Miele F2811SF, F2801SF, K2811SF, K2801SF Specifications

Pre-finished 30” MasterCool II
K 2801 SF* / K 2811 SF*
F 2801 SF* / F 2811 SF*
KF 2801 SF / KF 2811 SF
Shown: F 2471 SF merged with K 2801 SF Please note: This information is subject to
*The following models are not available in Canada: K 2801 SF, K 2811 SF, F 2801 SF & F 2811 SF
Specification Sheets TRS 04252019
8miele.ca
Pre-finished
30” MasterCool II
SPECIFICATIONS
Overall Unit Dimensions 293/4” (756 mm) W x 833/4”- 853/16” (2127 - 2164 mm) H x 24” (610 mm) D [Excludes Fascia Dimension]
Overall Fascia Dimensions 301/2” (775 mm) W x 84”- 8511/16” (2134 - 2175 mm) H x 11/2” (32 mm) D
Niche
Minimum Cabinet Niche Opening 30” (762 mm) W* x 84” - 853/16” (2134 - 2164 mm) H x 24” (610 mm) D
Interior Volume K 28x1 SF F 28x1 SF KF 28x1 SF
Refrigeration Volume ** 0 **
Freezer Volume 0 ** *
Electrical
Electrical Requirements
Power Cord NEMA 5-15 plug, 5 ft (1.52 m)
Plumbing K 28x1 SF F 28x1 SF KF 28x1 SF
Water Supply Requirements -
K 28x1 SF F 28x1 SF KF 28x1 SF
110V / 120V, 60Hz, 15 Amps
In the case of side-by-side installations, a separate outlet must be used for each appliance.
Connect to a cold water supply only. Do not connect to a low-mineral or a reverse osmosis system. Must be connected to a shut-off valve. The water shut-off valve must be accessible after installation. The water pres­sure must be between 29 psi (2 bar) and 116 psi (8 bar). If the pressure is higher than 120 psi (8.3 bar), a pressure reducing valve must be installed.
Water Connection Line
Shipping
Shipping Weight 453 lbs (205.5 kg) 462 lbs (210 kg) 485 lbs (220 kg)
Shipping Dimensions 297/8” (759 mm) W x 841/4” (1,240 mm) H x 297/8” (759 mm) D
Support
Call Miele
Miele Website
20/20 Link
Please note the following:
• This specication sheet is for a single built-in unit.
• When combining multiple MasterCool units side-by-side, please refer to the Merging Kit specication sheet.
*If design calls for a partition less than 6 5/16” (160 mm) the left unit’s cutout will require an additional 1/8” (3 mm) to the width to allow installation of the Heating Mat/Merge Kit.
-
K 28x1 SF F 28x1 SF KF 28x1 SF
Standard 1/4” O.D flexible water line. The maximum outer diameter of the water pipe (without fittings): 3/8” (10 mm). Water line is not included.
(800) 565-6435
8www.miele.ca
82020technologies.com
K 2801 SF (Right Hinged)
K 2811 SF (Left Hinged)
F 2801 SF (Right Hinged)
F 2811 SF (Left Hinged)
KF 2801 SF (Right Hinged)
KF 2811 SF (Left Hinged)
Page 2 of 6