Mammoth Classic User Manual

For Air as Pure as the Ice Age
Classic
TM
Air Purier
USER GUIDE
R
Mammoth ClassicTM Air Purier User Guide
© 2015 Mammoth Classic Air Purier | Version 2015
2
PLEASE READ ALL OF THE INFORMATION PROVIDED IN THIS USER’S GUIDE
BEFORE OPERATING YOUR NEW AIR UNIT.
WARNING: This air unit is not a medical device. Do not stop or alter any medical
therapy programs or medications without the advice of your physician. Excessive ozone concentrations may cause mucous membrane or respiratory irritation.
CAUTION: This unit is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision concerning use of the unit by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the unit.
CAUTION: TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT REMOVE
BACK COVER. NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL
This “EXCLAMATION POINT” calls attention to a feature for which you should read the enclosed literature carefully to prevent operating and maintenance problems.
This “BOLT OF LIGHTNING” indicates that insulated material within your unit may cause an electrical shock. For the safety of everyone, do not remove product covering.
RISK OF ELECTRICAL SHOCK DO NOT OPEN UNIT
WARNING!
TM
Air Purier User Guide
Visit us at: www.mpurier.com For Questions Call: 800.470.4201
3
Congratulations on your purchase of the Mammoth ClassicTM Air Purier! This air purier is crated with our love and care, using only quality components with the latest Mammoth IceTech
TM
air purication technology. We hope that you will enjoy
your purchase for years to come.
READ ALL INSTRUCTIONS CAREFULLY BEFORE USING THIS PRODUCT
Please record the serial number and information below for easy reference. These numbers are located on the back panel of your air purier. These information will help with warranty request.
Model number: Mammoth ClassicTM Air Purier
Serial Number:________________________________________
Date of Purchase:______________________________________
Purchased From:______________________________________
FOR YOUR RECORDS
Mammoth ClassicTM Air Purier User Guide
© 2015 Mammoth Classic Air Purier | Version 2015
4
Ozonator
Fan Speed On/Off control switch controls the fan speed. At full speed, (On/Off) & Ionizer the fan will draw maximum amount of air and thus loudest. Ionizer & UV* will automatically turn on once the unit is on.
Ozonator Ozone generator will only turn ON when user turns the Ozone dial Clockwise (low to high). This function can be left OFF while the Fan is ON if Ozone is not desired (recommended setting for most occasions) until needed.
Fan Grill Removable fan grill. Wash with warm soapy water, dry completely before replacing. (Unplug unit before removing)
PART FUNCTION
Ionizer Prong
Front Grill
Control for the negative ion generator is separate from the O3 control. Negative ions can be created around the clock to keep down dust and particulate.
O3, also known as ozone, can be used at modest levels in occupied spaces. To
remove heavy odor, turn the dial clockwise to increase O3 production for a short period of time. Another way to use the ozone feature is to use a timer to completely deodorize the home or ofce left at the highest setting while away. Unused O3 reverts back to normal oxygen molecule in about 30 minutes.
NOTE: As you stand in front of the unit the ionizer will create a slight charge. If
you then touch a metal object there may be a static electric discharge similar to touching a doorknob in winter.
UNDERSTANDING YOUR AIR PURIFIER (FRONT VIEW)
TM
Air Purier User Guide
Visit us at: www.mpurier.com For Questions Call: 800.470.4201
5
Ozone Plate Slot Allows insertion and removal of ceramic plates for cleaning. (Arrows points towards front of unit)
Fuse Holder Houses removable fuse. (Spare fuse included, 1 amp, 1.25 inch)
Power Cord 120 Volt grounded cord (unless otherwise specied). DO NOT bypass ground wire cord.
Ceramic Plate The Ceramic Plate is removable and washable. Wash with (Held in Plate Slot) ammonia and water using a stiff brush or toothbrush. Rinse & dry completely before replacing. (If burnt, replace.)
IceTechTM HEPA Filter HEPA lter can be replaced by taking off the screws. HEPA (Combined) lter lters 99.97% particles smaller than 0.3 micron. Under continuous use, replace every 6 months.
IceTechTM Carbon The Carbon lter absorbs contaminants in the air Filter (Combined) such as gasses and odors. The Carbon lter is attached to the HEPA lter.
UV & IceTechTM TiO2 The UV lamp and Photocatalytic (TiO2) lter works together Filter (Combined)* to destroy viruses and VOC too small to be captured by the HEPA lter. *Available in 7 Stage Only
PART FUNCTION
Ceramic Ozone Plate Holder Slot
Arrow Points Forward
Power Cord
Plug-In
UNDERSTANDING YOUR AIR PURIFIER (BACK VIEW)
UV Lamp*
Fuse
Loading...