FAST, SLOW & TEMPO MODE MEASUREMENTS
QUAD ENVELOPE MANUAL V.1
PG. 7
TIME
NOTE/GATE ON NOTE/GATE OFF
HOLD DECAY SUSTAIN RELEASE
ATTACK CURVES
FAST MODE: exponential
SLOW MODE: linear
TEMPO MODE: variable from expo at fastest to linear at slowest
ATTACK TIMES: TRIGGER MODE GATE MODE
F) min 2ms, max 300ms F) min 2ms, max 300ms
S) min 50ms, max 28sec S) min 40ms, max 28sec
T) variable* T) variable*
HOLD TIMES: TRIGGER MODE GATE MODE
F) min 0ms, max 280ms F) min 0ms, max 280ms
S) min 0ms, max 28sec S) min 0ms, max 28sec
T) variable* T) variable*
DECAY CURVES: FAST MODE: exponential
SLOW MODE: linear
TEMPO MODE: variable from expo at fastest to linear at slowest
DECAY TIMES: TRIGGER MODE GATE MODE
F) min 2ms, max 1.4sec F) min 2ms, max 1.4sec
S) min 47ms, max 28sec S) min 50ms, max 28sec
T) variable* T) variable*
SUSTAIN: TRIGGER MODE: Sets voltage level where transition from Decay to Release
occurs. Creates break point (gate sustain is ignored in TRIGGER MODE).
GATE MODE: Sets voltage level where gate sustains (0v-10v) before Release
RELEASE CURVE: FAST MODE: linear
SLOW MODE: linear
TEMPO MODE: variable from expo at fastest to linear at slowest
RELEASE TIMES: TRIGGER MODE GATE MODE
F) min 20ms, max 9sec F) min 20ms, max 9sec
S) min 50ms, max 28sec S) min 50ms, max 28sec
T) variable* T) variable*
*1/32,1/16,1/8,1/4,1/2 or 1/1
ATTACK
linear
exponential