Miele XKM 2000 KM Installation Instructions Manual

Fitting and installation instructions
Miele|home Con|ctivity XKM 2100 KM
M.-Nr. 07 828 230
en-GB
Electrical connection...............................................5
Con|ctivity......................................................10
Miele|home .....................................................13
Installation options .................................................16
a First installation of the InfoControl unit and signing on of the hob ..........17
b First installation of the SuperVision appliance and signing on of the hob ....19
c First installation of the InfoControl unit and SuperVision appliance,
signing on of the hob ...............................................21
f Signing on the hob to the InfoControl unit at a later date .................23
g Signing on the hob to the SuperVision appliance at a later date ...........25
Signing off the hob ...............................................26
Contents
2
This appliance complies with all relevant legal safety requirements. Improper use of the appliance can present a risk of both personal injury and material damage.
To avoid the risk of accidents and damage to the appliance, please read these instructions carefully before installation and before using it for the first time. They contain important notes on its installation, safety, use and maintenance.
Keep these instructions in a safe place and ensure that new users are familiar with the content. Pass them on to any future owner.
~
Before installation, check the appliance for visible signs of damage. Do not install and use a damaged appliance. It could be dangerous.
~
Before connecting the appliance, make sure that the connection data on the data plate (voltage and connected load) match the mains electricity supply. This data must correspond in order to avoid the risk of damage to the appliance. Consult a qualified electrician if in any doubt.
~
The electrical safety of this appliance can only be guaranteed when continuity is complete between it and an effective earthing system which complies with current local and national safety regulations. It is most important that this basic safety requirement is present and regularly tested, and where there is any doubt, the household wiring system should be inspected by a qualified electrician. The manufacturer cannot be held liable for the consequences of an inadequate earthing system (e.g. electric shock).
~
If the appliance is supplied without a plug, or if the plug is removed, it must be connected to the mains electricity supply by a suitably qualified and competent electrician in strict accordance with current local and national safety regulations. The manufacturer cannot be held liable for damage caused by incorrect installation or connection.
~
Never open the casing of the appliance. Tampering with electrical connections or components and mechanical parts is highly dangerous to the user and can cause operational faults.
Warning and safety instructions
3
~
Installation, maintenance and repairs may only be carried out by a Miele authorised person in strict accordance with current national and local safety regulations. Repairs and other work by unqualified persons could be dangerous. The manufacturer cannot be held liable for unauthorised work. Ensure that current is not supplied to the appliance until after maintenance or repair work has been carried out.
~
Faulty components must only be replaced by genuine Miele original spare parts. The manufacturer can only guarantee the safety of the appliance when Miele replacement parts are used.
~
During installation, maintenance and repair work, the XKM 2100 KM and the hob must be disconnected from the mains electricity supply.
~
While the appliance is under guarantee, repairs should only be undertaken by a service technician authorised by the manufacturer. Otherwise the guarantee is invalidated.
~
Do not connect the appliance to the mains electricity supply by an extension lead or a multi-socket unit. These do not guarantee the required safety of the appliance (e.g. danger of overheating).
~
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience or knowledge, unless they are supervised whilst using it, or have been shown how to use it correctly by a person responsible for their safety.
~
This appliance is not a toy! To avoid the risk of injury, keep children well away and do not let them play with it. They should be supervised whenever you are working in the kitchen.
Warning and safety instructions
4
All electrical work should be carried out by a suitably qualified and competent person in strict accordance with current local and national safety regulations (BS 7671 in the UK).
This appliance can be connected to the mains electricity supply either via a plug and switched socket or via a suitable fused spur connection unit. The socket and on-off switch should be easily accessible after the appliance has been built in.
Connection to a fused spur connection unit must be carried out by a suitable qualified electrician only.
If the connection socket is not accessible after installation (depending on country) an additional means of disconnection must be provided for all poles. When switched off there must be an all-pole contact gap of 3 mm in the switch (including switch, fuses and relays).
See data plate for connection details. Ensure that these match the mains supply.
Ensure power is not supplied to the appliance until after installation work has been carried out.
The appliance must only be operated when built-in. This is to ensure that all electrical parts are shielded. Live parts must not be exposed.
Do not connect the appliance to the mains electricity supply via an extension lead. These do not guarantee the required safety of the appliance.
Total connected load
See data plate
Voltage and fuse rating
AC230V/50Hz Fuse rating 10 A Release Type B or C
Residual current device
For extra safety it is advisable to install a suitable residual current device with a trip current of 30 mA.
Electrical connection
5
To change the mains connection cable
If the connection cable is damaged, it must be replaced by cable type H 05 V V-F (pvc insulated), available from the Miele Spare Parts Department.
If the appliance is connected via a fused spur, the electrical cable must only be replaced by a suitable qualified electrician in accordance with local and national safety regulations. Connection data is quoted on the data plate.
Important UK
The wires in the mains lead are coloured in accordance with the following code:
Green/yellow = earth
Blue = neutral
Brown = live
WARNING THIS APPLIANCE MUST BE EARTHED
The earth lead must be connected to the connection marked -.
Electrical connection
6
Miele|home connection box
a Shaft with communication module fitted
b Data line
c Connection point for mains connection cable
1 connection cable with plug
1 connection cable with wire end ferrules
Accessories supplied:
Adapter
Description of the appliance
7
a
b
c
Data line
The connection point for the data line is located underneath the hob. The following illustrations are examples. The connection position may vary.
Type 1
Type 2
Type 3
Connecting the communication module
8
,
Data line types 1 and 2 must only be connected to the appliance by a qualified and competent electrician in strict accordance with current local and national safety regulations (BS 7671 in the UK).
^
Disconnect the hob from the electricity supply.
^
Remove the cover from the data line connection point (see illustration "Connecting the data line", Type 1 and Type 2).
^
Connect the data line. Use the adapter supplied for connection types 1 and 2.
^
Replace the cover and secure with the screws (Type 1 and Type 2 connections).
^ Connect the Miele|home connection box to the mains
supply.
,
The Miele|home connection box must not be screwed to the underside of the hob or to an oven or cooker!
Connecting the communication module
9
How the Con|ctivity system works
Con|ctivity is the communication between the hob and the cooker hood.
The operation of the cooker hood is automatically controlled by the operating status of the hob.
For communication to take place, the cooker hood must be fitted with communication module XKM 2000 DA a and the hob must be fitted with communication module XKM 2100 KM b.
The hob transmits information about its operating status to the cooker hood via the household power supply (Powerline) c.
The XKM 2000 DA a is fitted inside the cooker hood and will get its power supply from the cooker hood.
The XKM 2100 KM b has its own electrical connection to the mains independent from the hob and needs to be connected to the same ring main circuit that the cooker hood is connected to for communication to take place.
Con|ctivity
10
Loading...