Magellan K32IRF Quick Reference Manual

K32IRF - User’s Quick Reference Guide
KEYPAD OVERVIEW
Partition Status
AC
To Regular Arm:
1. Close all zones in the desired partition.
ACCESS CODE]‡ or [ARM] + [ACCESS
CODE]
To Stay Arm:
1. Press the [
STAY] key.
2. Enter your [
ACCESS CODE]‡.
To Sleep Arm:
1. Press the [
SLEEP] key.
2. Enter your [
ACCESS CODE]‡.
If needed, press button(s) corresp onding to desired pa rtition(s). For two par titions, press the other key af ter the confirmat ion beep.
ARMING AND DISARMING
TO ARM
WHEN LEAVING...
TO ARM
WHEN STAYING...
To Disarm:
[
OFF] + [ACCESS CODE]
[TBL] Trouble display
On = Trouble(s) occurring
Arm / Sleep / Stay:
On = Partition armed Off = Partition disarmed Flash = Exit Delay Fast Flash= Exit Delay (final 10 sec.) Fast Flash= Partition in alarm
Audible Indicators: Continuous beep = Alarm V ariable beep = Fire alarm Intermittent beep = Beginning of exit delay Fast beep = Final 10 sec. of exit delay
Zone Display:
Numbers [1] to [32] correspond to zones 1 to 32 respectively. Open or entry delay zones are illuminated, and flash in alarm.
StayD
On = StayD enabled Off = StayD disabled
TX
Fast Flash = Communication with panel in progress
Zone Status
Info:
Refresh display to see all open zones
[
MEM] Alarm memory display
On = Alarm(s) occurred
[
BYP] Bypass programming
On = Zone(s) bypassed
Keys
= Press once + [MASTER CODE] for Quick Menu programming
= Press & hold for keypad settings
= Press & hold for chime programming
Bypassed zones remained unarmed when the partition is armed.
1. Press the [
BYP] key.
2. Enter your [
ACCESS CODE]‡.
3. The corresponding zone number will be displayed on the screen when open. Select the zone(s) you want to bypass by entering the two-digit zone number. For example, to enter zone 3, enter [0] then [3]. The corresponding zone indicator will flash.
4. To save and exit, press [
ENTER].
A Chime Enabled zone will advise you every time it is opened by causing your keypad to beep.
1. Press & hold the [] key. The word ‘Chime’ appears on the screen.
2. Select the zones you want to Chime by entering the two-digit zone number. The corresponding zone number flashes. For example, to chime zone 2 enter [0] then [2]. The keypad automatically saves once the 2­digit zone number is entered.
3. To save and exit, press [
ENTER].
BYPASS PROGRAMMING
CHIME PROGRAMMING
© Paradox Security Systems Ltd., 2008. Magellan is a trademark or registered trademark of Paradox Security Systems Ltd. and its affiliates in Canada, the United States and/or other countries. All rights reserved.
PARADOX.COM
Printed in Canada 05/2008 K32IRF-EQ00
To send a silent or audible alarm to your monitoring station, press and hold one of the following combinations for 3 seconds.
1. Press the [
TBL] key. The word ‘Trouble’ and
the number(s) corresponding to the trouble(s) are displayed on the screen.
2. Read the corresponding explanation of the trouble from the trouble list in the MG/SP Use r Guide. If no repair instructions are given, call your security company for repairs.
3. To exit, press [
CLEAR].
\
To view the alarms that occurred during the last armed period:
1. Disarm the system.
2. Press the [
MEM] key.
3. The corresponding zone numbers that were in alarm the last time the system was armed will appear on the screen.
4. To exit, press [
CLEAR].
To mute the keypad:
Press and hold the [
CLEAR] key for 10 seconds
to enable or disable Keypad Muting.
To adjust the backlight level:
1. Press and hold the [S] key for 4 seconds.
2. Keys [1] and [2] flash.
3. Press [1], then use the [S] and[T] to adjust.
4. To save and exit, press [
CLEAR] or [ENTER].
To adjust the backlight delay:
1. Press and hold the [S] key for 4 seconds.
2. Keys [1] and [2] will flash.
3. Press [2], then use the [S] and[T] to adjust.
4. To save and exit, press [
ENTER].
PANIC ALARMS
Panic Alarm Type Button Combinations
Police Medical Fire
Press [1] & [3] Press [4] & [6] Press [7] & [9]
TROUBLE DISPLAY
ALARM MEMORY DISPLAY
KEYPAD SETTINGS