Miele G1262SC User Manual

Product and Cut-out Dimensions G1262SCVi Slimline Dishwasher
23" min.
C
17 3/4"
Location Codes
C -
Cutout (2 1/4" x 4") for water, drain and electric pass-through. Adjust according to water and drain location.
D -
5 foot flexible drain hose connects lower center rear.
E -
5 foot - 120 Volt - 15 Amp 3-wire molded plug power supply connects lower left rear.
W -
5 foot "Double Waterproof" flexible water intake hose connects lower center rear.
Notes
• All installations must be done in accordance with local codes
• Additional 2" in height may be attained by ordering extension feet
Water & Electrical
Connection
32 1/16" - 34 5/8"
D
W
E
1 3/8"
22 1/2"
5 1/2 min"
17 5/8"
32 1/16" - 34 5/8"
1 3/4" - 9"
4 5/8"
NOTE: Drawing is not to scale.
SPECIFICATION SHEETS 011008
Front Panel Information G1262SC Fully Integrated Models
Custom Panel Installations
Some Miele dishwashers do not come equipped with a front panel. These dishwashers are designed to accept a custom door panel supplied by the cabinet maker. Miele has a unique panel integration system which allows the dishwasher to align with the surrounding cabinets.
Panel size is determined in the following manner:
Miele
Fully
Integrated
Dishwasher
TKH
HTC
Panel Height
Width: 17 1/2" in all cases Thickness: 3/4" in all cases Height:Determined using the following calculation:
Panel Height = HTC - TKH
HTC = Height to the underside of countertop TKH = Toe-kick height
Note: Control panel is along the top edge of the unit. It
is not visible when the unit is closed. A handle MUST be located on the front panel in order to open the unit
Maximum panel height: 31 7/8" Minimum panel height: 27 3/16"
Maximum panel weight: 21 Pounds
GFVi Installations
Miele offers pre-fabricated stainless steel panels for all fully integrated units. These panels are designed for various toe-kick heights and offer a choice of handle options.
NOTE: Drawing is not to scale.
SPECIFICATION SHEETS 011008
Technical Information: Dishwashers
G2000 Series
32 1/16” - 34 5/8”
24”
Toe-kick height
2 1/2
3
3 1/2
4
1
4
5
1
5
6
6 1/2
7
1
7
8
1
8
9
Height to underside of countertop
1
32
/2 33 1/2 34
/2
/2
/2
/2
34
1
/2
3533
35
1
/2
36
Interior cabinet height For Fully Integrated installations
Water Connection
Dimension (A)
Dimension (B)
Option A
Option B
Acceptable combinations Typical American installation With extension feet
Connect via 3/4" hose bib
Connect via 3/4" adapter with 3/8" compression fitting
Waterproof System Box Dimensions
Width (A): 3 1/4" Height (B): 3 1/2" Thickness: 1 3/4"
Waterproof System
Temperature: 110° - 130° F Pressure: 4.5 - 145 PSI Drain hose: 7/8" ID - 5 feet long
Cutout: 2 1/4" x 4"
NOTE: Waterproof system box should ONLY be installed in a vertical manner to prevent build-up of water within box and possible leakage.