McQuay AHP090APEY Installation Manual

Installation and Maintenance Manual IM-811
AHP Split System Heat Pump
7-1/2 & 10 TON
Group: Unitary
Part Number: IM-811
Date: August 2005
Supersedes: March 2005
IM-811 Page 1
Table of Contents
MODEL NOMENCLATURE . . . . . . . . . . . . . . . . . . . . . . . 3
INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
GENERAL WARNINGS . . . . . . . . . . . . . . . . . . . . . . . . . . 5
PRODUCT DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . 6
DUCKWORK CONSIDERATIONS . . . . . . . . . . . . . . . . . 6
SITE SELECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
TYPICAL INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . 7
RIGGING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
UNIT CORNER WEIGHT . . . . . . . . . . . . . . . . . . . . . . . . . 7
REFRIGERANT TUBING . . . . . . . . . . . . . . . . . . . . . . . . . 7
ELECTRICAL WIRING. . . . . . . . . . . . . . . . . . . . . . . . . . . .9
SYSTEM EVACUATION AND CHARGING . . . . . . . . .11
SYSTEM EVACUATION . . . . . . . . . . . . . . . . . . . . . . . . .12
PRELIMINARY CHARGE ADJUSTMENT . . . . . . . . . .12
FINAL CHARGE ADJUSTMENT . . . . . . . . . . . . . . . . . .13
EXPANSION VALVE INDOOR COILS . . . . . . . . . . . . .14
DEFROST CONTROL (DC) . . . . . . . . . . . . . . . . . . . . . . .14
TROUBLE SHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . .15
TROUBLE SHOOTING - Heating . . . . . . . . . . . . . . . . . .16
WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
"McQuay" is a registered trademark of McQuay International.
© 2004 McQuay International
"Illustrations and information cover the McQuay International products at the time of publication and we reserve the right to make changes in
Page 2 IM-811
design and construction at any time without notice."
MODEL NOMENCLATURE
M
A
N
0 1
0
A
odel
HP = Air Cooled Heat Pump
ominal Capacity (tons)
90 = 7-1/2 20 = 10
Table 1: Unit Nameplate Model Number Identifier
Unit Nameplate McQuay Model Number
CPLE090-3C AHP090APEY CPLE090-4C AHP090AQEY CPLE120-3C AHP120APEY CPLE120-4C AHP120AQEY
AHP 090
PEY
Future Use EER
E = 10.1
Voltage/Phase
P = 208-230/3/6 Q = 460/3/60
Vintage
IM-811 Page 3
INTRODUCTION
General Description
These installation instructions cover the outdoor installation of split system heat pumps from 7-½ to 10 tons. See the product catalog applicable to your model for information regarding specifications applicable to your model and accessories.
Receiving Inspection
McQuay products are carefully inspected prior to shipment and the carrier has assumed responsibility for loss or damage upon acceptance of the shipment.
Upon receiving your shipment, check all items carefully against the Bill of Lading. Inspect the unit and/or accessories for shipping damage as soon as they are received. Immedi ately file claims for loss or damage, either shipping or con­cealed, with the shipping company.
Check the unit nameplate to verify the model number and elec­trical characteristics are correct. In the event an incorrect unit is shipped, it must be returned to the supplier and must NOT be installed. The manufacturer disclaims all responsibility for the installation of incorrectly shipped units.
Codes and Regulations
This product is designed and manufactured to permit installa­tion in accordance with National Codes. System design should, where applicable, follow information presented in accepted industry guides such as the ASHRAE Handbooks. It is the installer' s responsibility to install the product in accordance with National Codes and/or prevailing local codes and regula tions. The manufacturer disclaims all responsibility for equip-
ment installed in violation of any code or regulations.
Important Message to the Owner
Read these instructions carefully and keep them near the prod­uct for future reference. Although these instructions are addressed primarily to the installer, useful maintenance infor mation is included. Have the installer acquaint you with the operation of the product and periodic maintenance require ments.
Recognize Safety Symbols, Words, and Labels
The following symbols and labels are used throughout this manual to indicate immediate or potential hazards. It is the owner's and installer's responsibility to read and comply with
-
all safety information and instructions accompanying these symbols. Failure to heed safety information increases the risk of property damage and/or product damage, serious personal injury or death. Improper installation, operation and mainte nance can void the warranty.
DANGER
Immediate hazards which WILL result in property damage, product damage, severe personal injury and/ or death.
WARNING
-
Hazards or unsafe practice CAN result in property damage, product damage, sever personal injury and/or death.
