Miele F2811SF, F2801SF, K2811SF, K2801SF Specifications

Pre-finished 30” MasterCool II
K 2801 SF* / K 2811 SF*
F 2801 SF* / F 2811 SF*
KF 2801 SF / KF 2811 SF
Shown: F 2471 SF merged with K 2801 SF Please note: This information is subject to
*The following models are not available in Canada: K 2801 SF, K 2811 SF, F 2801 SF & F 2811 SF
Specification Sheets TRS 04252019
8miele.ca
Pre-finished
30” MasterCool II
SPECIFICATIONS
Overall Unit Dimensions 293/4” (756 mm) W x 833/4”- 853/16” (2127 - 2164 mm) H x 24” (610 mm) D [Excludes Fascia Dimension]
Overall Fascia Dimensions 301/2” (775 mm) W x 84”- 8511/16” (2134 - 2175 mm) H x 11/2” (32 mm) D
Niche
Minimum Cabinet Niche Opening 30” (762 mm) W* x 84” - 853/16” (2134 - 2164 mm) H x 24” (610 mm) D
Interior Volume K 28x1 SF F 28x1 SF KF 28x1 SF
Refrigeration Volume ** 0 **
Freezer Volume 0 ** *
Electrical
Electrical Requirements
Power Cord NEMA 5-15 plug, 5 ft (1.52 m)
Plumbing K 28x1 SF F 28x1 SF KF 28x1 SF
Water Supply Requirements -
K 28x1 SF F 28x1 SF KF 28x1 SF
110V / 120V, 60Hz, 15 Amps
In the case of side-by-side installations, a separate outlet must be used for each appliance.
Connect to a cold water supply only. Do not connect to a low-mineral or a reverse osmosis system. Must be connected to a shut-off valve. The water shut-off valve must be accessible after installation. The water pres­sure must be between 29 psi (2 bar) and 116 psi (8 bar). If the pressure is higher than 120 psi (8.3 bar), a pressure reducing valve must be installed.
Water Connection Line
Shipping
Shipping Weight 453 lbs (205.5 kg) 462 lbs (210 kg) 485 lbs (220 kg)
Shipping Dimensions 297/8” (759 mm) W x 841/4” (1,240 mm) H x 297/8” (759 mm) D
Support
Call Miele
Miele Website
20/20 Link
Please note the following:
• This specication sheet is for a single built-in unit.
• When combining multiple MasterCool units side-by-side, please refer to the Merging Kit specication sheet.
*If design calls for a partition less than 6 5/16” (160 mm) the left unit’s cutout will require an additional 1/8” (3 mm) to the width to allow installation of the Heating Mat/Merge Kit.
-
K 28x1 SF F 28x1 SF KF 28x1 SF
Standard 1/4” O.D flexible water line. The maximum outer diameter of the water pipe (without fittings): 3/8” (10 mm). Water line is not included.
(800) 565-6435
8www.miele.ca
82020technologies.com
K 2801 SF (Right Hinged)
K 2811 SF (Left Hinged)
F 2801 SF (Right Hinged)
F 2811 SF (Left Hinged)
KF 2801 SF (Right Hinged)
KF 2811 SF (Left Hinged)
Page 2 of 6
CUTOUT DIMENSIONS
Please note unit’s outer SF frame. Top view:
Niche/Cabinetry
3/4” (19)
9/32”
(7)
Pre-finished
30” MasterCool II
Stainless steel door
SF frame
CUTOUT DETAILS
The electrical connection must not be positioned higher
than 9” (228.6 mm) above the oor.
The 1/4” (6.4 mm) plumbed water connection should
not be positioned higher than 2” (50.8 mm) above the oor.
Notes: In case of an emergency the electrical outlet must be easily accessible and must not be concealed behind the appliance.
Page 3 of 6
Pre-finished
30” MasterCool II
POWER SUPPLY AND WATER CONNECTION (Water Connection For F 28x1 SF & KF 28x1 SF Only)
Rear View Front View
Electrical - 5 foot (1.52 m) - 120 Volt - 15 Amp
- NEMA 5-15 molded plug Water line - 1/4” exible water line - not included
Side View
Water connection is located in front of unit. 1/4” compression tting is needed.
Electrical Connection
Page 4 of 6
HINGING DETAILS 115° OPENING
Available for the following models:
• K 28x1 SF
• F 28x1 SF
• KF 28x1 SF
1-1/4” (32 mm)
1-1/2” (38 mm)
1-3/4” (44 mm)
0-3/4” (19 mm)
1” (25 mm)
30” MasterCool II
0-3/4” (19 mm)
Pre-finished
1/4”(6.4mm)
1/4”(6.4mm)
2-5/8”
(67mm)
2-5/8”
(67mm)
2-1/3” (59mm)
2-1/3” (59mm) 2-1/24”(52mm)
2-1/24”(52mm)
1-3/8”(35mm)
1-3/8”(35mm)
1-1/6”
1-1/6”
17/24” (18mm)
17/24” (18mm)
(29.6mm)
(29.6mm)
1-3/4”(44.5mm)
1-3/4”(44.5mm)
3”(76.2mm)
3”(76.2mm)
0-1/8” (3 mm)
DOOR SWING AT 115° OPENING
1-1/4” (32 mm)
1-1/2” (38 mm)
11 3/4”
(298 mm)
Max
1” (25 mm)
Page 5 of 6
HINGING DETAILS 90° OPENING
Available for the following models:
• K 28x1 SF
• KF 28x1 SF
1-1/4” (32 mm)
1-3/4” (44 mm)
1-1/2” (38 mm)
2” (51 mm)
0-3/4” (19 mm)
1” (25 mm)
Pre-finished
30” MasterCool II
7/16”
(11 mm) 1-3/16” (30mm)
1-7/16” (36.5mm)
1-11/16” (43mm)
1-15/16” (49.2mm)
0-1/8” (3 mm)
Handle or object that is
NOT ush with Cabinet
Front.
DOOR SWING AT 90° OPENING
0-3/4” (19 mm)
1” (25 mm)
1-1/4” (32 mm)
1-1/2” (38 mm)
7/16” (11 mm)
/16” (830 mm)
11
32
When installing hinge side next to an appliance or object that is within range of the door panel, limit the door opening angle to 90°. This is done by installing the banking pin as illustrated. Insert the banking pin through the holes and drive in with a hammer.
Specification Sheets TRS 04252019
Page 6 of 6
Loading...