped.
Not doing so can cause the unit or cable to be damaged due to the dangling, motion or accidental pulling of the cables or can cause a malfunction due to a cable connection fault.
When unplugging the cable connected to the unit, do not hold and pull the cable
portion. Doing so can cause the unit or cable to be damaged or can cause a malfunction due to a cable connection fault.
Plug the communication cable into the connector of the connected unit and
tighten the mounting and terminal screws in the specified torque range. Undertightening can cause a sho rt circuit or malfunction. Overtighte ning can cause a short circuit or malfunction due to the damage of the screws or unit.
TEST OPERATION PRECAUTIONS
Before performing the test operations of the user creation monitor screen (such
as turning ON or OFF bit device, changing the word device current value, changing the settings or current values of the timer or counter, and changing the buffer memory current value), read through the manual care fully and make yourself familiar with the operation method. During test operation, neve r change the data of the devices whic h are used to perform significant operation for the system. False outpu t or malfunction can cause an accident.
STARTUP/MAINTENANCE PRECAUTIONS
When power is on, do not touch the terminals.
Doing so can cause an electric shock or malfunction.
Connect the battery correctly. Do not discharge, disassemble, heat, short, solder
or throw the battery into the fire. Incorrect handling may cause the battery to generate heat, burst or take fire, resulting in injuries or fires.
Before starting cleaning or terminal screw retightening, always switch off the
power externally in all phases. Not switching the power off in all phases can cause a unit failure or malfunction. Undertightening can cause a short circuit or malfunction. Overtightening can cause a short circuit or malfunction due to the damage of the screws or unit.
STARTUP/MAINTENANCE PRECAUTIONS
Do not disassemble or modify the unit.
Doing so can cause a failure, malfunction, injury or fire.
Do not touch the conductive and electronic parts of the unit directly.
Doing so can cause a unit malfunction or failure.
The cables connected to the unit must be run in ducts or clamped.
Not doing so can cause the unit or cable to be damaged due to the dangling, motion or accidental pulling of the cables or can cause a malfunction due to a cable connection fault.
When unplugging the cable connected to the unit, do not hold and pull the cable
portion. Doing so can cause the unit or cable to be damaged or can cause a malfunction due to a cable connection fault.
Do not drop or apply any impact to the battery.If any impact has been applied,
discard the battery and never use it. The battery may be damaged by the drop or impact.
Before touching the unit, always touch grounded metal, etc. to discharge static
electricity from human body, etc. Not doing so can cause the unit to fail or malfunction.
Replace battery with GT11-50BAT by Mitsubishi electric Co. only.
Use of another battery may present a risk of fire or explosion.
Dispose of used battery promptly.
Keep away from children. Do not disassemble and do not dispose of in fire.
DISPOSAL PRECAUTIONS
When disposing of the product, handle it as industrial waste.When disposing of batteries, separate them from other wastes according to the
local regulations. (For details of the battery directive in EU member states, refer GOT User's Manual.)
TOUCH PANEL PRECAUTIONS
For the analog-resistive film type touch panels, normally the adjustment is
not required. However, the difference between a touched position and the objec t position may occur as the period of use elapses. When any difference between a touched position and the object position occurs, execute the touch panel calibration.
When any difference between a touched position and the object position
occurs, other object may be activated. This may cause an unexpected operation due to in correct output or malfunction.
TRANSPORTATION PRECAUTIONS
When transporting lithium batteries, make sure to treat them based on the
transport regulations. (Refer to User's Manual for details of the regurated models.)
Before transporting the GOT, turn the GOT power on and check that the
battery voltage status is normal on the Time setting & display screen (utilities screen). In addition, confi rm that the adequate battery life remains on the rating plate. Transporting the GOT with the low battery voltage or the battery the reached battery life may unstabilize the backup data unstable during transportation.
Make sure to transport the GOT main unit and/or relevant unit(s) in the
manner they will not be exposed to the impact exceeding the impact resistance described in the general specifications of this manual, as th ey are precision devices. Failure to do so may cause the unit to fail. Check if the unit operates correctly after transportation.

Associated Manuals

The following manuals are relevant to this product. When these loose manuals are required, please consult with our local distributor.
Manual name Contents
Describes the GT14 hardware-
GT14 User’s Manual (sold separately)
GT Designer3 Version1 Screen Design Manual (For GOT1000 Series) (Fundamentals) 1/2, 2/2 (sold separately)
GT Designer3 Version1 Screen Design Manual (For GOT1000 Series) (Functions) 1/2, 2/2 (sold separately)
*1 Stored in the GT Works3/GT Designer3 in PDF format.
For details of a PLC to be connected, refer to the PLC user's manual respectively.
relevant content such as part names, external dimensions, mounting, power supply wiring, specificatio ns, and introduction to option devices
Describes methods of the GT Designer3 installation operation, basic operation for drawing and transmitti ng data to GOT1000 series
*1
Describes specifications and se ttings of the object functions used in GT Designer3
*1
Manual Number
(Model Code)
JY997D44801
(09R823)
SH-080866ENG
(1D7MB9)
SH-080867ENG
(1D7MC1)