-
-
-
IMPORTANT
The United States Environmental Protection Agency (EPA) regulations cover introduction and disposal of refrigerants in this unit. Failure to follow those regulations can harm the environment and lead to substantial fines. Because regulations can change, a certified technician should perform any work done on this unit. If you have any questions, please contact the local office of the EPA.
Important Message to the Installer
This equipment is to be installed by an experienced installation company and fully trained personnel. Carefully read all instructions and take into account any special considerations prior to installing the unit. Give this manual to the owner and explain its provisions.
CAUTION
Hazards or unsafe practices which CAN result in property damage, product damage, and/or personal injury.
Replacement Parts
Replacement parts can be obtained by contacting McQuay at 1
-800-37-PARTS. When contacting McQuay for service or replacement parts, refer to the model number and serial num ber of the unit as stamped on the nameplate attached to the unit.
-
Page 4 IM-811
GENERAL WARNINGS
WARNING
Before servicing or installing this equipment, the electrical power to this unit must be in the "OFF" position. More than one disconnect may exist. Failure to disconnect power can cause electrical shock, serious personal injury or death.
WARNING
The unit must have an uninterrupted, unbroken electrical ground. Failure to properly ground can cause severe personal injury or death.
DANGER
Installation and service by trained, qualified technicians only. High pressure and electricity can cause severe personal injury or death. Observe ALL warnings contained in this manual and the labels/tags attached to the equipment.
WARNING
When installing or servicing this equipment wear protective gloves, gear and eyeware. Also observe special safety requirements (hard hats etc.).
CAUTION
To protect the unit when welding close to the painted surfaces, use a quenching cloth to prevent scorching or marring of the equipment finish.
IM-811 Page 5
PRODUCT DESCRIPTION
When matched with the appropriate air handler(s) or evapora­tor coil(s) the AHP090/120 heat pump complies with the mini­mum efficiency equirements found in ASHRAE 90.1-1999. See the product catalog for the indoor model selection recom mendation.
Units operate in the same manner as most heat pumps. How­ever, these products use a TXV in lieu of a flowrater/piston system for refrigerant management.
Units are intended for use with a single stage room thermo­stat. This thermostat is not supplied with this equipment. Only thermostats that use 24-volt control circuitry are to be used.
Table 2: Physical Data
Net Weight (Lbs.) 365 415
Shipping Weight (Lbs.) 390 440
Refrigerant R-22
Compressor Type Scroll
Quantity 1
Oil Charge Initial/Recharge 85/81 110/106
Condenser Fan Type Propeller
Fan Diameter (in) 26
Fan Motor Type Direct Drive PCS
Fan Motor (HP) 1
Fan Motor (RPM) 110 0
Nominal Cond. Airflow (CFM) 6600
Condenser Coil Material Riffled Copper Tubes / Al Fins
Face Area (Ft2)
Refrigerant Connections Sweat Type
Suction Line Connection (in) 1-3/8
Liquid Line Connection (in) 5/8
High Pressure Control (PSIG) 425 Cut-out / Manual Reset
Low Pressure Control (PSIG) 7 Cut-out / 25 Cut-in
Thermal Expansion Valve 1
AHP090 AHP120
30
DUCKWORK CONSIDERATIONS
For proper performance, size the indoor ductwork to accom­modate 375-425 CFM per ton of cooling with a static pressure not to exceed .5" WC. Inadequate ductwork that restricts air flow can result in improper cooling performance and compres­sor failure.
SITE SELECTION
This unit is designed for outdoor installations only.
Air Supply
Units are air-cooled heat pumps. To provide optimum unit performance, the installation site should provide unobstructed airflow. See Figure 1 for minimum clearances from other air­cooled condensers/heat pumps and obstructions such as walls or overhangs.
Figure 1. Recommended Clearances
60"
12"
-
12"
24"
Refrigerant System Requirements
The selected site should be no greater than 50’ below or 70’ above the evaporator section. For optimum performance, use the minimum length of interconnecting tubing. Where possi ble, minimize the amount of bends and turns.
Wiring and Tubing Protection
Electrical wiring and refrigerant tubing is to be protected from damage due to incidental contact, such as being walked upon.
Vibration and Sound Control
Units are engineered to produce the minimum sound and vibration. To minimize sound or vibration issues, securely mount the unit to a surface that is:
•Solid
• Greatest practical mass
•Ridged
• Minimum radiating surface
Where possible, the slab for a ground level unit should not be
­connected to the wall or the building.
Prohibited Locations
Do not locate this unit in the following locations:
• Inside a building
• Directly under a vent termination from a gas appliance
• Within 3 feet of a gas appliance vent
• Where water may rise into the unit
12"
-
Note: Adequate service clearances must also be consid-
ered.