Luxul XFS-1816P User Manual

Simply Connected
Quick Install Guide
XFS-1816P
18-Port/16 PoE+/2 Gig Uplink
Smart Switch
Use the XFS-1816P to:
f
Connect up to 16 IP Cameras or Other PoE-Enabled Devices
f
Add PoE/PoE+ Capability to Your Network (Max Output 230 Watts)
f
Enable High Speed LAN Connectivity with Gigabit Uplinks
f
Simply Plug and Play
XFS-1816P
Quick Install Guide
Quick Install Guide
Model Number: XFS-1816P
18-Port/16 PoE+/2 Gig Uplink Smart Switch
© 2015 Luxul. All Rights Reserved.
No part of this publication may be modifi ed or adapted in any way, for any purposes without permission in writing from Luxul. The material in this manual is subject to change without notice. Luxul reserves the right to make changes to any product to improve reliability, function, or design. No license is granted, either expressly or by implication or otherwise under any Luxul intellectual property rights. An implied license only exists for equipment,
circuits and subsystems contained in this or any Luxul product.
DOCUMENT CONVENTIONS
The following graphical alerts are used in this document to indicate notable situations:
NOTE: Tips, hints, or special requirements that you should take note of.
CAUTION: Care is required. Disregarding a caution can result in data
WARNING!: Indicates a condition or procedure that could result in
loss or equipment malfunction.
personal injury or equipment damage.
FCC COMPLIANCE
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undesired operation.
CONTACT LUXUL
Sales
P: 801-822-5450 E: sales@luxul.com
2
a: 14203 Minuteman Drive, Suite 201, Draper, UT 84020-1685 | luxul.com | 801-822-5450
Technical Support
P: 801-822-5450 E: support@luxul.com
LUX-QIG-XFS-1816P-v1 029151040
Simply Connected
PACKAGE CONTENTS
f
18-Port/16 PoE+/2 Gig Uplink Smart Switch
f
Power cable
f
Two L-shape brackets and eight matched screws
f
Four rubber footpads
f
Quick Install Guide
If any of the listed items are missing or damaged, please contact the reseller from whom you purchased for return/replacement.
HARDWARE DESCRIPTION
Front Panel
The front panel of the XFS-1816P switch includes 16 10/100Mbps ports, 2 Gigabit uplink ports and 1 shared Gigabit SFP port. Each port has one Link/Activity LED, and one PoE LED. There
are also two Gigabit uplink LEDs, one Power LED, one System LED, and a reset button.
XFS-1816P Front Panel
Status indicators
Each port has one Link/Activity LED, and one PoE LED. In addition, there are two Gig uplink LEDs, one Power LED, one System LED, as well as a Reset button to reboot the device or restore factory default settings. The green LED indicators show the working status of the
switch. The following table describes the LED functionality:
© 2015 Luxul. All Rights Reserved.
Other trademarks and registered trademarks are the property of their respective owners
3
XFS-1816P
Indicator Name Description
Power
Link/Act
PoE
System
At startup, port LEDs will flash for 1 second as a self test.
On Indicates that there is power to the XFS-1816P
Off If LED is off, check power connections and on/off
switch at the back of the unit.
On There is a device connected to the port.
Flashing A port is receiving or transmitting data.
Off There is nothing connected to the port.
On A PoE enabled device is connected and being supplied
power
Off No PoE enabled device is connected or PoE is not
enabled on this port
On The XFS-1816P is booting up or restoring default
settings.
Flashing Indicates that the XFS-1816P is running normally.
Off The XFS-1816P is in startup and initialization process or
is not on.
Quick Install Guide
Reset Button
The Reset button (Located at the lower right corner of the front panel) is used to clear the current settings of the switch and restore factory default settings.
How to Use the Reset Button
f
To Hard Reset the Switch: With the XFS-1816P powered on, press the Reset button
CAUTION: DO NOT hold the button as this will factory default
f
To Restore the Default Settings: With the XFS-1816P powered on, press and hold the Reset but­ton for 15 seconds. You can now release the Reset button, and the switch automatically restores the factory default settings. When the System LED comes on again, the XFS-1816P will be set to factory defaults.
the switch
CAUTION: Please note this will remove any configuration done to the switch
4
prior to Reset.
a: 14203 Minuteman Drive, Suite 201, Draper, UT 84020-1685 | luxul.com | 801-822-5450
LUX-QIG-XFS-1816P-v1 029151040
Simply Connected
Network Ports
f
16 10/100Mbps RJ-45 ports (Ports 1~16), that support Auto MDI/MDIX.
f
2 Gigabit uplink ports
f
1 shared Gigabit SFP port.
NOTE: The SFP expansion port cannot support optical connections until
Rear Panel
The rear panel provides an AC input socket and power on/off switch. Use the included power cable to connect the XFS-1816P to a surge protected outlet. The built-in high-perfor­mance switching power supply of the XFS-1816P supports an input range of: AC 100-240V,
50/60Hz 3A.
equipped with an SFP (Mini GBIC) optical module.
NOTE:
When powering up, the port LEDs corresponding to the optical interface may take a moment to initialize. This is normal as the XFS-1816P does not detect the optical connection until after the initialization and startup of internal software systems are completed.
NOTE: To extend your wired network connections beyond 300 feet, an optical
connection will be required. Please contact your Luxul representative or go to our website to learn more about optical fiber, SFP optical modules and optical network installation.
