Introduction
Thank you for selecting an MGE UPS SYSTEMS product to protect your electrical equipment.
The Comet EXtreme range has been designed with the utmost care. We recommend that you take the time to read this manual to take full advantage of the many features of your UPS.
MGE UPS SYSTEMS pays great attention to the environmental impact of its products. Measures that have made Comet EXtreme a reference in environmental protection include:Production in an ISO 14001 certified factory;
Recycling of Comet EXtreme at the end of its service life.
To discover the entire range of MGE UPS SYSTEMS products and the options available for the Comet EXtreme range:
We invite you to visit our Web site at www.mgeups.com
(page: www.mgeups.com/products/pdt230/smallups/extreme/extrem10.htm),Or contact your MGE UPS SYSTEMS representative.
Page 2 - 51033212EN/AC
Foreword
Using this document
Information may be found primarily by consulting:the contents,
the index.
Pictograms
Important instructions that must always be followed.
Information, advice, help.
Visual indication.
Action.
Audio indication.
In the illustrations on the following pages, the symbols below are used:
LED off.
LED on.
LED flashing.
51033212EN/AC - Page 3
Contents
1.Presentation
1.1 |
Comet EXtreme range .................................................................................................................. |
6 |
|
4.5 and 6 kVA tower models ........................................................................................................... |
6 |
|
4.5 and 6 kVA rack models ............................................................................................................. |
6 |
|
9 and 12 kVA tower models ............................................................................................................ |
7 |
|
9 and 12 kVA rack models .............................................................................................................. |
7 |
1.2 |
Back ............................................................................................................................................... |
8 |
|
Comet EXtreme 4.5 and 6 kVA ...................................................................................................... |
8 |
|
Comet EXtreme 9 and 12 kVA ....................................................................................................... |
8 |
1.3 |
Options .......................................................................................................................................... |
9 |
|
EPO (Emergency Power Off) .......................................................................................................... |
9 |
|
Transformer for galvanic isolation or earthing arrangement change .............................................. |
9 |
|
Battery extensions for UPS backup times of 80 minutes ................................................................ |
9 |
|
CLA module (Long backup time charger) for backup times of 2 to 8 hours .................................. |
10 |
1.4 |
Control panel ............................................................................................................................... |
11 |
2.Installation
2.1 |
Unpacking and checks ............................................................................................................... |
12 |
|
Comet EXtreme 4.5 and 6 kVA .................................................................................................... |
12 |
|
Comet EXtreme 9 and 12 kVA ..................................................................................................... |
13 |
2.2 |
Installation of the rack version .................................................................................................. |
14 |
2.3 |
Battery-module connections ..................................................................................................... |
15 |
|
Comet EXtreme 4.5 and 6 kVA .................................................................................................... |
15 |
|
Comet EXtreme 9 and 12 kVA ..................................................................................................... |
15 |
2.4 |
Connection to the RS 232 communications port (optional) ................................................... |
16 |
2.5 |
Installation of the communications-card option ...................................................................... |
16 |
2.6 |
Connection to the connection modules ................................................................................... |
17 |
3.Operation
3.1 |
ON LINE operating mode ........................................................................................................... |
18 |
3.2 |
Start-up ........................................................................................................................................ |
19 |
3.3 |
Bargraph indications .................................................................................................................. |
19 |
Page 4 - 51033212EN/AC
