No part of this publication may be modifi ed or adapted in any way, for any
purposes without permission in writing from Luxul. The material in this manual
is subject to change without notice. Luxul reserves the right to make changes to
any product to improve reliability, function, or design. No license is granted, either
expressly or by implication or otherwise under any Luxul intellectual property rights.
An implied license only exists for equipment, circuits and subsystems contained in
this or any Luxul product.
DOCUMENT CONVENTIONS
These graphical alerts are used in this document to indicate notable situations:
NOTE: Tips, hints, or special requirements that you should take note of.
CAUTION: Care is required. Disregarding a caution can result in data
loss or equipment malfunction.
WARNING!: Indicates a condition or procedure that could result in
personal injury or equipment damage.
FCC COMPLIANCE
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that
may cause undesired operation.
CONTACT LUXUL
Sales
P: 801-822-5450
E: sales@luxul.com
2
Technical Support
P: 801-822-5450
E: support@luxul.com
14203 Minuteman Drive, Suite 201, Draper, UT 84020-1685 | luxul.com | 801-822-5450
LUX-QIG-XMS-2624P 016150909
Simply Connected
PACKAGE CONTENTS
The following items are included in the box:
XMS-2624P 26-Port/24 PoE+ Gigabit Managed Switch
Power Cord
Rack Mount brackets and screws
Four rubber pads
Quick Installation Guide
If any of the listed items are missing or damaged, please contact the Distributor
from whom you purchased for return/replacement.
HARDWARE DESCRIPTION
Front Panel
The front panel of the XMS-2624P Switch includes 1 console port, 24 Gigabit RJ45
Ports and 2 RJ45/SFP combo ports for expansion, as well as LED indicators for each
port. Each Gigabit port has one Link/Activity/PoE LED. A push button switch with
an LED indicator switches the display between Link/Activity and PoE.
XMS-2624P Front Panel View
LED Indicators
Each port has one Link/Activity/PoE LED. A push button switch with LED indicator
switches the display between Link/Activity and PoE.
Other trademarks and registered trademarks are the property of their respective owners
3
XMS-2624P
Quick Install Guide
LED indicators show the working status of the switch. The following table describes the LED functionality:
Indicator
Name
System
Speed/PoE
Button
Speed
PoE
At startup, port LEDs will flash for 1 second as a self test.
When an SFP optical interface is in use, the Link/Activity LED of the corresponding Ethernet
port will indicate the SFP status.
Description
Green Flashing Indicates that the XMS-2624P is running normally.
Green OnBooting up or indicates a malfunction. Contact
technical support.
Red OnThis LED indicates the XMS-2624P in power on system
initialization process.
OffIndicates that the XMS-2624P is in startup and initialization
process or is not on.
Speed OnPort LED’s display Speed status
PoE OnPort LED’s display PoE status
GreenThe Link/Activity LED of the port will be on if there is a
1000Mbps device connected to the port.
YellowThe Link/Activity LED of the port will be on if there is a
10/100Mbps device connected to the port.
FlashingThe Link/Activity LED flashes when a port is receiving
or transmitting data.
OffThere is nothing connected to the port.
OnConnected device is receiving PoE Power.
OffConnected device is not receiving PoE power.
GreenPower being supplied within PD Specified limits
YellowPower exceeds PD Specified limits
Yellow
Flashing
PoE Fault( i.e. problem with Ethernet cable or PoE device).
4
14203 Minuteman Drive, Suite 201, Draper, UT 84020-1685 | luxul.com | 801-822-5450
LUX-QIG-XMS-2624P 016150909
Simply Connected
Rear Panel
XMS-2624P Rear Panel View
Power Input: Please use the included power cable
PREPARING FOR INSTALLATION
System Requirements
Ethernet Cables to connect the XMS-2624P to Ethernet enabled devices
Computer equipped with a Web browser. Supported Web browser versions
include Microsoft I.E. 9.0, Firefox 3.6, Safari 5.0, Chrome 6.0, Opera 10.6 and up.
The Web browser is used to configure the XMS-2624P.
Power must be AC 100-240V~ 4.7A 50/60Hz.
Before Connecting to the Network
The XMS-2624P can be rack-mounted or used as a desktop switch. Before connecting to the network, please be aware of the following requirements:
Install the XMS-2624P in a stable/safe place to avoid any possible damage
Make sure there is space around the XMS-2624P for adequate ventilation and proper
heat dissipation. It is recommended to have at least 4-6 inches around all sides.
Do not place heavy articles on the XMS-2624P.
Power outlets should be within 5 feet of the XMS-2624P.
Verify the ground connection of the outlet is functioning properly.
Check the power cord to confirm a secure connection.
Avoid placement in direct sunlight.
When installing the XMS-2624P on a flat surface, attach the rubber feet to the
bottom of the device to avoid scratching the surface.
