These installation instructions cover the outdoor installation of
split system heat pumps from 7-½ to 10 tons. See the product
catalog applicable to your model for information regarding
specifications applicable to your model and accessories.
Receiving Inspection
McQuay products are carefully inspected prior to shipment
and the carrier has assumed responsibility for loss or damage
upon acceptance of the shipment.
Upon receiving your shipment, check all items carefully
against the Bill of Lading. Inspect the unit and/or accessories
for shipping damage as soon as they are received. Immedi
ately file claims for loss or damage, either shipping or concealed, with the shipping company.
Check the unit nameplate to verify the model number and electrical characteristics are correct. In the event an incorrect unit
is shipped, it must be returned to the supplier and must NOT
be installed. The manufacturer disclaims all responsibility for
the installation of incorrectly shipped units.
Codes and Regulations
This product is designed and manufactured to permit installation in accordance with National Codes. System design should,
where applicable, follow information presented in accepted
industry guides such as the ASHRAE Handbooks. It is the
installer' s responsibility to install the product in accordance
with National Codes and/or prevailing local codes and regula
tions. The manufacturer disclaims all responsibility for equip-
ment installed in violation of any code or regulations.
Important Message to the Owner
Read these instructions carefully and keep them near the product for future reference. Although these instructions are
addressed primarily to the installer, useful maintenance infor
mation is included. Have the installer acquaint you with the
operation of the product and periodic maintenance require
ments.
Recognize Safety Symbols, Words, and Labels
The following symbols and labels are used throughout this
manual to indicate immediate or potential hazards. It is the
owner's and installer's responsibility to read and comply with
-
all safety information and instructions accompanying these
symbols. Failure to heed safety information increases the risk
of property damage and/or product damage, serious personal
injury or death. Improper installation, operation and mainte
nance can void the warranty.
DANGER
Immediate hazards which WILL result in property
damage, product damage, severe personal injury and/
or death.
WARNING
-
Hazards or unsafe practice CAN result in property
damage, product damage, sever personal injury and/or
death.
-
-
-
IMPORTANT
The United States Environmental Protection Agency
(EPA) regulations cover introduction and disposal of
refrigerants in this unit. Failure to follow those
regulations can harm the environment and lead to
substantial fines. Because regulations can change, a
certified technician should perform any work done on
this unit. If you have any questions, please contact the
local office of the EPA.
Important Message to the Installer
This equipment is to be installed by an experienced installation
company and fully trained personnel. Carefully read all
instructions and take into account any special considerations
prior to installing the unit. Give this manual to the owner and
explain its provisions.
CAUTION
Hazards or unsafe practices which CAN result in
property damage, product damage, and/or personal
injury.
Replacement Parts
Replacement parts can be obtained by contacting McQuay at
1
-800-37-PARTS. When contacting McQuay for service or
replacement parts, refer to the model number and serial num
ber of the unit as stamped on the nameplate attached to the
unit.
-
Page 4 IM-811
GENERAL WARNINGS
WARNING
Before servicing or installing this equipment, the
electrical power to this unit must be in the "OFF"
position. More than one disconnect may exist. Failure
to disconnect power can cause electrical shock, serious
personal injury or death.
WARNING
The unit must have an uninterrupted, unbroken
electrical ground. Failure to properly ground can cause
severe personal injury or death.
DANGER
Installation and service by trained, qualified technicians
only. High pressure and electricity can cause severe
personal injury or death. Observe ALL warnings
contained in this manual and the labels/tags attached to
the equipment.
WARNING
When installing or servicing this equipment wear
protective gloves, gear and eyeware. Also observe
special safety requirements (hard hats etc.).
CAUTION
To protect the unit when welding close to the painted
surfaces, use a quenching cloth to prevent scorching or
marring of the equipment finish.
IM-811 Page 5
PRODUCT DESCRIPTION
When matched with the appropriate air handler(s) or evaporator coil(s) the AHP090/120 heat pump complies with the minimum efficiency equirements found in ASHRAE 90.1-1999.
See the product catalog for the indoor model selection recom
mendation.
Units operate in the same manner as most heat pumps. However, these products use a TXV in lieu of a flowrater/piston
system for refrigerant management.
Units are intended for use with a single stage room thermostat. This thermostat is not supplied with this equipment. Only
thermostats that use 24-volt control circuitry are to be used.
Table 2: Physical Data
Net Weight (Lbs.)365415
Shipping Weight (Lbs.)390440
RefrigerantR-22
Compressor TypeScroll
Quantity1
Oil Charge Initial/Recharge85/81110/106
Condenser Fan TypePropeller
Fan Diameter (in)26
Fan Motor TypeDirect Drive PCS
Fan Motor (HP)1
Fan Motor (RPM)110 0
Nominal Cond. Airflow (CFM)6600
Condenser Coil MaterialRiffled Copper Tubes / Al Fins
Face Area (Ft2)
Refrigerant ConnectionsSweat Type
Suction Line Connection (in)1-3/8
Liquid Line Connection (in)5/8
High Pressure Control (PSIG)425 Cut-out / Manual Reset
Low Pressure Control (PSIG)7 Cut-out / 25 Cut-in
Thermal Expansion Valve1
AHP090AHP120
30
DUCKWORK CONSIDERATIONS
For proper performance, size the indoor ductwork to accommodate 375-425 CFM per ton of cooling with a static pressure
not to exceed .5" WC. Inadequate ductwork that restricts air
flow can result in improper cooling performance and compressor failure.
SITE SELECTION
This unit is designed for outdoor installations only.
Air Supply
Units are air-cooled heat pumps. To provide optimum unit
performance, the installation site should provide unobstructed
airflow. See Figure 1 for minimum clearances from other aircooled condensers/heat pumps and obstructions such as walls
or overhangs.
Figure 1. Recommended Clearances
60"
12"
-
12"
24"
Refrigerant System Requirements
The selected site should be no greater than 50’ below or 70’
above the evaporator section. For optimum performance, use
the minimum length of interconnecting tubing. Where possi
ble, minimize the amount of bends and turns.
Wiring and Tubing Protection
Electrical wiring and refrigerant tubing is to be protected from
damage due to incidental contact, such as being walked upon.
Vibration and Sound Control
Units are engineered to produce the minimum sound and
vibration. To minimize sound or vibration issues, securely
mount the unit to a surface that is:
•Solid
• Greatest practical mass
•Ridged
• Minimum radiating surface
Where possible, the slab for a ground level unit should not be
connected to the wall or the building.
Prohibited Locations
Do not locate this unit in the following locations:
• Inside a building
• Directly under a vent termination from a gas appliance
• Within 3 feet of a gas appliance vent
• Where water may rise into the unit
12"
-
Note: Adequate service clearances must also be consid-
ered.
Page 6 IM-811