|
|
Contents |
3.4 Failure of AC input power and operation on battery power |
.................................................... 20 |
|
|
Transfer to battery power .............................................................................................................. |
20 |
|
Threshold for the low-battery shutdown warning .......................................................................... |
20 |
|
End of backup time ....................................................................................................................... |
20 |
|
Sleep mode ................................................................................................................................... |
20 |
|
Return of AC input power .............................................................................................................. |
20 |
3.5 |
Personalization ........................................................................................................................... |
21 |
|
Function ........................................................................................................................................ |
21 |
|
"ON / OFF conditions" tab ............................................................................................................. |
21 |
|
"Battery" tab .................................................................................................................................. |
22 |
|
"Output" tab ................................................................................................................................... |
22 |
|
"By-pass" tab ................................................................................................................................ |
22 |
3.6 |
Shutdown..................................................................................................................................... |
23 |
|
Shutdown of connected equipment............................................................................................... |
23 |
|
Complete shutdown of the UPS .................................................................................................... |
23 |
4.Maintenance
4.1 |
Troubleshooting .......................................................................................................................... |
24 |
4.2 |
Replacement of the electronic module ..................................................................................... |
26 |
|
Disconnecting the connection module .......................................................................................... |
26 |
|
Reconnecting the connection module ........................................................................................... |
27 |
5. Environment ..................................................................................................................................... |
28 |
6.Appendices
6.1 |
Glossary....................................................................................................................................... |
29 |
6.2 |
Index............................................................................................................................................. |
31 |
51033212EN/AC - Page 5
1. Presentation
1.1Comet EXtreme range
4.5and 6 kVA tower models
4.5 and 6 kVA rack models
|
Dimensions in mm |
|
(H x W x D) |
Electronic module |
443 x 173 x 465 |
Battery module |
443 x 173 x 465 |
|
|
|
|
|
Weight in kg |
|
|
Electronic module |
14 |
Battery module |
48 |
|
Dimensions in mm |
|
(H x W x D) |
Electronic module |
177 (4U) x 483 x 462 |
Battery module |
177 (4U) x 483 x 462 |
|
|
|
Weight in kg |
|
|
Electronic module |
18 |
Battery module |
51 |
Page 6 - 51033212EN/AC
1. Presentation
9 and 12 kVA tower models
9 and 12 kVA rack models
|
Dimensions in mm |
|
(H x W x D) |
Electronic module |
443 x 216 x 465 |
Battery module |
443 x 173 x 465 |
|
|
|
Weight in kg |
|
|
Electronic module |
22 |
Battery module |
48 |
|
Dimensions in mm |
|
(H x W x D) |
Electronic module |
221 (5U) x 483 x 462 |
Battery module |
177 (4U) x 483 x 462 |
|
|
|
Weight in kg |
|
|
Electronic module |
27 |
Battery module |
51 |
51033212EN/AC - Page 7
1. Presentation
1.2 Back
Comet EXtreme 4.5 and 6 kVA
1 RS232 communications port.
2 |
Battery circuit breaker. |
3 Communications-card option.
4 |
EXB battery module connectors. |
5 |
Connector for battery extension modules. |
6 |
Rating plate. |
7 |
Manual by-pass switch. |
8 |
Connection module. |
9 |
Output terminal block. |
10 |
Input terminal block. |
Comet EXtreme 9 and 12 kVA
4 EXB battery modules connectors.
Page 8 - 51033212EN/AC
1. Presentation
1.3 Options
EPO (Emergency Power Off)
Available for both tower and rack versions of UPSs with standard backup times and for the battery extensions, the EPO (Emergency Power Off) option lets you simultaneously switch off the UPS battery circuit breaker and the upstream circuit breaker of your installation by connecting both of them to a single emergency off button (not supplied).