Other trademarks and registered trademarks are the property of their respective owners
5
XMS-2624P
Quick Install Guide
XMS-2624P INSTALLATION
Installing the XMS-2624P in a Rack
The XMS-2624P can easily be installed in a standard 19” rack. The XMS-2624P includes
two mounting ears for installing and stabilizing the switch. When attaching the
mounting ears and installing the switch within a rack, please refer to the following
illustration:
Rack-Mounting the XMS-2624P
Using the included screws, attach the mounting ears to each side of the switch.
Mount the switch in the rack with the LEDs facing outwards. Be sure the switch is
level and properly secured within the rack.
Desktop Setup
For use as a desktop device, position and apply the included rubber feet to the
bottom of the XMS-2624P.
Attaching the Rubber Feet to the XMS-2624P
Network Connections:
The XMS-2624P supports 10/100/1000 Mbps Ethernet; 10/100 Mbps half/fullduplex mode and 1000 Mbps full-duplex mode. All RJ-45 ports support Auto MDI/
MDIX and can be used as ordinary ports or as Uplink ports. Any RJ-45 port can be
used to connect the XMS-2624P to an Ethernet enabled device (including servers,
routers, and other switches) without a crossover cable.
The XMS-2624P offers 2 shared optical module expansion ports. Once the Gigabit
SFP optical modules are inserted, these interfaces can support optical fi ber cables
to extend the Gigabit network—enabling the network to reach beyond the 300
foot limitation of twisted pair Ethernet.
6
14203 Minuteman Drive, Suite 201, Draper, UT 84020-1685 | luxul.com | 801-822-5450
LUX-QIG-XMS-2624P 016150909
Simply Connected
For the RJ-45 ports, Category-5, super Category-5 or Category-6 unshielded twisted
pair (CAT5/CAT5e/CAT6 UTP) should be used.
NOTE: For best results, it is recommended that Category-6 shielded
Optical fiber/cable should be selected based on the wavelength of the SFP
optical module to be used.
Make sure only one Uplink channel exists between switches or between the XMS2624P and a router. Otherwise, loops can occur and result in network failure.
Default IP Address
The XMS-2624P default IP address is 192.168.0.4. This address can be changed.
However, for hassle free installation of other plug and play Luxul devices, it is
recommended that the default IP value be maintained.
Login
The XMS-2624P is not equipped with internal DHCP server. However, if your switch
is connected to a Luxul Router, configuration will be automatic. Otherwise, the
IP address of the computer for login and configuration will need to be manually
configured. The table below lists the default parameters of the XMS-2624P.
twisted pair be used to ensure stable data transmission at 1000 Mbps.
Parameter: Default Value
Default IP address:
Default user name:
Default password:
192.168.0.4
admin
admin
Login to the switch with the following steps:
1. Plug an Ethernet cable into any of the ports of the switch
2. Plug the other end into the Ethernet port of your computer
3. Power on the switch
4. Check to see that the IP address of the computer is within this network
segment: 192.168.0.xxx (“xxx” ranges 1~254). For example, 192.168.0.100.
5. Open the Web browser, and enter 192.168.0.4. The login window appears.
6. Enter the user name and password (default user name and default password
are both set as “admin”), and then click “OK” to login to the switch
configuration window.
Other trademarks and registered trademarks are the property of their respective owners
7
ADVANCED SETTINGS
For login and advanced settings information go to luxul.com
WARNINGS AND SAFETY INFORMATION
Verify that the electrical circuits have appropriate grounding and overload protection.
Attach only approved power cords to the device.
Verify there is adequate ventilation around the device, and that ambient temperatures meet equipment
operation specifications.
The XMS-2624P is designed for indoor use only. DO NOT place this outdoors.
DO NOT install in or near hot or humid places, such as a kitchen or bathroom. Take care to minimize
exposure to excessive heat or moisture.
Small parts and plastic bags used for packaging may be harmful to small children. KEEP All
ACCESSORIES OUT OF THE REACH OF CHILDREN!
The XMS-2624P may become warm when in use for extended time periods. This is normal and is not a
malfunction. DO NOT install where it will be exposed to paper, cloth or other flammable materials.
FCC Statement:
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant
to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the user will be required to correct
the interference at his own expense.
FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
This device complies with part 15 of the FCC Rules.
Hereby, Luxul, 14203 Minuteman Drive, Suite 201, Draper, Utah, 84020, declares that this Luxul
XMS-2624P is in compliance with the essential requirements and other relevant provisions of
Directive 1999/5/EC.
For a copy of this report send a self addressed stamped envelope to:
Luxul CE, 14203 Minuteman Drive, Suite 201, Draper, Utah, 84020.
Industry Canada
CAN ICES-3(A)/NMB-3(A)
Information on this document supersedes all previous versions. Products and documents
subject to change without notice. Products may be discontinued without notice.
LUX-QIG-XMS-2624P
016150909
14203 Minuteman Drive, Suite 201, Draper, UT 84020-1685
luxul.com | 801-822-5450
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.