Fully Integrated
36” MasterCool
K 2901 SF / K 2911 SF
F 2901 SF / F 2911 SF
KF 2901 SF / KF 2911 SF
KF 2981 SF
Shown: K 2981 SF
Please note: This information is subject to change
Specification Sheets TRS 05202019
8mieleusa.com

Pre-finished
36” MasterCool
SPECIFICATIONS
Overall Unit Dimensions 35
Overall Fascia Dimensions 36
Niche
Minimum Cabinet Niche Opening 36” (915 mm) W* x 84” - 85
Electrical
Electrical Requirements
Power Cord NEMA 5-15 plug, 5 ft (1.52 m)
Plumbing K 29x1 SF F 29x1 SF KF 29x1 SF
Water Supply Requirements -
Water Connection Line
Shipping
Shipping Weight 483 lbs (219 kg) 495 lbs (225 kg) 588 lbs (267 kg)
Shipping Dimensions 40” (1016 mm) W x 89
Support
Call Miele (800) 999-1360
Miele Website
20/20 Link
Please note the following:
• This specication sheet is for a single built-in unit.
• When combining multiple MasterCool units side-by-side, please refer to the Merging Kit specication sheet.
*If design calls for a partition less than 6 5/16” (160 mm) the left unit’s cutout will require an additional 1/8” (3 mm) to the width to allow installation of
the Heating Mat/Merge Kit.
3
/4” (908 mm) W x 833/4”- 853/16” (2127 - 2164 mm) H x 24” (610 mm) D [Excludes Fascia Dimension]
1
/2” (927 mm) W x 84”- 8511/16” (2134 - 2175 mm) H x 11/2” (32 mm) D
3
/16” (2134 - 2164 mm) H x 24” (610 mm) D
K 29x1 SF F 29x1 SF KF 29x1 SF
110V / 120V, 60Hz, 15 Amps
In the case of side-by-side installations, a separate outlet must be used for each appliance.
Connect to a cold water supply only. Do not connect to a low-mineral or
a reverse osmosis system. Must be connected to a shut-off valve. The
water shut-off valve must be accessible after installation. The water pressure must be between 29 psi (2 bar) and 116 psi (8 bar). If the pressure is
higher than 120 psi (8.3 bar), a pressure reducing valve must be installed.
-
Standard 1/4” O.D flexible water line. The maximum outer diameter of the
water pipe (without fittings): 3/8” (10 mm). Water line is not included.
K 29x1 SF F 29x1 SF KF 29x1 SF
13
/16” (1,294 mm) H x 291/4” (800 mm) D
8www.mieleusa.com
82020technologies.com
K 2901 SF (Right Hinged)
Item 36290111USA
K 2911 SF (Left Hinged)
Item 36291111USA
F 2901 SF (Right Hinged)
Item 37290111USA
F 2911 SF (Left Hinged)
Item 37291111USA
KF 2901 SF (Right Hinged)
Item 38290111USA
KF 2911 SF (Left Hinged)
Item 38291111USA
KF 2981 SF (French Door)
Item 38298111USA
Page 2 of 6

CUTOUT DIMENSIONS
Please note unit’s outer SF frame.
Top view:
Niche/Cabinetry
Pre-finished
36” MasterCool
3/4”
(19)
9/32”
(7)
SF frame
Stainless steel door
CUTOUT DETAILS
• The electrical connection must not be positioned higher
than 9” (228.6 mm) above the oor.
• The 1/4” (6.4 mm) plumbed water connection should
not be positioned higher than 2” (50.8 mm) above the
oor.
Notes:
In case of an emergency the electrical outlet must be
easily accessible and must not be concealed behind the
appliance.
Page 3 of 6

Pre-finished
36” MasterCool
POWER SUPPLY AND WATER CONNECTION
(Water Connection For F 29x1 SF & KF 29x1 SF Only)
Rear View Front View
Electrical - 5 foot (1.52 m) - 120 Volt - 15 Amp
- NEMA 5-15 molded plug
Water line - 1/4” exible water line - not included
Side View
Water connection is located in front of unit.
1/4” compression tting is needed.
Electrical
Connection
Page 4 of 6

HINGING DETAILS 115° OPENING
Available for the following models:
• K 29x1 SF
• F 29x1 SF
• KF 29x1 SF
1-1/4” (32 mm)
1-1/2” (38 mm)
1-3/4” (44 mm)
0-3/4” (19 mm)
1” (25 mm)
36” MasterCool
0-3/4” (19 mm)
Pre-finished
1/4”(6.4mm)
1/4”(6.4mm)
2-5/8”
(67mm)
2-5/8”
(67mm)
2-1/3” (59mm)
2-1/3” (59mm)
2-1/24”(52mm)
2-1/24”(52mm)
1-3/8”(35mm)
1-3/8”(35mm)
1-1/6”
1-1/6”
17/24” (18mm)
17/24” (18mm)
(29.6mm)
(29.6mm)
1-3/4”(44.5mm)
1-3/4”(44.5mm)
3”(76.2mm)
3”(76.2mm)
0-1/8” (3 mm)
1-1/2” (38 mm)
DOOR SWING AT 115° OPENING
1” (25 mm)
1-1/4” (32 mm)
11 3/4”
(298 mm)
Max
Page 5 of 6

HINGING DETAILS 90° OPENING
0-3/4"
1"
1-1/4"
1-1/2"
0-1/8"
F
ro
nt
Pa
n
el
0-3/4"
1-1/4"
1-1/2"
1-3/4"
1"
Cabinet Front
rooD °511rooD °09
snoitpo ssenkcihTsnoitpo ssenkcihT
Door Swing
14 3/8"
MAX
NOTE: Additional space needed depending on the thickness
of front panels and handle used.
Freezer units cannot be stop pinned at 90°
Available for the following models:
• K 29x1 SF
• KF 29x1 SF
2” (51 mm)
1-1/4” (32 mm)
1-3/4” (44 mm)
1-1/2” (38 mm)
0-3/4” (19 mm)
1” (25 mm)
Pre-finished
36” MasterCool
7/16”
(11 mm)
1-3/16”
(30mm)
1-7/16”
(36.5mm)
1-11/16”
(43mm)
1-15/16”
(49.2mm)
0-1/8” (3 mm)
Handle or object that is
NOT ush with Cabinet
Front.
DOOR SWING AT 90° OPENING
0-3/4” (19 mm)
1” (25 mm)
1-1/4” (32 mm)
1-1/2” (38 mm)
7/16” (11 mm)
/16” (982 mm)
11
38
When installing hinge side next to an appliance or object that is within range of the door panel,
limit the door opening angle to 90°. This is done by installing the banking pin as illustrated.
Insert the banking pin through the holes and drive in with a hammer.
Specification Sheets TRS 05202019