INSTALLATION PREPARATION
System and Environmental Requirements
f
Network cables to connect the XFS-1816P to Ethernet enabled devices
f
A computer supporting TCP/IP and equipped with a Web browser. Supported Web browser ver­sions include Microsoft IE 9.0 and up, Safari 5.0, and up or, Chrome 6.0, Opera 10.6, Mozilla Firefox
3.6 and up. The Web browser is used to configure the XFS-1816P.
f
Power must be AC 100 ~ 240V, 50/60Hz 3A.
f
Temperature of the operating environment should be: 32F~113F (0C~45C). Place the switch away from heat generating devices. For best performance and heat dissipation/ventilation, make sure there is adequate space around the switch.
f
Humidity of the operating environment should be: 5%-95% non-condensing. Do not place the switch in an extremely dirty or damp location.
f
Keep the switch away from strong electromagnetic fields (i.e. Air Conditioner compressors, fluores­cent light ballasts, CRT monitors/televisions, etc.), and free from vibration, dust and direct sun light.
© 2015 Luxul. All Rights Reserved.
Other trademarks and registered trademarks are the property of their respective owners
5
XFS-1816P
Quick Install Guide
3.2 Before Connecting to the Network
f
The XFS-1816P can be rack-mounted or used as a desktop switch. Before connecting to the network, please be aware of the following requirements:
f
Install the XFS-1816P in a stable/safe place to avoid any possible damage
f
Make sure there is adequate space around the XFS-1816P for adequate ventilation and proper heat dissipation. It is recommended to have at least 4-6 inches around all sides.
f
Do not place heavy articles on the XFS-1816P.
f
Power outlets should be within 5 feet of the XFS-1816P.
f
Verify the ground connection of the outlet is functioning properly.
f
Check the power cord to confi rm a secure connection.
f
Avoid placement in direct sunlight.
f
When installing the XFS-1816P on a fl at surface, attach the rubber feet to the bottom of the device to avoid scratching the surface.
XFS-1816P INSTALLATION
Installation on Desktop/Shelf
As shown below, attach the four rubber footpads to 4 corner indentations on the bottom of the XFS-1816P. Place the switch horizontally on a solid, level platform.
Desktop/Shelf Installation of XFS-1816P
Installation in a Rack
The XFS-1816P is suitable for 19-inch rack installation. With the included L brackets, it can be conveniently installed into a server or audio rack. As shown below, use four screws to attach the L-shaped brackets on either sides of the XFS-1816P, and horizontally insert the switch into a free space within the rack. Use your desired hardware to affi x the switch supports to
the rack.
L-Shaped Supports for XFS-1816P
6
a: 14203 Minuteman Drive, Suite 201, Draper, UT 84020-1685 | luxul.com | 801-822-5450
LUX-QIG-XFS-1816P-v1 029151040
Simply Connected
Network Connections
The XFS-1816P supports 10/100 Mbps half/full-duplex mode. All RJ-45 ports support Auto MDI/MDIX and can be used as ordinary ports or as Uplink ports. Any RJ-45 port can be used to connect the XFS-1816P to an Ethernet enabled device (including servers, routers, and other switches) without a crossover cable.
The XFS-1816P offers 2 Gigabit uplink ports and 1 shared Gigabit SFP module expansion port. When Gigabit SFP optical modules are inserted, these interfaces can support optical fiber cables to extend the Gigabit network up to 49 miles—enabling the network to extend beyond the 300 foot limitation of twisted pair Ethernet.
Network Transmission Media
For the RJ-45 ports, Category-5, super Category-5 or Category-6 unshielded twisted pair (CAT5/CAT5e/CAT6 UTP) should be used. For best results, it is recommended that Category-6 shielded twisted pair be used to ensure stable data transmission at 1000 Mbps. Optical fiber/cable should be selected based on the wavelength of the SFP optical module to be used.
CAUTION:
Make sure only one Uplink channel exists between switches or between the XFS-1816P and a router. Otherwise, loops can occur and result in network failure.
CONFIGURATION
Login
The XFS-1816P is not equipped with internal DHCP server. However, if you are connect­ing to a Luxul Router with the default LAN address, the configuration will be automatic. Otherwise, the IP address of the computer for login and configuration will need to be manu-
ally configured. The table below lists the default parameters of the XFS-1816P.
Parameter: Default Value
Default IP address:
Default user name:
Default password:
Login to the switch with the following steps:
1. Plug an Ethernet cable into any of the switch ports
2. Plug the other end into the Ethernet port of your computer
3. Power on the switch.
© 2015 Luxul. All Rights Reserved.
Other trademarks and registered trademarks are the property of their respective owners
192.168.0.4
admin
admin
7
4. Check to see that the IP address of the computer is within this network segment: 192.168.0.xxx (“xxx” ranges 2~254. For example, 192.168.0.50). For IP address settings, refer to Appendix 2.
5. Open the Web browser and enter 192.168.0.3. The switch login window appears.
6. Enter the user name and password (default user name and default password are both set as “admin”), and then click “OK” to login to the switch configuration window.
Click any menu item on the left to view and/or modify the corresponding settings or functions.
ADVANCED SETTINGS
For login and advanced settings information see the User Guide on luxul.com
FCC Statement:
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
This device complies with part 15 of the FCC Rules.
Hereby, Luxul, 14203 Minuteman Drive, Suite 201, Draper, Utah, 84020, declares that this Luxul XFS-1816P is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC.
For a copy of this report send a self addressed stamped envelope to: Luxul CE, 14203 Minuteman Drive, Suite 201, Draper, Utah, 84020.
Industry Canada
CAN ICES-3(A)/NMB-3(A)
Information on this document supersedes all previous versions. Products and documents
subject to change without notice. Products may be discontinued without notice.
LUX-QIG-XFS-1816P-v1 029151040
a: 14203 Minuteman Drive, Suite 201, Draper, UT 84020-1685
luxul.com | 801-822-5450
Loading...