Fully Integrated
30” MasterCool
All Refrigerator:
K 2801 Vi / K 2811 Vi
All Freezer:
F 2801 Vi / F 2811 Vi
Bottom Mount:
KF 2801 Vi / KF 2811 Vi
Shown: F 2471 Vi merged with K 2801 Vi
Please note: This information is subject to change
Specification Sheets TRS 05202019
8mieleusa.com
Fully Integrated
30” MasterCool
SPECIFICATIONS
3
Overall Unit Dimensions 29
Niche
Minimum Cabinet Niche Opening 30” (762 mm) W* x 84” - 85
Electrical
Electrical Requirements
Power Cord NEMA 5-15 plug, 5 ft (1.52 m)
Plumbing K 28x1 Vi F 28x1 Vi KF 28x1 Vi
Water Supply Requirements -
Water Connection Line
Shipping
Shipping Weight 395 lbs (179 kg) 399 lbs (181 kg) 450 lbs (204 kg)
Shipping Dimensions 33
Support
Call Miele (800) 999-1360
Miele Website
20/20 Link
Please note the following:
• This specication sheet is for a single built-in unit.
• When combining multiple MasterCool units side-by-side, please refer to the Merging Kit specication sheet.
*If design calls for a partition less than 6 5/16” (160 mm) the left unit’s cutout will require an additional 1/8” (3 mm) to the width to allow installation of
the Heating Mat/Merge Kit.
/4” (756 mm) W x 833/4”- 853/16” (2127 - 2164 mm) H x 24” (610 mm) D [Depth does not include door panel]
3
/16” (2134 - 2164 mm) H x 243/4” (629 mm) D
K 28x1 Vi F 28x1 Vi KF 28x1 Vi
110V / 120V, 60Hz, 15 Amps
In the case of side-by-side installations, a separate outlet must be used for each appliance.
Connect to a cold water supply only. Do not connect to a low-mineral or
a reverse osmosis system. Must be connected to a shut-off valve. The
water shut-off valve must be accessible after installation. The water pressure must be between 29 psi (2 bar) and 116 psi (8 bar). If the pressure is
higher than 120 psi (8.3 bar), a pressure reducing valve must be installed.
-
Standard 1/4” O.D flexible water line. The maximum outer diameter of the
water pipe (without fittings): 3/8” (10 mm). Water line is not included.
K 28x1 Vi F 28x1 Vi KF 28x1 Vi
5
/8” (950 mm) W x 8913/16” (1,294 mm) H x 291/4” (800 mm) D
8www.mieleusa.com
82020technologies.com
K 2801 Vi (Right Hinged)
Item 36280101USA
K 2811 Vi (Left Hinged)
Item 36281101USA
F 2801 Vi (Right Hinged)
Item 37280101USA
F 2811 Vi (Left Hinged)
Item 37281101USA
KF 2801 Vi (Right Hinged)
Item 38280101USA
KF 2811 Vi (Left Hinged)
Item 38281101USA
Page 2 of 10
CUTOUT DIMENSIONS
• Niche depth assumes a 3/4” (19 mm) panel, please
adjust according to custom panel thickness
Fully Integrated
30” MasterCool
CUTOUT DETAILS
• The electrical connection must not be positioned higher
than 9” (228.6 mm) above the oor.
• The 1/4” (6.4 mm) plumbed water connection should
not be positioned higher than 2” (50.8 mm) above the
oor.
Notes:
In case of an emergency the electrical outlet must be
easily accessible and must not be concealed behind the
appliance.
Page 3 of 10