Bundled Items

Product
Model Name Specifications
Name
GOT
GT1455-QTBDE
GT1455-QTBD
GT1450-QMBDE
GT1450-QMBD
GT1450-QLBDE
GT1450-QLBD
5.7" diagonal [320 240 dots], TFT color (65536 colors), built-in battery and Ethernet interface
5.7" diagonal [320 240 dots], TFT color (65536 colors), built-in battery
5.7" diagonal [320 240 dots], TFT mon ochrome (black/white), built-in battery and Ethernet interface
5.7" diagonal [320 240 dots], TFT mon ochrome (black/white), built-in battery
5.7" diagonal [320 240 dots], STN monochrome (black/white), built-in battery and Ethernet interface
5.7" diagonal [320 240 dots], STN monochrome (black/white), built-in battery
Bundled item Quantity
Mounting brackets 4
Mounting screws: M4 x 35mm (1.38") 4
Dust-/Water-proof packing 1
GT14 General Description (This manual) 1

1. Features

1) Improved monitoring performance and connectivity to FA devices
- Multiple languages are displayed using the Unicode2.1-compatible fonts and beautiful characters are drawn using the TrueType and high quality fonts.
- Two types of display modes are provided: 65536-colors display and monochrome display. In the monochrome display, 16 scales are used to improve the display. A fine and beautiful full-color display which shows even small characters clearly, is enabled by adopting the high intensity, wide viewing angle and high definition TFT color LCD. (Also compatible with digital screen displays with 65536 colors, BMP, etc.)
- High-speed monitoring t hrough high-speed serial communication at 115.2 kbps maximum or through Ethernet connection.
- High speed dis play and high speed touch switch response.
2) More efficient GOT operations incl uding screen design, startup, adjustment, management and maintenance works
- The 9MB built-in flas h memory is included as standard.
- SD card interface is inc luded as standard.
- RS-232 interface is incl uded as standard.
- RS-422/485 interface is inc luded as standard.
- USB interface (host/de vice) are included as standard.
- Ethernet interface is included. (in some models)
3) Enhanced support of FA setup tools
- PLC program transfer and monitoring are poss ible via the personal computer that is connected to the GOT if connected directly to the A, QnA, L, Q, or FX series of the PLC CPU (FA transparent function).

2. Part Name

2.1 Front

1) 2)
3)
No Name Specifications
1) Display screen
2) Touch panel
3) POWER LED
4) Logo label Removable
5) USB interface
USB environmental
6) protection cover
For the PC connection, refer to the following.
4)
5) 6)
Displays the utility screen and the user creation screen. GT1455-QTBD(E):320240 dots, TFT color liquid
GT1450-QMBD(E):320240 dots, TFT monochrome
GT1450-QLBD(E):320240 dots, STN monochrome
For operating the touch switches in the utility screen and the user creation screen
Lit in green: Power is correctly supplied Lit in orange: Screen saving Blinking in orange/green: Blown backlight bulb Not lit: Power is not supplied
USB interface for connecting a personal computer (Device) OS installation, project data download, FA transparent
crystal
(white/black) liquid crystal, 16 scales
(white/black) liquid crystal, 16 scales
Opens/Closes when the USB interface is used.
GT14 User’s Manual

2.2 Back/Bottom

1)
2)
17) 17)16)
8)
7)5)4) Battery cover opened
6)
14)
13)
15)10)3)11) 12)
9)
No. Name Specifications
1)
2)
RS-232 interface
RS-422/485 interface
For communicating with controller or personal computer (D-sub 9-pin male)
For communicating with controller (D-sub 9-pin female)
3) USB interface For data transfer, data storage USB interface (Host)
Hole for preventing
4)
USB cable disconnection
Rating plate
5) (nameplate)
SD card
6) interface
SD card
7) access LED
SD card
8) access switch
9) Battery
10) Battery cover
11) Power terminal
Power terminal
12) cover
Hole for fixing the USB cable with a cable tie (such as Insulock) to prevent disconnection
--
Interface for installing the SD card to GOT
Lit: SD card accessed Not lit: SD card not accessed
Switch for prohibiting access to SD card before removing the SD card from the GOT ON: SD card being accessed (SD card removal prohibited) OFF: No access to SD card (SD card removal possible)
GT11-50BAT battery for storing clock data, alarm history and recipe data
Open or close when replacing the battery. Opened and closed when the terminating resistor is changed over
Power terminal and FG terminal (for power supply (24VDC) to GOT and grounding)
Open or close when connecting a power terminal. (Color: transparent)
13) Reset switc h Hardware reset switch (Use an isolated rod to operate.)
Terminating
14)
resistor selector switch
Ethernet
15)
communication status LED
Ethernet
16) interface
Hole for unit
17)
installation fitting
For the connection to the controller (PLC, microcomputer board, bar code reader, RFID, etc) or PC, refer to the following.
Terminating resistor selector switch of RS-422/485 (330/OPEN/110)
SD RD: Turns on in green during data communication, 100M:Turns on in green during 100Mbps transmission.
For connecting the equipment through Ethernet (RJ-45 connector)
Hole for the inserting installation fittings (accessory) during the GOT installation to the panel (4 holes at top and bottom)
GT14 User’s Manual