For more details, visit our Web site: www.mgeups.com/products/pdt230/smallups/extreme/epo.htm
Transformer for galvanic isolation or earthing arrangement change
|
Comet EXtreme |
Comet EXtreme |
|
Transfo 4.5 - 6 kVA |
Transfo 9 - 12 kVA |
|
|
|
Nominal power |
6 kVA |
12 kVA |
|
|
|
Nominal current |
32 A |
63 A |
Input voltage |
230V (+15%, -20%) |
230V (+15%, -20%) |
Voltage drop |
2.2% |
1.7% |
Frequency |
50/60 Hz (+/-10%) |
50/60 Hz (+/-10%) |
|
|
|
Isolation (EN 61558-1-2-4) |
3.75 kV / 5 M ohms |
3.75 kV / 5 M ohms |
|
|
|
Operating temperature |
From 0° to +40° C |
From 0° to +40° C |
|
|
|
Max. operating rel. humidity |
95% |
95% |
Derating / altitude |
Pn-10% > 1000 m |
Pn-10% > 1000 m |
Natural ventilation |
IP20 ANAN |
IP20 ANAN |
Dimensions HxWxD (tower) |
443 x 173 x 465 mm |
443 x 216 x 465 mm |
Dimensions HxWxD (rack 4U) |
177 x 483 x 462 mm |
177 x 483 x 462 mm |
Weight (tower) |
44 kg |
62 kg |
Weight (rack) |
48 kg |
67 kg |
|
|
|
Important: to simplify installation, connect the Comet EXtreme Transformer downsteam of the UPSs. Visit our Web site: www.mgeups.com/products/pdt230/smallups/extreme/transfo.htm
Battery extensions for UPS backup times of 80 minutes
Battery extensions for 4.5 or 6 kVA Comet EXtreme:
|
|
|
|
|
Comet |
|
|
Comet |
|
|
Comet |
Comet |
|||
Comet |
EXtreme |
+ |
EXtreme |
+ |
EXtreme |
+ |
EXtreme |
EXtreme |
|||||||
EXB |
EXB |
EXB |
EXB |
||||||||||||
4.5 / |
6 kVA |
||||||||||||||
|
|
|
|
|
4.5 / |
|
|
4.5 / |
|
|
|
4.5 / |
4.5 / |
|
|
|
|
|
|
|
6 kVA |
|
|
6 kVA |
|
|
6 kVA |
6 kVA |
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Comet EXtreme offers a standard backup time of 9/12 minutes.
To increase backup time, it is possible to connect Comet EXtreme EXB modules to the UPSs.
Visit our Web site: www.mgeups.com/ products/pdt230/smallups/extreme/ guide.htm.
4.5 kVA: |
12 min |
30 min |
54 min |
80 min |
6 kVA: |
9 min |
23 min |
40 min |
75 min |
51033212EN/AC - Page 9
1. Presentation
Battery extensions for 9 or 12 kVA Comet EXtreme:
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Comet |
|
|
Comet |
|
|
|
Comet |
Comet |
|
|||||
Comet EXtreme |
+ |
+ |
|
+ |
|
|||||||||||||||
EXtreme |
EXtreme |
|
EXtreme |
EXtreme |
|
|||||||||||||||
9 / 12 kVA |
EXB |
EXB |
|
EXB |
EXB |
|
||||||||||||||
|
|
|
|
|
|
9 / 12 kVA |
|
|
9 / 12 kVA |
|
|
|
9 / 12 kVA |
9 / 12 kVA |
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
9 kVA: |
12 min |
30 min |
45 min |
80 min |
12 kVA: |
9 min |
23 min |
40 min |
75 min |
The Comet EXtreme EXB modules are available in "tower" and in "rack" models.
The Comet EXtreme EXB modules come with their connection cables.
CLA module (Long backup time charger) for backup times of 2 to 8 hours
Very long backup times, from 2 to 8 hours at full load, require a Comet EXtreme CLA module.
Visit our Web site: www.mgeups.com/products/pdt230/smallups/extreme/cla/cla2.htm.
Comet
EXtreme
-65Ah 12V
Comet
EXtreme
CLA
25A
2
1
-65Ah 12V
-65Ah 12V
19
-65Ah 12V
2 h
20
-65Ah 12V
1 |
2 |
|
-65Ah |
||
|
||
|
12V |
|
-65Ah |
-65Ah |
|
12V |
12V |
|
|
-65Ah |
|
12V |
|
20 |
19 |
-65Ah |
|
|
|
12V |
-65Ah |
-65Ah |
12V |
12V |
|
-65Ah |
12V |
4 h
1 |
2 |
|
-65Ah |
||
|
||
|
12V |
|
-65Ah |
-65Ah |
|
12V |
12V |
|
12V |
-65Ah |
|
12V |
||
|
-65Ah |
|
|
12V |
20 |
|
19 |
-65Ah |
|
|
12V |
|
-65Ah |
12V |
12V |
|
-65Ah |
-65Ah |
12V |
12V |
-65Ah |
|
12V |
|
8 h
Page 10 - 51033212EN/AC