30022 VRJ
60 LB. (27KG) CAPACITY
RIGID-MOUNT WASHER-EXTRACTOR
FLOOR REQUIREMENT 12” MINIMUM
RECOMMENDED ▼,
SPECIFICATION SHEET
|
LEGEND |
|
C |
Cold water inlet, .75” (19 mm) GHT |
|
|
|
|
D |
Drain to rear, 3” (76 mm) pipe socket |
|
joint |
||
|
||
E |
Main electrical connection |
|
|
|
|
F |
Anchor bolt holes, .8125” |
|
(20 mm) diameter |
||
|
||
|
|
|
L1 |
Standard soap chute |
|
|
|
|
L2 |
Liquid supply inlets |
|
|
|
|
H1 |
Hot water (chemical flushing), .75” |
|
(19 mm) GHT |
||
|
||
H2 |
Hot water, .75” (19 mm) GHT |
|
|
|
MECHANICAL SPECIFICATIONS ELECTRICAL SPECIFICATIONS
|
Capacity – lbs (kg) |
|
|
60 (27) |
|
|
|
Voltage |
Running |
Fuse |
Circuit Breaker |
|
|
Cylinder Diameter x Depth – ins (mm) |
|
30 x 22 (762 x 559) |
|
|
|
Amps |
(Amps) |
(Amps) |
|
||
|
Door Opening – ins (mm) |
|
|
15.5 (394) |
|
|
|
220/3/50-60 |
7 |
FRN20 |
20 |
|
|
Cylinder Volume – cu. ft. (L) |
9 (255) |
|
|
|
208,240/1/60 |
9, 8 |
FRN20 |
20 |
|
||
|
|
|
|
|
|
|
|
208, 240/3/60 |
8, 7 |
FRN20 |
20 |
|
|
Machine Dimensions |
|
34.5 x 56.31 x 57.69 |
|
||||||||
|
(W x D x H) – ins (mm) |
|
(876 x 1431 x 1466) |
|
380/3/50-60 |
4.5 |
FRS15 |
15 |
|
|||
|
Shipping Dimensions |
|
40 x 64 x 60 |
|
|
415/3/50 |
4.5 |
FRS15 |
15 |
|
||
|
(W x D x H) – ins (mm) |
|
(1016x1625x1524) |
|
|
480/3/60 |
3.5 |
FRS15 |
15 |
|
||
|
Motor – HP (kW) |
|
|
5 (3.72) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
See Fuse and Wire Size manual MAEFUSE1BE for safety information. |
|
|||||
|
Wash Speeds – RPM |
|
|
38-43 |
|
|
▼See dimensional drawing for complete details. |
|
|
|||
|
Distribution Speed – RPM |
|
|
65 |
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
||
|
Extraction Speeds – RPM |
420-685 |
|
|
|
It is the sole responsibility of the owner/user to assure that the floor and/or any |
|
|||||
|
|
|
|
|
|
|
other supporting structure exceeds not only all applicable building codes, but also |
|
||||
|
Extraction G-Force |
|
|
200 |
|
|
||||||
|
|
|
|
|
|
that the floor and/or any other supporting structure for each washer-extractor or |
|
|||||
|
|
|
|
|
|
|
|
|
||||
|
Static Weight – lbs (kg) |
1344 (610) |
|
|
|
group of washer-extractors has sufficient strength and rigidity (i.e., a natural or |
|
|||||
|
|
|
|
|
|
|
|
resonant frequency many times greater than the rotational machine speed with a |
|
|||
|
Max. Dynamic Load RMS - lbs (kg) |
|
|
1800 (816) |
|
|
||||||
|
|
|
|
|
|
reasonable factory of safety) to support the weight of all the fully loaded machine(s) |
|
|||||
|
|
|
|
|
|
|
|
including the weight of the water and goods, and including the published 360º |
|
|||
|
Frequency (Hz) |
12.5 |
|
|
||||||||
|
|
|
|
rotating sinusoidal RMS forces that are transmitted by the machine(s). Contact the |
|
|||||||
|
Water Pressure (Required) – psi (bar) |
|
|
10-75 (.68-5.1) |
|
|
|
factory for additional machine data for use by a structural engineer. |
|
|||
|
|
|
|
|
|
|
|
|
|
|
||
|
Water Valve Cv Rating – gal/min (L/min) |
|
|
5.8 (22) |
|
|
|
|
|
|
|
|
|
Minimum Recommended Distance |
|
6 (152) |
|
|
|
|
|
|
|
|
|
|
Between Machines – ins (mm) |
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
||
|
B22SS13001/13094 Page 1 of 2 |
|
|
|
|
|
|
|
|
|
|