3. Specifications

3.1 General Specifications

Item Specifications
Operating ambient temperature
Storage ambient temperature -20 to 60C
Operating ambient humidity 10 to 90% RH, non-condensing (STN liquid crystal type to be stored at or below 39C WBT.)
Storage ambient humidity 10 to 90% RH, non-condensing (STN liquid crystal type to be stored at or below 39C WBT.)
Vibration resistance
Shock resistance
Operating atmosphere
Operating altitude
Installation location Inside control panel
Overvoltage category
Pollution degree
Cooling method Self-cooling
*1 Do not use or store the GOT under pressure higher than the atmospheric pressure of altitude 0m (0ft.). Failure to obse rve this instruction may cause a malfunction.
When the air inside the control panel is purged by pressurization, the surface sheet may be lifted by high pressure. As a result, the touch panel may be difficult to press, and the sheet may be peeled off.
*2 This indicates the section of the power supply to which the equipment is assumed to be connected between the public electrical power distrib ution network and the
machinery within the premises. Category  applies to equipment for which electrical power is supplied from fixed facilities. The surge voltage withstand level for up to the raged voltage of 300 V is 2500 V.
*3 This index indicates the degree to which conductive material is ge nerated in the environment where the equipment is used.
In pollution degree 2, only non-conductive pollution occurs but temporary conductivity may be produced due to condensation.

3.2 Performance Specifications

Display
*1
section
Backlight
Touch
*4
panel
Memory
Battery GT11-50BAT lithium battery
Display section 0 to 50C
Other than display section 0 to 55C (When mounted horizontally), 0 to 50C (When mounted vertically)
Frequency Acceleration Half-amplitude Sweep Count
Conforms to JIS B3502 and IEC61131-2
Under intermittent vibration
Under continuous vibration
5 to 8.4Hz -- 3.5mm
8.4 to 150Hz 9.8m/s
2
5 to 8.4Hz -- 1.75mm
8.4 to 150Hz 4.9m/s
2
--
--
10 times each in X,
Y and Z directions
Conforms to JIS B3502, IEC 61131-2 (147 m/s2, 3 times each in X, Y and Z directions)
Must be free of lamp black, corrosive gas, flammable gas, or excessive amount of electro conductive dust particles and
*1
*2
*3
Item
Type TFT color liquid crystal
must be no direct sunlight. (Same as for saving)
2000 m (6562 ft) max.
 or less
2 or less
Specifications
GT1455-QTBD(E) GT1450-QMBD(E) GT1450-QLBD(E)
TFT monochrome (white/black) liquid crystal
STN monochrome (white/black) liquid crystal
Screen size 5.7"
Resolution 320 240 dots
Display size W 115(4.53) H86(3.39)[mm](inch) (Horizontal format)
Display character 16-dot standard font: 20 characters 15 lines, 12-dot standard font: 26 characters  20 lines
Display color 65536 colors Monochrome (white/black), 16 scales
Display angle
*2
Contrast adjustment
Intensity of LCD only
Left/Right: 80 degrees, Top: 80 degrees, Bottom: 60 degrees (Horizontal format)
2
] 300[cd/m2]
400[cd/m
--
Left/Right: 45 degrees, Top: 20 degrees, Bottom: 40 degrees (Horizontal format)
32-level adjustmen
Intensity adjustment 8-level adjustment
Life Approx. 50,000h. (Time for display intensity to become 1/5 at operating ambient temperature of 25C)
LED (irreplaceable by a user) Backlight off/screen saving time can be set.
*3
Life Approx. 70,000h or longer (Time for display intensity reaches 50% at the operating ambient temperature of 25C)
Type Analog resistive film touch panel
Key size Minimum 2 2 dots (per key)
Number of points touched simultaneously
Simultaneous presses not allowed. (Only 1 point can be touched.)
Life 1 million times or more (operating force 0.98N max.)
C drive
*5
Flash memory (Internal), for storing project data (9Mbytes) and OS
Life (Number of write times) 100,000 times
D drive SRAM (Internal), 512k bytes (battery backup)
Type Magnesium maganese dioxide lithium primary battery
Backup target
Clock data, alarm history, recipe data, time action setting value, advanced alarm/advanced recipe, logging, hardcopy and SRAM user area
Life Approx. 5 years (Operating ambient temperature of 25C)