Milnor 30022 T5X Manual

4.3 (3)
Milnor 30022 T5X Manual

30022 T5X

60 LB. (27KG) CAPACITY

RIGID-MOUNT WASHER-EXTRACTOR

SPECIFICATION SHEET

 

LEGEND

C

Cold water inlet, .75” (19 mm) GHT

D

Drain to sewer, 3” (76 mm) pipe

connection

 

E

Electrical connection

 

 

F

Anchor bolt holes, .813” (21 mm)

diameter

 

H

Hot water inlet, .75” (19 mm) GHT

 

 

L1

Soap chute

 

 

L2

Liquid supply inlets

 

 

FLOOR REQUIREMENT 12” MINIMUM

RECOMMENDED ▼,

 

MECHANICAL SPECIFICATIONS

 

 

ELECTRICAL SPECIFICATIONS

 

Capacity – lbs (kg)

 

 

60 (27)

 

 

 

Voltage

Running

Fuse

Circuit Breaker

 

 

Cylinder Diameter x Depth – ins (mm)

 

 

30 x 22 (762 x 559)

 

 

 

 

Amps

(Amps)

(Amps)

 

 

Cylinder Volume – cu. ft. (L)

 

 

9 (255)

 

 

220/3/50

7

FRN15

15

 

 

Door Opening – ins (mm)

 

 

15.5 (394)

 

 

208,240/1/60

9/8

FRN20

20

 

 

 

 

 

 

 

 

 

208,240/3/60

8/7

FRN15

15

 

 

Machine Dimensions

 

34.5 x 52.25 x 54

 

(W x D x H) – ins (mm)

 

(876 x 1327 x 1372)

 

 

380/3/50-60

4.5

FRS15

15

 

 

Shipping Dimensions

 

 

40 x 60 x 60

 

 

 

415/3/50

4.5

FRS15

15

 

 

(W x D x H) – ins (mm)

 

 

(1016x1524x1524)

 

 

 

480/3/60

3.5

FRS15

15

 

 

Motor – HP (kW)

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

See Fuse and Wire Size manual MAEFUSE1BE for safety information.

 

Wash Speed – RPM

 

 

38

 

 

 

 

 

 

See dimensional drawing for complete details.

 

 

 

Distribution Speed – RPM

 

 

64

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Extraction Speed – RPM

 

 

509

 

 

 

It is the sole responsibility of the owner/user to assure that the floor and/or any

 

 

 

 

 

 

 

other supporting structure exceeds not only all applicable building codes, but also

 

Extraction G-Force

 

 

110

 

 

 

 

 

 

 

that the floor and/or any other supporting structure for each washer-extractor or

 

 

 

 

 

 

 

 

 

Static Weight – lbs (kg)

1329 (603)

 

 

 

group of washer-extractors has sufficient strength and rigidity (i.e., a natural or

 

 

 

 

resonant frequency many times greater than the rotational machine speed with a

 

Max. Dynamic Load RMS – lbs (kg)

1170 (531)

 

 

 

 

 

 

 

reasonable factory of safety) to support the weight of all the fully loaded machine(s)

 

 

 

 

 

 

 

 

including the weight of the water and goods, and including the published 360º

 

Frequency (Hz)

8.48

 

 

 

 

 

rotating sinusoidal RMS forces that are transmitted by the machine(s). Contact the

 

Water Pressure (Required) – psi (bar)

 

 

10-75 (0.69-5.17)

 

 

 

factory for additional machine data for use by a structural engineer.

 

 

 

 

 

 

 

 

 

 

 

 

Water Valve Cv Rating – gal/min (L/min)

 

 

3.6 (14)

 

 

 

 

 

 

 

 

 

Minimum Recommended Distance

 

 

6 (152.4)

 

 

 

 

 

 

 

 

 

Between Machines – ins (mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B22SS1033/10503 Page 1 of 2

Loading...
+ 1 hidden pages