Installation plan
Commercial dryer
PDR914/514 G
Gas heated
To avoid the risk of accidents or damage to the
machine, it is essential to read these instructions before it is installed and used for the first
time.
Concrete platform (on site)............................................................................................ 11
2
Installation notes
Installation requirements
The tumble dryer must only be installed and commissioned by Miele Customer Service
Department or an authorised dealer.
The tumble dryer must be installed in accordance with all relevant regulations and
standards.
The dryer must only be operated in a room that has sufficient ventilation and which is
frost-free.
Electrical connection
The electrical connection must be established by a qualified electrician.
The electrical connection may only be made to an electrical system provided in accord-
ance with all appropriate local and national legislation, regulations and guidelines. Please
also observe the regulations set out by your insurance provider and energy supplier, accident prevention regulations, as well as recognised codes of practice.
Reliable and safe operation of this tumble dryer is only ensured if it has been connected
to the mains electricity supply.
The required supply voltage, power rating and fuse rating can be found on the data plate
on the tumble dryer. Ensure that the supply voltage matches the voltage quoted on the
data plate before establishing the electrical connection to the tumble dryer.
Connection to a supply voltage other than the one quoted on the data plate can damage
the tumble dryer if the voltage is too high.
If more than one voltage is specified on the data plate, the tumble dryer can be conver-
ted for connection to the relevant input voltage. This conversion must be performed by the
Miele Customer Service Department or by an authorised dealer. During the conversion, the
wiring instructions given on the wiring diagram must be followed.
The tumble dryer can either be hard-wired or connected using a plug-and-socket connection in accordance with IEC60309-1. For a hard-wired connection, an all-pole isolation
device must be available at the installation site.
An isolation device is a switch which ensures a contact opening of more than 3mm.
These include circuit breakers, fuses and contactors (IEC/EN60947).
If the mains supply cannot be permanently disconnected, the isolation device (including
plug and socket) must be safeguarded against being switched on either unintentionally or
without authorisation.
Tip: We recommend connecting the tumble dryer to the power supply via a plug and
socket so that it is easier to conduct electrical safety checks (e.g. during maintenance or
repair work).
The tumble dryer must not be connected to devices such as timers which would switch
it off automatically.
If it is necessary to install a residual current device (RCD) in accordance with local regulations, a residual current device typeB (sensitive to universal current) must be used.
PDR914/514 G / Gas heated3
Installation notes
Gas connection
The gas connection must only be carried out by a registered installation technician in accordance with the applicable national regulations (see installation instructions).
The use of a gas socket is not permitted at the specified heater rating as the flow rate is
too low.
The gas heating is configured at the factory in line with the gas specifications on the
sticker on the rear of the appliance.
If the gas family is changed, a conversion kit must be requested from the Miele CustomerService Department (please specify the appliance type, serial number, gas family,
gas group, gas connection pressure and country of installation). Follow the installation instructions. This conversion may only be carried out by a registered specialist.
Supply air/exhaust air
The tumble dryer may only be operated when the ducting has been connected and the
room is sufficiently ventilated (see installation instructions).
Accessory parts may only be fitted when expressly approved by Miele. If other parts are
used, warranty, performance and product liability claims will be invalidated.
4PDR914/514 G / Gas heated
Dimensions
906
900>20>20
Ø 520
650
1400
595
Ø 630
20
1400
752
642
38
67
852
747
1300
1300
747
852
900
906
< 180°
PDR914/514, gas heated
Measurements in millimeters
PDR914/514 G / Gas heated5
PDR914/514, gas heated
620
280
90
G
501
305
1600
150
305
1600
~ 50
2 x
150
128
200
EL
AL
ZL
ZL
EL
AL
501
G
G
ZL
EL
AL
AL
ZL
161
160
"Z"
"Y"
"Y"
"Z"
XCI
96
31
~350
54
128
Installation
Measurements in millimeters
EL
Electrical connection
G
Gas connection
AL
ZL
XCI
Vented
Air intake
XCI-/Connector-Box (option)
6PDR914/514 G / Gas heated
Set up (Standard/Miele base)
20
1400
Ø 12
1400
UG
UG 900
B
~ 48
55
747
~ 55
127
Ø 10
~ 65
B
1300
55
790
395
754
900
546
B
B
A
A
UG 685
409
818
587
617
B
B
B
B
B
B
A - A
B - B
PDR914/514, gas heated
B
Fittings/drill hole
UG
Miele base
PDR914/514 G / Gas heated7
PDR914/514, gas heated
20
1400
M6 x 20
1400
BS
900
B
~ 48
>55
BS >900
>50
20
Ø 10
B
BS 1300
>55
790
395
754
BS >900
546
B
B
C
C
747
463
926
546
651
D
D
B
B
B
B
>50
BS
1300
790
55
55
103
395
BS
~55
OFFSHORE
C - C
D - D
~ 48
Set up (Concrete platform)
Measurements in inches
B
Fittings/drill hole
BS
Concrete platform
8PDR914/514 G / Gas heated
Technical data
Voltage variants/electrical data
Standard connection
Voltage1N AC 230V
Frequency50Hz
Total connected load0.6kW
Fuse rating (on-site)10A
Connection cable, min. cross-section3×1.5mm²
Cable glandM20
Gas connection
Nominal heat rating15kW
Machine-side connection according to ISO 7-1
To connect the gas appliance, a corrugated metal hose line made of stainless steel according to DIN3384
must be used. The shut-off device must be provided on-site. Due to an insufficient flow rate, the use of a
gas socket is not permissible with the specified heating output.
Connection thread for natural gas, on-site (internal thread)½"
Connection thread for liquid gas, on-site (internal thread)½"
Alternative on-site connection with high-precision steel pipe according to DIN 2391/DIN2393, with smooth
pipe end
Min. connection length
Connection pressure according to DIN EN 437. Connection to gas supply must comply with national regulations.
DN12
40mm
½"
Waste air/gas
Max. nominal air flow in vented mode (PDR9xx only)620m³/h
Max. nominal air flow (PDR5xx only)620m³/h
Max. permissible pressure loss280Pa
Connection on machine side (ext. diameter)150mm
Connection pipe provided on site (int. diameter)150mm
Max. temperature80°C
This tumble dryer is a gas-burning machine without a flow-operated safety device with fan downstream of heat exchanger (technical
design: B22). Waste gas pipework must be pressure-tight. Waste gas connections should be performed in accordance with national
and local regulations and may require approval.
As relative humidity inside the vent ducting can be as high as 100%, suitable measures must be taken to prevent a backflow of condensate into the machine.
Air intake
Standard connection: Air intake from installation site
Unobstructed air intake into room recommended:
(corresponding to 3 times the vent cross-section of machine).
A sufficient supply of fresh air should be ensured to replace the air extracted.
Alternative connection: Ducted air intake (from outside building)
Connector on machine (int. diameter)161mm
Connection pipe provided on site (ext. diameter)160mm
Lid removal exposes live components. For safety reasons, the pipe connected for central air intake should be at least 900mm long and
secured using two screws.
531cm²
Machine data
Overall machine width906mm
Overall machine height1400mm
PDR914/514 G / Gas heated9
Technical data
Overall machine depth852mm
Niche width1250mm
Recommended distance between front of machine and the wall1300mm
Minimum distance between rear edge of lid and the wall500mm
Packaging width1090mm
Packaging height1526mm
Packaging depth938mm
Maximum gross volume1560.2l
Maximum gross weight173.7kg
Maximum net weight162.4kg
Max. floor load in operation1799N
Exhaust air spigot diameter150mm
Drum diameter850mm
Drum opening diameter520mm
Drum depth480mm
Drum volume250l
Door opening diameter520mm
Max. door opening angle180°
Emission sound pressure level51 dB(A) re 20 µPa
Sound power level62
Heat dissipation rate to installation site3.9MJ/h
Permitted ambient temperature2–40°C
Mounting variants
Mounting without base
QuantityScrew size
Clamps2
Wood screws DIN 571 (Ø×lenght)26×40mm
Dowel (Ø×lenght)210×50mm
Machine must be bolted to the floor.
Fixing materials for a floating screed floor are to be provided on site.
Mounting on concrete platform
QuantityScrew size
Clamps2
Wood screws DIN 571 (Ø×lenght)26×40mm
Dowel (Ø×lenght)210×50mm
Machine must be bolted to the floor.
Fixing materials for a floating screed floor are to be provided on site.
10PDR914/514 G / Gas heated
Technical data
Optional extras
Concrete platform (on site)
Minimum width900mm
Recommended height100mm
Minimum height50mm
Minimum depth900mm
Quality and density of concrete must comply with load. Concrete platform must be firmly secured to floor.
PDR914/514 G / Gas heated11
Malaysia
Miele Sdn Bhd
Suite 12-2, Level 12
Menara Sapura Kencana Petroleum
Solaris Dutamas No. 1, Jalan Dutamas 1
50480 Kuala Lumpur, Malaysia
Phone: +603-6209-0288
Fax: +603-6205-3768
Miele New Zealand Limited
IRD 98 463 631
8 College Hill
Freemans Bay, Auckland 1011, NZ
Tel: 0800 464 353
Internet: www.miele.com.au/professional
E-mail: sales@miele-professional.com.au
Miele Australia Pty. Ltd.
ACN 005 635 398, ABN 96 005 635 398
1 Gilbert Park Drive, Knoxfield, VIC 3180
Tel: 1300 731 411
Internet: www.miele.com.au/professional
E-mail: sales@miele-professional.com.au
Australia
Miele Electrical Appliances Co., Ltd.
1-3 Floor, No. 82 Shi Men Yi Road
Jing' an District, 200040 Shanghai, PRC
Tel: +86 21 6157 3500, Fax: +86 21 6157 3511
E-mail: info@miele.cn, Internet: www.miele.cn
China Mainland
Miele (Hong Kong) Ltd.
41/F - 4101, Manhattan Place
23 Wang Tai Road, Kowloon Bay, Hong Kong
Tel: (852) 2610 1025, Fax: (852) 3579 1404
Email: customerservices@miele.com.hk
Website: www.miele.hk